Records from 2006 to 2026. Most recent: inspection, 25 March 2026.
Everything above is free. The detail below — the inspection history, the deficiency record, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 17
25 March 2026
Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8331886
27 October 2025
In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8257671
2 September 2025
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8225255
20 November 2024
In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8038115
18 September 2024
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7985480
20 March 2024
Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7875964
20 September 2023
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7785840
5 May 2023
Deficiency Check · In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7681690
23 June 2022
Deficiency Check · COI Inspection · Administrative Inspection · Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7463943
10 February 2022
Deficiency Check · Internal Structural Exam · Hull Examination · Examination of Repairs
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7394155
27 October 2020
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7084789
30 October 2019
MTSA Verification · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6845170
9 April 2019
Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6658865
1 November 2018
In-Service Inspection · Annual Inspection · Administrative Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6572519
2 November 2017
Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6299329
4 April 2017
Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6117077
9 November 2016
Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6038076
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 November 2024
Resolved
Each boiler, including superheater, reheater, economizer, auxiliary boiler, low-pressure heating boiler, and unfired steam boiler, must be available for examination by the marine inspector at intervals specified by table 1 to § 61.05-10, and more often, if necessary, to determine that the complete unit is in a safe and satisfactory condition.
Boiler must undergo a hydrostatic test of 1.25x the MAWP (50psi) and be held for 5-10min to the satisfaction of the attending marine inspector. Boiler is not to be used until satisfactory test is complete. Low water switch must also be tested.
Action required: 705 - Other - as specified
Due 20 November 2024
Resolved 25 November 2024
Resolution: O/O completed satisfactory hydrostatic test of boiler and tested low water switch, a/s.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 20 September 2023
Resolved
Gauges to indicate engine lubricating oil pressure shall be provided for all propulsion engines and be located as to be in the view of operator. STBD main diesel engine's oil pressure gauge was inoperable at the operating station. Vessel is to provide a properly working oil pressure gauge at the operating station.
46 CFR 182.20-5(B)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2023
Resolved 29 September 2023
Resolution: Verified gauge.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 20 September 2023
Resolved
Machinery shall be installed in a manner to provide adequate protection against machinery failure. STBD ship service generator's oil pressure gauge was inoperable. Vessel is to provide a properly functioning STBD generator oil pressure gauge.
46 CFR 182.01-5(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2023
Resolved 29 September 2023
Resolution: Verified guage.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 May 2023
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its design limitations. Jacket water coolant level gauge on port engine found with vice grip holding the level indicator in high position. Spring which reflects appropriate level and signals alarm is being prohibited in the full position. 46CFR119.200(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2023
Resolved 19 May 2023
Resolution: Attended, verified new installation of level indicator. Tested alarms on bridge, all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 June 2022
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Open electrical wiring was found on stbd aft main deck.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2022
Resolved 13 July 2022
Resolution: Open wire capped off and secured.
09 - Working and Living Conditions › 091 - Living Conditions › No direct openings into sleeping rooms cargo/mach.
Issued 23 June 2022
Resolved
Where seats are in rows, the seats must be secured to a deck or bulkhead. The benches on the top deck are not secured to the deck. Secure the benches to the deck or have them removed.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2022
Resolved 13 July 2022
Resolution: All temporary bench seating removed from vessel.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 23 June 2022
Resolved
All equipment, including switches, fuses, lampholders, etc., shall be of a type designed for the potential involved and so identified. The switches on the main switchboard are not labeled.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2022
Resolved 13 July 2022
Resolution: Breakers identified were labeled correctly.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 23 June 2022
Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Starboard side battery installation is corroded.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2022
Resolved 13 July 2022
Resolution: Battery cables and terminals cleaned of corrosion.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 June 2022
Resolved
Heating boilers and their associated piping and fittings shall be tested or examined every three years. The boiler and associated piping was last inspected more than three years ago (November 2018). Make the system available for inspection prior to using the boiler.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 19 October 2022
Resolution: Hydro test boiler sat. see general information for specifics.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 23 June 2022
Resolved
Fixed ballast may not be removed from a vessel or relocated unless approved by the Coast Guard Marine Safety Center. However, ballast may be temporarily moved for vessel examination or repair if done under the supervision of the [name withheld] stability letter does not show added permanent ballast added in Void #2 & #3. Remove permanent ballast or submit for approval through MSC to receive amendment of stability letter.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 8 November 2023
Resolution: Vessel received new stability letter
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 10 February 2022
Resolved
Crop and renew wasted pipe in E/R.
Action required: 705 - Other - as specified
Due 25 May 2022
Resolved 23 June 2022
Resolution: Repair sat.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 10 February 2022
Resolved
Crop and renew wasted bulkhead in bathroom/lifejacket locker.
Action required: 705 - Other - as specified
Due 25 May 2022
Resolved 23 June 2022
Resolution: Repair sat.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 10 February 2022
Resolved
Crop and renew holes on side shell on 02 deck.
Action required: 705 - Other - as specified
Due 25 May 2022
Resolved 23 June 2022
Resolution: Reapir sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 10 February 2022
Resolved
Replace 03 broken windows.
Action required: 705 - Other - as specified
Due 25 May 2022
Resolved 30 June 2022
Resolution: Confirmed the glass was replaced.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 9 April 2019
Resolved
1. Remove concrete patch/seal in aft compartment.
2. Renew paint on upper deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 September 2019
Resolution: concrete was removed, inspected compartment all SAT.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 April 2019
Resolved
Install locking device to potable water fill pipe.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 September 2019
Resolution: Locking device intalled.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 2 November 2017
Resolved
Replace grabline for life ring buoy (stbd side).
Action required: 705 - Other - as specified
Due 1 December 2017
Resolved 12 December 2017
Resolution: Visually confirmed new grabline.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 2 November 2017
Resolved
Install bracket for waterlight (stbd side).
Action required: 705 - Other - as specified
Due 1 December 2017
Resolved 12 December 2017
Resolution: Visually confirmed proper mounting of bracket.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 2 November 2017
Resolved
Provide 2017 Light List.
Action required: 705 - Other - as specified
Due 1 December 2017
Resolved 26 February 2018
Resolution: Visually confirmed new 2018 Light List publication.
Electrical › Electric Generation Source (service) › Ground Indicator
Issued 2 November 2017
Resolved
Trace and correct ground on DC system.
Action required: 705 - Other - as specified
Due 1 December 2017
Resolved 12 December 2017
Resolution: Visually confirmed cleared ground on DC system.
Electrical › Electric Generation Source (service) › Ground Detection
Issued 2 November 2017
Resolved
Install ground detection for AC system by next drydock.
Due 4 April 2019
Resolved 12 December 2017
Resolution: Visually confirmed properly installed ground detection.
Communications › Radio Communications › VHF Radiotelephone
Issued 9 November 2016
Resolved
Install MMSI number into VHF radio.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 November 2016
Resolved 16 November 2016
Resolution: Owners provided picture of MMSI number programmed into VHF radio.
Engineering › Diesel Engine (propulsion-electric) › Exhaust Manifold
Issued 9 November 2016
Resolved
Replace lagging on Starboard exhaust manifold.
Condition: Improper Installation
Due 9 November 2016
Resolved 9 November 2016
Resolution: Lagging was installed during inspection.
Electrical › Electrical Distribution System (service) › Ground Indicator
Issued 9 November 2016
Resolved
Replace light guard on the ground detection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 November 2016
Resolved 16 November 2016
Resolution: Operator provided picture showing replacement guard.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 9 November 2016
Resolved
Label emergency escape in the engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 November 2016
Resolved 16 November 2016
Resolution: Operator provided photo of emergency escape labeled.