← All vessels
BAY STATE
Passenger (Inspected) · Passenger Ship class · Built 1970s · USCG Northeast District (CGD-NE) · Other hulls named BAY STATE
BAY STATE is a 1976 passenger vessel (inspected). The Coast Guard has recorded 95 inspections since 1985, most recently in March 2026, along with 141 deficiencies and 2 casualty investigations between 2006 and 2008.
Records from 1985 to 2026. Most recent: inspection, 25 March 2026.
- Built
- 1976
- Last inspected
- 25 March 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 141 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 2 investigations · 2006–2008
Identity
572968
WDE6673
48721
Flag
UNITED STATES
367383190
Maury page id
psix-48721
Inspections, by type
…with no type recorded14
Years with a record
37 calendar years (1985–2026)
The 95 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)97.8 ft × 27.1 ft × 7.6 ft
Registered tonnagegross 98 / net 74
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGAMAGE SHIPBUILDERS INC · SOUTH BRISTOL, ME, UNITED STATES · built 1976
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portLIBERTY ISLAND, NY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 20 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it98 - Regulatory (Subpart C or D), Gross Ton
74 - Regulatory (Subpart C or D), Net Ton
74 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDE6673MMSI 367383190 · active · compulsorily equipped · granted 3 October 2018, expires 4 November 2028
WCY6720MMSI not assigned · cancelled · compulsorily equipped · granted 1 September 1998, cancelled 21 December 2007 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 95
25 March 2026
Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8331886
27 October 2025
In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8257671
2 September 2025
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8225255
20 November 2024
In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8038115
18 September 2024
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7985480
20 March 2024
Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7875964
20 September 2023
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7785840
5 May 2023
Deficiency Check · In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7681690
23 June 2022
Deficiency Check · COI Inspection · Administrative Inspection · Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7463943
10 February 2022
Deficiency Check · Internal Structural Exam · Hull Examination · Examination of Repairs
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7394155
27 October 2020
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7084789
30 October 2019
MTSA Verification · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6845170
9 April 2019
Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6658865
1 November 2018
In-Service Inspection · Annual Inspection · Administrative Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6572519
2 November 2017
Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6299329
4 April 2017
Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6117077
9 November 2016
Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6038076
4 November 2015
Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5756508
15 July 2011
Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4080369
14 December 2010
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3910349
10 November 2010
Deficiency Check · Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3891447
23 April 2009
Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3457521
3 February 2009
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3412244
10 November 2008
MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3360695
27 October 2008
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3352866
27 October 2008
Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3352975
20 April 2008
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3188236
12 February 2008
DAPI Audit
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3171231
31 January 2008
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3139797
20 December 2007
In-Service Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3122219
4 October 2007
MTSA Verification · Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3072847
3 May 2007
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2921355
6 February 2007
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2867792
19 October 2006
Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2803600
3 July 2006
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2836634
22 November 2005
Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2538911
18 July 2005
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2430997
7 April 2005
Hull Examination · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2328547
12 November 2004
MTSA Verification · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2239616
28 July 2004
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2148658
26 March 2004
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2031589
17 May 2003
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1816483
10 March 2003
Hull Examination · Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1758561
16 August 2002
Security Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1662390
11 March 2002
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1492695
19 June 2001
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 137497
8 May 2001
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1447085
28 March 2001
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1437880
14 March 2001
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1456947
14 July 2000
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 143182
9 June 2000
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1420330
25 April 2000
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1404954
7 October 1999
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1399190
13 April 1999
COI Inspection · Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 807260
10 March 1999
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 804024
22 June 1997
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 84394
25 April 1997
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1101366
26 February 1997
Re-Inspection · Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1093703
2 January 1997
Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1105033
28 May 1996
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1191425
28 March 1996
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1085946
27 February 1996
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 885729
10 July 1995
Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 883348
13 April 1995
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 850875
29 March 1995
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1145617
28 February 1995
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 853457
29 August 1994
Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1177129
4 May 1994
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1169619
22 March 1994
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 858884
2 March 1994
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 858880
21 June 1993
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 847268
27 May 1993
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 962000
3 March 1993
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 838622
12 August 1992
Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1267347
27 May 1992
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 955977
27 May 1992
Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1270040
7 April 1992
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 946679
4 March 1992
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1008958
7 March 1991
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1211034
11 October 1990
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 913518
12 June 1990
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1222179
12 June 1990
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1248750
11 May 1990
Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 913604
1 May 1990
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 925951
7 March 1990
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1213888
28 March 1989
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1352891
9 March 1989
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 893876
10 March 1988
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1033375
3 March 1988
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1028733
20 March 1987
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1018159
16 March 1987
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1322939
1 April 1986
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1304551
12 March 1986
Credit Drydock
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1300084
4 October 1985
Excursion Permit
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1304074
6 March 1985
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1289665
Deficiency record · 141
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 November 2024
Resolved
Each boiler, including superheater, reheater, economizer, auxiliary boiler, low-pressure heating boiler, and unfired steam boiler, must be available for examination by the marine inspector at intervals specified by table 1 to § 61.05-10, and more often, if necessary, to determine that the complete unit is in a safe and satisfactory condition.
Boiler must undergo a hydrostatic test of 1.25x the MAWP (50psi) and be held for 5-10min to the satisfaction of the attending marine inspector. Boiler is not to be used until satisfactory test is complete. Low water switch must also be tested.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 20 September 2023
Resolved
Gauges to indicate engine lubricating oil pressure shall be provided for all propulsion engines and be located as to be in the view of operator. STBD main diesel engine's oil pressure gauge was inoperable at the operating station. Vessel is to provide a properly working oil pressure gauge at the operating station.
46 CFR 182.20-5(B)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 20 September 2023
Resolved
Machinery shall be installed in a manner to provide adequate protection against machinery failure. STBD ship service generator's oil pressure gauge was inoperable. Vessel is to provide a properly functioning STBD generator oil pressure gauge.
46 CFR 182.01-5(a)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 May 2023
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its design limitations. Jacket water coolant level gauge on port engine found with vice grip holding the level indicator in high position. Spring which reflects appropriate level and signals alarm is being prohibited in the full position. 46CFR119.200(a)
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 June 2022
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Open electrical wiring was found on stbd aft main deck.
09 - Working and Living Conditions › 091 - Living Conditions › No direct openings into sleeping rooms cargo/mach.
Issued 23 June 2022
Resolved
Where seats are in rows, the seats must be secured to a deck or bulkhead. The benches on the top deck are not secured to the deck. Secure the benches to the deck or have them removed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 23 June 2022
Resolved
All equipment, including switches, fuses, lampholders, etc., shall be of a type designed for the potential involved and so identified. The switches on the main switchboard are not labeled.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 23 June 2022
Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Starboard side battery installation is corroded.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 June 2022
Resolved
Heating boilers and their associated piping and fittings shall be tested or examined every three years. The boiler and associated piping was last inspected more than three years ago (November 2018). Make the system available for inspection prior to using the boiler.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 23 June 2022
Resolved
Fixed ballast may not be removed from a vessel or relocated unless approved by the Coast Guard Marine Safety Center. However, ballast may be temporarily moved for vessel examination or repair if done under the supervision of the [name withheld] stability letter does not show added permanent ballast added in Void #2 & #3. Remove permanent ballast or submit for approval through MSC to receive amendment of stability letter.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 10 February 2022
Resolved
Crop and renew wasted pipe in E/R.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 10 February 2022
Resolved
Crop and renew wasted bulkhead in bathroom/lifejacket locker.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 10 February 2022
Resolved
Crop and renew holes on side shell on 02 deck.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 10 February 2022
Resolved
Replace 03 broken windows.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 9 April 2019
Resolved
1. Remove concrete patch/seal in aft compartment.
2. Renew paint on upper deck.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 April 2019
Resolved
Install locking device to potable water fill pipe.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 2 November 2017
Resolved
Replace grabline for life ring buoy (stbd side).
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 2 November 2017
Resolved
Install bracket for waterlight (stbd side).
Navigation › Piloting/Steering › Coast Guard Light List
Issued 2 November 2017
Resolved
Provide 2017 Light List.
Electrical › Electric Generation Source (service) › Ground Indicator
Issued 2 November 2017
Resolved
Trace and correct ground on DC system.
Electrical › Electric Generation Source (service) › Ground Detection
Issued 2 November 2017
Resolved
Install ground detection for AC system by next drydock.
Communications › Radio Communications › VHF Radiotelephone
Issued 9 November 2016
Resolved
Install MMSI number into VHF radio.
Engineering › Diesel Engine (propulsion-electric) › Exhaust Manifold
Issued 9 November 2016
Resolved
Replace lagging on Starboard exhaust manifold.
Electrical › Electrical Distribution System (service) › Ground Indicator
Issued 9 November 2016
Resolved
Replace light guard on the ground detection.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 9 November 2016
Resolved
Label emergency escape in the engine room.
Fire Fighting › Structural - A Class Divisions › Accommodation Spaces
Issued 4 November 2015
Resolved
AM01: Install means to seperate carpet coming through fire door.
Construction/Loadline › Structures › Deck Plating
Issued 10 November 2010
Resolved
Repair bit on starboard side of second deck.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 10 November 2008
Resolved
Ensure all navigation lights meet UL standard 1104 IAW 46 CFR 120.420.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 27 October 2008
Resolved
Prove proper servicing of all portable fire extinguishers onbard vessel.
Electrical › Electric Generation Source (service) › Switch
Issued 27 October 2008
Resolved
Determine cause of port side generator fire and submit tech report outlining the same.
Electrical › Electric Generation Source (service) › Switch
Issued 27 October 2008
Resolved
Prove proper operation of port generator underload in the presence of a Marine Inspector.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 12 February 2008
Resolved
Company has not completed initial EAP training on new employees.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 12 February 2008
Resolved
Company not conducting DOT required Drug testing background checks.
Electrical › Lighting (service) › Outlet Box
Issued 20 December 2007
Resolved
Provide guards in way of all fixed lighting in engine compartment.
Fire Fighting › Fire Pumps › Arrangement
Issued 20 December 2007
Resolved
Replace flexible hose in way of engine driven fire/bilge pump.
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 20 December 2007
Resolved
Provide non-conducting mat in front of DC distribution panel.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 20 December 2007
Resolved
Prove proper operation of emergency lighting in engine compartment and second deck forward.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 20 December 2007
Resolved
Prove proper operation of vessels anchor light.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 20 December 2007
Resolved
Prove all navigation lights meet requirements of UL 1104 IAW 46CFR120.420.
Electrical › Lighting (service) › Outlet Box
Issued 20 December 2007
Resolved
Replace globe in way of fixed lighting behind second deck bar.
Construction/Loadline › Hull › Side Shell
Issued 20 December 2007
Resolved
Ensure port and starboard loading doors have the ability to close fully.
Electrical › Electric Supply System (service) › Battery Installation
Issued 20 December 2007
Resolved
Secure battery beneath operating station.
Communications › Alarms/Indicators › High Water Alarm
Issued 20 December 2007
Resolved
Remount high water alarm located in shaft alley.
Engineering › Shafting/Propeller Arrangements › Stern Gland
Issued 20 December 2007
Resolved
Secure leak IWO starboard shaft seal (tighten packing).
Stability › Watertight Integrity › General
Issued 20 December 2007
Resolved
Adjust bottom starboard dog IWO watertight door between shaft alley and engine compartment.
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 20 December 2007
Resolved
Install caps over valves IWO jacket water cooling piping for port and starboard engine.
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 20 December 2007
Resolved
Properly mount sanitary pump (sat water) toilet flush located in engine compartment.
Operations/Management › Drills/Instruction › Not Conducted
Issued 20 December 2007
Resolved
Conduct security drills with crew and properly log the same.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 4 October 2007
Resolved
Provide 18 adult life jackets.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 4 October 2007
Resolved
Replace broken Emergency light fixture on second deck.
Electrical › Lighting (service) › Lighting Fixture
Issued 4 October 2007
Resolved
Install light bulbs in sockets on main deck overhead.
Engineering › Diesel Engine (propulsion-direct drive) › Gear, Timing
Issued 4 October 2007
Resolved
Install guard around moving parts in front of generator.
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 4 October 2007
Resolved
provide upper support for water pressure tank stbd side engine room.
Engineering › Freshwater System (jacketwater cooling) › Reciever
Issued 4 October 2007
Resolved
repair leak on port main engine heat exchanger.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 12 November 2004
Resolved
Provide 25 additional adult and 9 child PFDs for a total of 567 adult and 57 child. Until complete, vessel is limited to 542 adaults and 48 children.
Navigation › Piloting/Steering › Compass Deviation Table
Issued 12 November 2004
Resolved
Provide a recently calculated magnetic compass deviation table.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 12 November 2004
Resolved
Properly mark PFD stowage with minimum 2 inch lettering, and upper deck capacity with minimum 1 inch lettering.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 12 November 2004
Resolved
Secure soda system CO2 bottles in fwd hold.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 12 November 2004
Resolved
Secure soda system compressor in fwd hold.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 12 November 2004
Resolved
Prove porper operation of both E-lights on main deck midships.
Lifesaving › Lifejacket/PFD (Type I)
Issued 26 March 2004
Resolved
Rejected 161 lifejackets, Vessel is limited to 390 adult and 39 children until proper amount of PFD's are provided. LEGACY COMPONENT DESC: Condition
Communications › Alarms/Indicators
Issued 26 March 2004
Resolved
Deckhand must make a 30 minute round of the shaft alley space until a high level bilge sensor is properly installed and tested. LEGACY COMPONENT DESC: Bilge Alarm
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 26 March 2004
Resolved
Prior to carrying passengers properly repair excessive leaking of both shaft logs/shaft packing.
Fire Fighting › Fire Pumps › Capacity
Issued 26 March 2004
Resolved
Prove proper operation of electric fire pump (low PSI) LEGACY COMPONENT DESC: Capacity
Communications › Alarms/Indicators
Issued 26 March 2004
Resolved
Prove proper operation of Lube oil PSI gauges/alarm system. LEGACY COMPONENT DESC: Lube Oil Low Pressure Alarm
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 26 March 2004
Resolved
Properly repair lazarette hatch. (doesn't dog down)
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 26 March 2004
Resolved
Properly repair shaft alley space hatch. (doesn't dog down)
Electrical › Electrical Distribution System (service)
Issued 26 March 2004
Resolved
Provide battery box covers for both generator batteries.
Engineering › Fuel Oil Service System › Filter
Issued 26 March 2004
Resolved
Properly repair stbd generator fuel leak on inlet side of fuel filter.
Engineering › Lubricating Oil Service System
Issued 26 March 2004
Resolved
Properly repair oil leak on stbd generator oil PSI sensor. Leak is being caught in a drippan and the pan is full and overflowing.
Engineering › Fuel Oil Service System › Piping
Issued 26 March 2004
Resolved
Properly repair fuel leak on stbd generator fuel return line.
Engineering › Fuel Oil Service System › Piping
Issued 26 March 2004
Resolved
Properly repair fuel oil leak on port generator fuel oil return line.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 26 March 2004
Resolved
Prove proper operation of Ground detection system on both swithboards.
Electrical › Electrical Distribution System (service)
Issued 26 March 2004
Resolved
Prove proper operation of voltmeter on switchboard. LEGACY COMPONENT DESC: Wiring
Electrical › Electric Generation Source (service)
Issued 26 March 2004
Resolved
Prove proper operation of frequency meter on switchboard.
Construction/Loadline › Penetrations
Issued 26 March 2004
Resolved
Properly repair through hull side shell valve for MDE raw water discharge. Both MDE's
Construction/Loadline › Structures › Door
Issued 26 March 2004
Resolved
Properly repair WTD in engine room leading to shaft alley.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 26 March 2004
Resolved
Remove unfused/unprotected extension cord wired directly to bus bar in engine room electrical panel.
Engineering › Fuel Oil Service System
Issued 10 March 2003
Resolved
Renew return fuel line for both port and starboard main engines.
Electrical › Electric Supply System (service)
Issued 10 March 2003
Resolved
Renew battery starting leads to port generator.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 10 March 2003
Resolved
Tighten fuel supply connection for starboard main engine.
Lifesaving › Lifejacket/PFD (Type I)
Issued 10 March 2003
Resolved
Provide 18 additional adult life jackets. Vessel is limited to 549 total persons on board until additional jackets are purchased.
Electrical › Electrical Distribution System (service)
Issued 10 March 2003
Resolved
Provide rubber matting in front of the DC switchboard.
Lifesaving › Lifejacket/PFD (Type I)
Issued 11 March 2002
Resolved
Replace 107 adult sized type I lifejacket. LEGACY COMPONENT DESC: Condition
Fire Fighting › Fire Pumps
Issued 11 March 2002
Resolved
Provide calibrated gauge for fire pumps to prove 50 psi. LEGACY COMPONENT DESC: Pressure
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 11 March 2002
Resolved
Repair fuel leak on port MDE Strainer. LEGACY COMPONENT DESC: fuel strainer
Engineering
Issued 11 March 2002
Resolved
Repair fuel leak on fuel level indicator piping. LEGACY COMPONENT DESC: Fuel level indicator piping
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 11 March 2002
Resolved
Rudder Angle Indicator - Unknown Cause/Condition
Engineering
Issued 28 March 2001
Resolved
PROPERLY REPAIR RPM GAUGE FOR STBD MDE NLT 06APR01.
Engineering
Issued 28 March 2001
Resolved
DOUBLE CLAMP PROT MDE RAW WATER HOSE NLT 06APR01
Construction/Loadline
Issued 28 March 2001
Resolved
PRIOR TO CARRYING PASSENGERS MAKE PROPER REPAIRS TO WATERTIGHT DOOR BETWEENENGINE ROOM AND HOLDING TANK SPACE.
Fire Fighting
Issued 28 March 2001
Resolved
PROVIDE FIRE PUMP DISCHARGE PRESSURE GAUGE NLT06APR01.
Engineering
Issued 28 March 2001
Resolved
PROPERLY REPAIR LUBE OIL PRESSURE GAUGES FOR BOTH MDE'S PRIOR TO CARRYING PASSENGERS.
Engineering
Issued 28 March 2001
Resolved
PROPERLY LABEL AND REPAIR EMERGENCY FUEL SHUTOFFS, NLT 06APR01.
Construction/Loadline
Issued 14 March 2001
Resolved
Submit satisfactory repair proposal for wasted deck/sideshell in way of starboard fantail.
Construction/Loadline
Issued 14 March 2001
Resolved
Provide gauging report for hull plating in way of engineroom and shaft alley compartment.
Construction/Loadline
Issued 25 April 2000
Resolved
REMOVE OIL AND WATER FROM THE BILGES IN THE ENGINEROOM, VOID AFT OF THE ENGINEROOM AND LAZARETTE.
Electrical
Issued 25 April 2000
Resolved
REPLACE ELECTRICAL CABLE IN THE FORWARD STOREROOM WITH PROPER MARINE TYPE CABLE AND PERMANENTLY MOUNT THE ELECTRICAL OUTLET BOX.
Construction/Loadline
Issued 25 April 2000
Resolved
PLACE HAILING PORT ON THE STERN.
Lifesaving
Issued 25 April 2000
Resolved
MAKE VESSEL AVAILABLE WITH CREW TO CONDUCT UNDERWAY DRILLS TO THE SATISFACTION OF AN ATTENDING USCG MARINE INSPECTOR.
Fire Fighting
Issued 13 April 1999
Resolved
VESSEL LIMITED TO 149 PASSENGERS PENDING MODIFICATIONS PLAN APPROVAL FROM HEADQUARTERS.
Documentation
Issued 10 March 1999
Resolved
SUBMIT COMPLETE PLANS FOR THE MODIFICATIONS MADE TO THE VESSEL. PLANS TO INCLUDE ALL MATERIAL SPECIFICATIONS AND DETAILS FOR THE HEATING BOILER, PIPING, HOSE, ELECTRICAL WIRING, BULKHEAD PENETRATIONS,ELECTRICAL FIXTURES ETC.
Accommodation/Occupational Safety
Issued 10 March 1999
Resolved
UPON PLAN APPROVAL OF MODIFICATIONS PROPERLY SECURE CABLE RUNS, REMOVE COMBUSTIBLES FROM CONCEALED SPACES, PROPERLY FIT UP HEATER ROOM FIRE DOOR, PROPERLY SECURE CABLE RUNS TO ELECTRICAL FIXTURES, PROVIDE FIXED FIRE SYSTEM FOR THE OIL FIRED HEATER ROOM, ETC.
Engineering
Issued 10 March 1999
Resolved
PROVIDE MANUALLY OPERATED REMOTE FUEL SHUT OFF VALVE TO CLOSE AGAINST THE FUEL FLOW IN THE FUEL SUPPLY LINE AT THE TANK. THE SHUT OFF VALVE MUST BE OPERABLE FROM OUT SIDE THE COMPARTMENT IN WHICH THE VALVE IS LOCATED. IAW 46 CFR 119.455
Electrical
Issued 26 February 1997
Resolved
PROPERLY DEAD END THE LOOSE ELECTRICAL WIRES IN THE REFFER COMPARTMENT.
Documentation
Issued 26 February 1997
Resolved
PROVIDE PROOF OF COMPLIANCE WITH THE DRUG TESTING REGULATIONS CONTAINED IN 46 CR PART 16.
Accommodation/Occupational Safety
Issued 26 February 1997
Resolved
RENEW THE DOOR LATCHES ON THE PORT AND STARBOARD MAIN DECK AFT DOORS.
Accommodation/Occupational Safety
Issued 26 February 1997
Resolved
RENEW THE DOOR CLOSURE DEVICE ON THE SECCOND DECK FORWARD SET OF DOUBLE DOORS.
Fire Fighting
Issued 26 February 1997
Resolved
PLACE SPANNER WRNECHES AT ALL FIRE STATIONS.
Documentation
Issued 26 February 1997
Resolved
PROVIDE AND PROPERLY POST A MARPOL ANNEX I PLACARD.
Electrical
Issued 26 February 1997
Resolved
PROVE PROPER OPERATION OF ALL EMERGENCY LIGHTING FIXTURES.
Construction/Loadline
Issued 26 February 1997
Resolved
MAKE WATERTIGHT THE PIPE PASSING THROUGH BULKHEAD FROM #3 TO #4 STORAGE COMPARTMENT.
Accommodation/Occupational Safety
Issued 26 February 1997
Resolved
PROVE PROPER OPERATION OF THE MSD SYSTEM.
Navigation
Issued 26 February 1997
Resolved
PROVE PROPER OPERATION OF THE VESSELS WHISTLE.
Documentation
Issued 26 February 1997
Resolved
PROVIDE A VALID CERTIFICATE OF DOCUMENTATION.
Lifesaving
Issued 26 February 1997
Resolved
CONDUCT UNDERWAY EMERGENCY DRILLS INCLUDING MAN OVERBOARD, FIRE AND ABANDONSHIP WITH ALL NORMALLY ASSIGNED CREWMEMBERS.
Lifesaving
Issued 26 February 1997
Resolved
PROVIDE A RING BUOY WATERLIGHT LANYARD OF 3 TO 6 FEET IN LENGTH WITH CLIP.
Lifesaving
Issued 27 February 1996
Resolved
REPAIR OR REPLACE TWO RING BUOYS (HOLES & BROKEN LINE).
Lifesaving
Issued 27 February 1996
Resolved
THE MASTER SHALL CONDUCT EMERGENCY DRILLS (FIRE, MAN OVERBOARD, FLOODING, LOSS OF PROPULSION AND ABANDON SHIP) WITH ALL NORMALLY ASSIGNED VESSEL CREWMWMBERS IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR.
Navigation
Issued 27 February 1996
Resolved
STERN LIGNT BULB REPLACED. BULB BURNT OUT.
Accommodation/Occupational Safety
Issued 27 February 1996
Resolved
MAKE PERMANENT REPAIR TO WOODEN DOOR LOCATED ON SECOND DECK (HINGES, CASING).
Engineering
Issued 27 February 1996
Resolved
BRING EXHAUST SYSTEM INTO COMPLIANCE WITH 46 CFR 182.20-15 (EXHAUST LAGGINGMISSING).
Lifesaving
Issued 27 February 1996
Resolved
12 LIFE JACKETS WERE REJECTED; 10 ADULT - 2 REPLACED WITH NEW 8 RENEWED REFLECTIVE TAPE, 2 CHILD - RPELACED WITH NEW.
Lifesaving
Issued 27 February 1996
Resolved
WATER LIGHT HAD MISSING PACKING AROUND BATTERY. ITEM REPLACED WITH NEW UNIT.
Lifesaving
Issued 28 February 1995
Resolved
REPLACE TWO (2) CHILDREN AND THREE (3) ADULT PERSONAL FLOATATION DEVICES PRIOR TO OPERATION.
Engineering
Issued 28 February 1995
Resolved
PLACE PROTECTIVE GUARDS ON BOTH DIESEL GENERATORS NO LATER THAN 28 MAR 95.
Deck/Cargo
Issued 28 February 1995
Resolved
PLACE PROTECTIVE GUARDS ON AIR COMPRESSOR NO LATER THAN 28 MARCH 1995.
Lifesaving
Issued 22 March 1994
Resolved
SECURE ALL LOOSE GEAR IN AFT STORE ROOM PRIOR TO OPERATING WITH PASSENGERS.
Electrical
Issued 22 March 1994
Resolved
INSTALL MATTING IN FRONT OF MAIN ELECTRICAL SWITCHBOARD IN ENGINE ROOM.
Navigation
Issued 2 March 1994
Resolved
REPAIR, REPLACE OR REMOVE INOPERABLE "SYTEX" RADAR NO LATER THAN 02 APRIL 1994. DEFICIENCY TO BE CARRIED OUT TO THE SATISFACTION OF THE COGNIZANT OCMI.
Documentation
Issued 3 March 1993
Resolved
PROVIDE REVISED ELECTRICAL PLANS INDICATING INSTALLATION OF NEW GENERATORS PRIOR TO PLACING GENERATORS IN SERVICE.
Electrical
Issued 3 March 1993
Resolved
REPAIR AND PROVE OPERATION OF PORT GENERATOR PRIOR TO PLACING GENERATOR IN SERVICE.
Lifesaving
Issued 3 March 1993
Resolved
PRIOR TO CARRYING PASSENGERS THE MASTER SHALL CONDUCT EMERGENCY DRILLS INCLUDING MAN OVERBOARD, FIRE, FLOODING, LOSS OF PROPULSION, AND ABANDON SHIP WITH ALL NORMALLY ASSIGNED VESSEL CREWMEMBERS.
Lifesaving
Issued 3 March 1993
Resolved
THE MASTER SHALL CONDUCT EMERGENCY DRILLS INCLUDING MAN OVERBOARD, FIRE, FLOODING, LOSS OF PROPULSION, AND ABANDON SHIP WITH ALL NORMALLY ASSIGNED VESSEL CREWMEMBERS IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR.
Navigation
Issued 7 March 1990
Resolved
REMOVE HYDRAULIC FLUID IN AFTER STEERING COMPARTMENTS
Lifesaving
Issued 7 March 1990
Resolved
REPLACE OUTDATED 4 HAND HELD ORANGE FLARES
Deck/Cargo
Issued 7 March 1990
Resolved
CLEAN BILGE STRAINERS IN AFTER STORE ROOM COMPARTMENT.
Electrical
Issued 7 March 1990
Resolved
REPLACE BATTERY BOX COVER FOR PORT GENERATOR.
Construction/Loadline
Issued 7 March 1990
Resolved
REPLACE GLASS IN BROKEN WINDOWS ON MAIN DECK HOUSE.
Lifesaving
Issued 9 March 1989
Resolved
SIX ADULT PERSONAL FLOTATION DEVICES DID NOT HAVE THE REQUIRED REFLECTIVE MATERIAL.
Fire Fighting
Issued 9 March 1989
Resolved
PRESSURE GAUGE FOR THE FIREPUMP WAS INOPERATIVE AT THE TIME OF THE INSPEC- TION.
Casualty record · 2
3 July 2006Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 2836634
27 October 2008Routine · role: Involved in a Marine Casualty · activity 3352866
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.