Records from 2005 to 2026. Most recent: inspection, 22 April 2026.
Inspection history · 29
22 April 2026
Administrative Inspection · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8320140
15 October 2025
Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 8254018
27 August 2025
In-Service Inspection · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8219168
9 April 2025
Annual Inspection · Deficiency Check · MTSA Verification
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8112394
23 April 2024
Administrative Inspection · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7891986
7 November 2023
Drydock Exam · Deficiency Check
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7821777
17 August 2023
In-Service Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7775743
1 May 2023
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7679037
18 August 2022
In-Service Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7538302
20 April 2022
COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7429834
28 September 2021
Internal Structural Exam · Drydock Exam · Examination of Repairs · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7328034
29 April 2021
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7185909
16 June 2020
Administrative Inspection · Drydock Extension
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6978757
14 May 2020
Annual Inspection · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6957394
21 October 2019
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 6838832
4 October 2019
Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 6828621
11 June 2019
Damage Survey
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 6710870
8 June 2019
Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 6710983
24 April 2019
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6668881
30 January 2019
Administrative Inspection · Deadweight Survey
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6830009
17 September 2018
Administrative Inspection · Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6548778
22 May 2018
Damage Survey
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6422366
18 May 2018
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6431681
18 April 2018
Annual Inspection · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6394800
20 April 2017
Administrative Inspection · Plan Review (Other than "T")
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6226754
31 March 2017
MTSA Verification · DAPI Audit · COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6115462
20 October 2016
Examination of Repairs · Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6025271
2 May 2016
Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5875439
22 February 2016
Deficiency Check · Administrative Inspection · Plan Review (Other than "T")
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5825123
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 2 May 2023
Resolved
replace expired items in first aid kit
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2023
Resolved 22 May 2023
Resolution: all sat
16 - International Ship & Port Facility Security (ISPS) › N/A - No Subsystem › Other (maritime security)
Issued 21 April 2022
Resolved
Provide copy of annual security exercise completed in the last are or conduct annual security exercise.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2022
Resolved 28 April 2022
Resolution: all Sat
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 April 2022
Resolved
Replace all Life ring buoys onboard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2022
Resolved 28 April 2022
Resolution: all sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 April 2022
Resolved
Located exhaust leaks on both main engine and repair.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2022
Resolved 28 April 2022
Resolution: all sat
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 21 April 2022
Resolved
Provide updated Coast Pilot, CG light list and Currents table
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2022
Resolved 28 April 2022
Resolution: all sat
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 20 April 2022
Resolved
Prove proper operation of Starboard engine room bilge alarm.
Action required: 17 - Rectify deficiencies prior to departure
Due 20 April 2022
Resolved 28 April 2022
Resolution: all sat
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 20 April 2022
Resolved
prove proper operation of fire damper stop on bridge for port ventilation and fire damper
Action required: 17 - Rectify deficiencies prior to departure
Due 20 April 2022
Resolved 28 April 2022
Resolution: all sat
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 April 2022
Resolved
Repair/replace 37 Adult worn Lifejacket. Until lifejackets are repaired/replaced total adult persons onboard is reduced to 313.
Action required: 705 - Other - as specified
Due 20 April 2022
Resolved 28 April 2022
Resolution: all sat
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 20 April 2022
Resolved
Provide and post CO2 Storage warning signage as per 46 CFR 122.612 (I)(1) on door for CO2 storage .
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 April 2022
Resolved 28 April 2022
Resolution: all sat
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 20 April 2022
Resolved
Prior to carrying passengers conduct fire, abandoned ship and man overboard drills.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 April 2022
Resolved 28 April 2022
Resolution: all sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 May 2021
Resolved
Port shaft seal leaking. Replace or repair
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 May 2021
Resolution: Fixed leaking shaft seal.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 25 April 2019
Resolved
On a vessel, the fire pump must be capable of delivering a single hose stream from the highest hydrant through the hose & nozzle at a pressure of 50 psi. The stbd fire pump registered 26 psi using the forward main deck hose & nozzle (46CFR118.300(b)).
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 3 May 2019
Resolved 3 May 2019
Resolution: Witnessed Fire pump PSI at 62 psi.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 April 2019
Resolved
Table 118.500(a) indicates the minimum required number & type of extinguishers for each space listed. Vessel is missing 4-40-B-C extinguishers designated for the 2 machinery spaces. Vessel may continue to use the 4-BIIs sent for servicing if they continue to be servicable (46CFR118.500(a)).
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 May 2019
Resolution: All fire extinguishers were in place and serviced.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 25 April 2019
Resolved
The number & identification of the items stowed inside & their sizes must be marked in clearly, legible letters & numbers on each container for life jackets. Numbers & signs of adults & child lifejackets not marked on their stowage containers throughout vessel (46CFR122.604(f)).
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 May 2019
Resolved 3 May 2019
Resolution: All life jacket storage containers properly marked
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 25 April 2019
Resolved
The employer shall provide an Employee Assistance Program for all crewmembers [name withheld] education or training program available.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 May 2019
Resolution: EAP education information made available to crew members and posted.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Other (MARPOL Annex IV)
Issued 18 September 2018
Resolved
Install MSD Type III in accordance with the approved plans.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 April 2019
Resolution: Examined/cleared.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 22 May 2018
Resolved
Conduct permanent repairs by removing both Port and STBD doublers and install a proper hull inserts IWO frame #10 by next scheduled Dry Dock 10/2018.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 October 2018
Resolved 28 September 2018
Resolution: conducted satisfactory tests of permanent repairs
Operations/Management › Drills/Instruction › Not Conducted
Issued 18 April 2018
Resolved
Conduct Security drills, man overboard, fire and abandon ship drills. Provide a copy of drill logs for current crew for this calendar year. Schedule a date with new crew members for CG Observed drills.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2018
Resolved 28 September 2018
Resolution: Spoke with vsl rep who stated that def was cleared during operating season.
Operations/Management › Drills/Instruction › Not Conducted
Issued 20 April 2017
Resolved
Regular crew was not yet onboard for operating season. Conduct MOB, fire, and security drill in presence of attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 May 2017
Fire Fighting › Fire Pumps › Pressure
Issued 20 April 2017
Resolved
Repair leak in port side fire pump.
Due 5 May 2017
Resolved 2 May 2017
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 6 May 2016
Resolved
Provide alcohol test strips (46CFR4.06-15).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 May 2016
Resolved 6 May 2016
Resolution: Observed new alcohol test strips.
Navigation › Piloting/Steering › Marine Charts
Issued 3 May 2016
Resolved
Provide current Light List, Coast Pilot, Tides, Tidal Currents, & navigation charts.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 May 2016
Resolved 6 May 2016
Resolution: Observed new nav pubs @ wheelhouse.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 3 May 2016
Resolved
Renew retroreflective tape to 42 adult lifejackets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 May 2016
Resolved 6 May 2016
Resolution: Observed newly retro'd lifejackets.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 3 May 2016
Resolved
Add retroreflective tape to stbd aft ring life buoy.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 May 2016
Resolved 6 May 2016
Resolution: Observed newly installed retro.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 3 May 2016
Resolved
Update lifesaving on fire control plan.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 12 June 2017
Resolution: FCP approved.
Fire Fighting › Fire Hoses › Condition
Issued 3 May 2016
Resolved
Provide UL 19 fire hose.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 May 2016
Resolved 12 May 2016
Resolution: Rcvd confirmation of newly installed UL 19 hose.
Engineering › Fuel Oil Service System › Pump
Issued 3 May 2016
Resolved
Repair minor fuel leak on port generator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 May 2016
Resolved 6 May 2016
Resolution: Observed new part installed. Minor leak stopped.
Electrical › Electric Generation Source (service) › Generator
Issued 3 May 2016
Resolved
Install new fan belt on stbd generator.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 May 2016
Resolved 6 May 2016
Resolution: Observed newly installed fan belt.