MAURY USCG vessel records Sign in
← All vessels

KLONDIKE EXPRESS

KLONDIKE EXPRESS is a 1999 passenger vessel (inspected). The Coast Guard has recorded 82 inspections since 1999, most recently in April 2026, along with 69 deficiencies and 7 casualty investigations between 2005 and 2019.

Records from 1999 to 2026. Most recent: inspection, 22 April 2026.

Built
1999
Last inspected
22 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8642983 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WCZ3282
487316
Flag
UNITED STATES
367020870
Maury page id
psix-487316

Inspections, by type

…with no type recorded19
Years with a record 24 calendar years (1999–2026)
The 82 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)117.2 ft × 34.0 ft × 10.0 ft
Registered tonnagegross 81 / net 55
ITC dimensions (L × B × D)117.2 ft × 34.0 ft × 10.0 ft
ITC tonnagegross 420 / net 163
BuilderNICHOLS BROTHERS BOAT BUILDERS INC · FREELAND, WA, UNITED STATES · built 1999
Hull materialAluminum
PropulsionJet Drive
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portWHITTIER, AK
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 9 February 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it120 - Displacement, Ton
133 - Dead Weight, Ton
81 - Regulatory (Subpart C or D), Gross Ton
420 - Convention (Subpart B), Gross Ton
55 - Regulatory (Subpart C or D), Net Ton
163 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WCZ3282MMSI 367020870 · active · compulsorily equipped · granted 22 March 2019, expires 10 June 2029
WDB5931MMSI 366915210 · cancelled · compulsorily equipped · granted 5 December 2003, cancelled 28 October 2013
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 82

22 April 2026 Administrative Inspection · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8320140
15 October 2025 Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 8254018
27 August 2025 In-Service Inspection · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8219168
9 April 2025 Annual Inspection · Deficiency Check · MTSA Verification
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8112394
23 April 2024 Administrative Inspection · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7891986
7 November 2023 Drydock Exam · Deficiency Check
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7821777
17 August 2023 In-Service Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7775743
1 May 2023 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7679037
18 August 2022 In-Service Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7538302
20 April 2022 COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7429834
28 September 2021 Internal Structural Exam · Drydock Exam · Examination of Repairs · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7328034
29 April 2021 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7185909
16 June 2020 Administrative Inspection · Drydock Extension
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6978757
14 May 2020 Annual Inspection · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6957394
21 October 2019 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 6838832
4 October 2019 Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 6828621
11 June 2019 Damage Survey
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 6710870
8 June 2019 Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 6710983
24 April 2019 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6668881
30 January 2019 Administrative Inspection · Deadweight Survey
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6830009
17 September 2018 Administrative Inspection · Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6548778
22 May 2018 Damage Survey
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6422366
18 May 2018 Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6431681
18 April 2018 Annual Inspection · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6394800
20 April 2017 Administrative Inspection · Plan Review (Other than "T")
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6226754
31 March 2017 MTSA Verification · DAPI Audit · COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6115462
20 October 2016 Examination of Repairs · Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6025271
2 May 2016 Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5875439
22 February 2016 Deficiency Check · Administrative Inspection · Plan Review (Other than "T")
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5825123
8 October 2014 Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5002648
26 August 2014 Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4966053
26 August 2014 Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 4980267
13 July 2011 Plan Review (Other than "T") · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4149876
30 November 2010 Internal Structural Exam · Hull Examination
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3946541
4 October 2010 Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 3863434
6 September 2010 Administrative Inspection
Administrative · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 3844808
6 September 2010 Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 3845619
1 February 2010 Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3698226
9 October 2008 Deficiency Check · Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3349687
6 October 2008 Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3339859
25 September 2008 Administrative Inspection · In-Service Inspection · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3332741
17 September 2008 Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3339852
29 July 2008 Annual Inspection · DAPI Audit · Deficiency Check · Administrative Inspection · MARPOL Annex V Examination · MTSA Verification
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3321290
31 May 2007 MARPOL Annex V Examination · COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 2952436
6 July 2006 Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 2704636
2 June 2006 Deficiency Check · Annual Inspection · MARPOL Annex V Examination · MTSA Verification
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 2671007
15 March 2006 Internal Structural Exam · Hull Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2612275
2 February 2006 Examination of Repairs
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2578065
24 January 2006 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2572306
1 December 2005 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2544898
18 October 2005 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2516052
7 June 2005 Deficiency Check · MTSA Verification · Annual Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 2384935
23 March 2005 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 2340994
25 August 2004 Examination of Repairs · Hull Examination · Damage Survey · Internal Structural Exam
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 2177584
23 August 2004 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 2176383
4 August 2004 MTSA Verification
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 2161270
8 May 2004 Annual Inspection · Administrative Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 2072165
17 February 2004 Examination of Repairs
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2005686
19 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1968318
18 November 2003 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1949986
3 October 2003 In-Service Inspection · Examination of Repairs
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1911309
5 July 2003 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1891161
24 June 2003 Annual Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1825798
21 June 2003 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1895172
21 March 2003 Administrative Inspection
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1760964
6 March 2003 Hull Examination · Examination of Repairs
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1773672
5 June 2002 COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1650290
17 April 2002 Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1607726
5 March 2002 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1491701
11 April 2001 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1362094
26 September 2000 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 15520
8 August 2000 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 128602
26 May 2000 Re-Inspection · Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1451582
13 May 2000 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 155491
12 May 2000 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 158734
1 December 1999 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 812689
21 October 1999 Examination of Repairs · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1406585
28 July 1999 Damage Survey · Examination of Repairs
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1463499
26 July 1999 Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 100286
26 June 1999 Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 773867
15 June 1999 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 810012
10 June 1999 Initial Construction-Excluding Oversight · Initial Certification
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1455743

Deficiency record · 69

09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 2 May 2023 Resolved
replace expired items in first aid kit
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2023
Resolved 22 May 2023
Resolution: all sat
16 - International Ship & Port Facility Security (ISPS) › N/A - No Subsystem › Other (maritime security)
Issued 21 April 2022 Resolved
Provide copy of annual security exercise completed in the last are or conduct annual security exercise.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2022
Resolved 28 April 2022
Resolution: all Sat
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 April 2022 Resolved
Replace all Life ring buoys onboard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2022
Resolved 28 April 2022
Resolution: all sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 April 2022 Resolved
Located exhaust leaks on both main engine and repair.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2022
Resolved 28 April 2022
Resolution: all sat
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 21 April 2022 Resolved
Provide updated Coast Pilot, CG light list and Currents table
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2022
Resolved 28 April 2022
Resolution: all sat
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 20 April 2022 Resolved
Prove proper operation of Starboard engine room bilge alarm.
Action required: 17 - Rectify deficiencies prior to departure
Due 20 April 2022
Resolved 28 April 2022
Resolution: all sat
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 20 April 2022 Resolved
prove proper operation of fire damper stop on bridge for port ventilation and fire damper
Action required: 17 - Rectify deficiencies prior to departure
Due 20 April 2022
Resolved 28 April 2022
Resolution: all sat
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 April 2022 Resolved
Repair/replace 37 Adult worn Lifejacket. Until lifejackets are repaired/replaced total adult persons onboard is reduced to 313.
Action required: 705 - Other - as specified
Due 20 April 2022
Resolved 28 April 2022
Resolution: all sat
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 20 April 2022 Resolved
Provide and post CO2 Storage warning signage as per 46 CFR 122.612 (I)(1) on door for CO2 storage .
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 April 2022
Resolved 28 April 2022
Resolution: all sat
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 20 April 2022 Resolved
Prior to carrying passengers conduct fire, abandoned ship and man overboard drills.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 April 2022
Resolved 28 April 2022
Resolution: all sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 May 2021 Resolved
Port shaft seal leaking. Replace or repair
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 May 2021
Resolution: Fixed leaking shaft seal.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 25 April 2019 Resolved
On a vessel, the fire pump must be capable of delivering a single hose stream from the highest hydrant through the hose & nozzle at a pressure of 50 psi. The stbd fire pump registered 26 psi using the forward main deck hose & nozzle (46CFR118.300(b)).
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 3 May 2019
Resolved 3 May 2019
Resolution: Witnessed Fire pump PSI at 62 psi.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 April 2019 Resolved
Table 118.500(a) indicates the minimum required number & type of extinguishers for each space listed. Vessel is missing 4-40-B-C extinguishers designated for the 2 machinery spaces. Vessel may continue to use the 4-BIIs sent for servicing if they continue to be servicable (46CFR118.500(a)).
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 May 2019
Resolution: All fire extinguishers were in place and serviced.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 25 April 2019 Resolved
The number & identification of the items stowed inside & their sizes must be marked in clearly, legible letters & numbers on each container for life jackets. Numbers & signs of adults & child lifejackets not marked on their stowage containers throughout vessel (46CFR122.604(f)).
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 May 2019
Resolved 3 May 2019
Resolution: All life jacket storage containers properly marked
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 25 April 2019 Resolved
The employer shall provide an Employee Assistance Program for all crewmembers [name withheld] education or training program available.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 May 2019
Resolution: EAP education information made available to crew members and posted.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Other (MARPOL Annex IV)
Issued 18 September 2018 Resolved
Install MSD Type III in accordance with the approved plans.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 April 2019
Resolution: Examined/cleared.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 22 May 2018 Resolved
Conduct permanent repairs by removing both Port and STBD doublers and install a proper hull inserts IWO frame #10 by next scheduled Dry Dock 10/2018.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 October 2018
Resolved 28 September 2018
Resolution: conducted satisfactory tests of permanent repairs
Operations/Management › Drills/Instruction › Not Conducted
Issued 18 April 2018 Resolved
Conduct Security drills, man overboard, fire and abandon ship drills. Provide a copy of drill logs for current crew for this calendar year. Schedule a date with new crew members for CG Observed drills.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2018
Resolved 28 September 2018
Resolution: Spoke with vsl rep who stated that def was cleared during operating season.
Operations/Management › Drills/Instruction › Not Conducted
Issued 20 April 2017 Resolved
Regular crew was not yet onboard for operating season. Conduct MOB, fire, and security drill in presence of attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 May 2017
Fire Fighting › Fire Pumps › Pressure
Issued 20 April 2017 Resolved
Repair leak in port side fire pump.
Due 5 May 2017
Resolved 2 May 2017
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 6 May 2016 Resolved
Provide alcohol test strips (46CFR4.06-15).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 May 2016
Resolved 6 May 2016
Resolution: Observed new alcohol test strips.
Navigation › Piloting/Steering › Marine Charts
Issued 3 May 2016 Resolved
Provide current Light List, Coast Pilot, Tides, Tidal Currents, & navigation charts.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 May 2016
Resolved 6 May 2016
Resolution: Observed new nav pubs @ wheelhouse.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 3 May 2016 Resolved
Renew retroreflective tape to 42 adult lifejackets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 May 2016
Resolved 6 May 2016
Resolution: Observed newly retro'd lifejackets.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 3 May 2016 Resolved
Add retroreflective tape to stbd aft ring life buoy.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 May 2016
Resolved 6 May 2016
Resolution: Observed newly installed retro.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 3 May 2016 Resolved
Update lifesaving on fire control plan.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 12 June 2017
Resolution: FCP approved.
Fire Fighting › Fire Hoses › Condition
Issued 3 May 2016 Resolved
Provide UL 19 fire hose.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 May 2016
Resolved 12 May 2016
Resolution: Rcvd confirmation of newly installed UL 19 hose.
Engineering › Fuel Oil Service System › Pump
Issued 3 May 2016 Resolved
Repair minor fuel leak on port generator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 May 2016
Resolved 6 May 2016
Resolution: Observed new part installed. Minor leak stopped.
Electrical › Electric Generation Source (service) › Generator
Issued 3 May 2016 Resolved
Install new fan belt on stbd generator.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 May 2016
Resolved 6 May 2016
Resolution: Observed newly installed fan belt.
Engineering › Diesel Engine (propulsion-reduction gear) › Injector (fuel injection)
Issued 26 August 2014 Resolved
Replace faulty fuel injector as indicated.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 August 2014
Resolution: Injector was replaced, sea trials conducted. See inspection servicing report.
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 6 September 2010 Resolved
Vessel had a Stbd MDE casualty. Does not intend to repair due to lack of time remaining in season and pending engine change at winter dry dock.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 April 2011
Resolved 28 April 2011
Resolution: Conducted satisfactory sea trial with new engines.
Construction/Loadline › Hull › Hull Plating
Issued 9 October 2008 Resolved
Gas free port & STBD long range fuel tanks spaces
Action required: 705 - Other - as specified
Resolved 21 October 2008
Resolution: Fuel tanks recieved gas free certificate
Construction/Loadline › Penetrations › Gasket
Issued 9 October 2008 Resolved
Replace Port & STBD generator & fire pump thru-hull valves
Action required: 705 - Other - as specified
Resolved 11 November 2008
Resolution: Piping replaced & leak tested to 6 PSI.
Construction/Loadline › Structures › Superstructure
Issued 9 October 2008 Resolved
Repair damage on port aft rub rail & seam
Action required: 705 - Other - as specified
Resolved 11 November 2008
Resolution: Damage to port rail repaired.
Construction/Loadline › Structures › Superstructure
Issued 9 October 2008 Resolved
Repair swim step bracket & exhaust bracket on port side
Action required: 705 - Other - as specified
Resolved 11 November 2008
Resolution: Repair completed to brackets.
Construction/Loadline › Hull › Hull Plating
Issued 9 October 2008 Resolved
Repair broken weld on port side sea chest
Action required: 705 - Other - as specified
Resolved 29 October 2008
Resolution: Weld repaired & NDT completed.
Construction/Loadline › Hull › Hull Plating
Issued 9 October 2008 Resolved
Crop / renew inset with inspection hole cut-out in port #4 void aft.
Action required: 705 - Other - as specified
Resolved 29 October 2008
Resolution: Inset completed and NDT passed.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 9 October 2008 Resolved
Provide dye penetrant test of long range fuel tank aft bulkhead IVO keel
Action required: 705 - Other - as specified
Resolved 11 November 2008
Resolution: NDT completed on upset with no evidence of cracked weld.
Engineering › Diesel Engine (propulsion-direct drive) › Crankcase
Issued 25 September 2008 Resolved
Provide repair plans for stbd MDE to Sector Anchorage & make vessel avaiable to complete enr test run / sea trials
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 October 2008
Resolution: Vessel satisfacory passed sea-trials
Construction/Loadline › Hull › Hull Plating
Issued 29 July 2008 Resolved
Crop / Remew inset on port side hull IWO eng room at next dry-dock. Provide repair plans to Sector Anchorage.
Action required: 705 - Other - as specified
Resolved 29 October 2008
Resolution: Repair plans provided and accepted. 4ft by 9 ft side shell inset installed and NDT completed.
Lifesaving › Hand Flares › Not on Board
Issued 31 May 2007 Resolved
Provide one hand-held red flare. Vessel is restricted to daylight only until flare is onboard.
Due 30 June 2007
Resolved 29 June 2007
Resolution: One hand held red flare was provided.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 31 May 2007 Resolved
Make vessel ready to perform a man overboard drill to evaluate rescue platform.
Action required: 705 - Other - as specified
Due 15 June 2007
Resolved 28 June 2007
Resolution: A satisfactory man overboard drill was held.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 31 May 2007 Resolved
Provide copy of drug program management information system (MIS).
Action required: 17 - Rectify deficiencies prior to departure
Due 31 May 2007
Resolved 31 May 2007
Resolution: Information provided 1 hour after inspection.
Documentation › Safety Management System › Conformity Maintenance Procedures
Issued 31 May 2007 Resolved
Remove expired small passenger vessel (SPV) stickers.
Due 30 June 2007
Resolved 29 June 2007
Resolution: The stickers were scrapped off the glass.
Operations/Management › Drug and Alcohol Testing › CG Notification (positive results/refusals)
Issued 6 July 2006 Resolved
During audit found that two pre-employment non-negative reports were not reported .Both were unlicensed mariners.
Condition: Unknown
Due 11 July 2006
Resolved 6 July 2006
Resolution: Provided non-negitive reports.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 6 July 2006 Resolved
Drug testing background checks. Not completed.
Condition: Unknown
Due 11 July 2006
Resolved 6 July 2006
Resolution: DER was educated on the requirements for doing background checks on new employees.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 6 July 2006 Resolved
They didn't have a copy of contract with consortium.
Due 11 July 2006
Resolved 6 July 2006
Resolution: Provided copy of the contract.
Lifesaving › Hand Flares › Expired
Issued 2 June 2006 Resolved
Remove or replace expired rescue boat flares.
Action required: 705 - Other - as specified
Due 5 July 2006
Resolved 6 June 2006
Resolution: Flares removed from service.
Fire Fighting › Fire Hoses › Condition
Issued 2 June 2006 Resolved
Replace punctured 50ft , 1 1/2" fire hose with UL 19 approved hose at fire station #4. Temporarily station 2ea B-II fire extinguishers at fire station # 4.
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 June 2006
Resolved 6 June 2006
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 18 October 2005 Resolved
Perform annual servicing of fixed firefighting system.
Action required: 705 - Other - as specified
Due 18 October 2005
Resolved 19 October 2005
Operations/Management › Vessel Safety Management › Plans for Shipboard Operations
Issued 18 October 2005 Resolved
Provide onboard a current Training & Operations Manual IAW NVIC 5-01 and NVIC 5-01, Change 1. Vsl may not operate at speeds above 30 knots until completed.
Due 18 November 2005
Resolved 1 June 2006
Resolution: Operation manual on file and delivered to vessel crew.
Electrical › Lighting (service) › Lighting Branch Circuit
Issued 18 October 2005 Resolved
Lighting power panel in upper deck passenger compartment, portside aft missing two breakers or blanks.
Due 18 October 2005
Resolved 18 October 2005
Lifesaving › Inflatable Buoyant Apparatus › Stowage
Issued 18 October 2005 Resolved
Four of the eight IBAs not properly attached to weak links.
Due 18 October 2005
Resolved 18 October 2005
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 18 October 2005 Resolved
Fire screen doors between main deck and upper deck fail to fully close.
Due 18 October 2005
Resolved 18 October 2005
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 7 June 2005 Resolved
Provide current Certificate of Documentation.
Due 7 July 2005
Resolved 18 October 2005
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 7 June 2005 Resolved
Mark emergency exit in engine room with 2 inch letters as per 46 CFR 185.606.
Due 7 July 2005
Resolved 18 October 2005
Electrical › Electric Generation Source (service) › Panelboard
Issued 7 June 2005 Resolved
Place rubber mat at switchboard. Mat must be nonconductive as per 46 CFR 183.330 (f)
Due 7 July 2005
Resolved 18 October 2005
Construction/Loadline › Structures › Scuttle
Issued 3 October 2003 Resolved
Provide securing device for #2 Port and Stbd pump room voids IAW 46 CFR 116.1160 (b)(2).
Due 3 October 2003
Resolved 3 October 2003
Engineering › Bilge Water Management System
Issued 3 October 2003 Resolved
Remove excess oil and sorbent pads from Port and Stbd engine rooms.
Due 3 October 2003
Resolved 3 October 2003
Engineering › Fuel Oil Service System › Filter
Issued 3 October 2003 Resolved
Provide flame shields in way of Port and Stbd MDE fuel filter banks.
Due 3 October 2003
Resolved 3 October 2003
Fire Fighting
Issued 26 May 2000 Resolved
Service all fire extinguishers (portable and fixed) prior to carrying pax.
Condition: Unknown
Due 14 July 2000
Resolved 14 July 2000
Lifesaving
Issued 26 May 2000 Resolved
Hold multiple drills; insure that all crew know assigned duties.
Condition: Unknown
Due 14 July 2000
Resolved 14 July 2000
Lifesaving
Issued 26 May 2000 Resolved
Restructure station bill to include more details based on drill results/feedback.
Condition: Unknown
Due 14 July 2000
Resolved 14 July 2000
Lifesaving
Issued 26 May 2000 Resolved
Hold fire and abandon ship drills to satisfaction of attending marine inspector.
Condition: Unknown
Due 14 July 2000
Resolved 14 July 2000
Construction/Loadline
Issued 28 July 1999 Resolved
Make permanent repairs to damaged bulkheads, floor frames, and hull plate from forward bulkhead of port void #3 to aft bulkhead of long range fuel tank in way of port keel, including port fuel day tank. Prior to commencing hotwork, clean and gas free fuel oil tanks.
Condition: Unknown
Due 28 July 1999
Resolved 28 July 1999
Documentation
Issued 26 June 1999 Resolved
Submit written emergency evacuation and abandon ship plan iaw 46 CFR 116.520 to [name withheld].
Condition: Unknown
Due 26 June 1999
Resolved 26 June 1999
Engineering
Issued 26 June 1999 Resolved
Provide marine chemist certificate for P/S long range fuel tanks.
Condition: Unknown
Due 26 June 1999
Resolved 30 July 1999
Fire Fighting
Issued 26 June 1999 Resolved
Conduct crew training, to include abandon ship, man overboard, fire, liferaft and marine evacuation slide deployment within 24 hrs iaw 46 CFR 122.420, 122.520, and 122.524.
Condition: Unknown
Due 13 July 1999
Resolved 30 July 1999
Engineering
Issued 10 June 1999 Resolved
CLEAN AND GAS-FREE BOTH THE PORT AND STBD LONG RANGE FUEL TANKS PRIOR TO THE CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 8 November 1999
Resolved 8 November 1999
Lifesaving
Issued 10 June 1999 Resolved
PROVIDE SECOND EMERGENCY EVACUATION SLIDE PRIOR TO THE CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 8 November 1999
Resolved 8 November 1999

Casualty record · 7

23 March 2005Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 2340994
24 January 2006Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 2572306
17 September 2008Routine · role: Involved in a Marine Casualty · activity 3339852
6 September 2010Routine · role: Involved in a Marine Casualty · activity 3845619
25 August 2012Routine · role: Involved in a Marine Casualty · activity 4423860
18 May 2018Routine · role: Involved in a Marine Casualty · activity 6431681
8 June 2019Routine · role: Involved in a Marine Casualty · activity 6710983
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.