Records from 2016 to 2025. Most recent: inspection, 25 September 2025.
Documentation record
Registered dimensions (L × B × D)36.0 ft × 13.0 ft × 5.0 ft
Registered tonnagegross 15 / net 12
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderUNIVERSAL SHIPBUILDING · NEW IBERIA, LA, UNITED STATES · built 1988
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portKEY WEST, FL
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it19723 - Displacement, Ton
15 - Simplified, Gross Ton
12 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 17
25 September 2025
Deficiency Check · COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8239558
20 February 2025
Administrative Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8082155
25 April 2024
Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7901536
16 May 2023
Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7689486
2 March 2023
Drydock Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7635223
2 June 2022
Annual Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7466861
30 March 2021
COI Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7160553
5 March 2021
Hull Examination · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7151143
2 July 2020
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6993799
20 June 2019
Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6719905
25 February 2019
Administrative Inspection · Hull Examination · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6631722
9 May 2018
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6410464
16 August 2017
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6242987
27 June 2017
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6189359
23 February 2017
Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6093671
18 May 2016
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5880714
4 February 2016
Administrative Inspection · COI Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5809470
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 25 September 2025
Resolved
Conduct and document crew training as to the duties that the crew member is expected to perform in an emergency.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 October 2025
Resolved 26 September 2025
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 25 September 2025
Resolved
Provide an updated list of all employees enrolled in a random chemical testing program.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 October 2025
Resolved 26 September 2025
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 25 September 2025
Resolved
Install a float-free link of the appropriate size securing the life float's painter to the vessel prior to operating beyond 3 miles from shore.
Action required: 705 - Other - as specified
Resolved 26 September 2025
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 8 July 2020
Resolved
Life Float pianter line was found to be deteriorated and falling apart. Vessel is to replace life float painter line.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 July 2020
Resolved 10 July 2020
Resolution: Vessel submitted satisfactory evidence of deficiency correction. Vessel replaced life float painter line.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 8 July 2020
Resolved
Fire extinguisher was found to be past its 6yr internal service IAW NFPA 10 requirements. Service or replace extinguisher.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 July 2020
Resolved 10 July 2020
Resolution: Vessel submitted satisfactory evidence of deficiency correction. Vessel replaced expired fire extinguisher.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 8 July 2020
Resolved
Vessel did not have updated charts on hand. Vessel is required to update charts or purchase new updated charts.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2020
Resolved 30 March 2021
Resolution: New charts were provided.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 8 July 2019
Resolved
Grab line on life float cut halfway through. Replace or repair IAW manufacturer's recommendation.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2019
Resolved 30 July 2019
Resolution: Repaired grab line via splicing. Repair proposal was approved by manufacturer
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 June 2019
Resolved
Retro tape on 02 adult life jackets completely worn. Replace retro tape.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2019
Resolved 8 July 2019
Resolution: Replaced worn retro tape.
Engineering › Bilge Water Management System › Pump
Issued 10 July 2017
Resolved
Need seperate lights for each space with high water alarms located at operating station IAW 46cfr182.530
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 October 2017
Resolved 16 August 2017
Resolution: Installed lights for each compartment and checked.
Communications › Radio Communications › VHF Radiotelephone
Issued 10 July 2017
Resolved
Log radio checks before you get underway each day, IAW 47cfr80 and 46cfr184.502
Condition: Invalid
Action required: 705 - Other - as specified
Due 10 August 2017
Resolved 16 August 2017
Resolution: Log was checked and performed.
Documentation › Logs/Records › Drug Test Records
Issued 10 July 2017
Resolved
Provide current DAPI letter stating each crew member is on the owner/vessel consortium plan, IAW 46cfr16.210
Condition: Invalid
Action required: 705 - Other - as specified
Due 10 August 2017
Resolved 16 August 2017
Resolution: DAPI letter provided and updated.
Communications › Radio Communications › VHF Radiotelephone
Issued 10 July 2017
Resolved
Hook GPS up to VHF for proper use og DSC, IAW 46cfr80.905
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 August 2017
Resolved 16 August 2017
Resolution: GPS was uploaded in radio and checked.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 10 July 2017
Resolved
Install anchor light so it can be seen all around (360 degrees) IAW NavRules 23
Action required: 705 - Other - as specified
Due 10 August 2017
Resolved 16 August 2017
Resolution: New light installed and verified.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 11 April 2016
Resolved
No record of required EAP training provided. Provide proof of completion of required EAP training.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 April 2016
Resolved 18 May 2016
Resolution: Provided proof that training was completed.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 11 April 2016
Resolved
Kapok style lifejacket condemned leaving vessel short 01 adult lifejacket. Passenger count reduced to 14 until proof provided of appropriate number of lifejackets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 April 2016
Resolved 18 May 2016
Resolution: New life jacket was purchased and labeled.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 11 April 2016
Resolved
Waterlight battery expired for lifefloat. Replace battery. Restricted to daylight operations only.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 April 2016
Resolved 18 May 2016
Resolution: Life float light battery was changed out and working.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 11 April 2016
Resolved
Waterlight battery expired for ring buoy. Replace battery. Restricted to daylight operations only.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 April 2016
Resolved 18 May 2016
Resolution: Life bouy light battery was replaced and working.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 11 April 2016
Resolved
Emergency Exit not labeled on outside of exit. Label exit "Emergency Exit, Keep Clear."
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 April 2016
Resolved 18 May 2016
Resolution: Outside escape hatch was labeled.