MAURY USCG vessel records Sign in
← All vessels

ISLAND FOX

ISLAND FOX is a 1976 passenger vessel (inspected). The Coast Guard has recorded 75 inspections since 1985, most recently in February 2025, along with 144 deficiencies, 2 operational controls and 1 casualty investigation in 2023.

Records from 1985 to 2025. Most recent: inspection, 26 February 2025.

Built
1976
Last inspected
26 February 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDM7667
Flag
UNITED STATES
368236210
Maury page id
psix-48719

Inspections, by type

…with no type recorded9
Years with a record 36 calendar years (1985–2025)
The 75 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)47.8 ft × 15.2 ft × 6.3 ft
Registered tonnagegross 35 / net 24
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDELTA MARINE & J KULAVIK · SEATTLE & ABERDEEN, WA, UNITED STATES · built 1976
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portCHANNEL ISLANDS, CA
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 28 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it35 - Regulatory (Subpart C or D), Gross Ton
24 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDM7667MMSI 368236210 · active · compulsorily equipped · granted 26 January 2022, expires 26 January 2032
WDH8354MMSI 367657130 · expired · compulsorily equipped · granted 13 February 2015, cancelled 19 April 2025 · licensed under a name not among this hull’s recorded names (not shown)
WCP7326MMSI 367012120 · expired · compulsorily equipped · granted 19 January 2005, cancelled 28 March 2015 · licensed under a name not among this hull’s recorded names (not shown)
WCZ5879MMSI 366774910 · expired · compulsorily equipped · granted 9 December 1999, cancelled 13 February 2010 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 75

26 February 2025 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 8085306
18 October 2024 In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 8021147
18 March 2024 Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7879683
11 March 2024 Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7877005
16 January 2024 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7849681
13 April 2023 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7668876
13 March 2023 Deficiency Check · Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7644786
1 February 2023 Construction Oversight · Plan Review "T" Boat
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7630450
19 December 2022 Plan Review "T" Boat
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7611154
29 November 2022 COI Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7597985
8 February 2022 Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7385029
1 March 2021 Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7144560
13 January 2021 Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7122926
2 March 2020 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6919126
15 March 2019 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6653802
27 February 2019 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6632217
20 February 2019 Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6628428
30 August 2018 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6531760
1 December 2017 Deficiency Check · COI Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6313405
10 March 2017 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6101452
6 January 2017 Plan Review "T" Boat · Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6067274
8 March 2016 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 5830371
15 February 2011 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3946094
11 January 2011 Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3924686
18 February 2010 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3681346
27 February 2009 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3425369
9 January 2009 Plan Review "T" Boat · Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3391081
22 January 2008 Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3134232
20 November 2007 COI Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3101893
22 February 2007 Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2876096
27 March 2006 Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2611205
1 February 2006 Hull Examination · Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2577696
28 February 2005 Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2301006
16 February 2005 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2293609
25 February 2004 In-Service Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2013556
7 January 2004 Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 1985529
4 November 2003 Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 1943191
27 November 2002 COI Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 1711586
27 February 2002 Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 1490508
22 January 2002 Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 1480530
3 April 2001 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1061498
19 February 2001 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1457899
23 January 2001 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1437837
21 January 2000 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1388982
20 January 2000 Plan Review "T" Boat
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1045962
30 November 1999 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1455785
9 November 1999 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 803216
8 October 1999 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1124512
21 April 1999 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1427647
11 February 1999 Plan Review "T" Boat
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1472819
24 December 1998 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 807413
8 December 1998 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1416801
22 December 1997 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1404497
16 December 1997 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1408023
4 December 1996 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1357809
26 January 1996 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1355649
6 December 1995 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1452097
25 April 1995 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 863680
9 January 1995 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1428428
16 December 1993 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1382674
12 December 1993 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 93833
7 December 1993 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1387436
10 February 1993 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1376942
14 January 1992 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1357910
11 December 1991 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 948034
16 May 1991 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1233934
13 December 1990 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1235441
12 December 1989 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 923109
16 November 1989 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 907205
20 December 1988 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1340536
12 May 1988 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1040865
21 December 1987 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1011847
2 February 1987 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1314755
18 December 1986 Hull Examination · Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1027246
18 June 1985 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1292295

Deficiency record · 144

11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 26 February 2025 Resolved
An inflatable liferaft or inflatable buoyant apparatus must be serviced at a facility specifically approved by the Commandant for the particular brand, and in accordance with servicing procedures meeting the requirements of part 160, subpart 160.151, of this chapter—(1) No later than the month and year on its servicing sticker affixed under 46 CFR 160.151-57(n). Vessel's IBA was being serviced at the time of inspection. Install serviced life raft to clear deficiency.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 March 2025
Resolution: Life raft serviced and installed. Hydro release was replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 February 2025 Resolved
Each life jacket carried on a vessel on oceans, coastwise, or Great Lakes route, must have a life jacket light approved in accordance with § 161.012 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.112. Each life jacket light must be securely attached to the front shoulder area of the life jacket. Vessel is restricted to a limited coastwise route until life jackets lights are installed on all life jackets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 11 March 2025
Resolution: Vessel replaced life jacket lights.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 26 February 2025 Resolved
Each hydrostatic release unit, other than a disposable unit, must be serviced:(b) Each disposable hydrostatic release unit must be marked with an expiration date of two years after the date on which the unit is installed. EPIRB hydrostatic release not marked with expiration date. Install date unknown. Replace EPIRB hydrostatic release and mark expiration date for 2 years after install.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 March 2025
Resolved 10 March 2025
Resolution: Vessel provided evidence of new hydrostatic release.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 February 2025 Resolved
For fixed-gas fire extinguishing systems, the inspections and tests required by Table 176.810(b) of this section, in addition to the tests required by 46 CFR 147.60 and 147.65. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. Provide recent JOY FIRE servicing record for the engineroom fixed fire extinguishing system.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 March 2025
Resolved 27 February 2025
Resolution: Vessel provided service report from JOY FIRE.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 16 January 2024 Resolved
This part contains requirements for the design, construction, installation, and operation of propulsion and auxiliary machinery, piping and pressure systems, steering apparatus, and associated safety systems. Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Machinery space fuel oil return manifold valves were leaking diesel fuel oil. Inspect hoses and valves, determine source of fault and repair or replace.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 January 2024
Resolved 11 March 2024
Resolution: Vessel rectified leak by tightening the fitting.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 16 January 2024 Resolved
The flexible section must be accessible and as near the upper end of the fill pipe as practicable. When the flexible section is a nonconductor of electricity, the metallic sections of the fill pipe separated thereby must be joined by a conductor for protection against generation of a static charge when filling with fuel. Flexible hose from both fuel tanks to deck fill fittings were missing conductor. Install conductor to electrically join metallic sections of tank to metallic section of fill pipe for both fuel oil tank fills.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 February 2024
Resolved 2 February 2024
Resolution: Vessel electrically connected fill and fuel tank.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 16 January 2024 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules, except that a vessel of more than 19.8 meters (65 feet) in length must also have navigation lights that meet UL 1104, “Standards for Marine Navigation Lights,” or other standard specified by the Commandant. Stern light mounting was not secured causing light to angle. Repair or replace stern light mounting to appropriate angle.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 January 2024
Resolved 18 January 2024
Resolution: Vessel remounted stern light.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 29 November 2022 Resolved
EAP education program: Each EAP education program must include at least the following elements: display and distribution of informational material; display and distribution of a community service hot-line telephone number for crewmember assistance, and display and distribution of the employer's policy regarding drug and alcohol use in the workplace. Community service hot-line telephone number was not available or displayed. Post hot-line telephone number for crew member assistance.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 December 2022
Resolved 9 December 2022
Resolution: Vessel provided EAP hotline numbers in the pilothouse.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 November 2022 Resolved
Each floating waterlight must be approved in accordance with § 161.010 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.110. Waterlights on ring life buoy and life floats were found not in compliance with manufacturer instructions for battery replacement.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 December 2022
Resolved 9 December 2022
Resolution: Vessel purchased and installed new batteries.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 29 November 2022 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. First-Aid Kit contained expired items and was missing directions for the use of the First-Aid kit. Maintain a First-Aid Kit compliant with the requirements in 46 CFR 160.041.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 December 2022
Resolved 9 December 2022
Resolution: Vessel procured a new compliant first aid kit.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 29 November 2022 Resolved
Life floats and buoyant apparatus must not be stowed in tiers more than 4 feet high. When stowed in tiers, the separate units must be kept apart by spacers. No spacers were installed between life floats. Place spacers between life floats.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 December 2022
Resolved 9 December 2022
Resolution: Vessel provided spacers between life floats.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 29 November 2022 Resolved
Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information: (1) Date of the drill and training; and (2) General description of the drill scenario and training topics. Vessel had no record of abandon ship drills. Conduct and document abandon ship drill.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 29 November 2022
Resolved 29 November 2022
Resolution: Vessel conducted and logged abandon ship drill conducted during inspection.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 29 November 2022 Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crewmembers on inspected vessels who: (1) Occupy a position, or perform the duties and functions of a position, required by the vessel's Certificate of Inspection; (2) Perform the duties and functions of patrolmen or watchmen required by this chapter; or, (3) Are specifically assigned the duties of warning, mustering, assembling, assisting, or controlling the movement of passengers during emergencies. One crew member was not listed on the company’s covered crew member list. Provide documentation showing crew member was subject to pre-employment testing and is enrolled in a random testing program prior to the crew member serving in a position described above.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 December 2022
Resolved 9 December 2022
Resolution: Vessel provided new covered crew list showing identified crew memebr as being compliant.
05 - Radio Communications › N/A - No Subsystem › Performance standards for radio equipment
Issued 8 February 2022 Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with § 80.59 once every five years. The FCC-licensed technician must use the latest FCC Information Bulletin, How to Conduct an Inspection of a Small Passenger Vessel. If the ship passes the inspection, the technician will issue a Communications Act Safety Radiotelephony Certificate. Vessel did not have a current FCC Safety Radiotelpephony certificate on board.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 February 2022
Resolved 14 February 2022
Resolution: Vessel provided a current FCC SRC.
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 8 February 2022 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 February 2022
Resolved 28 February 2022
Resolution: Vessel provided consortium information including covered crew list, EAP information and records of supervisor training.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 8 February 2022 Resolved
Each survival craft must be stowed so that when the vessel sinks the survival craft floats free. Life float water lights are mounted under the pilot house overhang in a manner which could bind upon float free release. Move lights to facilitate float free arrangement.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 February 2022
Resolved 14 February 2022
Resolution: Vessel moved lights outside of overhang.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 8 February 2022 Resolved
The emergency instructions must be designed to address the particular equipment, arrangement, and operation of each individual vessel. Emergency instructions were not vessel specific. Provided and post vessel specific emergency instructions.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 February 2022
Resolved 14 February 2022
Resolution: Vessel provided updated emergency instructions that were vessel specific.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 8 February 2022 Resolved
Monthly inspections required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or a designated member of the crew. Vessel was not conducting or logging monthly inspections of portable fire extinguishers. Conduct inspections and provide record.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2022
Resolved 14 February 2022
Resolution: Vessel conducted and logged fire extignuisher check.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 8 February 2022 Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. EPIRB registration had the incorrect MMSI number for the vessel. Correct registration.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 February 2022
Resolved 14 February 2022
Resolution: Vessel provided updated EPIRB registration.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 8 February 2022 Resolved
The Rules concerning shapes shall be complied with by day. The lights and shapes specified in these Rules shall comply with the provisions of Annex I of these Rules (33 CFR part 84). Vessel was not carrying day shapes. Provide day shapes.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 February 2022
Resolved 14 February 2022
Resolution: Vessel provided day shape.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 2 March 2020 Resolved
Vessel shall complete an annual inspection prior to operating.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 March 2020
Resolution: Vessel completed a satisfactory annual inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 27 February 2019 Resolved
Repair bird damage to life floats.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 March 2019
Resolved 14 March 2019
Resolution: Floats repaired. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 27 February 2019 Resolved
Replace grab lines on life floats.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 March 2019
Resolved 14 March 2019
Resolution: Replaced grablines, all sat.
Documentation › Certificates/Documents › FCC SSL
Issued 1 December 2017 Resolved
Renew FCC Radio Safety Certificate.
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 January 2018
Resolved 12 December 2017
Resolution: FCC Radio Safety Certificate renewed.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 1 December 2017 Resolved
Label fireboy override switch.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 January 2018
Resolved 8 December 2017
Resolution: Fireboy override switch labled.
Stability › Watertight Integrity › General
Issued 1 December 2017 Resolved
Tighten packing on stbd rudder post.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 January 2018
Resolved 8 December 2017
Resolution: Packing was tightened.
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 1 December 2017 Resolved
Provide 01 life jacket light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 January 2018
Resolved 8 December 2017
Resolution: Life jacket light provided.
Communications › Radio Communications › EPIRB
Issued 1 December 2017 Resolved
Renew EPRIB battery.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2017
Resolved 8 December 2017
Resolution: Owner purchased a new EPRIB.
Communications › Radio Communications › EPIRB
Issued 1 December 2017 Resolved
Register new EPRIB with NOAA.
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 January 2018
Resolved 20 December 2017
Resolution: EPRIB registered with NOAA.
Construction/Loadline › Hull › Longitudinal Frame
Issued 1 December 2017 Resolved
Clean debris around forepeak bilge foot valve.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 January 2018
Resolved 8 December 2017
Resolution: Debris has been cleaned.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 10 March 2017 Resolved
Repair mast head light; restricted to daylight ops only.
Action required: 705 - Other - as specified
Due 10 April 2017
Resolved 21 March 2017
Resolution: Mast head light operational.
Communications › Radio Communications › VHF Radiotelephone
Issued 10 March 2017 Resolved
Connect VHF-DSC radio to GPS.
Action required: 705 - Other - as specified
Due 10 April 2017
Resolved 21 March 2017
Resolution: VHF connected to GPS.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 10 March 2017 Resolved
Obtain FCC Marine Radio Operators Permit for [name withheld].
Action required: 705 - Other - as specified
Due 10 April 2017
Resolved 7 April 2017
Resolution: New FCC Marine Operators Permit provided.
Communications › Radio Communications › EPIRB
Issued 9 March 2016 Resolved
Provide current NOAA registration for EPIRB.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 March 2016
Resolved 9 March 2016
Resolution: Current NOAA registration provided.
Communications › Alarms/Indicators › Bilge Alarm
Issued 9 March 2016 Resolved
Prove proper operation of bilge high level alarm in E/R.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 March 2016
Resolved 9 March 2016
Resolution: E/R bilge high level alarm operational.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 8 March 2016 Resolved
Complete annual inspection, vessel overdue as of 03MAR16.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 March 2016
Resolved 9 March 2016
Resolution: Annual inspection completed.
Lifesaving › Lifefloat › Serviceable
Issued 15 February 2011 Resolved
Service/Replace all Life Floats
Action required: 705 - Other - as specified
Due 16 March 2011
Resolved 29 February 2012
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 18 February 2010 Resolved
Prior to carrying psgrs, prove proper operation of fixed f/f system shut-down/override.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 February 2010
Resolved 19 February 2010
Communications › Radio Communications › EPIRB
Issued 18 February 2010 Resolved
Vsl limited to 3NM pending repair of EPIRB antenna
Action required: 705 - Other - as specified
Due 18 March 2010
Resolved 19 February 2010
Fire Fighting › Fire Bucket › Availability
Issued 18 February 2010 Resolved
Provide 3 fire buckets with lanyards.
Action required: 705 - Other - as specified
Due 18 March 2010
Resolved 19 February 2010
Stability › Weathertight Integrity › General
Issued 18 February 2010 Resolved
Replace hatch cover closure device (E/R)
Action required: 705 - Other - as specified
Due 18 March 2010
Resolved 19 February 2010
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 18 February 2010 Resolved
Replace 2 waterlight batteries prior to carrying psgrs.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 February 2010
Resolved 18 February 2010
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 18 February 2010 Resolved
Service firefighting equipment NLT 28FEB10
Action required: 705 - Other - as specified
Due 28 February 2010
Resolved 19 February 2010
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 18 February 2010 Resolved
Secure stern light
Action required: 705 - Other - as specified
Due 18 March 2010
Resolved 19 February 2010
Electrical › Lighting (service) › Lighting Fixture
Issued 18 February 2010 Resolved
Secure overhead light in E/R.
Action required: 705 - Other - as specified
Due 18 March 2010
Resolved 19 February 2010
Lifesaving › Lifefloat › Markings
Issued 18 February 2010 Resolved
Stencil life float capacity on two floats.
Action required: 705 - Other - as specified
Due 18 March 2010
Resolved 19 February 2010
Communications › Radio Communications › EPIRB
Issued 27 February 2009 Resolved
Prior to ops w/ psgrs >3 NM, replace EPIRB hydro release.
Action required: 705 - Other - as specified
Due 27 February 2009
Resolved 27 February 2009
Communications › Alarms/Indicators › Bilge Alarm
Issued 27 February 2009 Resolved
Repair laz hi-water alarm.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 February 2009
Resolved 27 February 2009
Stability › Watertight Integrity › General
Issued 11 February 2009 Resolved
Replace both shaft water seal hoses.
Action required: 705 - Other - as specified
Due 27 February 2009
Resolved 27 February 2009
Construction/Loadline › Hull › Side Shell
Issued 11 February 2009 Resolved
Scrape/clean/treat damaged wood in aft port corner of E/R from old deck leak.
Action required: 705 - Other - as specified
Due 27 February 2009
Resolved 27 February 2009
Stability › Unintentional Flooding › General
Issued 11 February 2009 Resolved
Replace hose between seacock and bait tank pump.
Action required: 705 - Other - as specified
Due 27 February 2009
Resolved 27 February 2009
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 11 February 2009 Resolved
Repair broken welds on bow railing stbd side
Action required: 705 - Other - as specified
Due 27 February 2009
Resolved 27 February 2009
Accommodation/Occupational Safety › Potable Water System › General
Issued 11 February 2009 Resolved
Submit proposal for replacement of potable water tanks.
Action required: 705 - Other - as specified
Due 27 February 2009
Resolved 27 February 2009
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 11 February 2009 Resolved
Make vessel available for check-ride.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 February 2009
Resolved 27 February 2009
Documentation › Logs/Records › Drug Test Records
Issued 20 November 2007 Resolved
Provide year-eng drug testing summary.
Due 21 December 2007
Resolved 27 November 2007
Lifesaving › Lifefloat › Retroreflective Material
Issued 20 November 2007 Resolved
Replace reflective tape on L/Fs.
Due 15 December 2007
Resolved 27 November 2007
Construction/Loadline › Structures › Machinery Space Opening
Issued 20 November 2007 Resolved
Install latches to the E/R entry hatch.
Action required: 705 - Other - as specified
Due 21 December 2007
Resolved 27 November 2007
Electrical › Electric Supply System (service) › Cable
Issued 20 November 2007 Resolved
Rewire both bait pumps with approved marine boat cable. Extension has been granted to complete during hull inspection.
Action required: 705 - Other - as specified
Due 15 January 2008
Resolved 22 January 2008
Electrical › Electric Supply System (service) › Cable
Issued 20 November 2007 Resolved
Replace all non approved marine cable in the E/R, laz, and accommodation space with approved boat cable. Extension has been granted until hull inspection in January 08.
Action required: 705 - Other - as specified
Due 15 January 2008
Resolved 22 January 2008
Operations/Management › Drills/Instruction › Abandon Ship
Issued 20 November 2007 Resolved
Complete MOB and fire drill to the prior to COI credit.
Action required: 705 - Other - as specified
Due 22 November 2007
Resolved 27 November 2007
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 22 February 2007 Resolved
Renew Radiotelephony Certificate.
Action required: 705 - Other - as specified
Due 22 March 2007
Resolved 15 May 2007
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 22 February 2007 Resolved
Ensure contents of first aid kit is complete and dated items are current.
Action required: 705 - Other - as specified
Due 22 March 2007
Resolved 15 May 2007
Lifesaving › Lifefloat › Pendant
Issued 22 February 2007 Resolved
Replace rotting pendants on lifelfloat.
Action required: 705 - Other - as specified
Due 22 March 2007
Resolved 19 June 2007
Engineering › Fuel Oil Service System › Hose
Issued 22 February 2007 Resolved
Replace all flexible fuel hose in E/R with appropriate hose (SAE J1942) and end fittings (SAE J1475) or metallic piping.
Action required: 705 - Other - as specified
Due 30 June 2007
Resolved 15 May 2007
Personnel › Certificates/Documents/Licenses › Certificate, CPR Course Completion
Issued 1 February 2006 Resolved
Provide current CPR/first aid card for 50% of the crew.
Action required: 705 - Other - as specified
Due 27 March 2006
Resolved 12 April 2006
Resolution: Requirement not compulsory, only recommended; deleted requirement.
Fire Fighting › Grease Extraction Hood › General
Issued 1 February 2006 Resolved
Clean galley exhaust ventilation hood.
Action required: 705 - Other - as specified
Due 27 March 2006
Resolved 27 March 2006
Navigation › Piloting/Steering › Marine Charts
Issued 1 February 2006 Resolved
Provide local charts and current nav pubs for the operating area.
Action required: 705 - Other - as specified
Due 27 March 2006
Resolved 27 March 2006
Fire Fighting › Remote Fuel Shutoff › General
Issued 1 February 2006 Resolved
Install E-fuel shut-off handles on (port and STBD fuel tank) so that individual my not reach no more then 12" into the compartment.
Action required: 705 - Other - as specified
Due 27 March 2006
Resolved 27 March 2006
Engineering › Bilge Water Management System › Not Operational
Issued 1 February 2006 Resolved
Make operational the bilge high-water alarm.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 February 2006
Resolved 1 March 2006
Lifesaving › Lifejacket/PFD (Type V) › Condition
Issued 1 February 2006 Resolved
Replace ring buoy.
Action required: 705 - Other - as specified
Due 27 March 2006
Resolved 27 March 2006
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 1 February 2006 Resolved
Clean bilge in the E/R of excess oil.
Action required: 705 - Other - as specified
Due 27 March 2006
Resolved 1 March 2006
Electrical › Electrical Distribution System (service) › Cable
Issued 1 February 2006 Resolved
Provide and install wire support IWO the storage comp for all zip-tied wire.
Action required: 705 - Other - as specified
Due 27 March 2006
Resolved 27 March 2006
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 15 February 2005 Resolved
Provide FCC emergency broadcast placard.
Action required: 705 - Other - as specified
Due 15 March 2005
Resolved 28 February 2005
Communications › Radio Communications › EPIRB
Issued 15 February 2005 Resolved
Establish log for monthly testing of E-PIRB.
Action required: 705 - Other - as specified
Due 15 March 2005
Resolved 28 February 2005
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 15 February 2005 Resolved
Repair compass light.
Action required: 705 - Other - as specified
Due 15 March 2005
Resolved 28 February 2005
Deck/Cargo › Holds/Tanks › Hatch
Issued 15 February 2005 Resolved
Clean channel & renew gasket for forepeak watertight hatch.
Action required: 705 - Other - as specified
Due 15 March 2005
Resolved 28 February 2005
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 15 February 2005 Resolved
Provide port and starboard shaft guards.
Action required: 705 - Other - as specified
Due 15 March 2005
Resolved 28 February 2005
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 15 February 2005 Resolved
Provide guard for rotating pulley on port engine.
Action required: 705 - Other - as specified
Due 15 March 2005
Resolved 28 February 2005
Deck/Cargo › Holds/Tanks › Hatch
Issued 15 February 2005 Resolved
Provide handle to open watertight hatch for lazarette compartment.
Action required: 705 - Other - as specified
Due 15 March 2005
Resolved 28 February 2005
Fire Fighting › Grease Extraction Hood › General
Issued 15 February 2005 Resolved
Clean grease from hood over cooking area.
Action required: 705 - Other - as specified
Due 15 March 2005
Resolved 28 February 2005
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 25 February 2004 Resolved
Renew retro-reflective material as needed on all Kapok life preservers.
Action required: 705 - Other - as specified
Due 25 March 2004
Resolved 15 February 2005
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 25 February 2004 Resolved
Replace 1 life preserver and repair life preserver with torn seam. Total # of passengers reduced by 2 until corrected.
Action required: 705 - Other - as specified
Due 25 March 2004
Resolved 15 February 2005
Lifesaving › Buoyant Apparatus
Issued 27 November 2002 Resolved
Renew grab lines and perimeter lines on 15 person life float. Passenger capacity is reduced by 15 until corrected.
Action required: 705 - Other - as specified
Due 27 December 2002
Resolved 27 November 2002
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 27 November 2002 Resolved
Renew lifeline and waterlight lanyard on ring buoy.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 November 2002
Resolved 27 November 2002
Navigation › Collision/Grounding Avoidance
Issued 27 November 2002 Resolved
Clean crazing from navigation lights. LEGACY COMPONENT DESC: Navigation Lights
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 December 2002
Resolved 25 February 2004
Electrical › Lighting (service)
Issued 27 November 2002 Resolved
Secure electrical cable for deck lights above pilot house. LEGACY COMPONENT DESC: Conductor
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 December 2002
Resolved 4 November 2003
Engineering › Bilge Water Management System
Issued 27 November 2002 Resolved
Make bulkhead penetrations for bilge suction lines for engine room and lazarette and overboard discharge in accordance with 46 CFR 182.720(d). LEGACY COMPONENT DESC: Piping
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 December 2002
Resolved 4 November 2003
Electrical › Electric Supply System (service)
Issued 27 November 2002 Resolved
Remove corrosion from terminals and from the bottom of the battery box for the starboard M/E starting battery and the generator starting battery. LEGACY COMPONENT DESC: Battery Installation
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 December 2002
Resolved 4 November 2003
Electrical › Electric Generation Source (service)
Issued 27 November 2002 Resolved
Repair bonding wire attached to port rudder post. LEGACY COMPONENT DESC: Grounding Conductor
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 December 2002
Resolved 4 November 2003
Electrical › Electric Generation Source (service)
Issued 27 November 2002 Resolved
Provide ammeter and frequency meter for A/C generator in accordance with 46 CFR 183.320(c). LEGACY COMPONENT DESC: Panelboard
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 December 2002
Resolved 4 November 2003
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 27 November 2002 Resolved
Repair water leak at pedro connection for port M/E exhaust. LEGACY COMPONENT DESC: Piping (exhaust)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 December 2002
Resolved 4 November 2003
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 27 November 2002 Resolved
Renew water injection hose for starboard M/E exhaust. LEGACY COMPONENT DESC: Piping (exhaust)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 December 2002
Resolved 4 November 2003
Accommodation/Occupational Safety › Medical/First Aid
Issued 27 November 2002 Resolved
Provide 1st aid kit in accordance with 46 CFR 184.710. LEGACY COMPONENT DESC: Medicine Chest
Action required: 705 - Other - as specified
Due 27 December 2002
Resolved 4 November 2003
Lifesaving
Issued 27 February 2002 Resolved
Provide 406 EPIRB with current vessel registration.
Due 27 March 2002
Resolved 28 February 2002
Resolution: Provided 406 EPIRB with current vessel registration.
Documentation › Logs/Records
Issued 27 February 2002 Resolved
Log monthly EPIRB test.
Due 27 March 2002
Resolved 28 February 2002
Resolution: Logged monthly EPIRB test.
Lifesaving › Buoyant Apparatus
Issued 27 February 2002 Resolved
Provide operational lifefloat light for the port lifefloat.
Due 27 March 2002
Resolved 28 February 2002
Resolution: Provided operational lifefloat light for the port lifefloat.
Navigation › Collision/Grounding Avoidance
Issued 27 February 2002 Resolved
Clean navigational lights. LEGACY COMPONENT DESC: Navigation Lights
Due 27 March 2002
Resolved 28 February 2002
Resolution: Cleaned navigational lights.
Electrical › Electric Supply System (service)
Issued 27 February 2002 Resolved
Replace all non-approved wiring with Coast Guard approved marine grade cable. LEGACY COMPONENT DESC: Cable
Action required: 705 - Other - as specified
Due 28 August 2002
Resolved 27 November 2002
Navigation › Piloting/Steering
Issued 27 February 2002 Resolved
Provide current tide tables. LEGACY COMPONENT DESC: Tide/Tidal Current Tables
Due 27 March 2002
Resolved 27 February 2002
Resolution: Provided current tide tables.
Fire Fighting › Structural Fire Protection - General
Issued 22 January 2002 Resolved
Make fore and aft engine room bulkheads vapor tight. LEGACY COMPONENT DESC: Structural Bulkhead Construction
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 February 2002
Resolved 28 February 2002
Resolution: Made fore and aft engine room bulkheads vapor tight.
Electrical › Electrical Distribution System (service)
Issued 22 January 2002 Resolved
Remove wire nuts and install proper crimp connectors for wire connections for electric pump on port side of generator in engine room. LEGACY COMPONENT DESC: Wiring
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 February 2002
Resolved 28 February 2002
Resolution: Removed wire nuts and installed proper crimp connectors for wire connections for electric pump on port side of generator in engine room.
Lifesaving
Issued 23 January 2001 Resolved
MAKE UP LIFEFLOAT PENDANTS AS PER 46 CFR 160.010-4(G).
Condition: Unknown
Due 3 April 2001
Resolved 3 April 2001
Electrical
Issued 23 January 2001 Resolved
PROTECT ENGINE ROOM BATTERY BOX FROM FALLING OBJECTS AS PER 46 CFR 183.354(B).
Condition: Unknown
Due 3 April 2001
Resolved 3 April 2001
Construction/Loadline
Issued 23 January 2001 Resolved
REPAIR OR REPLACE BROKEN HATCH COVER FORWARD OF DECKHOUSE.
Condition: Unknown
Due 3 April 2001
Resolved 3 April 2001
Navigation
Issued 30 November 1999 Resolved
REPAIR AS NEW STEERING SYSTEM RAM.
Condition: Unknown
Due 30 November 1999
Resolved 2 December 1999
Navigation
Issued 30 November 1999 Resolved
REPAIR AS NEW CRACKED PORT RUDDER FOUNDATON.
Condition: Unknown
Due 30 November 1999
Resolved 30 November 1999
Electrical
Issued 30 November 1999 Resolved
REMOVE ALL DEAD ENDED WIRING FROM ENGINE ROOM.
Condition: Unknown
Due 30 November 1999
Resolved 30 November 1999
Engineering
Issued 30 November 1999 Resolved
REPLACE IN KIND LUBE OIL HOSE AT INLET AND OUTLET OF LUBE OIL FILTER ON THEPORT PROPULSION ENGINE.
Condition: Unknown
Due 30 November 1999
Resolved 30 November 1999
Fire Fighting
Issued 8 October 1999 Resolved
CONDUCT POST INSTALLATION INSPECTION OF FIXED FIRE EXTINGUISHING SYSTEM IN THE PRESENCE OF ATTENDING COAST GUARD MARINE INSPECTOR PRIOR TO OPERATING WITH PASSENGERS FOR HIRE.
Condition: Unknown
Due 15 November 1999
Resolved 9 November 1999
Fire Fighting
Issued 8 October 1999 Resolved
INSTALL FIXED FIRE EXTINGUISHING SYSTEM IN ACCORDANCE WITH COAST GUARD APPROVAL LETTER DATED 03 MARCH 1999.
Condition: Unknown
Due 15 November 1999
Resolved 9 November 1999
Construction/Loadline
Issued 21 April 1999 Resolved
Replace all PVC or plastic bilge and main engine cooling pipe and fittings in the engine room using approved metallic pipe. Non-ferrous pipe where used must have a melting temperature of less than 1700 degrees F or meet the specific requirements listed in 182.730
Condition: Unknown
Due 21 April 1999
Resolved 21 April 1999
Construction/Loadline
Issued 8 December 1998 Resolved
Remove existing PVC bilge piping throughout vessel and install approved metallic piping IAW 182.510. Install valve for forepeak bilge suction.
Condition: Unknown
Due 8 December 1998
Resolved 8 December 1998
Lifesaving
Issued 8 December 1998 Resolved
Provide emergency broadcast placard.
Condition: Unknown
Due 8 December 1998
Resolved 8 December 1998
Engineering
Issued 8 December 1998 Resolved
Install grounding straps at fuel fill connections on either side of fill pipe hose fittings.
Condition: Unknown
Due 8 December 1998
Resolved 8 December 1998
Engineering
Issued 8 December 1998 Resolved
Install new hose clamps and tighten exsisting hose clamps on port propulsion engine exhaust system.
Condition: Unknown
Due 8 December 1998
Resolved 8 December 1998
Engineering
Issued 8 December 1998 Resolved
Install double hose clamp on generator fuel hose fittings.
Condition: Unknown
Due 8 December 1998
Resolved 8 December 1998
Accommodation/Occupational Safety
Issued 8 December 1998 Resolved
Mark door leading to lower cargo space "CREW ONLY NO PASSENGERS".
Condition: Unknown
Due 8 December 1998
Resolved 8 December 1998
Lifesaving
Issued 8 December 1998 Resolved
Install retroflective tape on life floats.
Condition: Unknown
Due 8 December 1998
Resolved 8 December 1998
Lifesaving
Issued 8 December 1998 Resolved
Provide a Coast Guard approve ring buoy.
Condition: Unknown
Due 8 December 1998
Resolved 8 December 1998
Lifesaving
Issued 8 December 1998 Resolved
Provide 03 type 1 Coast Guard approved adult life jackets.
Condition: Unknown
Due 8 December 1998
Resolved 8 December 1998
Fire Fighting
Issued 8 December 1998 Resolved
Provide 03 properly marked fire buckets.
Condition: Unknown
Due 8 December 1998
Resolved 8 December 1998
Lifesaving
Issued 8 December 1998 Resolved
Provide Coast Guard approved or equivilant first aid kit.
Condition: Unknown
Due 8 December 1998
Resolved 8 December 1998
Documentation
Issued 8 December 1998 Resolved
Provide a garbage disposal log.
Condition: Unknown
Due 8 December 1998
Resolved 8 December 1998
Documentation
Issued 8 December 1998 Resolved
Provide EPIRB test log.
Condition: Unknown
Due 8 December 1998
Resolved 8 December 1998
Fire Fighting
Issued 26 January 1996 Resolved
Prior to carring passengers have the one discharged portable fire extinguisher serviced.
Condition: Unknown
Due 16 February 1996
Resolved 9 February 1996
Lifesaving
Issued 26 January 1996 Resolved
Porvide seventeen additional Coast Guard approved type I lifejackets prior to carring more that 22 adults.
Condition: Unknown
Due 26 January 1996
Resolved 26 January 1996
Engineering
Issued 6 December 1995 Resolved
Repair wasted connections on the port and starboard fuel tanks.
Condition: Unknown
Due 15 December 1995
Resolved 22 December 1995
Construction/Loadline
Issued 6 December 1995 Resolved
Replace leaking gasket on the forward emergency escape hatch.
Condition: Unknown
Due 6 December 1995
Resolved 6 December 1995
Construction/Loadline
Issued 6 December 1995 Resolved
Crop and renew the wasted wood in way of the forward emergency escape hatch.
Condition: Unknown
Due 6 December 1995
Resolved 6 December 1995
Construction/Loadline
Issued 6 December 1995 Resolved
Clean and treat dry rotted areas in the engine room.
Condition: Unknown
Due 6 December 1995
Resolved 6 December 1995
Construction/Loadline
Issued 6 December 1995 Resolved
Dry and treat water damaged deck stringers and the forward bulkhead, port side, in the lazarrette.
Condition: Unknown
Due 6 December 1995
Resolved 6 December 1995
Construction/Loadline
Issued 6 December 1995 Resolved
Seal the deck separation, port side forward in the lazarrette.
Condition: Unknown
Due 6 December 1995
Resolved 6 December 1995
Lifesaving
Issued 9 January 1995 Resolved
CONDUCT UNDERWAY RESCUE AND FIRE DRILLS IN THE PRESENCE OF A COAST GUARD INSPECTOR.
Condition: Unknown
Due 9 January 1995
Resolved 9 January 1995
Lifesaving
Issued 9 January 1995 Resolved
REPAIR PENNANTS AND GRAB LINE ON THE 11 MAN LIFEFLOAT.
Condition: Unknown
Due 9 January 1995
Resolved 9 January 1995
Navigation
Issued 9 January 1995 Resolved
PROVIDE AN UP TO DATE CHART OF THE AREA IN WHICH THE VESSEL OPERATES.
Condition: Unknown
Due 9 January 1995
Resolved 9 January 1995
Lifesaving
Issued 9 January 1995 Resolved
REPLACE ONE ADULT LIFEJACKET. VESSEL LIMITED TO 38 TOTAL PERSONS ON BOARD UNTIL REQUIREMENT HAS BEEN MET.
Condition: Unknown
Due 9 January 1995
Resolved 9 January 1995
Electrical
Issued 10 February 1993 Resolved
Remove circuit multipliers from electrical outlets.
Condition: Unknown
Due 11 March 1993
Resolved 11 March 1993
Documentation
Issued 10 February 1993 Resolved
Provide vessel with waste disposal policy, post same on vessel.
Condition: Unknown
Due 11 March 1993
Resolved 11 March 1993
Lifesaving
Issued 10 February 1993 Resolved
Provide vessel with three (03) additional adult P.F.D.s. Vessel may only thirty-six (36) total persons on board until this requirement is satisfied.
Condition: Unknown
Due 11 March 1993
Resolved 11 March 1993
Accommodation/Occupational Safety
Issued 13 December 1990 Resolved
Run vent suction line to engine compartment bilge area.
Condition: Unknown
Due 13 December 1990
Resolved 13 December 1990
Navigation
Issued 13 December 1990 Resolved
Repair anchor light.
Condition: Unknown
Due 13 December 1990
Resolved 13 December 1990
Lifesaving
Issued 13 December 1990 Resolved
Renew life float grab lines on 12 man float.
Condition: Unknown
Due 13 December 1990
Resolved 13 December 1990
Navigation
Issued 16 November 1989 Resolved
REPLACE STEERING CONNECTION YOKE TO PORT & STBD RUDDER POSTS.
Condition: Unknown
Due 16 November 1989
Resolved 16 November 1989
Electrical
Issued 16 November 1989 Resolved
REPAIR OR REPLACE THREE BATTERY BOXES.
Condition: Unknown
Due 16 November 1989
Resolved 16 November 1989

Casualty record · 1

13 April 2023Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 7668876
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.