MAURY USCG vessel records
← All vessels

SANS SOUCI

SANS SOUCI is a 1976 passenger vessel (inspected). The Coast Guard has recorded 49 inspections since 2016, most recently in July 2026, along with 44 deficiencies and 16 casualty investigations between 2009 and 2026.

Records from 2009 to 2026. Most recent: inspection, 14 July 2026.

Built
1976
Last inspected
14 July 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 14 July 2026
…with no type recorded12
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WBB5017
Flag
UNITED STATES
Maury page id
psix-48728

Documentation record

Registered dimensions (L × B × D)72.0 ft × 22.5 ft × 6.8 ft
Registered tonnagegross 93 / net 63
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderLAFCO · LAFAYETTE, LA, UNITED STATES · built 1976
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSOUTHPORT, NC
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 31 July 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it93 - Regulatory (Subpart C or D), Gross Ton
63 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

RANGER Passenger (Inspected) · MISLE 799048 · 29 December 2016 · activity 6063880

Inspection history · 49

14 July 2026 Damage Survey · Administrative Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8438358
14 July 2026 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 8448635
24 March 2026 Administrative Inspection · In-Service Inspection · Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8331136
24 March 2026 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 8331259
9 February 2026 Annual Inspection · Plan Review "T" Boat · Examination of Repairs · Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8307898
14 August 2025 In-Service Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8209966
14 August 2025 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 8219308
28 July 2025 In-Service Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8196957
28 July 2025 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 8207290
23 June 2025 Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8165034
22 May 2025 Deficiency Check · In-Service Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8141937
22 May 2025 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 8146936
6 March 2025 Deficiency Check · In-Service Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8090291
6 March 2025 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 8094833
18 February 2025 Internal Structural Exam · Hull Examination
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8080548
15 April 2024 Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7895323
26 October 2023 Administrative Inspection · Plan Review "T" Boat
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 7814939
3 October 2023 Deficiency Check · Administrative Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7802419
3 October 2023 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 7802570
27 April 2023 Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7676904
17 April 2023 Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7669965
22 February 2023 Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7640260
4 October 2022 In-Service Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7571092
10 August 2022 Damage Survey · Examination of Repairs
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7529927
12 April 2022 COI Inspection · Drydock Extension
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7426250
10 November 2021 In-Service Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7348819
17 May 2021 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7198829
2 March 2021 Internal Structural Exam · Hull Examination · Administrative Inspection · Examination of Repairs
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7148611
12 January 2021 Drydock Extension
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 7123177
17 June 2020 Deficiency Check · Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6978904
23 April 2019 Annual Inspection · Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6668210
6 December 2018 Examination of Repairs · Internal Structural Exam · Drydock Exam · Administrative Inspection · Hull Examination
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6592748
9 November 2018 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6578966
27 August 2018 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6524179
9 August 2018 Administrative Inspection · Deficiency Check
Physical examination · Navigation Center · Activity 6505984
5 June 2018 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6434544
11 May 2018 Examination of Repairs · Administrative Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6414673
16 January 2018 Examination of Repairs
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6341346
2 November 2017 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6299424
1 November 2017 Damage Survey
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6306139
20 April 2017 Administrative Inspection · DAPI Audit · COI Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6128720
23 March 2017 Hull Examination · Administrative Inspection · Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6110039
13 March 2017 Damage Survey
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6104184
17 February 2017 Examination of Repairs
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6092882
9 January 2017 Examination of Repairs
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6068059
29 December 2016 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6063880
27 July 2016 Damage Survey
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 5954911
27 July 2016 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 5960327
14 June 2016 Deficiency Check · Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 5907561

Deficiency record · 44

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 February 2026 Resolved
A vessel must have two independent means of controlling each propulsion engine. Control must be provided for the engine speed, direction of shaft rotation, and engine shutdown. The new electronic control system is not functioning as required; currently, the loss of power to control system causes the loss of the primary controls without the ability to power up the auxiliary system. (46 CFR 184.620)
Action required: 60 - Rectify deficiencies prior to movement
Due 22 February 2026
Resolved 10 February 2026
Resolution: Attending inspector verified rectification.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 February 2026 Resolved
Water for cooling the exhaust pipe, other than a vertical exhaust, must be injected into the exhaust system as near to the engine manifold as practicable. The water must pass through the entire length of the exhaust pipe. Exhaust gas must not leak from the piping or any connections. There is a small hole in the starboard main engine exhaust pipe allowing exhaust gas and cooling water to leak into the engine compartment. (46 CFR 182.425/430)
Action required: 60 - Rectify deficiencies prior to movement
Due 22 February 2026
Resolved 10 February 2026
Resolution: Attending inspector verified rectification.
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 9 February 2026 Resolved
An enclosed or partially enclosed space within a vessel must be adequately ventilated in a manner suitable for the purpose of the space. The goose neck vent for the fuel tank compartment is broken at the main deck; the deck penetration may be temporarily plugged for watertight integrity. (46 CFR 177.600)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 February 2026
Resolved 10 February 2026
Resolution: Attending inspector verified rectification.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 9 February 2026 Resolved
Each watertight bulkhead must be of sufficient strength to be capable of remaining watertight with a head of of water to the top of the bulkhead. The aft bulkhead of the sewage tank compartment must be sealed where old wire runs were removed. ( 46 CFR 179.320)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 February 2026
Resolved 10 February 2026
Resolution: Attending inspector verified rectification.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 February 2026 Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, as indicated by the vessel's stability letter, the maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least 25 millimeters (1 inch) numbers and letters at the entranceway to that deck. The upper deck is not marked accordingly. (46 CFR 185.602)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 February 2026
Resolved 10 February 2026
Resolution: Attending inspector verified rectification.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 July 2025 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury; vessel reported a loss of propulsion on Port side MDE. Cause is being investigated. Vessel must effect repairs to the satisfaction of attending USCG inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 July 2025
Resolution: Attending inspector verified repairs and good operating condition.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 March 2025 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury; vessel experienced loss of propulsion. Vessel is to make repairs and successful power trial to the satisfaction of the Coast Guard. 46 CFR 182.100
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 March 2025
Resolution: 3/08/2025 accepted statement from maintenance team of repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 October 2023 Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. The port main engine is not operational and must be repaired before placing the vessel back into service.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 October 2023
Resolution: See narrative.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 April 2023 Resolved
Repair wire clamp for generator leads into gen panel
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2024
Resolved 27 April 2023
Resolution: Generator cable was properly insulated and supported.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 18 April 2023 Resolved
VHF Radio is not programmed to receive GPS input
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2023
Resolved 27 April 2023
Resolution: AIS was correctly wired to radio
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 April 2023 Resolved
Replace damaged Type I retro reflective tape on numerous lifejackets
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2023
Resolved 27 April 2023
Resolution: Worn retro tape was replaced
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 12 April 2022 Resolved
The vessel must have navigation lights that are in compliance with the inland navigation rules; the center white light in the mast does not have a proper bulb.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 April 2022
Resolved 25 April 2022
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 12 April 2022 Resolved
Each window must be capable of withstanding the maximum load from waves and wind condition expected due to it’s location; the two port light in the forward bulkhead of the cabin IWO the crews galley are broken.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 April 2022
Resolved 25 April 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 April 2022 Resolved
A life jacket must be provided for each person the vessel is authorized to carry as indicated on the COI; numerous life jackets have deteriorated reflective tape.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 April 2022
Resolved 25 April 2022
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 12 April 2022 Resolved
A vessel must carry a first aid kit, approval number 160.041, or a kit of equivalent contents; the first aid kit has expired items, eye dressing, iodine wipes, and aspirin.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 April 2022
Resolved 25 April 2022
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 17 May 2021 Resolved
A fire hose w/ nozzle must be lined commercial fire hose that conforms to UL 19; Port fire hose supplies sufficient stream of water but has several holes.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2021
Resolved 25 May 2021
Resolution: Hose was replaced
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 17 May 2021 Resolved
Each fire hydrant must have a spanner wrench suitable for removal of nozzle
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2021
Resolved 25 May 2021
Resolution: Spanner wrench was replaced
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 17 June 2020 Resolved
The marine employer must have a drug testing program in place; the existing drug consortium contract is expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 June 2020
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 17 June 2020 Resolved
A vessel must carry a first aid kit, approval number 160.041, or a kit with an equivalent contents; several items in the existing kit are expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 June 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 June 2020 Resolved
Where flexible non-metallic piping (hose) is permitted in piping systems it must meet the required specifications for its intended purpose and be otherwise acceptable to the OCMI; the connection fittings for the steering hoses are corroded beyond serviceability.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 June 2020
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 23 April 2019 Resolved
The fresh water pipe valve at the bulkhead penetration in the port muffler compartment is not operational; repair or replace as necessary.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 April 2019
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 23 April 2019 Resolved
The discharge valve on the fire pump is leaking at the packing; repack/repair as necessary.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 April 2019
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 23 April 2019 Resolved
The speaker on the back of the pilothouse is not operational; repair or replace as necessary.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 April 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 January 2019 Resolved
The bilge piping has been temporarily repaired using SAE J-1942 hose; make permanent repairs with metallic pipe IAW 46 CFR 182.710.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 February 2019
Resolved 30 January 2019
Resolution: Repairs completed and system tested.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 9 August 2018 Resolved
The vessel is currently not broadcasting (1) length and beam, (2) Draft
Condition: Invalid
Due 10 September 2018
Resolved 30 August 2018
Resolution: Vessel operator notified me that they had corrected all AIS static discrepancies. Verified in VIVS.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 5 June 2018 Resolved
Update the first aid kit to include replacement of expired items and insuring the proper quantity of inventory.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 July 2018
Resolved 25 June 2018
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 5 June 2018 Resolved
The water light has a fracture and the battery is outdated, replace the light and battery.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2018
Resolved 13 June 2018
Resolution: A new "D" cell CG approved float light was placed onboard.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 5 June 2018 Resolved
The tablet containing the electronic navigations publications has been replaced, the necessary publications have not been reloaded and the paper backup copies are out dated; make the necessary corrections to insure the vessel is equipped with all required navigation publications.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2018
Resolved 13 June 2018
Resolution: Verified onboard.
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 June 2018 Resolved
The cable on the stbd main starter is chaffing; provide chaffing gear as needed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2018
Resolved 13 June 2018
Resolution: Chaffing gear has been installed.
Engineering › Fuel Oil Service System › Valve
Issued 5 June 2018 Resolved
Provide a plug for the drain valve on the fuel tank.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2018
Resolved 13 June 2018
Resolution: Valve properly plugged.
Communications › Alarms/Indicators › Bilge Alarm
Issued 5 June 2018 Resolved
Properly secure the float switch for the bilge high level alarm IWO the engine compartment.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 June 2018
Resolved 13 June 2018
Resolution: Float switch properly secured.
Stability › Watertight Integrity › Coaming
Issued 5 June 2018 Resolved
Clean out the debris from all hatch coamings to insure a watertight seal.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2018
Resolved 13 June 2018
Resolution: All hatches have been cleaned along with gaskets.
Electrical › Lighting (service) › Lighting Fixture
Issued 5 June 2018 Resolved
Replace the broken light globe on the port side deck light.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2018
Resolved 13 June 2018
Resolution: New globe installed.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 1 November 2017 Resolved
The generator exhaust pipe is wasted and holed IWO the lazarette and muffler compartment. The use of SAE J1942 hose is authorized as a temporary repair. Permanent repairs are to be made by way of cropping and renewal as needed.
Action required: 705 - Other - as specified
Due 1 February 2018
Resolved 16 January 2018
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 20 April 2017 Resolved
Provide burn gel for the first aid kit.
Due 9 May 2017
Resolved 8 May 2017
Electrical › Electrical Distribution System (service) › Panelboard
Issued 20 April 2017 Resolved
Label the electrical panels as required.
Due 9 May 2017
Resolved 8 May 2017
Electrical › Electrical Distribution System (service) › Ground Indicator
Issued 20 April 2017 Resolved
Repair the open ground and polarity faults in two outlets.
Due 9 May 2017
Resolved 8 May 2017
Engineering › Electric Propulsion System › Fuse (overload/over current protection)
Issued 14 March 2017 Resolved
Prove proper of the port engine.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 21 March 2017
Resolved 13 March 2017
Resolution: Conducted satisfactory sea trial and witnessed proper operation of the port main engine.
Engineering › Sea-water System (primary cooling) › Pump
Issued 9 January 2017 Resolved
Failure of S/W pump on port engine caused engine overheat. Make repairs and prove proper operation to attending MI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 January 2017
Resolution: Pump replaced and sea trials conducted.
Personnel › Certificates/Documents/Licenses › License, GMDSS Radio Operator
Issued 15 June 2016 Resolved
Provide proof of FCC Radio Operator Permit for the Master.
Due 28 June 2016
Resolved 6 July 2016
Navigation › Piloting/Steering › Marine Charts
Issued 15 June 2016 Resolved
Provide redundancy for all navigation publications which are of electronic format.
Due 28 June 2016
Resolved 6 July 2016
Stability › Watertight Integrity › General
Issued 15 June 2016 Resolved
Repair or replace the gasket on the watertight hatch to the lazarette.
Due 28 June 2016
Resolved 6 July 2016
Engineering › Fuel Oil Service System › Hose
Issued 15 June 2016 Resolved
Replace the spring tension hose clampls on the fuel lines for the generator prime mover.
Due 28 June 2016
Resolved 6 July 2016
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 15 June 2016 Resolved
Properly mount the electrical outlet on the aft bulkhead of the engine compartment.
Due 28 June 2016
Resolved 6 July 2016

Casualty record · 16

7 August 2009Routine · role: Involved in a Marine Casualty · activity 3564011
7 December 2011Routine · role: Involved in a Marine Casualty · activity 4204241
1 February 2012Routine · role: Involved in a Marine Casualty · activity 4240883
23 July 2013Routine · role: Involved in a Marine Casualty · activity 4662425
26 August 2013Routine · role: Involved in a Marine Casualty · activity 4698781
27 July 2016Routine · role: Involved in a Marine Casualty · activity 5960327
29 December 2016Routine · role: Involved in a Marine Casualty · activity 6063880
27 August 2018Routine · role: Involved in a Marine Casualty · activity 6524179
9 November 2018Routine · role: Involved in a Marine Casualty · activity 6578966
3 October 2023Routine · role: Involved in a Marine Casualty · activity 7802570
6 March 2025Routine · role: Involved in a Marine Casualty · activity 8094833
22 May 2025Routine · role: Involved in a Marine Casualty · activity 8146936
28 July 2025Routine · role: Involved in a Marine Casualty · activity 8207290
14 August 2025Routine · role: Involved in a Marine Casualty · activity 8219308
24 March 2026Routine · role: Involved in a Marine Casualty · activity 8331259
14 July 2026Routine · role: Involved in a Marine Casualty · activity 8448635
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.