MAURY USCG vessel records
← All vessels

BAY STATE

BAY STATE is a 1976 passenger vessel (inspected). The Coast Guard has recorded 17 inspections since 2016, most recently in March 2026, along with 25 deficiencies and 2 casualty investigations between 2006 and 2008.

Records from 2006 to 2026. Most recent: inspection, 25 March 2026.

Built
1976
Last inspected
25 March 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the casualty record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 25 March 2026
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDE6673
Flag
UNITED STATES
Maury page id
psix-48721

Documentation record

Registered dimensions (L × B × D)97.8 ft × 27.1 ft × 7.6 ft
Registered tonnagegross 98 / net 74
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGAMAGE SHIPBUILDERS INC · SOUTH BRISTOL, ME, UNITED STATES · built 1976
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portLIBERTY ISLAND, NY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 20 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it98 - Regulatory (Subpart C or D), Gross Ton
74 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

17 inspections, each with its date, unit and type; 25 deficiencies with the resolution recorded against each; 2 casualty investigations, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 17

25 March 2026 Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8331886
27 October 2025 In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8257671
2 September 2025 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8225255
20 November 2024 In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8038115
18 September 2024 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7985480
20 March 2024 Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7875964
20 September 2023 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7785840
5 May 2023 Deficiency Check · In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7681690
23 June 2022 Deficiency Check · COI Inspection · Administrative Inspection · Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7463943
10 February 2022 Deficiency Check · Internal Structural Exam · Hull Examination · Examination of Repairs
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7394155
27 October 2020 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7084789
30 October 2019 MTSA Verification · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6845170
9 April 2019 Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6658865
1 November 2018 In-Service Inspection · Annual Inspection · Administrative Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6572519
2 November 2017 Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6299329
4 April 2017 Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6117077
9 November 2016 Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6038076

Deficiency record · 25

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 November 2024 Resolved
Each boiler, including superheater, reheater, economizer, auxiliary boiler, low-pressure heating boiler, and unfired steam boiler, must be available for examination by the marine inspector at intervals specified by table 1 to § 61.05-10, and more often, if necessary, to determine that the complete unit is in a safe and satisfactory condition. Boiler must undergo a hydrostatic test of 1.25x the MAWP (50psi) and be held for 5-10min to the satisfaction of the attending marine inspector. Boiler is not to be used until satisfactory test is complete. Low water switch must also be tested.
Action required: 705 - Other - as specified
Due 20 November 2024
Resolved 25 November 2024
Resolution: O/O completed satisfactory hydrostatic test of boiler and tested low water switch, a/s.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 20 September 2023 Resolved
Gauges to indicate engine lubricating oil pressure shall be provided for all propulsion engines and be located as to be in the view of operator. STBD main diesel engine's oil pressure gauge was inoperable at the operating station. Vessel is to provide a properly working oil pressure gauge at the operating station. 46 CFR 182.20-5(B)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2023
Resolved 29 September 2023
Resolution: Verified gauge.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 20 September 2023 Resolved
Machinery shall be installed in a manner to provide adequate protection against machinery failure. STBD ship service generator's oil pressure gauge was inoperable. Vessel is to provide a properly functioning STBD generator oil pressure gauge. 46 CFR 182.01-5(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2023
Resolved 29 September 2023
Resolution: Verified guage.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 May 2023 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its design limitations. Jacket water coolant level gauge on port engine found with vice grip holding the level indicator in high position. Spring which reflects appropriate level and signals alarm is being prohibited in the full position. 46CFR119.200(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2023
Resolved 19 May 2023
Resolution: Attended, verified new installation of level indicator. Tested alarms on bridge, all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 June 2022 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Open electrical wiring was found on stbd aft main deck.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2022
Resolved 13 July 2022
Resolution: Open wire capped off and secured.
09 - Working and Living Conditions › 091 - Living Conditions › No direct openings into sleeping rooms cargo/mach.
Issued 23 June 2022 Resolved
Where seats are in rows, the seats must be secured to a deck or bulkhead. The benches on the top deck are not secured to the deck. Secure the benches to the deck or have them removed.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2022
Resolved 13 July 2022
Resolution: All temporary bench seating removed from vessel.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 23 June 2022 Resolved
All equipment, including switches, fuses, lampholders, etc., shall be of a type designed for the potential involved and so identified. The switches on the main switchboard are not labeled.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2022
Resolved 13 July 2022
Resolution: Breakers identified were labeled correctly.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 23 June 2022 Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Starboard side battery installation is corroded.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2022
Resolved 13 July 2022
Resolution: Battery cables and terminals cleaned of corrosion.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 June 2022 Resolved
Heating boilers and their associated piping and fittings shall be tested or examined every three years. The boiler and associated piping was last inspected more than three years ago (November 2018). Make the system available for inspection prior to using the boiler.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 19 October 2022
Resolution: Hydro test boiler sat. see general information for specifics.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 23 June 2022 Resolved
Fixed ballast may not be removed from a vessel or relocated unless approved by the Coast Guard Marine Safety Center. However, ballast may be temporarily moved for vessel examination or repair if done under the supervision of the [name withheld] stability letter does not show added permanent ballast added in Void #2 & #3. Remove permanent ballast or submit for approval through MSC to receive amendment of stability letter.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 8 November 2023
Resolution: Vessel received new stability letter
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 10 February 2022 Resolved
Crop and renew wasted pipe in E/R.
Action required: 705 - Other - as specified
Due 25 May 2022
Resolved 23 June 2022
Resolution: Repair sat.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 10 February 2022 Resolved
Crop and renew wasted bulkhead in bathroom/lifejacket locker.
Action required: 705 - Other - as specified
Due 25 May 2022
Resolved 23 June 2022
Resolution: Repair sat.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 10 February 2022 Resolved
Crop and renew holes on side shell on 02 deck.
Action required: 705 - Other - as specified
Due 25 May 2022
Resolved 23 June 2022
Resolution: Reapir sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 10 February 2022 Resolved
Replace 03 broken windows.
Action required: 705 - Other - as specified
Due 25 May 2022
Resolved 30 June 2022
Resolution: Confirmed the glass was replaced.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 9 April 2019 Resolved
1. Remove concrete patch/seal in aft compartment. 2. Renew paint on upper deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 September 2019
Resolution: concrete was removed, inspected compartment all SAT.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 April 2019 Resolved
Install locking device to potable water fill pipe.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 September 2019
Resolution: Locking device intalled.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 2 November 2017 Resolved
Replace grabline for life ring buoy (stbd side).
Action required: 705 - Other - as specified
Due 1 December 2017
Resolved 12 December 2017
Resolution: Visually confirmed new grabline.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 2 November 2017 Resolved
Install bracket for waterlight (stbd side).
Action required: 705 - Other - as specified
Due 1 December 2017
Resolved 12 December 2017
Resolution: Visually confirmed proper mounting of bracket.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 2 November 2017 Resolved
Provide 2017 Light List.
Action required: 705 - Other - as specified
Due 1 December 2017
Resolved 26 February 2018
Resolution: Visually confirmed new 2018 Light List publication.
Electrical › Electric Generation Source (service) › Ground Indicator
Issued 2 November 2017 Resolved
Trace and correct ground on DC system.
Action required: 705 - Other - as specified
Due 1 December 2017
Resolved 12 December 2017
Resolution: Visually confirmed cleared ground on DC system.
Electrical › Electric Generation Source (service) › Ground Detection
Issued 2 November 2017 Resolved
Install ground detection for AC system by next drydock.
Due 4 April 2019
Resolved 12 December 2017
Resolution: Visually confirmed properly installed ground detection.
Communications › Radio Communications › VHF Radiotelephone
Issued 9 November 2016 Resolved
Install MMSI number into VHF radio.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 November 2016
Resolved 16 November 2016
Resolution: Owners provided picture of MMSI number programmed into VHF radio.
Engineering › Diesel Engine (propulsion-electric) › Exhaust Manifold
Issued 9 November 2016 Resolved
Replace lagging on Starboard exhaust manifold.
Condition: Improper Installation
Due 9 November 2016
Resolved 9 November 2016
Resolution: Lagging was installed during inspection.
Electrical › Electrical Distribution System (service) › Ground Indicator
Issued 9 November 2016 Resolved
Replace light guard on the ground detection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 November 2016
Resolved 16 November 2016
Resolution: Operator provided picture showing replacement guard.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 9 November 2016 Resolved
Label emergency escape in the engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 November 2016
Resolved 16 November 2016
Resolution: Operator provided photo of emergency escape labeled.

Casualty record · 2

3 July 2006Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 2836634
27 October 2008Routine · role: Involved in a Marine Casualty · activity 3352866
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.