VICTORIA STAR2 is a 1976 passenger vessel (inspected). The Coast Guard has recorded 104 inspections since 1981, most recently in March 2026, along with 119 deficiencies and 1 casualty investigation in 2010.

Records from 1981 to 2026. Most recent: inspection, 25 March 2026.

Built
1976
Last inspected
25 March 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCW4552
Flag
UNITED STATES
367091440 (licence lapsed)
Maury page id
psix-48723

Inspections, by type

…with no type recorded14
Years with a record 42 calendar years (1981–2026)
The 104 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)96.4 ft × 23.5 ft × 7.0 ft
Registered tonnagegross 99 / net 67
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDYNAMIC SHIPBUILDERS INC. · JEAN LAFITTE, LA, UNITED STATES · built 1976
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portBELLINGHAM, WA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 30 March 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it99 - Regulatory (Subpart C or D), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WCW4552MMSI 367091440 · expired · voluntarily equipped · granted 3 February 2016, cancelled 20 June 2026 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 104

25 March 2026 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8299761
2 April 2025 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8103660
19 February 2025 Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8081756
20 March 2024 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7888384
17 May 2023 In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7690000
12 April 2023 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7667610
24 January 2023 Internal Structural Exam · Drydock Exam · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7626628
30 March 2022 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7422863
5 November 2021 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7346235
31 March 2021 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7150520
10 March 2021 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7155057
17 June 2020 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6980535
11 March 2020 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6923446
23 April 2019 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6668529
3 April 2019 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6655456
27 April 2018 Security Plan Review - VSP · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6397891
28 March 2018 Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6380900
11 April 2017 DAPI Audit · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6123350
21 March 2017 Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6108375
23 September 2016 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6007623
22 March 2016 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5840729
6 October 2015 COI Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5735795
7 October 2014 Administrative Inspection · COI Inspection · MTSA/ISPS Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5000354
28 May 2012 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4326092
30 December 2011 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4216133
6 December 2010 Internal Structural Exam · Examination of Repairs · Damage Survey · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3913991
23 November 2010 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3905947
12 October 2010 COI Inspection · MTSA/ISPS Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3869428
14 April 2009 Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3453009
6 October 2008 MTSA/ISPS Verification · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3339826
11 July 2008 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3275746
22 April 2008 Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3190711
11 January 2008 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3128728
14 September 2007 COI Inspection · Hull Examination · Internal Structural Exam · MTSA/ISPS Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3057609
12 June 2007 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2959260
5 February 2007 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2867494
3 October 2006 Drydock Extension · COI Inspection · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2797254
5 October 2005 Hull Examination · Internal Structural Exam · MTSA/ISPS Verification · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2508490
7 October 2004 COI Inspection · MTSA/ISPS Verification · Internal Structural Exam · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2214961
2 June 2004 MTSA/ISPS Verification
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2086067
22 December 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1979559
14 October 2003 Hull Examination · COI Inspection · Internal Structural Exam
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1929298
21 November 2002 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1702012
30 October 2002 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1698649
24 April 2002 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1634395
15 April 2002 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1601935
6 March 2002 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1490513
18 April 2001 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 212864
16 April 2001 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1441822
22 March 2001 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1450587
4 April 2000 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1465542
28 March 2000 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1420286
15 March 1999 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1397124
9 March 1999 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1381497
24 September 1998 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 799525
11 June 1998 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1418361
13 April 1998 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 788676
9 April 1998 Re-Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1414958
6 April 1998 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 788539
23 September 1997 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 187370
17 April 1997 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1465305
9 April 1997 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1392653
26 April 1996 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1355760
7 February 1996 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1419571
12 December 1995 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1431583
10 September 1995 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1189306
31 January 1994 Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 852296
28 October 1993 Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1444760
10 May 1993 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 673512
4 May 1993 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 155956
12 April 1993 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1147194
2 April 1993 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 835860
23 February 1993 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 691734
18 March 1992 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1268801
2 October 1991 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 829952
2 October 1991 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1253906
27 August 1991 Drydock Extension
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 935524
30 May 1991 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 908482
21 May 1991 Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 916942
23 April 1991 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1244143
12 April 1991 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1213970
12 April 1991 Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1213971
16 October 1990 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1233309
14 September 1990 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 916152
5 September 1990 Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 923196
3 August 1990 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1239227
8 June 1990 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1226541
7 June 1990 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1223124
1 June 1990 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 911873
11 April 1990 Deficiency Check · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1214294
12 February 1990 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 917980
12 April 1989 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1035498
7 April 1989 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1348017
15 March 1989 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1195349
4 October 1988 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1197539
15 April 1988 Hull Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1034236
4 June 1987 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1027692
21 May 1987 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1026755
12 January 1987 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1312986
15 October 1986 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1317284
22 May 1986 Credit Drydock · Initial Certification
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1293188
9 September 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 970258
16 May 1981 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 966702
15 May 1981 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1273142

Deficiency record · 119

07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 March 2026 Resolved
Fire hose shall be 1 1/2 inches in diameter and 50 feet in length. If 1 inch diameter fire hose is used, each length of hose must [...] be lined commercial fire hose that conforms to Underwriters' Laboratories, Inc., Standard 19 or Federal Specification ZZ-H-451E. A hose that bears the Label of Underwriters' Laboratories, Inc., as lined fire hose is accepted as conforming to the requirement. The two hoses installed onboard the vessel were not marked UL19. O/o is to provide evidence of hoses meeting the standard or replace hoses to ones meeting the requirements stated above. 46 CFR 181.15-10(c) 46 CFR 181.15-10(d)(1)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2026
Resolved 31 March 2026
Resolution: O/o replaced hose with UL 19, 1.5" diameter hose.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 March 2026 Resolved
Have a nozzle that has a 1/2 inch solid stream orifice or a combination nozzle approved by the Commandant in accordance with § 162.027-6 of this Chapter. The nozzle must be bronze or another material that has strength and corrosion resistance properties equal to those of bronze. MI observed both hoses equipped with plastic nozzles, one of which was degraded. O/o is to replace both nozzles to meet the standard. 46 CFR 181.15-10(d)(2)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2026
Resolved 31 March 2026
Resolution: O/o replaced plastic nozzles with bronze material nozzles.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 March 2026 Resolved
Each lifeline on a ring life buoy must [...] be bouyant; be of at least 18.3 meters (60 feet) in length; be non-kinking; have a diameter of at least 7.9 millimeters (5/16 inch); have a breaking strength of at least 5 kilonewtons (1,124 pounds); and he of a dark color if synthetic, or of a type certified to be resistant to deterioration from ultraviolet light. 46 CFR 180.70(c)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2026
Resolved 31 March 2026
Resolution: O/o replaced life buoy life line with 46 CFR 180.70(c) compliant life line.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 March 2026 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. MI observed the forward starboard ring life buoy to be in unserviceable condition. O/o is to replace ring life buoy. 46 CFR 176.808(b)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2026
Resolved 31 March 2026
Resolution: O/o replaced unserviceable ring life buoy with new life buoy.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 March 2026 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. MI observed numerous [name withheld], enclosed cell type life jackets to be in unserviceable condition. O/o is to repair or replace life jackets. 46 CFR 176.808(b)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2026
Resolved 31 March 2026
Resolution: O/o replaced unserviceable lifejackets with serviceable life jackets.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 25 March 2026 Resolved
Combustibles and other foreign materials are not allowed within ventilation ducts. Dryer vent duct was found to have heavy build up. Duct to be cleaned or replaced. 46 CFR 177.600(e)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2026
Resolved 31 March 2026
Resolution: O/o replaced dryer vent duct.
01 - Certificates & Documentation › 011 - Ships Certificates › Passenger Ship Safety (including exemption)
Issued 31 March 2021 Resolved
Vessel cannot operate on an international voyage until proper PSSC and SOLAS Exemption Certificates have been issued. 46 CFR 2.01-25
Condition: Placed in Improper Service
Action required: 702 - Prior to embarking on international voyage
Due 1 August 2021
Resolved 16 April 2021
Resolution: Vessel rep has decided to skip out on getting an international route on the COI.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 11 April 2017 Resolved
Replace HRU on EPIRB.
Action required: 705 - Other - as specified
Due 14 April 2017
Resolved 14 April 2017
Resolution: Provided new EPIRB.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 11 April 2017 Resolved
Replace battery in EPIRB.
Action required: 705 - Other - as specified
Due 14 April 2017
Resolved 14 April 2017
Resolution: Replaced with new EPIRB.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 11 April 2017 Resolved
Provide non-expired eye wash.
Action required: 705 - Other - as specified
Due 11 May 2017
Resolved 14 April 2017
Resolution: Provided proof of non-expired eye wash.
Electrical › Electrical Distribution System (service) › Wiring
Issued 19 November 2015 Resolved
Protect passengers, crew, other persons and the vessel from electrical hazards. Receive approval from MSC for current one line electrical diagram of VICTORIA STAR2.
Action required: 705 - Other - as specified
Due 19 December 2015
Resolved 9 June 2016
Resolution: Received email from MSC with letter approving line diagram.
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 October 2015 Resolved
Protect passengers, crew, other persons and the vessel from electrical hazards. Provide an up to date electrical line diagram of the vessel. 46 CFR 183.200(b)
Action required: 705 - Other - as specified
Due 6 November 2015
Resolved 2 November 2015
Resolution: Email sent with updated wiring diagram.
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 October 2015 Resolved
Protect passengers, crew, other persons and the vessel from electrical hazards. Replace temporary installation of oven wires, located in forward galley, with more permanent installation. 46 CFR 183.200(b)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 November 2015
Resolved 2 November 2015
Resolution: Email sent with picture of satisfactory installation of oven wiring.
Operations/Management › Vessel Safety Management › Plans for Shipboard Operations
Issued 6 October 2015 Resolved
The station bill must be posted at the operating station and in a conspicuous location in each crew accomodation space. Provide sation bill in accordance with 46 CFR 185.514, at the operating station. 46 CFR 185.514(c)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 November 2015
Resolved 2 November 2015
Resolution: Email sent with attached picure of station bill.
Operations/Management › Vessel Safety Management › Plans for Shipboard Operations
Issued 6 October 2015 Resolved
Have mounted at the operating station, emergency instructions. Provide emergency instructions at the operating station. 46 CFR 185.510(a)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 October 2015
Resolved 12 October 2015
Resolution: Picture of emergency instructions posted sent.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 6 October 2015 Resolved
An adult life jacket must be provided for each person carried on board a vessel. Repair clips on life jackets in service. 46 CFR 180.71(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 October 2015
Resolved 12 October 2015
Resolution: Pictures of lfiejackets sent.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 6 October 2015 Resolved
Each life jacket must be marked in clearly legible block capital letters with the vessel's name. Remove previous vessel names from life jacket. 46 CFR 185.604(b)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 October 2015
Resolved 12 October 2015
Resolution: Picture sent of properly marked adult life jacket.
Engineering › Steering Gear System › Fastener
Issued 7 October 2014 Resolved
Submit repair proposal and repair steering linkages to the satisfaction of the attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 November 2014
Resolution: Installed bushings to steering linkages. Operational test sat. All sat.
Fire Fighting › Fire Main › Condition
Issued 7 October 2014 Resolved
Submit repair proposal and repair firemain to the satisfaction of the attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 November 2014
Resolution: Replaced link of pipe and fabricated and installed two through bulk head fixtures in fuel tank space. Operational test sat. All sat.
Construction/Loadline › Hull › Side Shell
Issued 6 December 2010 Resolved
conduct satisfactory repair of affected areas of Bow and transom of the vessel in accordance with approved repair proposal to the satisfaction of attending USCG Inspector and prior to carrying passengers.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 January 2011
Resolved 30 December 2010
Resolution: Witnessed satisfactory NDT of all repairs made. all sat.
Engineering › Diesel Engine (propulsion-direct drive) › Valve
Issued 6 December 2010 Resolved
Replace/renew in kind STBD main engine 3" seachest valve to the satisfaction of attending USCG Inspector NLT 01JAN11
Action required: 705 - Other - as specified
Due 1 January 2011
Resolved 30 December 2010
Resolution: Replace in kind by new 3" valve, all sat.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 12 October 2010 Resolved
Replace port engine machinery guard with marine approved guard.
Due 12 November 2010
Resolved 30 November 2010
Resolution: Guard provided.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 12 October 2010 Resolved
Properly place cover over starboard ship's service generator machinery guard.
Due 12 November 2010
Resolved 30 November 2010
Resolution: Guard provided.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 12 October 2010 Resolved
Permanently affix ammeter gauge on port ship's service generator main switchboard.
Due 12 November 2010
Resolved 30 November 2010
Resolution: Ammeter gauge has been properly affixed.
Engineering › Diesel Engine (propulsion-direct drive) › Governor
Issued 12 October 2010 Resolved
Make proper permanent repair on port engine governor spring loader fuel shutdown arm.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 November 2010
Resolution: Jury-rigged connection removed and replaced with spring.
Fire Fighting › Fire Pumps › Suction Valve
Issued 6 October 2008 Resolved
Provide valve handle for back-up stbd main engine fire pump suction. Wrench with lanyard attached to valve has been temporarily installed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 October 2008
Resolved 9 October 2008
Navigation › Piloting/Steering › Marine Charts
Issued 6 October 2008 Resolved
Provide navigation charts for Bremerton to Seattle route while operating under the Washington State Ferries.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 October 2008
Resolved 6 October 2008
Electrical › Lighting (service) › Lighting Fixture
Issued 14 September 2007 Resolved
Put protective covers over all lighting.
Due 17 November 2007
Resolved 11 January 2008
Resolution: Put protective covers on lighting.
Engineering › Bilge Water Management System › Not Operational
Issued 14 September 2007 Resolved
Make operable forward bilge alarm
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 October 2007
Resolution: Made bilge alarm operable
Lifesaving › Lifebuoys › Immediately Available
Issued 14 September 2007 Resolved
Forward lifering buoy is not immediately available due to the placement of the light.
Due 17 November 2007
Resolved 17 October 2007
Resolution: Moved the light so that the lifering buoy was able to be removed from it''s holder.
Electrical › Electric Supply System (service) › Cable
Issued 14 September 2007 Resolved
Remove wire that is not being used in the galley storage area.
Due 17 November 2007
Resolved 17 October 2007
Resolution: Wire was removed from galley storage area
Engineering › Diesel Engine (propulsion-direct drive) › Connecting Rod
Issued 14 September 2007 Resolved
Re-wire the engine shut down on the port side engine.
Due 17 November 2007
Resolved 17 October 2007
Resolution: Re-wired the engine shut down
Electrical › Electric Generation Source (service) › Metallic Enclosure/Frame
Issued 14 September 2007 Resolved
Cover exposed outlet in the galley
Due 17 November 2007
Resolved 17 October 2007
Resolution: Put a cover on the outlet
Engineering › Sea-water System (primary cooling) › Piping
Issued 14 September 2007 Resolved
Tighten the raw water hoses on the port and starboard overboard discharge pipes.
Due 17 November 2007
Resolved 23 October 2007
Resolution: Re-inspected raw water hoses on port and starboard overboard discharge pipes to ensure properly sealed. Ran engines for approx 15 minutes and verified to leaking on or around hoses.
Construction/Loadline › Hull › Hull Plating
Issued 14 September 2007 Resolved
Power wash surface corrosion at the bottom of the port side of the engine room
Due 17 November 2007
Resolved 11 January 2008
Resolution: Power washed the surface corrosion in the engine room.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 3 October 2006 Resolved
Small bolt hole found on top of collision bulkhead.
Due 10 October 2006
Resolved 3 October 2006
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 5 November 2003 Resolved
Six of the lifejacket lights were not operational and needed to be replaced.
Due 12 November 2003
Resolved 6 November 2003
Fire Fighting › Fire Hoses › Condition
Issued 5 November 2003 Resolved
The port fire hose had a pinhole leak and needed to be replaced.
Due 12 November 2003
Resolved 6 November 2003
Fire Fighting › Fire Pumps
Issued 20 October 2003 Resolved
The vessel's main fire pump was being worked on and was not onboard vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 November 2003
Documentation › Certificates/Documents
Issued 20 October 2003 Resolved
The vessel rep could not produce the certificate of documentation. LEGACY COMPONENT DESC: Certificate of Documentation (CG-1270)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 November 2003
Operations/Management › Equipment Service/Testing › EPIRB
Issued 20 October 2003 Resolved
The hydrostatic release for the EPIRB had expired and needed to be replaced.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 November 2003
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 20 October 2003 Resolved
The hydrostatic release for one of the IBA was not attached to the vessel. Two of the IBA's did not have a weak link attached to the ship.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 November 2003
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 20 October 2003 Resolved
19 replacement adult lifejackets were not marked with the vessels name and needed waterlights.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 November 2003
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 20 October 2003 Resolved
The storage compartments for the lifejackets were not marked.
Due 5 November 2003
Resolved 5 November 2003
Lifesaving › Lifebuoys
Issued 20 October 2003 Resolved
The reflective tape on the starboard lifebuoy needed to be replaced.
Due 5 November 2003
Resolved 5 November 2003
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 20 October 2003 Resolved
The waterlight for the port lifebuoy was not properly attached.
Due 5 November 2003
Resolved 5 November 2003
Fire Fighting › Fire Pumps
Issued 15 April 2002 Resolved
Prove proper operation of electric fire pump prior to carriage of passengers.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 April 2002
Resolved 24 April 2002
Resolution: witnessed satisfactory opperation of fire pump.
Fire Fighting › Fire Main
Issued 15 April 2002 Resolved
Install hard piping in lieu of hose section connecting to electric fire pump prior to carriage of passengers. LEGACY COMPONENT DESC: Material
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 April 2002
Resolved 24 April 2002
Resolution: examined piping installed, all sat.
Documentation
Issued 11 June 1998 Resolved
DRILLS ARE NOT CONSISTENTLY BEING DOCUMENTED IN THE BRIDGE OFFICIAL LOGBOOKAS PER THEIR SMS (ISM CODE 8.2).
Condition: Unknown
Due 11 June 1998
Resolved 11 June 1998
Lifesaving
Issued 9 April 1998 Resolved
PROVIDE PFD LIGHTS FOR 24 VESSEL PFD'S AND RELABEL THE SAME PFDS WITH PROPER VESSEL NAME TO BE COMPLETED PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 13 April 1998
Resolved 13 April 1998
Lifesaving
Issued 9 April 1998 Resolved
PROVIDE ADMINISTRATION APPROVED VESSEL SAR PLAN TO MEET SOLAS REGULATIONS.
Condition: Unknown
Due 9 April 1998
Resolved 9 April 1998
Construction/Loadline
Issued 26 April 1996 Resolved
WTD LEADING TO AFT STEERING FROM THE ENGINEROOM NEEDS TO BE SEALED CLOSED. PERMINANTLY WELDED CLOSED TO ENSURE SUB-DIVISION.
Condition: Unknown
Due 26 April 1996
Resolved 26 April 1996
Engineering
Issued 2 April 1993 Resolved
REPAIR STBD MAIN ENGINE REMOTE SHUT-OFF.
Condition: Unknown
Due 2 April 1993
Resolved 2 April 1993
Lifesaving
Issued 2 April 1993 Resolved
LABEL THE 15 MN LIFE FLOAT, INSTALL SEA PAINTER AND WATER LIGHT.
Condition: Unknown
Due 2 April 1993
Resolved 2 April 1993
Engineering
Issued 2 April 1993 Resolved
MAKE PORT ENGINE OPERABLE. ENGINE DOWN FOR MAINTENANCE DURING INSPECTION.
Condition: Unknown
Due 2 April 1993
Resolved 2 April 1993
Construction/Loadline
Issued 2 April 1993 Resolved
REPAIR FOREPEAK BILGE SUCTION VALVE REACH ROD.
Condition: Unknown
Due 2 April 1993
Resolved 2 April 1993
Electrical
Issued 12 April 1991 Resolved
REPAIR INOPERABLE AMP METER FOR THE SHIP SERVICE DIESEL GENERATOR. _x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 April 1991
Resolved 12 April 1991
Electrical
Issued 12 April 1991 Resolved
REPAIR INOPERABLE ELECTRIC ANCHOR WINCH. _x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 April 1991
Resolved 12 April 1991
Electrical
Issued 12 April 1991 Resolved
REPAIR INOPERABLE ELECTRIC BLOWER IN THE ENGINEROOM. _x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 April 1991
Resolved 12 April 1991
Electrical
Issued 12 April 1991 Resolved
REPAIR BROKEN LATCH FOR THE COVER OF THE FORWARD 110V DISTRIBUTION PANEL.
Condition: Unknown
Due 12 April 1991
Resolved 12 April 1991
Fire Fighting
Issued 12 April 1991 Resolved
REPAIR ELECTRIC MAIN FIRE PUMP TO BRING THE DISCHARGE PRESSURE TO NOT LESS_x001C_THAN 60 PSI PRIOR TO CARRYING PASSENGERS ON BOARD. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 April 1991
Resolved 12 April 1991
Accommodation/Occupational Safety
Issued 3 August 1990 Resolved
PROPERLY INSTALL THE ESCAPE LADDER IN THE GALLEY ROOM.
Condition: Unknown
Due 3 August 1990
Resolved 3 August 1990
Documentation
Issued 3 August 1990 Resolved
PROVIDE A VALID CERTIFICATE OF DOCUMENTATION ON BOARD THAT REFLECTS THE CHANGE OF VESSEL'S CURRENT NAME "RENNA G".
Condition: Unknown
Due 3 August 1990
Resolved 3 August 1990
Construction/Loadline
Issued 3 August 1990 Resolved
PROVE THE PROPER OPERATION OF THE ALARMS ON ALL WATERTIGHT DOORS LOCATED BELOW THE MAIN DECK. UNTIL THE ALARMS ARE PROPERLY CORRECTED A ROVING WATCHDESIGNATED BY THE MASTER SHALL BE MAINTAINED ALL THE TIME THE VESSEL IS UNDERWAY AND WITH PASSENGERS TO MONITOR THESE DOORS CLOSED ALL THE TIME.
Condition: Unknown
Due 3 August 1990
Resolved 3 August 1990
Electrical
Issued 3 August 1990 Resolved
PROVIDE SPECIFICATIONS ON THE SHORE-TIE CABLE USED.
Condition: Unknown
Due 3 August 1990
Resolved 3 August 1990
Unknown
Issued 3 August 1990 Resolved
PROVE THE PROPER INSTALLATION AND OPERATION OF THE PORT AND STARBOARD STABILIZER FINS IN THE PRESENCE OF COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 3 August 1990
Resolved 3 August 1990
Engineering
Issued 3 August 1990 Resolved
PROVIDE FLAME SHIELD COVERS TO THE PORT AND STARBOARD REMOTE CONTROL EMERGENCY FUEL OIL SHUT-OFF VALVES.
Condition: Unknown
Due 3 August 1990
Resolved 3 August 1990
Lifesaving
Issued 11 April 1990 Resolved
PROVIDE RETRO-REFLECTIVE TAPE FOR ONE LIFEFLOAT 2X CIRCUMFERENCE X EACH SIDE.
Condition: Unknown
Due 11 April 1990
Resolved 11 April 1990
Lifesaving
Issued 11 April 1990 Resolved
STENCIL VSL NAME ON ALL LIFE SAVING APPLIANCES; LIFE PRESERVERS,RING BUOYS,AND LIFE FLOATS.
Condition: Unknown
Due 11 April 1990
Resolved 11 April 1990
Documentation
Issued 11 April 1990 Resolved
PROVIDE VSL'S STABILITY LETTER ISSUED BY CGD8 (MMT) DTD 20MAY86 AND RETAIN ON BOARD.
Condition: Unknown
Due 11 April 1990
Resolved 11 April 1990
Navigation
Issued 11 April 1990 Resolved
PROVIDE CURRENT COPY OF LOCAL NTOICE TO MARINERS UPDATING CHARTS, ETC.
Condition: Unknown
Due 11 April 1990
Resolved 11 April 1990
Engineering
Issued 11 April 1990 Resolved
REMOVE OILY WATER FROM BILGES.
Condition: Unknown
Due 11 April 1990
Resolved 11 April 1990
Construction/Loadline
Issued 11 April 1990 Resolved
REPAIR WATERTIGHT HATCH FOR LAZARETTE AND EMERGENCY ESCAPE HATCH FROM ENGINE ROOM PORT SIDE.
Condition: Unknown
Due 11 April 1990
Resolved 11 April 1990
Electrical
Issued 11 April 1990 Resolved
PROVIDE LAGGING FOR STBD GENERATOR EXHAUST EXPANSION SECTION.
Condition: Unknown
Due 11 April 1990
Resolved 11 April 1990
Electrical
Issued 11 April 1990 Resolved
PROVE OPERATION OF VSL'S GROUND FAULT DETECTION SYSTEM.
Condition: Unknown
Due 11 April 1990
Resolved 11 April 1990
Construction/Loadline
Issued 11 April 1990 Resolved
PROVIDE CAPTIVE CHAIN FOR EMERGENCY HATCH, EXITING FROM GALLEY AREA.
Condition: Unknown
Due 11 April 1990
Resolved 11 April 1990
Fire Fighting
Issued 11 April 1990 Resolved
STENCIL VSL NAME ON FIRE AXE AND RELOCATE TO VICINITY OF PILOT HOUSE.
Condition: Unknown
Due 11 April 1990
Resolved 11 April 1990
Fire Fighting
Issued 11 April 1990 Resolved
RENEW CO2 CARTRIDGE FOR DRY CHEMICAL BII EXTINGUISHER 12 YR LIFE EXPIRED.
Condition: Unknown
Due 11 April 1990
Resolved 11 April 1990
Engineering
Issued 11 April 1990 Resolved
PROVIDE LAGGING FOR THREE (3) MAIN ENGINE EXHAUST SYSTEM.
Condition: Unknown
Due 11 April 1990
Resolved 11 April 1990
Engineering
Issued 11 April 1990 Resolved
PROVIDE DRIP PANS FOR MAIN ENGINE FUEL FILTERS (3). CORRECTED 16APR90.
Condition: Unknown
Due 11 April 1990
Resolved 11 April 1990
Electrical
Issued 11 April 1990 Resolved
PROVIDE LIGHT FIXTURE GLOBES FOR LIGHTS IN ENGINE ROOM AND LAZARETTE, A TOTAL OF 4.
Condition: Unknown
Due 11 April 1990
Resolved 11 April 1990
Electrical
Issued 11 April 1990 Resolved
PROPERLY INSTALL LIGHT OR INSTALL LIGHT OR INSTALL JUNCTION BOX FOR DISBALED FIXTURE.
Condition: Unknown
Due 11 April 1990
Resolved 11 April 1990
Navigation
Issued 11 April 1990 Resolved
PROPERLY ANCHOR HYDRAULIC LINE FROM PUMP ON STBD GENERATOR. CORRECTED 16APR90.
Condition: Unknown
Due 11 April 1990
Resolved 11 April 1990
Construction/Loadline
Issued 11 April 1990 Resolved
PROVIDE WATERTIGHT STUFFING TUBE FOR CABLE TRANSITTING THRU COLLSION BULKHEAD. PLUG 4 HOLES SAME AREA.
Condition: Unknown
Due 11 April 1990
Resolved 11 April 1990
Documentation
Issued 11 April 1990 Resolved
PROVIDE RADIO STATION LICENSE (FCC) FOR WHALE WATCHER II.
Condition: Unknown
Due 11 April 1990
Resolved 11 April 1990
Engineering
Issued 11 April 1990 Resolved
STENCIL/IDENTIFY EMERGENCY FUEL SHUT OFF VALVES LOCATED IN PASSAGEWAY SEATING AREA MAIN DECK.
Condition: Unknown
Due 11 April 1990
Resolved 11 April 1990
Accommodation/Occupational Safety
Issued 11 April 1990 Resolved
REMOVE KEROSENE HEATER FROM VSL.
Condition: Unknown
Due 11 April 1990
Resolved 11 April 1990
Construction/Loadline
Issued 12 February 1990 Resolved
VEE AND WELD CRACK IN NO.3 SIDE SHELL LONGITUDINAL FROM BOTTOM, STBD SIDE IN WAY OF ENGINE ROOM.
Condition: Unknown
Due 12 February 1990
Resolved 12 February 1990
Construction/Loadline
Issued 12 February 1990 Resolved
REPLACE CUT OUT SECTION OF FRAME IN WAY OF VENTILATION FAN IN AFT STEERING SPACE STBD SIDE.
Condition: Unknown
Due 12 February 1990
Resolved 12 February 1990
Construction/Loadline
Issued 4 October 1988 Resolved
INSTALL INDICATORS SHOWING VSL OPERATOR WHEN WATERTIGHT DOORS ARE OPEN. EACH DOOR IN BELOW DECK WATERTIGHT BULKHEAD MUST BE FITTED WITH THE NECESSARY SWITCH AND WIRED TO AN INDICATOR PANEL ON NAVIGATION BRIDGE.
Condition: Unknown
Due 4 October 1988
Resolved 4 October 1988
Construction/Loadline
Issued 4 October 1988 Resolved
EITHER PROVIDE QUICK ACTING MECHANISMS FOR WATERTIGHT DOORS IN WATERTIGHT BULKHEADS, OR WELD DOORS CLOSED.
Condition: Unknown
Due 4 October 1988
Resolved 4 October 1988
Electrical
Issued 15 April 1988 Resolved
COVER THE HOLE IN THE AFT ACCOMMODATION'S CIRCUIT BREAKER.
Condition: Unknown
Due 15 April 1988
Resolved 15 April 1988
Engineering
Issued 15 April 1988 Resolved
REMOVE THE OIL FROM THE BILGES. THIS MUST BE COMPLETED PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 15 April 1988
Resolved 15 April 1988
Electrical
Issued 15 April 1988 Resolved
PROVIDE GUARDS FOR THE EXPOSED ROTATING SHAFTS ON THE FORWARD SIDE OF BOTH GENERATORS.
Condition: Unknown
Due 15 April 1988
Resolved 15 April 1988
Construction/Loadline
Issued 15 April 1988 Resolved
VEE AND WELD STBD SIDE LONG WELDS ON #3 & 4 LONGS 6' AFT OF FWD ENGINEROOM BULKHEAD.
Condition: Unknown
Due 15 April 1988
Resolved 15 April 1988
Navigation
Issued 15 April 1988 Resolved
REPOSITION MASTHEAD LIGHT FORWARD OF SIDELIGHTS IN ACCORDANCE WITH 1972 COLREGS ANNEX I, PARAGRAPH 3 (B).
Condition: Unknown
Due 15 April 1988
Resolved 15 April 1988
Documentation
Issued 15 April 1988 Resolved
OBTAIN A SAFETY RADIOTELEPHONE CERTIFICATE AND POST IN THE PILOT HOUSE.
Condition: Unknown
Due 15 April 1988
Resolved 15 April 1988
Construction/Loadline
Issued 15 April 1988 Resolved
SEAL ALL THE UNDERDECK TRANSVERSE BULKHEAD PENETRATIONS.
Condition: Unknown
Due 15 April 1988
Resolved 15 April 1988
Electrical
Issued 15 April 1988 Resolved
CLEAN THE OIL SOAKED ENGINEROOM VENT MOTORS. THIS MUST BE COMPLETED PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 15 April 1988
Resolved 15 April 1988
Electrical
Issued 15 April 1988 Resolved
PROVIDE COVERS FOR THE ACCOMMODATION LIGHTS.
Condition: Unknown
Due 15 April 1988
Resolved 15 April 1988
Construction/Loadline
Issued 15 April 1988 Resolved
CROP & RENEW TO GOOD METAL THE DAMAGED SIDE SHELL PLATE AND MAIN DECK PLATEIN THE FWD PORT VOID AREA APPROX. 3' FWD OF THE AFT COMPARTMENT BULKHEAD.
Condition: Unknown
Due 15 April 1988
Resolved 15 April 1988
Construction/Loadline
Issued 15 April 1988 Resolved
CROP & RENEW A 6" SPICOT PATCH IN STARBOARD SIDE SHELL IN GALLEY COMPART- MENT.
Condition: Unknown
Due 15 April 1988
Resolved 15 April 1988
Lifesaving
Issued 15 April 1988 Resolved
ATTACH ALL LIFEFLOATS TO THE PAINTER AND WEAK LINK IN ACCORDANCE WITH 46 CFR 180.70. THIS MUST BE COMPLETED PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 15 April 1988
Resolved 15 April 1988
Engineering
Issued 15 April 1988 Resolved
REPAIR THE EXHAUST LEAK ON THE CENTER ENGINE.
Condition: Unknown
Due 15 April 1988
Resolved 15 April 1988
Electrical
Issued 21 May 1987 Resolved
INSTALL GLOBES ON LIGHT FIXTURES WERE MISSING IN SPACE UNDER GALLEY.
Condition: Unknown
Due 21 May 1987
Resolved 21 May 1987
Unknown
Issued 21 May 1987 Resolved
INSTALL METAL CABLE TIES AS NEEDED IN ENGINE ROOM.
Condition: Unknown
Due 21 May 1987
Resolved 21 May 1987
Electrical
Issued 21 May 1987 Resolved
INSTALL BLANKS AS NEEDED IN CIRCUIT BREAKER BOX IN GALLEY.
Condition: Unknown
Due 21 May 1987
Resolved 21 May 1987
Fire Fighting
Issued 21 May 1987 Resolved
PROVIDE ONE ADDITIONAL B-II PORTABLE FIRE EXTINGUISHER IN MAIN PROPULSION MACHINERY SPACE AS PER 46 CFR 181.30-1(A).
Condition: Unknown
Due 21 May 1987
Resolved 21 May 1987
Engineering
Issued 21 May 1987 Resolved
MARK REMOTE FUEL SHUTDOWN STATIONS IN MAIN PASSENGER CABIN AS PER 46 CFR 185.30-20.
Condition: Unknown
Due 21 May 1987
Resolved 21 May 1987
Lifesaving
Issued 21 May 1987 Resolved
REPAIR OR REPLACE LIGHTS ON PFDS AS REQUIRED (31 ADULT, 6 CHILD). VESSEL IS RESTRICTED TO COASTWISE ROUTES UNTIL THIS REQUIREMENT IS SATISFIED.
Condition: Unknown
Due 21 May 1987
Resolved 21 May 1987
Unknown
Issued 21 May 1987 Resolved
PROVIDE NON-CONDUCTING MATS OR GRATING FOR DECK IN FRONT OF SWITCHBOARD IN GENERATOR SPACE PER 46 CFR 183.10-15(B).
Condition: Unknown
Due 21 May 1987
Resolved 21 May 1987
Unknown
Issued 21 May 1987 Resolved
PROVIDE SUITABLE MEANS OF INFORMING PASSENGERS OF PROPER METHOD OF DONNING PFDS AS PER 46 CFR 185.25-1(D)(2).
Condition: Unknown
Due 21 May 1987
Resolved 21 May 1987
Documentation
Issued 22 May 1986 Resolved
PROVIDE FOLLOWING; A-MIDSHIP SECT. B-OTBD PROFILE. C-INBD PROFILE. D-ARRANGOF DECKS. E-MACH INSTALLED. F-ELECT INSTALLED. G-FUEL TANKS. H-PIPE SYS. I-HULL PENETRATIONS & SHELL CONNECTIONS. J-LINES AND OFFSETS. K-CURVES OF FORM. L-SIZE LOCATION & CAPACITY OF TANKS.
Condition: Unknown
Due 22 May 1986
Resolved 22 May 1986
Documentation
Issued 22 May 1986 Resolved
OBTAIN AND PLACE ONBOARD COMMUNICATION SAFETY ACT RADIOTELEPHONE CERTIFICATE.
Condition: Unknown
Due 22 May 1986
Resolved 22 May 1986
Fire Fighting
Issued 22 May 1986 Resolved
PLACE ONBOARD A 5 GPM CAPACITY HAND FIRE PUMP.
Condition: Unknown
Due 22 May 1986
Resolved 22 May 1986
Fire Fighting
Issued 22 May 1986 Resolved
INSTALL A PRESSURE GAUGE IN THE POWER FIRE PUMP OUTLET.
Condition: Unknown
Due 22 May 1986
Resolved 22 May 1986
Deck/Cargo
Issued 22 May 1986 Resolved
INSTALL A FLAME SCREEN IN THE MSD HOLDING TANK VENT. (ON MAIN DECK STBD SIDE.)
Condition: Unknown
Due 22 May 1986
Resolved 22 May 1986
Documentation
Issued 22 May 1986 Resolved
OBTAIN AND PLACE ONBOARD CERTIFICATE OF DOCUMENTATION FROM MSO BOSTON.
Condition: Unknown
Due 22 May 1986
Resolved 22 May 1986
Documentation
Issued 22 May 1986 Resolved
OBTAIN AND POST ONBOARD STABILITY LETTER FROM CCGD8(MMT).
Condition: Unknown
Due 22 May 1986
Resolved 22 May 1986

Casualty record · 1

23 November 2010Routine · role: Involved in a Marine Casualty · activity 3905947
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.