Records from 1999 to 2026. Most recent: inspection, 13 June 2026.
Inspection history · 23
13 June 2026
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8404329
10 June 2026
PSC A
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 8392848
29 October 2014
PII Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5014085
15 October 2014
PI Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 5004687
14 October 2014
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5005096
26 June 2014
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4900161
24 July 2012
Ballast Water Examination · Deficiency Check · ISPS III Exam · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4388993
2 May 2012
Deficiency Check · Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4300204
30 January 2010
COE-Offshore · ISPS I Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 3672598
26 January 2010
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3670457
17 April 2009
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3454894
16 April 2009
ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3451695
15 April 2009
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3451975
7 July 2008
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 3261071
29 October 2007
MARPOL Annex I Examination · Ballast Water Examination · MARPOL Annex V Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3086244
18 April 2006
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2627051
1 November 2003
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1939968
15 July 2002
Ballast Water Examination · Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1646522
15 July 2002
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1646616
30 March 2000
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 276274
5 March 2000
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 275416
28 July 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 431189
6 February 1999
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 425227
Operations/Management › Ballast Water Managment › Submission of Report
Issued 15 October 2014
Resolved
9900 The Master, Owner, Operator, Agent, or Person in Charge of a vessel subject to this subpart must provide the information required by 151.2070 to the USCG. Vessel failed to sumbit required information to the NBIC. 17c
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 October 2014
Resolution: Recieved email with verification from NBIC stating that they had received the reporting form from the vessel.
Electrical › Lighting (service) › Lighting Fixture
Issued 15 October 2014
Resolved
0450-No electrical equipment shall be installed in any space where flammable mixtures are liable to collect (paint locker), unless the Administration is satisfied that such equipment is ...,appropriate for space concerned, and appropriately certified for the safe usage where gasses are likely to be encountered.Light in 2nd paint locker not explosion proof. 16b
Action required: 705 - Other - as specified
Due 29 October 2014
Resolved 10 November 2014
Resolution: Recieved, reviewed, and accepted class report attesting to the replacement of the explostion proof lighting in the 2nd paint locker. Installation was verified onboard during last exam. Class report is attesting to the proper installation of lighting.
Construction/Loadline › Hull › Stiffener
Issued 15 October 2014
Resolved
0989-The condition of the ship shall be maintained to conform with the prov of the present regs to ensure that the ship in all respects will remain fit to proceed to sea without danger to ship or persons on board. PSCO identified fractures in the aft port + starboard cargo hatch coaming stiffeners for the No3 cargo hold as well as in a gusset inboard of the forward ladder to the focsle deck.50a
Action required: 705 - Other - as specified
Due 14 November 2014
Resolved 10 November 2014
Resolution: Received, reviewed, and accepted the class report verifying the repair of the fractures on the aft port and starboard cargo hatch coaming stiffeners for the No3 cargo hold. Fractured coamings were replaced with new coamings.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 15 October 2014
Resolved
Each operation described in paragraph 2 of this regulation shall be fully recorded with out delay in the oil record book part I, so that all entries in the book appropriate to that operation are completed. Bilge water transfer having occured the previous day had not yet been entered in the Oil Record Book.
Action required: 705 - Other - as specified
Resolved 15 October 2014
Resolution: Corrected on the spot to the satisfaction of the attending PSCO.
Operations/Management › Ballast Water Managment › Sediments
Issued 15 October 2014
Resolved
9900 Vessels equipped with ballast water tanks that operate in the U.S. waters must maintain a BWM plan that includes detailed fouling maintenance and sediment removal procedures. 40c
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 29 November 2014
Resolved 11 December 2014
Resolution: Vessel submitted documentation from class that BWM plan is now onboard vessel and is being reviewed by Bureau Veritas.
Electrical › Lighting (service) › Lighting Fixture
Issued 2 May 2012
Resolved
0950 - Electrical equipment in general - All electrical apparatus shall be constructed and installed as not to cause injury when handled or touched in a normal manner. Wiring for the lights above the steering gear creates a short, causing the lighting to be inoperable when touched or moved - SOLAS 74 (97 consol) Ch II-1 Reg 45.1.3 (16a/c)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 7 May 2012
Resolved 8 May 2012
Navigation › Piloting/Steering › Marine Charts
Issued 2 May 2012
Resolved
1560 - Charts - Nautical charts necessary for the intended voyage, shall be adequate and up to date. Charts onboard are the 2007 edition and have not been corrected or updated for the local area of Fernandina Fl. - SOLAS 74 (09 consol) Ch V Reg 27 (17c)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 May 2012
Resolution: Charts updated
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 2 May 2012
Resolved
0710 - Fire Prevention - Any required fixed fire detection shall be capable of immediate operation at all times. Fire detector above No.3 Auxiliary Engine was found to be inoperable - SOLAS 74 (97 consol) Ch II-2 Reg 12.1.1 (17c)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 May 2012
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 2 May 2012
Resolved
0999 - Other (safety in general) - Efficient guard rails shall be fitted to all exposed parts of the freeboard and superstructure deck and provide adequate protection to the crew. The forward portside hand rails on main deck were found wasted with broken welds. - ICLL Annex I reg 25 (16a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 May 2012
Resolved 24 July 2012
Resolution: Port side hand rail on the main deck was repaired and upon examination found to be in good condition.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 16 April 2009
Resolved
A 40kg dry chemical fire extinguisher in the engine room was found unserviced. The extinguisher is listed on the Fire Control Plan.
Action required: 705 - Other - as specified
Due 17 April 2009
Resolved 20 November 2009
Resolution: Received class report attesting to the servicing of the 40kg dry chemical fire extinguisher in the engine room.
Construction/Loadline › Hull › Bracket
Issued 16 April 2009
Resolved
Numerous broken hand rails on the main deck creating a safety hazard.
Action required: 705 - Other - as specified
Due 17 April 2009
Resolved 20 November 2009
Resolution: Received class report attesting to the repair of the broken hand rails on the main deck.
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 16 April 2009
Resolved
Two temporary repairs were found on the #1 SSG seawater cooling line not approved by Class.
Action required: 705 - Other - as specified
Due 17 April 2009
Resolved 20 November 2009
Resolution: Received class report attesting to the permanent repairs made to the #1 SSG seawater cooling line.
Engineering › Bilge Water Management System › Piping
Issued 16 April 2009
Resolved
Soft patch found on a line that runs between the Marine Sanitation Device and the bilge tank.
Action required: 705 - Other - as specified
Due 17 April 2009
Resolved 20 November 2009
Resolution: Received class report attesting to the repair of the line that runs between the marine sanitation device and the bilge tank.
Lifesaving › Inflatable Liferafts › Carriage Requirement
Issued 29 October 2007
Resolved
The forward liferaft was shackled to the deck in such a manner that would prevent the liferaft from being released manually.
SOLAS 74 Amend/ 2004 Consolidated Ed III/31.1.4
Action required: 705 - Other - as specified
Due 5 November 2007
Resolved 7 July 2008
Resolution: Received class report from BV satisfying requirement.
Fire Fighting › Portable Foam Applicators › General
Issued 29 October 2007
Resolved
Boiler space doesn't have receptacle containing sand, and doesn't have an approved foam-type extinguisher of at least 135 liters. Both are required by SOLAS unless Administration approves an alternative. SOLAS 74 Amended/ 2001 Consolidated Edition II-2/ 7.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 October 2007
Resolution: Received fax from NKK stating that the dry chemical extinguisher that the ship has would meet the requirements set forth in SOLAS. Fax is attached to the MISLE activity.
Lifesaving › Lifeboat Equipment
Issued 1 November 2003
Resolved
EACH LIFEBOAT WAS MISSING 50 SEASICK PILLS/TABLETS (100 TOTAL), A VIOLATION OF SOLAS 74/78 CHIII REG 41/8.21. CORRECT PRIOR TO DEPARTURE. LEGACY COMPONENT DESC: Anti-seasickness Medicine
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 2 November 2003
Resolved 3 November 2003
Resolution: Rcvd fax copy of receipt of purchase for the req''d pills. Def. cleared.
Fire Fighting › Fire Pumps
Issued 15 July 2002
Resolved
MAIN FIRE PUMP IN ENGINE LEAKING FROM THE SEAL LEGACY COMPONENT DESC: Seal
Condition: Improper/Lack of Maintenance
Due 15 August 2002
Resolved 1 November 2003
Resolution: CLEARED DURING AEF.
Lifesaving › Lifeboat Equipment
Issued 15 July 2002
Resolved
MAGNETIC COMPASS IN STARBOARD LIFEBOAT INOPERABLE. LEGACY COMPONENT DESC: Binnacle/Compass
Action required: 17 - Rectify deficiencies prior to departure
Due 16 July 2002
Resolved 16 July 2002
Resolution: RECEIVED RECEIPT OF PURCHASE OF MAGNETIC COMPASS
Navigation
Issued 5 March 2000
Resolved
Vessel did not have yr. 2000 updates for 1998 C.G. Light List
Condition: Unknown
Due 30 March 2000
Resolved 30 March 2000
Lifesaving
Issued 6 February 1999
Resolved
A TOTAL OF 03 SELF IGNITING LIGHT BUOYS MISSING. 01 MISSING ON THE STARBOARD SIDE AND 02 MISSING ON THE PORT SIDE.
Condition: Unknown
Due 28 July 1999
Resolved 28 July 1999