MAURY USCG vessel records Sign in
← All vessels

HALF MOON

HALF MOON is a 1998 passenger vessel (inspected). The Coast Guard has recorded 39 inspections since 1998, most recently in October 2025, along with 51 deficiencies.

Records from 1998 to 2025. Most recent: inspection, 2 October 2025.

Built
1998
Last inspected
2 October 2025
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

487321
Flag
UNITED STATES
—
Maury page id
psix-487321

Inspections, by type

…with no type recorded1
Years with a record 22 calendar years (1998–2025)
The 39 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it4 - Regulatory (Subpart C or D), Gross Ton
4 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 39

2 October 2025 Administrative Inspection · COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8237656
4 December 2024 Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8042499
31 October 2024 Internal Structural Exam · Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8022707
20 December 2023 Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7840590
3 October 2023 In-Service Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7802372
14 December 2022 Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7608311
26 October 2022 Hull Examination · Internal Structural Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7583543
13 October 2022 Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7576688
23 November 2021 Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7355485
7 October 2020 Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7072171
25 September 2020 DAPI Audit · Administrative Inspection · COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7063598
14 November 2019 Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6854035
8 January 2019 Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6606566
2 October 2018 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6552346
12 December 2017 Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6320398
7 December 2016 Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6044981
17 November 2016 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6028422
15 July 2015 COI Inspection · DAPI Audit
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5150156
1 February 2012 Administrative Inspection · Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 4235160
17 November 2010 Administrative Inspection · COI Inspection · DAPI Audit · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3879255
18 February 2010 Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3681527
4 January 2010 Administrative Inspection · Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3917780
14 January 2009 Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3388637
21 October 2008 Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3362818
5 November 2007 Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3087394
24 January 2007 Administrative Inspection · Annual Inspection · Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2859722
15 November 2005 COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2534826
16 March 2005 Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2310565
1 February 2005 Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2284207
14 January 2004 Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1988710
5 February 2003 Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1739190
7 January 2003 Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1726583
26 November 2001 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1468679
25 September 2001 Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1075270
9 January 2001 Re-Inspection · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1439139
1 March 2000 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1046484
11 January 2000 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1403085
23 December 1998 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1472238
2 December 1998 Initial Certification · Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1472920

Deficiency record · 51

Navigation › Piloting/Steering › Marine Charts
Issued 1 February 2012 Resolved
Provide on board a current chart for vessel's route IAW 46 CFR 184.420.
Action required: 705 - Other - as specified
Due 8 February 2012
Resolved 2 February 2012
Navigation › Piloting/Steering › Coast Guard Light List
Issued 17 November 2010 Resolved
Provided current light list, Coast Pilot, and tides and currents onboard. Vessel currently does not have any onboard.
Action required: 705 - Other - as specified
Due 14 December 2010
Resolved 14 December 2010
Resolution: Vessel has onboard current light list, Coast Pilot, and tides and currents for operating area.
Navigation › Piloting/Steering › Marine Charts
Issued 17 November 2010 Resolved
Provided update charts/chart corrections onboard. Vessels charts onboard are from 2006 with no corrections.
Action required: 705 - Other - as specified
Due 14 December 2010
Resolved 14 December 2010
Resolution: Vessel has onboard charts with up to date corrections.
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 17 November 2010 Resolved
Ensure/prove proper operation of RPM gauge at the operating station. RPM gauge not operating.
Action required: 705 - Other - as specified
Due 16 December 2010
Resolved 14 December 2010
Resolution: RPM gauge operating as required.
Lifesaving › Hand Flares › Storage
Issued 17 November 2010 Resolved
Provided a watertight container (bright in color) marked "DISTRESS SIGNALS" for distress flares.
Action required: 705 - Other - as specified
Due 14 December 2010
Resolved 14 December 2010
Resolution: Watertight container is onboard and marked as required.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 17 November 2010 Resolved
Provide all around white anchor light for the vessel. Vessel currently does not have onboard an all around white light.
Action required: 705 - Other - as specified
Due 16 December 2010
Resolved 14 December 2010
Resolution: Vessel has all around white light as required by Nav Rules for anchoring.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 17 November 2010 Resolved
Provide proof of EAP for all crew members and supervisors.
Action required: 705 - Other - as specified
Due 16 December 2010
Resolved 14 December 2010
Resolution: EAP has been implemented for all crew mwmbers and supervisors. Phone numbers are posted and training has been complete.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 17 November 2010 Resolved
Provide/submit MIS report to CG-MOA at address provided.
Action required: 705 - Other - as specified
Due 16 December 2010
Resolved 14 December 2010
Resolution: Proof of MIS report submission was provided.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 21 October 2008 Resolved
Repair ring lifebuoy light
Due 22 October 2008
Resolved 22 October 2008
Communications › Alarms/Indicators › Bilge Alarm
Issued 21 October 2008 Resolved
Repair bilge high level alarm
Due 22 October 2008
Resolved 22 October 2008
Electrical › Electrical Distribution System (service) › Switch
Issued 21 October 2008 Resolved
Mark switch at helm
Due 22 October 2008
Resolved 22 October 2008
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 1 February 2007 Resolved
REPAIR NAVIGATION LIGHTS
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 February 2007
Documentation › Logs/Records › Logbook (official)
Issued 1 February 2007 Resolved
PROVIDE TRAINING LOGBOOK.
Due 8 February 2007
Resolved 21 February 2007
Documentation › Logs/Records › Drug Test Records
Issued 1 February 2007 Resolved
PROVIDE DRUG PROGRAM DOCUMENTS.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 February 2007
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 24 January 2007 Resolved
INSTALL DECK RAIL PORT SIDE
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 February 2007
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 24 January 2007 Resolved
REPLACE FIRST AID KIT.
Due 8 February 2007
Resolved 21 February 2007
Engineering › Bilge Water Management System › Not Installed
Issued 24 January 2007 Resolved
INSTALL BILGE HIGH LEVEL ALARM WITH VISIBLE AND AUDIBLE ALARM AT OPERATING STATION.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 February 2007
Engineering › Shafting/Propeller Arrangements › Coupling
Issued 15 November 2005 Resolved
Make permanent repairs to leaking shaft log.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 November 2005
Resolved 23 November 2005
Documentation › Logs/Records › Drug Test Records
Issued 15 November 2005 Resolved
Provide evidence of SMI and testing procedures through APAP.
Due 30 November 2005
Resolved 23 November 2005
Documentation › Manuals/Policy Documentation › Training Manual (lifesaving)
Issued 15 November 2005 Resolved
Provide evidence of CPR/First Aid training for 50% of the crew.
Due 30 November 2005
Resolved 23 November 2005
Fire Fighting › Fixed Gas Fire Extinguishing System › Nozzle
Issued 15 November 2005 Resolved
Provide service report for the fixed gas system.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 November 2005
Resolved 23 November 2005
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 15 November 2005 Resolved
Provide current training logbook w/ drills and description of traininig procedures.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 November 2005
Resolved 23 November 2005
Lifesaving › Lifebuoys › Approval
Issued 15 November 2005 Resolved
Provide ring buoy with all associated compliments.
Action required: 705 - Other - as specified
Due 30 November 2005
Resolved 23 November 2005
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 15 November 2005 Resolved
Replace all expired items in the first aid kit.
Action required: 705 - Other - as specified
Due 30 November 2005
Resolved 23 November 2005
Fire Fighting › Fire Bucket › Quantity
Issued 15 November 2005 Resolved
Provide one additional fire bucket.
Action required: 705 - Other - as specified
Due 30 November 2005
Resolved 23 November 2005
Operations/Management › Passenger Operations › Safety Orientation
Issued 15 November 2005 Resolved
Provide emergency phone contact list at the operating station.
Action required: 705 - Other - as specified
Due 30 November 2005
Resolved 23 November 2005
Electrical › Electric Generation Source (service) › Conductor
Issued 15 November 2005 Resolved
Replace wing nuts on battery posts
Action required: 705 - Other - as specified
Due 30 November 2005
Resolved 23 November 2005
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 15 November 2005 Resolved
Ensure all lifejackets are appropriately stenciled.
Action required: 705 - Other - as specified
Due 30 November 2005
Resolved 23 November 2005
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 16 March 2005 Resolved
PROVIDE REQUIRED REDUCED MANNING INFORMATION.
Due 16 April 2005
Resolved 23 November 2005
Navigation › Collision/Grounding Avoidance › Danger Messages
Issued 16 March 2005 Resolved
PROVIDE AN OPERATIONAL HORN ONBOARD VESSEL.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 April 2005
Resolved 23 November 2005
Lifesaving › Lifebuoys › Serviceable
Issued 16 March 2005 Resolved
SCRUB MILDEW OF OF RING BOUY AND APPLY RETRO TAPE TO BACKSIDE OF BOUY.
Due 16 April 2005
Resolved 23 November 2005
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 16 March 2005 Resolved
RE-PACK SHAFT LOG TO REDUCE EXCESSIVE LEAKAGE.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 April 2005
Resolved 23 November 2005
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 16 March 2005 Resolved
PROVIDE TWO OPERATIONAL FLASHLIGHTS ONBOARD.
Due 16 April 2005
Resolved 23 November 2005
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 14 January 2004 Resolved
REPLACE P/S RUNNING LIGHT BULB.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 January 2004
Resolved 14 January 2004
Lifesaving › Hand Flares › Quantity
Issued 14 January 2004 Resolved
PROVIDE 3 ADDITIONAL HAND RED OR ORANGE SMOKE CG APPROVED DISTRESS SIGNALS ONBOARD.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 January 2004
Resolved 14 January 2004
Navigation › Piloting/Steering › Marine Charts
Issued 14 January 2004 Resolved
PROVIDE A NAVIGATION CHART OF VESSELS AREA OF OPERATION.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 January 2004
Resolved 14 January 2004
Fire Fighting
Issued 26 November 2001 Resolved
PROVIDE SERVICE REPORT FOR FIXED FIRE FIGHTING SYSTEM.
Condition: Unknown
Due 26 December 2001
Resolved 7 January 2003
Lifesaving
Issued 11 January 2000 Resolved
DEVELOP PROCEDURE FOR CONDUCTING PASSENGER COUNT AT BOTH VESSEL MOORINGS.
Condition: Unknown
Due 21 March 2000
Resolved 21 March 2000
Lifesaving
Issued 11 January 2000 Resolved
PROVIDE AN APPROVED FIRST AID KIT IN ACCORDANCE WITH 46CFR160.041-4.
Condition: Unknown
Due 21 March 2000
Resolved 21 March 2000
Lifesaving
Issued 11 January 2000 Resolved
INSTALL RETRO-REFLECTIVE TAPE ON RING BUOY.
Condition: Unknown
Due 21 March 2000
Resolved 21 March 2000
Lifesaving
Issued 11 January 2000 Resolved
PROVIDE AND INSTALL PFD DONNING PLACARDS.
Condition: Unknown
Due 21 March 2000
Resolved 21 March 2000
Fire Fighting
Issued 11 January 2000 Resolved
CONDUCT FULL FUNCTIONAL SERVICING OF FIXED HALON SYSTEM.
Condition: Unknown
Due 21 March 2000
Resolved 21 March 2000
Fire Fighting
Issued 11 January 2000 Resolved
PROVIDE AND INSTALL 1 BII PORTABLE FIRE EXTINGUISHER.
Condition: Unknown
Due 21 March 2000
Resolved 21 March 2000
Engineering
Issued 11 January 2000 Resolved
INSTALL PROTECTIVE GUARD ON FRONT OF MAIN ENGINE.
Condition: Unknown
Due 21 March 2000
Resolved 21 March 2000
Construction/Loadline
Issued 11 January 2000 Resolved
INSTALL HIGH BILGE ALARMS IN ENGINE COMPARTMENT AND LAZARETTE.
Condition: Unknown
Due 21 March 2000
Resolved 21 March 2000
Lifesaving
Issued 23 December 1998 Resolved
INSTALL RETRO TAPE ON RING BUOY._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 December 1998
Resolved 24 February 1999
Fire Fighting
Issued 23 December 1998 Resolved
INSTALL LINES ON ALL 3 FIRE BUCKETS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 December 1998
Resolved 24 February 1999
Lifesaving
Issued 23 December 1998 Resolved
PROVIDE 3 ORANGE AND 3 RED FLARES STORED IN A BRIGHT COLORED WATERTIGHT CONTAINER LABELED DISTRESS SIGNALS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 December 1998
Resolved 24 February 1999
Engineering
Issued 23 December 1998 Resolved
PROVIDE MEANS OF CLOSING ENGINE ROOM VENTS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 December 1998
Resolved 24 February 1999
Lifesaving
Issued 23 December 1998 Resolved
INSTALL HALYARD CLIP ON END OF RING BUOY WATERLIGHT LINE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 December 1998
Resolved 24 February 1999
Lifesaving
Issued 2 December 1998 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 2 December 1998
Resolved 2 December 1998

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.