VICTORIA STAR2

VICTORIA STAR2 is a 1976 passenger vessel (inspected). The Coast Guard has recorded 21 inspections since 2016, most recently in March 2026, along with 10 deficiencies and 1 casualty investigation in 2010.

Records from 2010 to 2026. Most recent: inspection, 25 March 2026.

Built
1976
Last inspected
25 March 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the casualty record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 25 March 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WCW4552
Flag
UNITED STATES
Maury page id
psix-48723

Documentation record

Registered dimensions (L × B × D)96.4 ft × 23.5 ft × 7.0 ft
Registered tonnagegross 99 / net 67
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDYNAMIC SHIPBUILDERS INC. · JEAN LAFITTE, LA, UNITED STATES · built 1976
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portBELLINGHAM, WA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 30 March 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it99 - Regulatory (Subpart C or D), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

21 inspections, each with its date, unit and type; 10 deficiencies with the resolution recorded against each; 1 casualty investigation, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 21

25 March 2026 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8299761
2 April 2025 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8103660
19 February 2025 Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8081756
20 March 2024 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7888384
17 May 2023 In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7690000
12 April 2023 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7667610
24 January 2023 Internal Structural Exam · Drydock Exam · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7626628
30 March 2022 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7422863
5 November 2021 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7346235
31 March 2021 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7150520
10 March 2021 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7155057
17 June 2020 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6980535
11 March 2020 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6923446
23 April 2019 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6668529
3 April 2019 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6655456
27 April 2018 Security Plan Review - VSP · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6397891
28 March 2018 Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6380900
11 April 2017 DAPI Audit · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6123350
21 March 2017 Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6108375
23 September 2016 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6007623
22 March 2016 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5840729

Deficiency record · 10

07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 March 2026 Resolved
Fire hose shall be 1 1/2 inches in diameter and 50 feet in length. If 1 inch diameter fire hose is used, each length of hose must [...] be lined commercial fire hose that conforms to Underwriters' Laboratories, Inc., Standard 19 or Federal Specification ZZ-H-451E. A hose that bears the Label of Underwriters' Laboratories, Inc., as lined fire hose is accepted as conforming to the requirement. The two hoses installed onboard the vessel were not marked UL19. O/o is to provide evidence of hoses meeting the standard or replace hoses to ones meeting the requirements stated above. 46 CFR 181.15-10(c) 46 CFR 181.15-10(d)(1)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2026
Resolved 31 March 2026
Resolution: O/o replaced hose with UL 19, 1.5" diameter hose.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 March 2026 Resolved
Have a nozzle that has a 1/2 inch solid stream orifice or a combination nozzle approved by the Commandant in accordance with § 162.027-6 of this Chapter. The nozzle must be bronze or another material that has strength and corrosion resistance properties equal to those of bronze. MI observed both hoses equipped with plastic nozzles, one of which was degraded. O/o is to replace both nozzles to meet the standard. 46 CFR 181.15-10(d)(2)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2026
Resolved 31 March 2026
Resolution: O/o replaced plastic nozzles with bronze material nozzles.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 March 2026 Resolved
Each lifeline on a ring life buoy must [...] be bouyant; be of at least 18.3 meters (60 feet) in length; be non-kinking; have a diameter of at least 7.9 millimeters (5/16 inch); have a breaking strength of at least 5 kilonewtons (1,124 pounds); and he of a dark color if synthetic, or of a type certified to be resistant to deterioration from ultraviolet light. 46 CFR 180.70(c)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2026
Resolved 31 March 2026
Resolution: O/o replaced life buoy life line with 46 CFR 180.70(c) compliant life line.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 March 2026 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. MI observed the forward starboard ring life buoy to be in unserviceable condition. O/o is to replace ring life buoy. 46 CFR 176.808(b)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2026
Resolved 31 March 2026
Resolution: O/o replaced unserviceable ring life buoy with new life buoy.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 March 2026 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. MI observed numerous [name withheld], enclosed cell type life jackets to be in unserviceable condition. O/o is to repair or replace life jackets. 46 CFR 176.808(b)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2026
Resolved 31 March 2026
Resolution: O/o replaced unserviceable lifejackets with serviceable life jackets.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 25 March 2026 Resolved
Combustibles and other foreign materials are not allowed within ventilation ducts. Dryer vent duct was found to have heavy build up. Duct to be cleaned or replaced. 46 CFR 177.600(e)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2026
Resolved 31 March 2026
Resolution: O/o replaced dryer vent duct.
01 - Certificates & Documentation › 011 - Ships Certificates › Passenger Ship Safety (including exemption)
Issued 31 March 2021 Resolved
Vessel cannot operate on an international voyage until proper PSSC and SOLAS Exemption Certificates have been issued. 46 CFR 2.01-25
Condition: Placed in Improper Service
Action required: 702 - Prior to embarking on international voyage
Due 1 August 2021
Resolved 16 April 2021
Resolution: Vessel rep has decided to skip out on getting an international route on the COI.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 11 April 2017 Resolved
Replace HRU on EPIRB.
Action required: 705 - Other - as specified
Due 14 April 2017
Resolved 14 April 2017
Resolution: Provided new EPIRB.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 11 April 2017 Resolved
Replace battery in EPIRB.
Action required: 705 - Other - as specified
Due 14 April 2017
Resolved 14 April 2017
Resolution: Replaced with new EPIRB.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 11 April 2017 Resolved
Provide non-expired eye wash.
Action required: 705 - Other - as specified
Due 11 May 2017
Resolved 14 April 2017
Resolution: Provided proof of non-expired eye wash.

Casualty record · 1

23 November 2010Routine · role: Involved in a Marine Casualty · activity 3905947