MAURY USCG vessel records Sign in
← All vessels

MR JOSEPH

MR JOSEPH is a 1998 offshore supply vessel. The Coast Guard has recorded 27 inspections since 1998, most recently in June 2017, along with 28 deficiencies.

Records from 1998 to 2017. Most recent: inspection, 13 June 2017.

Built
1998
Last inspected
13 June 2017
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8964264 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WCY8734
487482
Flag
MALTA
366993170 (licence lapsed)
Maury page id
psix-487482

Inspections, by type

…with no type recorded6
Years with a record 9 calendar years (1998–2017)
The 27 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it289 - Dead Weight, Ton
97 - Regulatory (Subpart C or D), Gross Ton
289 - Convention (Subpart B), Gross Ton
66 - Regulatory (Subpart C or D), Net Ton
86 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WCY8734MMSI 366993170 · expired · voluntarily equipped · granted 21 January 2009, cancelled 6 April 2019
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 27

13 June 2017 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6175030
4 December 2008 Examination of Repairs · MTSA Verification · Annual Inspection · Damage Survey · Hull Examination · Ballast Water Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3377532
28 May 2008 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3220246
27 April 2008 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3212130
18 December 2007 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3149338
10 October 2007 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3077144
9 October 2007 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3076781
3 October 2006 COI Inspection · Ballast Water Examination · MTSA Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2792469
9 November 2005 Examination of Repairs · Internal Structural Exam · Hull Examination · MTSA Verification · COI Inspection · Ballast Water Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2531416
8 April 2005 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2329506
24 March 2005 In-Service Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2319002
4 March 2005 MTSA Verification · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2307357
22 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1973266
3 December 2003 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1958119
25 February 2003 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1749179
11 December 2001 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1417425
25 May 2001 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1063621
23 May 2001 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1064496
21 May 2001 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1063424
25 January 2001 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1057148
11 August 2000 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 823733
6 June 2000 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 819418
11 May 2000 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 818071
11 April 2000 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1048662
8 March 2000 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1458723
24 February 2000 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1046867
31 December 1998 Inclining Experiment · Initial Construction-Excluding Oversight · Hull Examination · Initial Certification
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1375878

Deficiency record · 28

Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 18 December 2007 Resolved
Provide emergency source of power IAW 46 CFR 131.52(c) and 46 CFR 112.05-5(a).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 December 2007
Resolution: Corrected power distribution panel.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 24 March 2005 Resolved
Vessel to be in compliance with requirements of stability letter, cargo max deck height, prior to departure from dock.
Action required: 17 - Rectify deficiencies prior to departure
Due 24 March 2005
Resolved 24 March 2005
Engineering › Diesel Engine (propulsion-reduction gear) › Gear, Timing
Issued 3 December 2003 Resolved
Provide shaft tachs for propulsion engines per 46 CFR 113.40.
Action required: 705 - Other - as specified
Due 3 January 2004
Resolved 4 March 2005
Resolution: Provided
Fire Fighting › Miscellaneous Items › B Class Division Penetrations
Issued 3 December 2003 Resolved
Provide general alarm bell in machinery space.
Action required: 705 - Other - as specified
Due 3 January 2004
Resolved 4 March 2005
Resolution: Provided
Lifesaving › Line-Throwing Appliances › Lines
Issued 3 December 2003 Resolved
Provide proper aux. line for line throwing gun per 46 CFR 133.170.
Action required: 705 - Other - as specified
Due 3 January 2004
Resolved 4 March 2005
Resolution: Provided
Engineering › Bilge Water Management System › Strainer
Issued 25 February 2003 Resolved
Provide mud basket strainer at bilge pump suction inlet as per 46 CFR 56.50-50 (g). to be completed at annual drydock. LEGACY COMPONENT DESC: Strainer
Action required: 705 - Other - as specified
Due 7 December 2003
Resolved 4 March 2005
Resolution: Provided
Navigation › Piloting/Steering
Issued 11 December 2001 Resolved
Steering failure alarm inop.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 December 2001
Resolution: Repaired same.
Engineering
Issued 25 January 2001 Resolved
VESSEL TO COMPLY W/ MSC LETTER DATED 29 DEC 2000, SERIAL E1-0003661 NLT 01MAR 2001.
Condition: Unknown
Due 25 January 2001
Resolved 25 January 2001
Documentation
Issued 31 December 1998 Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 31 January 1999
Resolved 16 August 1999
Documentation
Issued 31 December 1998 Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 31 January 1999
Resolved 16 August 1999
Documentation
Issued 31 December 1998 Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 31 January 1999
Resolved 16 August 1999
Documentation
Issued 31 December 1998 Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 31 January 1999
Resolved 16 August 1999
Documentation
Issued 31 December 1998 Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 31 January 1999
Resolved 16 August 1999
Documentation
Issued 31 December 1998 Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 16 August 1999
Resolved 16 August 1999
Documentation
Issued 31 December 1998 Resolved
46 CFR 54.01-5(e) - VESSEL TO PROVIDE UPV DRAWING.
Condition: Unknown
Due 16 August 1999
Resolved 16 August 1999
Documentation
Issued 31 December 1998 Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 31 January 1999
Resolved 16 August 1999
Engineering
Issued 31 December 1998 Resolved
46 CFR 56.50-60(K) - INSTALL DRIP PANS UNDER EACH FUEL OIL FILTER.
Condition: Unknown
Due 31 January 1999
Resolved 16 August 1999
Engineering
Issued 31 December 1998 Resolved
46 CFR 129.540(B) - DEMONSTRATE OPERATION OF REMOTE START/STOP FOR BOW THRUSTER SYTEM.
Condition: Unknown
Due 31 January 1999
Resolved 16 August 1999
Documentation
Issued 31 December 1998 Resolved
46 CFR 54.10-25(c) - VESSEL TO PROVIDE ASME U1A SHEET FOR EACH UPV.
Condition: Unknown
Due 16 August 1999
Resolved 16 August 1999
Documentation
Issued 31 December 1998 Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 31 January 1999
Resolved 16 August 1999
Documentation
Issued 31 December 1998 Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 31 January 1999
Resolved 16 August 1999
Documentation
Issued 31 December 1998 Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 31 January 1999
Resolved 16 August 1999
Documentation
Issued 31 December 1998 Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 31 January 1999
Resolved 16 August 1999
Documentation
Issued 31 December 1998 Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 31 January 1999
Resolved 16 August 1999
Documentation
Issued 31 December 1998 Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 31 January 1999
Resolved 16 August 1999
Documentation
Issued 31 December 1998 Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 31 January 1999
Resolved 16 August 1999
Lifesaving
Issued 31 December 1998 Resolved
46 CFR 127.240(K) - PROVIDE VERTICAL ACCESS TO UPPER WEATHER DECK WITH PERMANENTLY INCLINED LADDER.
Condition: Unknown
Due 31 December 1998
Resolved 31 December 1998
Documentation
Issued 31 December 1998 Resolved
46 CFR 127.110(a)(4) - VESSEL TO SUBMIT PLANS TO G-MSC AND RESOLVE ALL OUTSTANDING COMMENTS FOR THE PROPULSION AND PROPULSION-CONTROL SYSTEMS.
Condition: Unknown
Due 16 August 1999
Resolved 16 August 1999

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.