Records from 1998 to 2025. Most recent: inspection, 2 October 2025.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 39
2 October 2025
Administrative Inspection · COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8237656
4 December 2024
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8042499
31 October 2024
Internal Structural Exam · Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8022707
20 December 2023
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7840590
3 October 2023
In-Service Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7802372
14 December 2022
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7608311
26 October 2022
Hull Examination · Internal Structural Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7583543
13 October 2022
Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7576688
23 November 2021
Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7355485
7 October 2020
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7072171
25 September 2020
DAPI Audit · Administrative Inspection · COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7063598
14 November 2019
Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6854035
8 January 2019
Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6606566
2 October 2018
Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6552346
12 December 2017
Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6320398
7 December 2016
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6044981
17 November 2016
Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6028422
15 July 2015
COI Inspection · DAPI Audit
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5150156
1 February 2012
Administrative Inspection · Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 4235160
17 November 2010
Administrative Inspection · COI Inspection · DAPI Audit · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3879255
18 February 2010
Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3681527
4 January 2010
Administrative Inspection · Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3917780
14 January 2009
Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3388637
21 October 2008
Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3362818
5 November 2007
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3087394
24 January 2007
Administrative Inspection · Annual Inspection · Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2859722
15 November 2005
COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2534826
16 March 2005
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2310565
1 February 2005
Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2284207
14 January 2004
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1988710
5 February 2003
Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1739190
7 January 2003
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1726583
26 November 2001
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1468679
25 September 2001
Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1075270
9 January 2001
Re-Inspection · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1439139
1 March 2000
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1046484
11 January 2000
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1403085
23 December 1998
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1472238
2 December 1998
Initial Certification · Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1472920
Navigation › Piloting/Steering › Marine Charts
Issued 1 February 2012
Resolved
Provide on board a current chart for vessel's route IAW 46 CFR 184.420.
Action required: 705 - Other - as specified
Due 8 February 2012
Resolved 2 February 2012
Navigation › Piloting/Steering › Coast Guard Light List
Issued 17 November 2010
Resolved
Provided current light list, Coast Pilot, and tides and currents onboard. Vessel currently does not have any onboard.
Action required: 705 - Other - as specified
Due 14 December 2010
Resolved 14 December 2010
Resolution: Vessel has onboard current light list, Coast Pilot, and tides and currents for operating area.
Navigation › Piloting/Steering › Marine Charts
Issued 17 November 2010
Resolved
Provided update charts/chart corrections onboard. Vessels charts onboard are from 2006 with no corrections.
Action required: 705 - Other - as specified
Due 14 December 2010
Resolved 14 December 2010
Resolution: Vessel has onboard charts with up to date corrections.
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 17 November 2010
Resolved
Ensure/prove proper operation of RPM gauge at the operating station. RPM gauge not operating.
Action required: 705 - Other - as specified
Due 16 December 2010
Resolved 14 December 2010
Resolution: RPM gauge operating as required.
Lifesaving › Hand Flares › Storage
Issued 17 November 2010
Resolved
Provided a watertight container (bright in color) marked "DISTRESS SIGNALS" for distress flares.
Action required: 705 - Other - as specified
Due 14 December 2010
Resolved 14 December 2010
Resolution: Watertight container is onboard and marked as required.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 17 November 2010
Resolved
Provide all around white anchor light for the vessel. Vessel currently does not have onboard an all around white light.
Action required: 705 - Other - as specified
Due 16 December 2010
Resolved 14 December 2010
Resolution: Vessel has all around white light as required by Nav Rules for anchoring.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 17 November 2010
Resolved
Provide proof of EAP for all crew members and supervisors.
Action required: 705 - Other - as specified
Due 16 December 2010
Resolved 14 December 2010
Resolution: EAP has been implemented for all crew mwmbers and supervisors. Phone numbers are posted and training has been complete.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 17 November 2010
Resolved
Provide/submit MIS report to CG-MOA at address provided.
Action required: 705 - Other - as specified
Due 16 December 2010
Resolved 14 December 2010
Resolution: Proof of MIS report submission was provided.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 21 October 2008
Resolved
Repair ring lifebuoy light
Due 22 October 2008
Resolved 22 October 2008
Communications › Alarms/Indicators › Bilge Alarm
Issued 21 October 2008
Resolved
Repair bilge high level alarm
Due 22 October 2008
Resolved 22 October 2008
Electrical › Electrical Distribution System (service) › Switch
Issued 21 October 2008
Resolved
Mark switch at helm
Due 22 October 2008
Resolved 22 October 2008
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 1 February 2007
Resolved
REPAIR NAVIGATION LIGHTS
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 February 2007
Documentation › Logs/Records › Logbook (official)
Issued 1 February 2007
Resolved
PROVIDE TRAINING LOGBOOK.
Due 8 February 2007
Resolved 21 February 2007
Documentation › Logs/Records › Drug Test Records
Issued 1 February 2007
Resolved
PROVIDE DRUG PROGRAM DOCUMENTS.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 February 2007
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 24 January 2007
Resolved
INSTALL DECK RAIL PORT SIDE
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 February 2007
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 24 January 2007
Resolved
REPLACE FIRST AID KIT.
Due 8 February 2007
Resolved 21 February 2007
Engineering › Bilge Water Management System › Not Installed
Issued 24 January 2007
Resolved
INSTALL BILGE HIGH LEVEL ALARM WITH VISIBLE AND AUDIBLE ALARM AT OPERATING STATION.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 February 2007
Engineering › Shafting/Propeller Arrangements › Coupling
Issued 15 November 2005
Resolved
Make permanent repairs to leaking shaft log.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 November 2005
Resolved 23 November 2005
Documentation › Logs/Records › Drug Test Records
Issued 15 November 2005
Resolved
Provide evidence of SMI and testing procedures through APAP.
Due 30 November 2005
Resolved 23 November 2005
Documentation › Manuals/Policy Documentation › Training Manual (lifesaving)
Issued 15 November 2005
Resolved
Provide evidence of CPR/First Aid training for 50% of the crew.
Due 30 November 2005
Resolved 23 November 2005
Fire Fighting › Fixed Gas Fire Extinguishing System › Nozzle
Issued 15 November 2005
Resolved
Provide service report for the fixed gas system.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 November 2005
Resolved 23 November 2005
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 15 November 2005
Resolved
Provide current training logbook w/ drills and description of traininig procedures.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 November 2005
Resolved 23 November 2005
Lifesaving › Lifebuoys › Approval
Issued 15 November 2005
Resolved
Provide ring buoy with all associated compliments.
Action required: 705 - Other - as specified
Due 30 November 2005
Resolved 23 November 2005
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 15 November 2005
Resolved
Replace all expired items in the first aid kit.
Action required: 705 - Other - as specified
Due 30 November 2005
Resolved 23 November 2005
Fire Fighting › Fire Bucket › Quantity
Issued 15 November 2005
Resolved
Provide one additional fire bucket.
Action required: 705 - Other - as specified
Due 30 November 2005
Resolved 23 November 2005
Operations/Management › Passenger Operations › Safety Orientation
Issued 15 November 2005
Resolved
Provide emergency phone contact list at the operating station.
Action required: 705 - Other - as specified
Due 30 November 2005
Resolved 23 November 2005
Electrical › Electric Generation Source (service) › Conductor
Issued 15 November 2005
Resolved
Replace wing nuts on battery posts
Action required: 705 - Other - as specified
Due 30 November 2005
Resolved 23 November 2005
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 15 November 2005
Resolved
Ensure all lifejackets are appropriately stenciled.
Action required: 705 - Other - as specified
Due 30 November 2005
Resolved 23 November 2005
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 16 March 2005
Resolved
PROVIDE REQUIRED REDUCED MANNING INFORMATION.
Due 16 April 2005
Resolved 23 November 2005
Navigation › Collision/Grounding Avoidance › Danger Messages
Issued 16 March 2005
Resolved
PROVIDE AN OPERATIONAL HORN ONBOARD VESSEL.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 April 2005
Resolved 23 November 2005
Lifesaving › Lifebuoys › Serviceable
Issued 16 March 2005
Resolved
SCRUB MILDEW OF OF RING BOUY AND APPLY RETRO TAPE TO BACKSIDE OF BOUY.
Due 16 April 2005
Resolved 23 November 2005
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 16 March 2005
Resolved
RE-PACK SHAFT LOG TO REDUCE EXCESSIVE LEAKAGE.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 April 2005
Resolved 23 November 2005
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 16 March 2005
Resolved
PROVIDE TWO OPERATIONAL FLASHLIGHTS ONBOARD.
Due 16 April 2005
Resolved 23 November 2005
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 14 January 2004
Resolved
REPLACE P/S RUNNING LIGHT BULB.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 January 2004
Resolved 14 January 2004
Lifesaving › Hand Flares › Quantity
Issued 14 January 2004
Resolved
PROVIDE 3 ADDITIONAL HAND RED OR ORANGE SMOKE CG APPROVED DISTRESS SIGNALS ONBOARD.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 January 2004
Resolved 14 January 2004
Navigation › Piloting/Steering › Marine Charts
Issued 14 January 2004
Resolved
PROVIDE A NAVIGATION CHART OF VESSELS AREA OF OPERATION.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 January 2004
Resolved 14 January 2004
Fire Fighting
Issued 26 November 2001
Resolved
PROVIDE SERVICE REPORT FOR FIXED FIRE FIGHTING SYSTEM.
Condition: Unknown
Due 26 December 2001
Resolved 7 January 2003
Lifesaving
Issued 11 January 2000
Resolved
DEVELOP PROCEDURE FOR CONDUCTING PASSENGER COUNT AT BOTH VESSEL MOORINGS.
Condition: Unknown
Due 21 March 2000
Resolved 21 March 2000
Lifesaving
Issued 11 January 2000
Resolved
PROVIDE AN APPROVED FIRST AID KIT IN ACCORDANCE WITH 46CFR160.041-4.
Condition: Unknown
Due 21 March 2000
Resolved 21 March 2000
Lifesaving
Issued 11 January 2000
Resolved
INSTALL RETRO-REFLECTIVE TAPE ON RING BUOY.
Condition: Unknown
Due 21 March 2000
Resolved 21 March 2000
Lifesaving
Issued 11 January 2000
Resolved
PROVIDE AND INSTALL PFD DONNING PLACARDS.
Condition: Unknown
Due 21 March 2000
Resolved 21 March 2000
Fire Fighting
Issued 11 January 2000
Resolved
CONDUCT FULL FUNCTIONAL SERVICING OF FIXED HALON SYSTEM.
Condition: Unknown
Due 21 March 2000
Resolved 21 March 2000
Fire Fighting
Issued 11 January 2000
Resolved
PROVIDE AND INSTALL 1 BII PORTABLE FIRE EXTINGUISHER.
Condition: Unknown
Due 21 March 2000
Resolved 21 March 2000
Engineering
Issued 11 January 2000
Resolved
INSTALL PROTECTIVE GUARD ON FRONT OF MAIN ENGINE.
Condition: Unknown
Due 21 March 2000
Resolved 21 March 2000
Construction/Loadline
Issued 11 January 2000
Resolved
INSTALL HIGH BILGE ALARMS IN ENGINE COMPARTMENT AND LAZARETTE.
Condition: Unknown
Due 21 March 2000
Resolved 21 March 2000
Lifesaving
Issued 23 December 1998
Resolved
INSTALL RETRO TAPE ON RING BUOY._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 December 1998
Resolved 24 February 1999
Fire Fighting
Issued 23 December 1998
Resolved
INSTALL LINES ON ALL 3 FIRE BUCKETS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 December 1998
Resolved 24 February 1999
Lifesaving
Issued 23 December 1998
Resolved
PROVIDE 3 ORANGE AND 3 RED FLARES STORED IN A BRIGHT COLORED WATERTIGHT CONTAINER LABELED DISTRESS SIGNALS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 December 1998
Resolved 24 February 1999
Engineering
Issued 23 December 1998
Resolved
PROVIDE MEANS OF CLOSING ENGINE ROOM VENTS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 December 1998
Resolved 24 February 1999
Lifesaving
Issued 23 December 1998
Resolved
INSTALL HALYARD CLIP ON END OF RING BUOY WATERLIGHT LINE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 December 1998
Resolved 24 February 1999
Lifesaving
Issued 2 December 1998
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 2 December 1998
Resolved 2 December 1998