AZTEC

AZTEC is a 1976 passenger vessel (inspected). The Coast Guard has recorded 26 inspections since 2016, most recently in April 2026, along with 78 deficiencies — 1 with no resolution recorded —, 1 operational control, 1 with no removal date recorded and 1 casualty investigation in 2023.

Records from 2016 to 2026. Most recent: inspection, 2 April 2026.

Built
1976
Last inspected
2 April 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
1 with no removal date recorded

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 2 April 2026
…with no type recorded1
Operational controls 1 with no removal date recorded
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDJ2069
Flag
UNITED STATES
Maury page id
psix-48722

Documentation record

Registered dimensions (L × B × D)62.0 ft × 21.0 ft × 6.2 ft
Registered tonnagegross 66 / net 45
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSEAWAY BOAT CO. · LONG BEACH, CA, UNITED STATES · built 1976
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAN DIEGO, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 1 May 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it66 - Regulatory (Subpart C or D), Gross Ton
45 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 26

2 April 2026 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8341119
27 October 2025 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8259465
19 May 2025 COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8117813
6 March 2025 Drydock Exam · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8089593
14 May 2024 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7912766
26 March 2024 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7885453
2 August 2023 Administrative Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7758775
1 August 2023 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7780587
11 April 2023 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7667619
11 April 2023 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7674251
27 February 2023 Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7642914
8 August 2022 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7528294
23 May 2022 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7457425
6 October 2021 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7327843
1 June 2021 Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7211770
19 March 2021 Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7161602
22 January 2021 In-Service Inspection · Drydock Extension · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7131846
24 July 2020 Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7015359
27 April 2020 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6993371
8 October 2019 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6830814
31 July 2019 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6769312
31 January 2019 Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6618181
20 March 2018 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6375160
28 July 2017 Annual Survey · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6223839
7 June 2017 Internal Structural Exam · Deficiency Check · Drydock Exam · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6168418
19 September 2016 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6004176

Deficiency record · 78

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 April 2026 Resolved
Vessel must be provided with satisfactory arrangement for draining any watertight compartment. Vessel was unable to demonstrate operation of the fore peak bilge pump. Prove proper operation of the fore peak bilge pump.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2026
Resolved 22 April 2026
Resolution: Received video of fore peak bilge operating correctly. All SAT
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 April 2026 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Vessel's life ring buoy is worn. Replace life ring buoy.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2026
Resolved 22 April 2026
Resolution: Received photos of new lifering. All SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 April 2026 Resolved
Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts. Dead end wires found under helm in wheelhouse. Remove dead end wiring and update electrical plans.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2026
Resolved 29 April 2026
Resolution: Removed dead ended wires.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 April 2026 Resolved
MI found saltwater exhaust leak on Port MDE stainless steel fitting. Repair leak and notify local OCMI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2026
Resolved 29 April 2026
Resolution: New stainless steel bulkhead fittigns were made and installed.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 19 May 2025 Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. Vessel FFC Station license was expire. Provide valid FCC cert to local OCMI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 May 2025
Resolution: Vessel provided new FCC document. All SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 May 2025 Resolved
Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts. Dead end wires found in bilge under bunk room. Remove dead end wiring and update electrical plans.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 June 2025
Resolved 27 May 2025
Resolution: Wires were removed. All SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 May 2025 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. MI found open circuits slots in the galley breaker panel. Properly encase the breaker panel and notify local OCMI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2025
Resolved 27 May 2025
Resolution: Received photos of blanked breaker. All SAT.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 19 May 2025 Resolved
Vessel that have overnight accommodations must have interconnected fire detection system. Smoke detectors would operate but would not turn off until battery was removed. Fix interconnected smoke detection and notify local OCMI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 May 2025
Resolution: New smoke detectors were installed and tested by [name withheld].
07 - Fire Safety › N/A - No Subsystem › Fire patrol
Issued 14 May 2024 Resolved
Roving watch system was not operating as designed and operator could not figure out how to properly disarm the system to prevent it from repeatedly going off, which would most likely result in them securing the system instead of using it as required.
Action required: 17 - Rectify deficiencies prior to departure
Due 14 May 2024
Resolved 15 May 2024
Resolution: MI witnessed satisfactory operation.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 14 May 2024 Resolved
Stern light was found inoperable, restricted to daylight operations until stern light is repaired.
Action required: 705 - Other - as specified
Resolved 15 May 2024
Resolution: MI witnessed satisfactory operation of stern light.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 April 2023 Resolved
All electrical equipment shall be drip proof and protected. Need to remount face cover on distribution panel for pumps in the engine space to satisfaction of the USCG Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2023
Resolved 20 April 2023
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 11 April 2023 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Resolved 11 April 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 April 2023 Resolved
Ring buoys must have at least one floating waterlight with lanyard, unless only operating during daylight hours. Floating waterlight not operational during time of inspection. Corrected on the spot
Action required: 10 - Deficiency Rectified
Resolved 11 April 2023
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 11 April 2023 Resolved
EPIRB Tests must be conducted monthly and logged. Last EPIRB tested logged was 25NOV2022. Corrected on the spot
Action required: 10 - Deficiency Rectified
Resolved 11 April 2023
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 8 August 2022 Resolved
PROPERLY SEAL HOLE PENETRATION IN AFT E/R BULKHEAD
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 September 2022
Resolved 19 August 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 August 2022 Resolved
REPLACE 02 OOC LIFEJACKETS
Action required: 10 - Deficiency Rectified
Due 8 August 2022
Resolved 8 August 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 August 2022 Resolved
ENSURE ALL DEAD END WIRES ARE CAPPED, REMOVED OR A PROPER FIXTURE IS INSTALLED IN LAZ AND CREW BERTHS.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 September 2022
Resolved 19 August 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 June 2021 Resolved
Repair stbd propulsion engine wheelhouse shutdown.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 June 2021
Resolution: Solenoid replaced, shutdown tested.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 1 June 2021 Resolved
Properly install Fireboy automatic engine shutdown to ensure all engines shutdown regardless of where engine is started.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 June 2021
Resolution: Propulsion engine key must be in aux position in order to see alarms/guages on bridge and operate engines. Tested shutdowns in this position sat. POC to post this info on bridge.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 June 2021 Resolved
Complete DAPI audit.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2021
Resolved 4 June 2021
Resolution: Completed.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 1 June 2021 Resolved
Provide updated Light List and Coast Pilot.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2021
Resolved 4 June 2021
Resolution: New publications on board.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 1 June 2021 Resolved
Properly input GPS & MMSI into VHF-DSC capable radio.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2021
Resolved 4 June 2021
Resolution: Information verified on VHF-DSC.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 1 June 2021 Resolved
Install locking device to sewage overboard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2021
Resolved 4 June 2021
Resolution: Lock installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 June 2021 Resolved
Tighten port main engine sea-strainer piping.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2021
Resolved 4 June 2021
Resolution: Verified by attending MI.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 June 2021 Resolved
Clean grease from under/around oven and exhaust ducts.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2021
Resolved 4 June 2021
Resolution: Verified cleaned by attending MI.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 June 2021 Resolved
Replace lifering or repair grab line.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2021
Resolved 4 June 2021
Resolution: Life ring replaced/marked.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 1 June 2021 No resolution recorded
Onboard a passenger ship, as defined by the Convention for the Safety of Life at Sea, 1974, as amended (SOLAS) (incorporated by reference, see §15.103 of this part), on an international voyage, any person serving as master, chief mate, mate, chief engineer, engineer officer, or any person holding a license, MMD, or MMC and performing duties relating to safety, cargo handling, or care for passengers, must meet the appropriate requirements of Regulation V/2 of the STCW Convention (incorporated by reference, see §15.103 of this part). These individuals must hold documentary evidence to show they meet these requirements. Provide documentary evidence of required STCW training and valid medical certificates for masters and mates prior to operating in Mexican jurisdictional waters with more than 12 passengers.
Action required: 705 - Other - as specified
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 24 July 2020 Resolved
A renewal inspection for certification must be completed by the expiration date of the Certificate of Inspection. A written application (CG-3752) for renewal inspection must be submitted to the cognizant [name withheld] completed page 1 of form CG-3752. Complete CG-3752 prior to carrying passengers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 July 2020
Resolution: COI issued.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 24 July 2020 Resolved
Replace unapproved flexible non-metallic fuel hoses on generator with hose meeting SAE J-1942 standard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 August 2020
Resolved 29 October 2020
Resolution: Visually inspected corrected def.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 24 July 2020 Resolved
Install machinery guard at E/R ventilation fan.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 August 2020
Resolved 29 October 2020
Resolution: Visually inspected corrected def.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 24 July 2020 Resolved
Repair emergency exit light at forward exit from accom.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 August 2020
Resolved 29 October 2020
Resolution: Visually inspected corrected def.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 July 2020 Resolved
Replace heat exchanger end bells for exhaust piping cooling water on port & stbd MDE's.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 August 2020
Resolved 29 October 2020
Resolution: Visually inspected corrected def.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 October 2019 Resolved
Vessel has been identified as having A/C electrical modifications since initial certification. Sector San Diego has vessel's electrical plans on file but current installations do not match what is on file. Provide a one-line electrical drawing for all A/C switchboards and distribution panels. Include all circuit loads, conductor sizes, over current protection, and max panel ratings in amps.
Condition: Invalid
Action required: 705 - Other - as specified
Due 8 January 2020
Resolved 7 June 2021
Resolution: Final AC 1-line diagram verified.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 October 2019 Resolved
Install additional emergency/exit light at the emergency escape.
Condition: Invalid
Action required: 705 - Other - as specified
Due 8 January 2020
Resolved 27 July 2020
Resolution: Light installed but failed to work during COI. New def written.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 October 2019 Resolved
Install cover over junction box in galley stores locker.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 January 2020
Resolved 27 July 2020
Resolution: Cleared by attending MI.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 October 2019 Resolved
Install covers over 2 blower fans installed in the galley stores locker.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 January 2020
Resolved 27 July 2020
Resolution: Cleared by attending MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 August 2019 Resolved
Repair seeping fuel oil pumps on all three main engines.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 August 2019
Resolved 22 August 2019
Resolution: After a lot of excuses that the leaks couldn't be fixed in place, vessel rep hire a mechanic and made effective repairs.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 August 2019 Resolved
Make repairs to leak on jacket water expansion tank and seeping fuel line.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 August 2019
Resolved 21 August 2019
Resolution: Expansion tank was removed and re-welded. Fuel leaks was repaired.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 1 August 2019 Resolved
Replace destroyed charts with up to date versions.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 August 2019
Resolved 21 August 2019
Resolution: New charts were provided.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 August 2019 Resolved
Seal off chine bolt holes to prevent future rot.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 August 2019
Resolved 21 August 2019
Resolution: Chine bolt holes were filled with sealant.
Electrical › Electrical Distribution System (service) › Wiring
Issued 20 March 2018 Resolved
Remove extension cables for TVs, and install a permanent installation.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 April 2018
Resolved 21 March 2018
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 28 July 2017 Resolved
Provide smoke detectors for the berthing areas
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 August 2017
Resolved 1 November 2017
Resolution: Provided smoke detectors for the berthing areas.
Lifesaving › Lifebuoys › Stowage
Issued 28 July 2017 Resolved
Provide proper install of ring buoy.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 August 2017
Resolved 31 July 2017
Resolution: Provided proper install of ring buoy
Construction/Loadline › Structures › Transverse Bulkhead
Issued 28 July 2017 Resolved
Make lazerette bulkhead watertight.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 31 August 2017
Resolved 31 July 2017
Resolution: Made lazerette bulkhead watertight.
Engineering › Sea-water System (primary cooling) › Piping
Issued 28 July 2017 Resolved
Reconnect open ended piping in engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 August 2017
Resolved 31 July 2017
Resolution: Reconnected open ended piping in engine room.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 28 July 2017 Resolved
Provide latching doors to electrical boxes.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 August 2017
Resolved 1 November 2017
Resolution: Provided latching doors to electrical boxes.
Electrical › Electrical Distribution System (service) › Wiring
Issued 28 July 2017 Resolved
Trice up hanging wires in the engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 August 2017
Resolved 1 November 2017
Resolution: Triced up hanging wires in the engine room.
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 28 July 2017 Resolved
Port MDE leaks water, repair and demonstrate proper operation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 August 2017
Resolved 1 November 2017
Resolution: Port MDE leaks water, repair and demonstrated proper operation.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 28 July 2017 Resolved
Demonstrate proper shutdowns of fireboy.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 August 2017
Resolved 1 November 2017
Resolution: Demonstrated proper shutdowns of fireboy.
Fire Fighting › Fire Bucket › Quantity
Issued 28 July 2017 Resolved
Provide three fire buckets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 August 2017
Resolved 1 November 2017
Engineering › Diesel Engine (propulsion-reduction gear) › Pump, High Pressure (fuel injection)
Issued 21 September 2016 Resolved
Prove proper operation of propulsion system
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 September 2016
Lifesaving › Lifefloat › Float Free
Issued 19 September 2016 Resolved
Make starboard life floats float free
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 September 2016
Communications › Alarms/Indicators › High Water Alarm
Issued 19 September 2016 Resolved
Prove proper operation of high water alarm in all spaces
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 September 2016
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 19 September 2016 Resolved
Service two expired B-II fire extinguishers
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 September 2016
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 19 September 2016 Resolved
Service expired pre-engineered fixed fire extinguishing system
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 September 2016
Operations/Management › Drills/Instruction › Not Conducted
Issued 19 September 2016 Resolved
Conduct drills in presence of USCG
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 September 2016
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 19 September 2016 Resolved
Prove proper operation of Single Side Band Radio prior to operating beyond 20nm from shore.
Action required: 705 - Other - as specified
Resolved 21 September 2016
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 19 September 2016 Resolved
Prove proper operation of nav lights prior to operating at night
Action required: 705 - Other - as specified
Resolved 21 September 2016
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 19 September 2016 Resolved
Vessel reduce to 40 adult and 4 child until expired PFD lights are replaced.
Action required: 705 - Other - as specified
Resolved 21 September 2016
Electrical › Electric Generation Source (emergency) › Number of Sources
Issued 19 September 2016 Resolved
Prove proper operation of emergency lighting prior to conducting overnight trips.
Action required: 705 - Other - as specified
Resolved 21 September 2016
Navigation › Piloting/Steering › Marine Charts
Issued 19 September 2016 Resolved
Provide current charts
Action required: 705 - Other - as specified
Due 16 October 2016
Resolved 21 September 2016
Navigation › Piloting/Steering › US Coast Pilot
Issued 19 September 2016 Resolved
Provide current coast pilot
Action required: 705 - Other - as specified
Due 16 October 2016
Resolved 21 September 2016
Engineering › Bilge Water Management System › Hose
Issued 19 September 2016 Resolved
Provide hose clamp on fwd berthing bilge suction strainer.
Action required: 705 - Other - as specified
Due 16 October 2016
Resolved 21 September 2016
Electrical › Electrical Distribution System (service) › Wiring
Issued 19 September 2016 Resolved
Remove dead end wires under nav console
Action required: 705 - Other - as specified
Due 16 October 2016
Resolved 21 September 2016
Communications › Radio Communications › VHF Radiotelephone
Issued 19 September 2016 Resolved
Provide emergency broadcast placard IVO helm
Action required: 705 - Other - as specified
Due 16 October 2016
Resolved 21 September 2016
Documentation › Certificates/Documents › FCC SSL
Issued 19 September 2016 Resolved
Provide FCC Station license.
Action required: 705 - Other - as specified
Due 16 October 2016
Resolved 21 September 2016
Navigation › Piloting/Steering › Coast Guard Light List
Issued 19 September 2016 Resolved
Provide current light list
Action required: 705 - Other - as specified
Due 16 October 2016
Resolved 21 September 2016
Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 19 September 2016 Resolved
Provide current alcohol swabs.
Action required: 705 - Other - as specified
Due 16 October 2016
Resolved 21 September 2016
Fire Fighting › Means of Escape › Escape Route Signs
Issued 19 September 2016 Resolved
Label both side of emergency escape hatch.
Action required: 705 - Other - as specified
Due 16 October 2016
Resolved 21 September 2016
Electrical › Lighting (service) › Lighting Fixture
Issued 19 September 2016 Resolved
Provide cover for starboard E/R aft light fixture.
Action required: 705 - Other - as specified
Due 16 October 2016
Resolved 21 September 2016
Electrical › Electric Supply System (service) › Battery Installation
Issued 19 September 2016 Resolved
Properly stow excess batteries in E/R
Action required: 705 - Other - as specified
Due 16 October 2016
Resolved 21 September 2016
Electrical › Electric Generation Source (service) › Panelboard
Issued 19 September 2016 Resolved
Remove hazard from Stbd aft E/R panel
Action required: 705 - Other - as specified
Due 16 October 2016
Resolved 21 September 2016
Engineering › Fuel Oil Service System › Filter
Issued 19 September 2016 Resolved
Repair leak on port sediment fuel filter.
Action required: 705 - Other - as specified
Due 16 October 2016
Resolved 21 September 2016
Electrical › Electrical Distribution System (service) › Wiring
Issued 19 September 2016 Resolved
Remove dead end wires in forepeak
Action required: 705 - Other - as specified
Due 16 October 2016
Resolved 21 September 2016
Deck/Cargo › Cargo Stowage › General
Issued 19 September 2016 Resolved
Properly stow helium bottle IAW 49CFR176.200(c)
Action required: 705 - Other - as specified
Due 16 October 2016
Resolved 21 September 2016
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 19 September 2016 Resolved
Evaluate plug for powering beer box
Action required: 705 - Other - as specified
Due 16 October 2016
Resolved 21 September 2016
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 19 September 2016 Resolved
Replace outlet cover IVO beer box
Action required: 705 - Other - as specified
Due 16 October 2016
Resolved 21 September 2016
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 19 September 2016 Resolved
Provide proper rescue platform
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 September 2016

Casualty record · 1

1 August 2023Routine · role: Involved in a Marine Casualty · activity 7780587
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.