← All vessels
AZTEC
Passenger (Inspected) · Passenger Ship class · Built 1970s · USCG Southwest District (CGD-SW) · Other hulls named AZTEC
AZTEC is a 1976 passenger vessel (inspected). The Coast Guard has recorded 91 inspections since 1984, most recently in April 2026, along with 172 deficiencies — 1 with no resolution recorded —, 1 operational control, 1 with no removal date recorded and 1 casualty investigation in 2023.
Records from 1984 to 2026. Most recent: inspection, 2 April 2026.
- Built
- 1976
- Last inspected
- 2 April 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 172 recorded · 1 without a recorded resolution
- Controls
- 1 with no removal date recorded
- Casualties
- 1 investigation · 2023
Identity
572979
WDJ2069
48722
Flag
UNITED STATES
367112690
Maury page id
psix-48722
Inspections, by type
…with no type recorded14
Years with a record
40 calendar years (1984–2026)
The 91 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)62.0 ft × 21.0 ft × 6.2 ft
Registered tonnagegross 66 / net 45
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSEAWAY BOAT CO. · LONG BEACH, CA, UNITED STATES · built 1976
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSAN DIEGO, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 1 May 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it66 - Regulatory (Subpart C or D), Gross Ton
45 - Regulatory (Subpart C or D), Net Ton
45 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDJ2069MMSI 367112690 · active · compulsorily equipped · granted 17 September 2016, expires 17 September 2026
WDD2234MMSI 367112690 · expired · compulsorily equipped · granted 9 May 2006, cancelled 9 July 2016
WBK6371MMSI 366665710 · expired · compulsorily equipped · granted 16 June 1997, cancelled 3 November 2007
WBG5401MMSI not assigned · expired · compulsorily equipped · granted 18 February 1997, cancelled 29 July 2007
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 91
2 April 2026
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8341119
27 October 2025
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8259465
19 May 2025
COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8117813
6 March 2025
Drydock Exam · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8089593
14 May 2024
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7912766
26 March 2024
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7885453
2 August 2023
Administrative Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7758775
1 August 2023
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7780587
11 April 2023
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7667619
11 April 2023
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7674251
27 February 2023
Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7642914
8 August 2022
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7528294
23 May 2022
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7457425
6 October 2021
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7327843
1 June 2021
Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7211770
19 March 2021
Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7161602
22 January 2021
In-Service Inspection · Drydock Extension · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7131846
24 July 2020
Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7015359
27 April 2020
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6993371
8 October 2019
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6830814
31 July 2019
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6769312
31 January 2019
Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6618181
20 March 2018
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6375160
28 July 2017
Annual Survey · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6223839
7 June 2017
Internal Structural Exam · Deficiency Check · Drydock Exam · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6168418
19 September 2016
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6004176
5 June 2014
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4880141
13 June 2012
Simplified Stability Test
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4342931
6 June 2012
DAPI Audit · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4312286
20 January 2011
Deficiency Check · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3929727
1 May 2009
Annual Inspection · DAPI Audit
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3465230
5 January 2009
Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3388784
7 May 2008
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3184998
29 January 2008
Excursion Permit
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3138947
24 May 2007
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2931438
21 February 2007
Deficiency Check · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3296429
15 May 2006
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2687628
2 June 2005
Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2355913
18 March 2005
Administrative Inspection
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2313751
13 January 2005
Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2271940
2 February 2004
Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1998877
21 March 2003
Administrative Inspection
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1760923
11 February 2003
Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1742630
8 January 2003
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1726590
10 December 2002
Excursion Permit
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1716557
1 July 2002
Excursion Permit
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1645169
15 February 2002
Construction Oversight · Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1486735
24 January 2002
Simplified Stability Test
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1481214
14 May 2001
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1397651
12 March 2001
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1366635
27 September 2000
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 219802
7 March 2000
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1397369
3 June 1999
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 804890
30 March 1999
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1399083
3 March 1999
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1365091
22 January 1999
Plan Review "T" Boat
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1123567
17 March 1998
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1419900
7 April 1997
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1094451
25 March 1997
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1380798
18 March 1997
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1437211
18 August 1996
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 180054
19 March 1996
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1407630
17 April 1995
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1380188
4 April 1995
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1152636
6 April 1994
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1179929
27 April 1993
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 831943
31 March 1993
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 832618
15 July 1992
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1266278
30 March 1992
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1265356
25 April 1991
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 900721
19 April 1991
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 907627
11 April 1991
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1225815
10 December 1990
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1243975
10 April 1990
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1224822
26 March 1990
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 923183
18 December 1989
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1215776
13 December 1989
Examination of Repairs · Damage Survey · Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1198848
13 April 1989
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 897524
6 April 1989
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1348875
20 April 1988
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1033252
22 March 1988
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1290869
2 December 1987
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1027507
22 April 1987
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1317005
31 March 1987
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1326692
8 December 1986
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1335992
23 April 1986
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 988735
5 December 1985
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1300172
4 October 1985
Credit Drydock
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1294129
2 July 1985
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 979838
26 April 1985
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1286663
30 November 1984
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1283801
Deficiency record · 172
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 April 2026
Resolved
Vessel must be provided with satisfactory arrangement for draining any watertight compartment. Vessel was unable to demonstrate operation of the fore peak bilge pump. Prove proper operation of the fore peak bilge pump.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 April 2026
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Vessel's life ring buoy is worn. Replace life ring buoy.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 April 2026
Resolved
Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts. Dead end wires found under helm in wheelhouse. Remove dead end wiring and update electrical plans.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 April 2026
Resolved
MI found saltwater exhaust leak on Port MDE stainless steel fitting. Repair leak and notify local OCMI.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 19 May 2025
Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. Vessel FFC Station license was expire. Provide valid FCC cert to local OCMI.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 May 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts. Dead end wires found in bilge under bunk room. Remove dead end wiring and update electrical plans.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 May 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. MI found open circuits slots in the galley breaker panel. Properly encase the breaker panel and notify local OCMI.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 19 May 2025
Resolved
Vessel that have overnight accommodations must have interconnected fire detection system. Smoke detectors would operate but would not turn off until battery was removed. Fix interconnected smoke detection and notify local OCMI.
07 - Fire Safety › N/A - No Subsystem › Fire patrol
Issued 14 May 2024
Resolved
Roving watch system was not operating as designed and operator could not figure out how to properly disarm the system to prevent it from repeatedly going off, which would most likely result in them securing the system instead of using it as required.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 14 May 2024
Resolved
Stern light was found inoperable, restricted to daylight operations until stern light is repaired.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 April 2023
Resolved
All electrical equipment shall be drip proof and protected. Need to remount face cover on distribution panel for pumps in the engine space to satisfaction of the USCG Marine Inspector.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 11 April 2023
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 April 2023
Resolved
Ring buoys must have at least one floating waterlight with lanyard, unless only operating during daylight hours. Floating waterlight not operational during time of inspection. Corrected on the spot
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 11 April 2023
Resolved
EPIRB Tests must be conducted monthly and logged. Last EPIRB tested logged was 25NOV2022. Corrected on the spot
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 8 August 2022
Resolved
PROPERLY SEAL HOLE PENETRATION IN AFT E/R BULKHEAD
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 August 2022
Resolved
REPLACE 02 OOC LIFEJACKETS
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 August 2022
Resolved
ENSURE ALL DEAD END WIRES ARE CAPPED, REMOVED OR A PROPER FIXTURE IS INSTALLED IN LAZ AND CREW BERTHS.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 June 2021
Resolved
Repair stbd propulsion engine wheelhouse shutdown.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 1 June 2021
Resolved
Properly install Fireboy automatic engine shutdown to ensure all engines shutdown regardless of where engine is started.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 June 2021
Resolved
Complete DAPI audit.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 1 June 2021
Resolved
Provide updated Light List and Coast Pilot.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 1 June 2021
Resolved
Properly input GPS & MMSI into VHF-DSC capable radio.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 1 June 2021
Resolved
Install locking device to sewage overboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 June 2021
Resolved
Tighten port main engine sea-strainer piping.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 June 2021
Resolved
Clean grease from under/around oven and exhaust ducts.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 June 2021
Resolved
Replace lifering or repair grab line.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 1 June 2021
No resolution recorded
Onboard a passenger ship, as defined by the Convention for the Safety of Life at Sea, 1974, as amended (SOLAS) (incorporated by reference, see §15.103 of this part), on an international voyage, any person serving as master, chief mate, mate, chief engineer, engineer officer, or any person holding a license, MMD, or MMC and performing duties relating to safety, cargo handling, or care for passengers, must meet the appropriate requirements of Regulation V/2 of the STCW Convention (incorporated by reference, see §15.103 of this part). These individuals must hold documentary evidence to show they meet these requirements. Provide documentary evidence of required STCW training and valid medical certificates for masters and mates prior to operating in Mexican jurisdictional waters with more than 12 passengers.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 24 July 2020
Resolved
A renewal inspection for certification must be completed by the expiration date of the Certificate of Inspection. A written application (CG-3752) for renewal inspection must be submitted to the cognizant [name withheld] completed page 1 of form CG-3752. Complete CG-3752 prior to carrying passengers.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 24 July 2020
Resolved
Replace unapproved flexible non-metallic fuel hoses on generator with hose meeting SAE J-1942 standard.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 24 July 2020
Resolved
Install machinery guard at E/R ventilation fan.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 24 July 2020
Resolved
Repair emergency exit light at forward exit from accom.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 July 2020
Resolved
Replace heat exchanger end bells for exhaust piping cooling water on port & stbd MDE's.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 October 2019
Resolved
Vessel has been identified as having A/C electrical modifications since initial certification. Sector San Diego has vessel's electrical plans on file but current installations do not match what is on file. Provide a one-line electrical drawing for all A/C switchboards and distribution panels. Include all circuit loads, conductor sizes, over current protection, and max panel ratings in amps.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 October 2019
Resolved
Install additional emergency/exit light at the emergency escape.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 October 2019
Resolved
Install cover over junction box in galley stores locker.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 October 2019
Resolved
Install covers over 2 blower fans installed in the galley stores locker.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 August 2019
Resolved
Repair seeping fuel oil pumps on all three main engines.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 August 2019
Resolved
Make repairs to leak on jacket water expansion tank and seeping fuel line.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 1 August 2019
Resolved
Replace destroyed charts with up to date versions.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 August 2019
Resolved
Seal off chine bolt holes to prevent future rot.
Electrical › Electrical Distribution System (service) › Wiring
Issued 20 March 2018
Resolved
Remove extension cables for TVs, and install a permanent installation.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 28 July 2017
Resolved
Provide smoke detectors for the berthing areas
Lifesaving › Lifebuoys › Stowage
Issued 28 July 2017
Resolved
Provide proper install of ring buoy.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 28 July 2017
Resolved
Make lazerette bulkhead watertight.
Engineering › Sea-water System (primary cooling) › Piping
Issued 28 July 2017
Resolved
Reconnect open ended piping in engine room.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 28 July 2017
Resolved
Provide latching doors to electrical boxes.
Electrical › Electrical Distribution System (service) › Wiring
Issued 28 July 2017
Resolved
Trice up hanging wires in the engine room.
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 28 July 2017
Resolved
Port MDE leaks water, repair and demonstrate proper operation.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 28 July 2017
Resolved
Demonstrate proper shutdowns of fireboy.
Fire Fighting › Fire Bucket › Quantity
Issued 28 July 2017
Resolved
Provide three fire buckets.
Engineering › Diesel Engine (propulsion-reduction gear) › Pump, High Pressure (fuel injection)
Issued 21 September 2016
Resolved
Prove proper operation of propulsion system
Lifesaving › Lifefloat › Float Free
Issued 19 September 2016
Resolved
Make starboard life floats float free
Communications › Alarms/Indicators › High Water Alarm
Issued 19 September 2016
Resolved
Prove proper operation of high water alarm in all spaces
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 19 September 2016
Resolved
Service two expired B-II fire extinguishers
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 19 September 2016
Resolved
Service expired pre-engineered fixed fire extinguishing system
Operations/Management › Drills/Instruction › Not Conducted
Issued 19 September 2016
Resolved
Conduct drills in presence of USCG
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 19 September 2016
Resolved
Prove proper operation of Single Side Band Radio prior to operating beyond 20nm from shore.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 19 September 2016
Resolved
Prove proper operation of nav lights prior to operating at night
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 19 September 2016
Resolved
Vessel reduce to 40 adult and 4 child until expired PFD lights are replaced.
Electrical › Electric Generation Source (emergency) › Number of Sources
Issued 19 September 2016
Resolved
Prove proper operation of emergency lighting prior to conducting overnight trips.
Navigation › Piloting/Steering › Marine Charts
Issued 19 September 2016
Resolved
Provide current charts
Navigation › Piloting/Steering › US Coast Pilot
Issued 19 September 2016
Resolved
Provide current coast pilot
Engineering › Bilge Water Management System › Hose
Issued 19 September 2016
Resolved
Provide hose clamp on fwd berthing bilge suction strainer.
Electrical › Electrical Distribution System (service) › Wiring
Issued 19 September 2016
Resolved
Remove dead end wires under nav console
Communications › Radio Communications › VHF Radiotelephone
Issued 19 September 2016
Resolved
Provide emergency broadcast placard IVO helm
Documentation › Certificates/Documents › FCC SSL
Issued 19 September 2016
Resolved
Provide FCC Station license.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 19 September 2016
Resolved
Provide current light list
Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 19 September 2016
Resolved
Provide current alcohol swabs.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 19 September 2016
Resolved
Label both side of emergency escape hatch.
Electrical › Lighting (service) › Lighting Fixture
Issued 19 September 2016
Resolved
Provide cover for starboard E/R aft light fixture.
Electrical › Electric Supply System (service) › Battery Installation
Issued 19 September 2016
Resolved
Properly stow excess batteries in E/R
Electrical › Electric Generation Source (service) › Panelboard
Issued 19 September 2016
Resolved
Remove hazard from Stbd aft E/R panel
Engineering › Fuel Oil Service System › Filter
Issued 19 September 2016
Resolved
Repair leak on port sediment fuel filter.
Electrical › Electrical Distribution System (service) › Wiring
Issued 19 September 2016
Resolved
Remove dead end wires in forepeak
Deck/Cargo › Cargo Stowage › General
Issued 19 September 2016
Resolved
Properly stow helium bottle IAW 49CFR176.200(c)
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 19 September 2016
Resolved
Evaluate plug for powering beer box
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 19 September 2016
Resolved
Replace outlet cover IVO beer box
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 19 September 2016
Resolved
Provide proper rescue platform
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 5 June 2014
Resolved
Prove repair of sten light. Prior to sailing at night.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 5 June 2014
Resolved
Provide proof of first aid kit as per 46CFR160.041.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 5 June 2014
Resolved
Replace "D Cell" batteries in portside lifefloat as per 46CFR184.610.
Communications › Public Address System › Loudspeaker
Issued 5 June 2014
Resolved
Prove proper operation of PA system as per 46CFR184.610.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 5 June 2014
Resolved
Prove proper operation of fixed fire system engine shutdown and override as per 46CFR181.410.
Engineering › Electric Propulsion System › Battery
Issued 5 June 2014
Resolved
Replace faulty battery and prove proper operation of vessel main propulsion as per 46CFR183.350 & 182.200.
Engineering › Fuel Oil Service System › Piping
Issued 5 June 2014
Resolved
Replace in kind fuel oil return line on Center Main Engine as per 46CFR182.720.
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 June 2014
Resolved
Prove proper installation of bridge electrical equipment -IE- wires, distributions panels, operation and installation as per 46CFR183.392 & 183.340.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 6 June 2012
Resolved
Provide UL approved smoke detector for bunk room and IWO galley.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 6 June 2012
Resolved
Provide 3 PML's for lifejackets.
Lifesaving › Inflatable Buoyant Apparatus › Float Free
Issued 6 June 2012
Resolved
Provide proper installation of all lifefloats.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 20 January 2011
Resolved
Relocate fire boy control box prior to next annual inspection scheduled for June 2011.
Navigation › Piloting/Steering › Marine Charts
Issued 7 May 2008
Resolved
Update charts
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 7 May 2008
Resolved
Replace line on ring buoy water light.
Fire Fighting › Fire Bucket › Quantity
Issued 7 May 2008
Resolved
Provide (3) fire buckets of at least 2.5 gallon capacity each with lanyards attached and marked "fire bucket".
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 7 May 2008
Resolved
Provide (1) additional adult PFD onboard for a total of (48) adult PFD's. Vessel restricted to NMT 47 total persons until corrected.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 7 May 2008
Resolved
Clean PFD's that are mildewed as needed.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 24 May 2007
Resolved
Provide light on 1 of the child PFD's. Vessel limited to 4 children until item corrected.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 24 May 2007
Resolved
Double clamp engine exhaust ducts throughout (several missing one clamp).
Engineering › Diesel Engine (propulsion-reduction gear) › Bearing
Issued 24 May 2007
Resolved
Seal stuffing tube between engine space and lazarette.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 24 May 2007
Resolved
Provide cover for outlet in engine space where missing.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 24 May 2007
Resolved
Provide complete list of personnel in chemical testing pool specific to vessel.
Operations/Management › Vessel Safety Management › Master's Responsiblity/Authority
Issued 24 May 2007
Resolved
Master [name withheld] to provide proof of valid radio operator's permit. [name withheld] restricted from operating the radio until proof verified.
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 23 May 2007
Resolved
Provide lights and retro tape on 5 of the adult PFD's. Vessel limited to 43 persons until corrected.
Fire Fighting › Grease Extraction Hood › General
Issued 21 February 2007
Resolved
Install galley hood ducting IAW Sector SD CID Policy #20.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 15 May 2006
Resolved
Provide proof of current enrollment in approved chemical (drug & alchohol) testing program. Vessel restricted fm pax ops until corrected.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 15 May 2006
Resolved
Provide 01 more approved Type I adult PFD (lifejacket). Vsl restricted to no more than 47 pax until corrected.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 15 May 2006
Resolved
Properly label emergency escape hatch on top (galley deck) & ensure hatch kept clear.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 15 May 2006
Resolved
Install rail on top deck (crew only) no less than 36" in height.
Electrical › Electrical Distribution System (service) › Cable
Issued 15 May 2006
Resolved
Repair/replace cable (cover) on shore tie cable.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 2 June 2005
Resolved
Conduct satisfactory underway man overboard recovery drill in presence of Marine Inspector.
Operations/Management › Drills/Instruction › Fire
Issued 2 June 2005
Resolved
Conduct satisfactory fire drill in presence of Marine Inspector.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 2 June 2005
Resolved
Properly position anchor (all-around) light.
Deck/Cargo › Mooring/Anchoring › Winch
Issued 2 June 2005
Resolved
Prove proper operation of anchor windlass.
Communications › Alarms/Indicators › Bilge Alarm
Issued 2 June 2005
Resolved
Prove proper operation of bilge alarms.
Communications › Radio Communications › VHF Radiotelephone
Issued 2 June 2005
Resolved
Prove proper installation and operation of MF radio.
Communications › Radio Communications › EPIRB
Issued 2 June 2005
Resolved
Provide evidence of updated EPIRB registration information, including contact numbers.
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 2 June 2005
Resolved
Provide operable lights for nine (09) lifejackets.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 2 June 2005
Resolved
Provide one (01) more adult type I lifejacket.
Lifesaving › Lifebuoys › Stowage
Issued 2 June 2005
Resolved
Properly stow one (01) of the liferings.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 2 June 2005
Resolved
Provide updated CG Light List, or excerpts of areas vessel transits.
Navigation › Piloting/Steering › US Coast Pilot
Issued 2 June 2005
Resolved
Provide updated US Coast Pilot, or excerpts of areas to be transited.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 2 June 2005
Resolved
Provide updated tidal current tables for areas vessel transits.
Navigation › Piloting/Steering › Marine Charts
Issued 2 June 2005
Resolved
Provide updated charts for areas vessel transits.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 2 June 2005
Resolved
Replace missing/outdated items in first aid kit.
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 June 2005
Resolved
Properly wire all bridge equipment (breakers, wiring, & components).
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 June 2005
Resolved
Provide wiring diagram for all updated wiring in vessel.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 2 June 2005
Resolved
Provide proof of updated Certificate of Documentation.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 8 January 2003
Resolved
Replace worn strut bearings port shaft.
Construction/Loadline › Hull
Issued 8 January 2003
Resolved
Re-glass noted worn sections of hull exterior port and starboard sides.
Construction/Loadline › Hull
Issued 8 January 2003
Resolved
Repair rotted section of wormshoe.
Lifesaving › Emergency Outfit
Issued 15 February 2002
Resolved
Prior to carrying passengers, replace the expired hydrostatic release to the satisfaction of an attending marine inspector. LEGACY COMPONENT DESC: EPIRB hydrostatic release
Accommodation/Occupational Safety › Medical/First Aid
Issued 15 February 2002
Resolved
Prior to 15 March 2002, replace expired items in the first aid kits.
Lifesaving › Lifejacket/PFD (Type I)
Issued 15 February 2002
Resolved
Prior to 15 March 2002, provide placards for lifefackets stowed in bunk room, per 46 CFR 185.604, to the satisfaction of a marine inspector. LEGACY COMPONENT DESC: Marking
Construction/Loadline
Issued 30 March 1999
Resolved
Provide watertight cover for access hole to forepeak in way of the anchor chain.
Construction/Loadline
Issued 30 March 1999
Resolved
Submit proposal for sealing of the aft watertight bulkhead of the fish holdin way of existing watertight door and for installation of a watertight hatch to provide access to the lazerette from above. Work to be completed upon receipt of Coast Guard approval.
Lifesaving
Issued 25 March 1997
Resolved
Provide vessel to be available for underway trial.
Navigation
Issued 31 March 1993
Resolved
PROVIDE AN UP-TO-DATE COPY OF NAUTICAL CHART 18740 OR EQUIVALENT.
Lifesaving
Issued 31 March 1993
Resolved
SECURE THE SIX PERSON LIFE FLOAT IN AN "EASILY RELEASED" MANNER.
Electrical
Issued 30 March 1992
Resolved
PROVIDE COVER FOR STERN DECK LIGHT.
Documentation
Issued 30 March 1992
Resolved
PROVIDE CURRENT RADIO STATION LICENSE.
Electrical
Issued 30 March 1992
Resolved
REMOVE HARD-WIRED SHORE POWER CONNECTION TO DISTRIBUTION PANEL IN ENGINE_x001C_ ROOM AND PROVIDE SHORE POWER CONNECTION PLUG ON BOARD VESSEL.
Accommodation/Occupational Safety
Issued 30 March 1992
Resolved
SECURELY MOUNT LADDER FOR REFRIGERATOR HOLD AFT TO PREVENT MOVEMENT.
Construction/Loadline
Issued 19 April 1991
Resolved
CLEAN AND TREAT DRY ROT IN WOOD AROUND EXHAUST GOING THROUGH OVERHEAD IN ENGINE ROOM.
Lifesaving
Issued 11 April 1991
Resolved
REPLACE 6 PERSON LIFEFLOAT. VSL LIMITED TO 50 PERSONS ONBOARD UNTIL THIS ISCORRECTED.
Construction/Loadline
Issued 11 April 1991
Resolved
MAKE HATCH TO LAZARETTE FROM FISH HOLD WATERTIGHT. VSL LIMITED TO 49 PASSENGERS UNTIL THIS IS CORRECTED.
Navigation
Issued 11 April 1991
Resolved
PROVIDE COPIES OF TIDE AND CURRENT TABLES, LIGHT LIST AND COAST PILOT.
Electrical
Issued 11 April 1991
Resolved
REMOVE SJ WIRING IN ENGINEROOM AND REPLACE WITH UL APPROVED WIRING AND LABEL CIRCUIT BREAKERS IN ENGINEROOM PANEL.
Electrical
Issued 11 April 1991
Resolved
PROPERLY CONNECT WIRING FOR FRESH WATER PUMP IN ENGINEROOM.
Accommodation/Occupational Safety
Issued 11 April 1991
Resolved
PROPERLY REINSTALL MSD TANK FOR FEMALE HEAD.
Lifesaving
Issued 11 April 1991
Resolved
PROVIDE WATERTIGHT CONTAINER FOR FLARES.
Accommodation/Occupational Safety
Issued 11 April 1991
Resolved
POST INSTRUCTIONS FOR USE OF TOILETS.
Engineering
Issued 11 April 1991
Resolved
DOUBLE CLAMP GENERATOR COOLING HOSE.
Electrical
Issued 10 December 1990
Resolved
REPLACE THE GENERATOR OVERBOARD DISCHARGE PIPING WITH METALLIC PIPE.
Engineering
Issued 10 December 1990
Resolved
REPLACE THE BILGE PIPING WITH METALLIC PIPE.
Fire Fighting
Issued 10 December 1990
Resolved
REPLACE THE FIREMAIN PIPING WITH METALLIC PIPE.
Documentation
Issued 10 April 1990
Resolved
VESSEL IS LIMITED TO CARRY 81 PASSENGERS WHEN OPERATING ON COASTWISE SEASONAL ROUTE. NO PASSENGERS ARE ALLOWED ON THE UPPER DECK UNTIL DECK RAILS ARE INSTALLED IAW 46CFR177.35-1. AFTER DECK RAILS ARE INSTALLED IAW 46CFR177.35-1, THE VESSEL IS LIMITED TO 87 PASS. ON COASTWISE SEASONAL RT.
Lifesaving
Issued 26 March 1990
Resolved
LABEL LIFE JACKET STOWAGE IN HOUSE IAW 46 CFR 185.30-10.
Lifesaving
Issued 26 March 1990
Resolved
VESSEL IS LIMITED TO CARRY NOT MORE THAN 109 TOTAL PERSONS DUE TO PRIMARY LIFESAVING CAPABILITY.
Construction/Loadline
Issued 26 March 1990
Resolved
PROVIDE A CAPTIVE CHAIN OR SECURING DEVICE FOR ALL HATCHES ON MAIN DECK IAW46 CFR 171.124(B).
Electrical
Issued 26 March 1990
Resolved
REPAIR OR REPLACE BATTERY BOX IN ENGINE ROOM AND LINE WITH A MATERIAL RESISTANT TO THE BATTERY ELECTROLYTE.
Electrical
Issued 26 March 1990
Resolved
PROVIDE A COVER PLATE FOR ELECTRICIAL OUTLET ON AFT BULKHEAD, PORTSIDE, OF E/R. REMOVE ALLIGATOR CLIPS TO BATTERY TERMINALS AND FM RADIO ON BRIDGE.
Construction/Loadline
Issued 26 March 1990
Resolved
PROVIDE PLANS FOR CONVERSION OF COMPARTMENT FORWARD OF LAZARETTE TO A REFRIGERATED SPACE. PLANS MUST INCLUDE TYPE OF REFRIGERANT TO BE USED AND MUST BE APPROVED BY USCG PRIOR TO INSTALLATION.
Fire Fighting
Issued 26 March 1990
Resolved
SERVICE TWO PORTABLE BII FIRE EXTINGUISHERS AND PROVIDE PROOF OF HYDRO OR MANUFACTURE DATE.
Accommodation/Occupational Safety
Issued 6 April 1989
Resolved
CLEAN GALLEY GRILL VENT.
Electrical
Issued 6 April 1989
Resolved
PERMANENTLY INSTALL/HARDWIRE AFT DECK LIGHT AND STERNLIGHT.
Electrical
Issued 6 April 1989
Resolved
PROPERLY SPLICE WIRING WIRING THROUGHOUT THE VESSEL IAW 46 CFR 183.05-50(B)(PARTICULARLY AROUNG BRIDGE CONSOLE).
Electrical
Issued 6 April 1989
Resolved
PROPERLY DEAD-END WIRE ON FORWARD BULKHEAD OF ENGINEROOM IAW 46 CFR 183.05-50(B).
Engineering
Issued 6 April 1989
Resolved
REPAIR EXHAUST LEAK ON CENTER ENGINE.
Engineering
Issued 20 April 1988
Resolved
LABEL EMERGENCY FUEL SHUT-OFF VALVES AND REPLACE PLASTIC TIE-WRAPS ON REACHRODS WITH METALLIC MATERIAL.
Documentation
Issued 20 April 1988
Resolved
PROVIDE FCC RADIOTELEPHONY SAFETY CERTIFICATE.
Fire Fighting
Issued 26 April 1985
Resolved
REPAIR FIRE DETECTOR IN ENGINE ROOM.
Accommodation/Occupational Safety
Issued 26 April 1985
Resolved
LABEL: EMERGENCY ESCAPE HATCH, KEEP CLEAR; ON BOTH SIDES.
Electrical
Issued 26 April 1985
Resolved
PROVIDE COVER PLATES FOR OUTLETS AND JUNCTION BOXES, IN ENGINE ROOM AND PILOTHOUSE.
Casualty record · 1
1 August 2023Routine · role: Involved in a Marine Casualty · activity 7780587
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.