Documentation record
Registered dimensions (L × B × D)47.5 ft × 15.7 ft × 6.7 ft
Registered tonnagegross 37 / net 26
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDELTA MARINE INDUSTRIES · SEATTLE, WA, UNITED STATES · built 1976
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSEWARD, AK
Endorsements, as the file codes themcw_un, fi, reg
DocumentationValid · issued 25 April 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it37 - Regulatory (Subpart C or D), Gross Ton
26 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 22
28 April 2026
Internal Structural Exam · Administrative Inspection · COI Inspection · Deficiency Check · Drydock Exam
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 8357033
3 July 2024
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7950686
6 June 2024
Drydock Exam · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7926538
10 April 2024
Liferaft Servicing
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7897830
15 August 2023
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7769367
11 August 2022
Type not recorded
No type recorded · Maritime Safety & Security Team San Francisco (91105) · Activity 7531312
6 July 2022
Administrative Inspection · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7498381
2 June 2022
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7460155
2 June 2021
Deficiency Check · Examination of Repairs · Drydock Exam · COI Inspection · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7221423
26 August 2020
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7043206
19 August 2020
Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7037599
31 July 2020
Type not recorded
No type recorded · USCGC CHANDELEUR (WPB 1319) · USCG Arctic District (CGD-A) · Activity 7023782
18 May 2020
Administrative Inspection
Administrative · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 6955480
11 October 2019
In-Service Inspection · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6832972
6 August 2019
Annual Inspection · Deficiency Check
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 6776305
4 September 2018
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6532288
5 April 2018
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6390686
8 June 2017
Type not recorded
No type recorded · USCGC MUSTANG (WPB 1310) · USCG Arctic District (CGD-A) · Activity 6174783
1 June 2017
Annual Inspection · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6181791
16 July 2016
Type not recorded
No type recorded · USCGC MUSTANG (WPB 1310) · USCG Arctic District (CGD-A) · Activity 5943017
22 April 2016
Liferaft Servicing
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 5864696
19 April 2016
COI Inspection · Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5853386
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 16 August 2023
Resolved
A vessel must comply with the applicable requirements for any radio installations, including the requirements for installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with § 80.59 once every five years. If the ship passes the inspection, the technician will issue a Communications Act Safety Radiotelephony Certificate. Vessel Communications Act Safety Radiotelephony certificate expired 26 May 2022. 46CFR184.502, 47CFR80.903
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2023
Resolved 29 August 2023
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 6 July 2022
Resolved
06 Orange smoke flares expired
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 August 2022
Resolved 6 July 2024
Resolution: Rectified
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 10 June 2021
Resolved
Every vessel must be fitted with a suitable magnetic compass. Vessel's compass illumination not working. Vessel restricted to daytime operations until corrected.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2021
Resolved 30 September 2021
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 June 2021
Resolved
Label all new life rings with vessel name.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 June 2021
Resolution: Life rings labeled w/ vsl name.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificate for medical first aid
Issued 2 June 2021
Resolved
Provide proof of CPR / First Aid.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 June 2021
Resolution: Observed CPR/First Aid cards.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Resources and personnel
Issued 2 June 2021
Resolved
Conduct drills with CG Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 June 2021
Resolution: Man overboard, abandon ship, & E/R fire drills sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 June 2021
Resolved
Prove proper operation of engines.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 June 2021
Resolution: Witnessed sat operation of MDEs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 June 2021
Resolved
Prove porper operation of engine driven bilge pump.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 June 2021
Resolution: Witnessed sat op of engine driven bilge pump pumping lazarette space.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 2 June 2021
Resolved
Complete COI Inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 June 2021
Resolution: COI completed.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 26 August 2020
Resolved
Hydro for IBA is expired, renew hydro.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 September 2020
Resolution: Hydro renewed
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 26 August 2020
Resolved
IBA was not hooked up properly. Sea painter not connected. Ensure sea painter connected properly.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 September 2020
Resolution: IBA installed properly
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 26 August 2020
Resolved
Hydro for EPIRB expired. Vessel restricted to 03 NM from shore or make EPIRB float free.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2020
Resolved 24 September 2020
Resolution: Hydro renewed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 August 2020
Resolved
Bilge pump (PTO) inoperable. Repair. Vessel has required electric bilge pumps and hand pump.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2020
Resolved 10 June 2021
Resolution: Witnessed sat op of engine driven bilge pump pumping lazarette space.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 August 2020
Resolved
Renew ring life buoy.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2020
Resolved 24 September 2020
Resolution: Life ring renewed.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 26 August 2020
Resolved
Ensure first aid kit is up-to-date.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2020
Resolved 10 June 2021
Resolution: Observed sat first aid kit.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 7 August 2019
Resolved
Provide portable lights at operating station and at access to engine room.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 September 2019
Resolved 23 September 2019
Resolution: Cleared def.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 12 September 2018
Resolved
Battery for EPIRB is expired. Vsl restricted to no more than 03 NM from shore until battery is renewed.
Action required: 705 - Other - as specified
Due 12 October 2018
Resolved 19 September 2018
Navigation › Piloting/Steering › US Coast Pilot
Issued 7 June 2017
Resolved
Provide all required 2017 navigation publications and charts; required to have Coast Pilot [name withheld], Tidal Current Tables, Rules of the Road, and applicable charts. 46 CFR 184.420
Action required: 705 - Other - as specified
Due 14 June 2017
Resolved 21 June 2017
Resolution: Coast Pilot [name withheld], Tidal Current Tables, Rules of the Road, and applicable charts were provided.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 2 June 2017
Resolved
Provide Employee Assistance Program training and education placards in accomodation space. 46 CFR 16.401
Action required: 705 - Other - as specified
Due 14 June 2017
Resolved 21 June 2017
Resolution: Employee Assistance Program for employees was provided.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 2 June 2017
Resolved
Provide 6 additional lifejackets with proper retro reflective tape. Passenger count reduced to 26. 46 CFR 180.75
Action required: 705 - Other - as specified
Due 14 June 2017
Resolved 21 June 2017
Resolution: 6 New lifejacket were provided.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 20 April 2016
Resolved
Replace port cutlass bearing
Action required: 705 - Other - as specified
Due 19 May 2016
Resolved 13 May 2016
Resolution: replaced bearing
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 20 April 2016
Resolved
Repair or replace starboard exaust muffler connection
Action required: 705 - Other - as specified
Due 19 May 2016
Resolved 31 May 2016
Resolution: Proper repair was made to STBD muffler
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 20 April 2016
Resolved
Repair roof drain in pilothouse.
Action required: 705 - Other - as specified
Due 30 April 2017
Resolved 29 March 2017
Resolution: Fiberglass roof was properly repaired in the pilot house.
Electrical › Electrical Distribution System (service) › Wiring
Issued 20 April 2016
Resolved
Replace wire chase cover in pilothouse.
Action required: 705 - Other - as specified
Due 19 May 2016
Resolved 31 May 2016
Resolution: Wire chase cover was replace