Records from 2001 to 2025. Most recent: inspection, 25 September 2025.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 35
25 September 2025
Deficiency Check · COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8239558
20 February 2025
Administrative Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8082155
25 April 2024
Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7901536
16 May 2023
Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7689486
2 March 2023
Drydock Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7635223
2 June 2022
Annual Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7466861
30 March 2021
COI Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7160553
5 March 2021
Hull Examination · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7151143
2 July 2020
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6993799
20 June 2019
Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6719905
25 February 2019
Administrative Inspection · Hull Examination · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6631722
9 May 2018
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6410464
16 August 2017
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6242987
27 June 2017
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6189359
23 February 2017
Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6093671
18 May 2016
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5880714
4 February 2016
Administrative Inspection · COI Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5809470
29 July 2015
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5199680
23 July 2012
Deficiency Check · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4387662
13 September 2010
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3848898
26 March 2009
Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3440453
29 August 2008
Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3304251
10 September 2007
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3054238
23 April 2007
Deficiency Check · Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2904187
2 May 2006
Deficiency Check · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2638445
19 August 2005
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2468230
8 August 2005
Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2439632
1 March 2005
Deficiency Check · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2301698
18 May 2004
Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2071610
11 June 2003
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1815068
16 May 2003
Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1796872
10 March 2003
Hull Examination · Internal Structural Exam
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1754067
9 May 2002
Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1605226
24 May 2001
Initial Certification · Plan Review "T" Boat · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1417287
17 May 2001
Simplified Stability Test
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1597301
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 25 September 2025
Resolved
Conduct and document crew training as to the duties that the crew member is expected to perform in an emergency.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 October 2025
Resolved 26 September 2025
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 25 September 2025
Resolved
Provide an updated list of all employees enrolled in a random chemical testing program.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 October 2025
Resolved 26 September 2025
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 25 September 2025
Resolved
Install a float-free link of the appropriate size securing the life float's painter to the vessel prior to operating beyond 3 miles from shore.
Action required: 705 - Other - as specified
Resolved 26 September 2025
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 8 July 2020
Resolved
Life Float pianter line was found to be deteriorated and falling apart. Vessel is to replace life float painter line.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 July 2020
Resolved 10 July 2020
Resolution: Vessel submitted satisfactory evidence of deficiency correction. Vessel replaced life float painter line.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 8 July 2020
Resolved
Fire extinguisher was found to be past its 6yr internal service IAW NFPA 10 requirements. Service or replace extinguisher.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 July 2020
Resolved 10 July 2020
Resolution: Vessel submitted satisfactory evidence of deficiency correction. Vessel replaced expired fire extinguisher.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 8 July 2020
Resolved
Vessel did not have updated charts on hand. Vessel is required to update charts or purchase new updated charts.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2020
Resolved 30 March 2021
Resolution: New charts were provided.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 8 July 2019
Resolved
Grab line on life float cut halfway through. Replace or repair IAW manufacturer's recommendation.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2019
Resolved 30 July 2019
Resolution: Repaired grab line via splicing. Repair proposal was approved by manufacturer
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 June 2019
Resolved
Retro tape on 02 adult life jackets completely worn. Replace retro tape.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2019
Resolved 8 July 2019
Resolution: Replaced worn retro tape.
Engineering › Bilge Water Management System › Pump
Issued 10 July 2017
Resolved
Need seperate lights for each space with high water alarms located at operating station IAW 46cfr182.530
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 October 2017
Resolved 16 August 2017
Resolution: Installed lights for each compartment and checked.
Communications › Radio Communications › VHF Radiotelephone
Issued 10 July 2017
Resolved
Log radio checks before you get underway each day, IAW 47cfr80 and 46cfr184.502
Condition: Invalid
Action required: 705 - Other - as specified
Due 10 August 2017
Resolved 16 August 2017
Resolution: Log was checked and performed.
Documentation › Logs/Records › Drug Test Records
Issued 10 July 2017
Resolved
Provide current DAPI letter stating each crew member is on the owner/vessel consortium plan, IAW 46cfr16.210
Condition: Invalid
Action required: 705 - Other - as specified
Due 10 August 2017
Resolved 16 August 2017
Resolution: DAPI letter provided and updated.
Communications › Radio Communications › VHF Radiotelephone
Issued 10 July 2017
Resolved
Hook GPS up to VHF for proper use og DSC, IAW 46cfr80.905
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 August 2017
Resolved 16 August 2017
Resolution: GPS was uploaded in radio and checked.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 10 July 2017
Resolved
Install anchor light so it can be seen all around (360 degrees) IAW NavRules 23
Action required: 705 - Other - as specified
Due 10 August 2017
Resolved 16 August 2017
Resolution: New light installed and verified.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 11 April 2016
Resolved
No record of required EAP training provided. Provide proof of completion of required EAP training.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 April 2016
Resolved 18 May 2016
Resolution: Provided proof that training was completed.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 11 April 2016
Resolved
Kapok style lifejacket condemned leaving vessel short 01 adult lifejacket. Passenger count reduced to 14 until proof provided of appropriate number of lifejackets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 April 2016
Resolved 18 May 2016
Resolution: New life jacket was purchased and labeled.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 11 April 2016
Resolved
Waterlight battery expired for lifefloat. Replace battery. Restricted to daylight operations only.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 April 2016
Resolved 18 May 2016
Resolution: Life float light battery was changed out and working.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 11 April 2016
Resolved
Waterlight battery expired for ring buoy. Replace battery. Restricted to daylight operations only.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 April 2016
Resolved 18 May 2016
Resolution: Life bouy light battery was replaced and working.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 11 April 2016
Resolved
Emergency Exit not labeled on outside of exit. Label exit "Emergency Exit, Keep Clear."
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 April 2016
Resolved 18 May 2016
Resolution: Outside escape hatch was labeled.
Electrical › Electric Generation Source (service) › Overcurrent Device
Issued 23 July 2012
Resolved
Prove generator is derated to 80% as per 46 CFR 183.320
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 23 August 2012
Resolved 20 August 2012
Resolution: Provided documentation that the generator is de-rated with a 30amp breaker.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 23 April 2007
Resolved
Provide and install gaskets on hatches as required by 46 CFR 179.360
Action required: 705 - Other - as specified
Due 23 May 2007
Resolved 2 July 2007
Resolution: Provided gaskets on hatches.
Engineering › Steering Gear System › Rudder
Issued 23 April 2007
Resolved
Properly install rudders and make ready for inspection as required by 46 CFR 176.610
Action required: 705 - Other - as specified
Due 23 May 2007
Resolved 2 July 2007
Resolution: Properly installed rudders.
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 23 April 2007
Resolved
Properly install the propellers and make ready for inspection as required by 46 CFR 176.610
Action required: 705 - Other - as specified
Due 23 May 2007
Resolved 2 July 2007
Resolution: Properly installed propellers.
Engineering › Bilge Water Management System › Valve
Issued 23 April 2007
Resolved
Prove operation of bilge overboard discharge valve in lazarette as required by 46 CFR 182.520
Action required: 705 - Other - as specified
Due 23 May 2007
Resolved 2 July 2007
Resolution: Proved operation of bilge overboard discharge valve.
Engineering › Sea-water System (primary cooling) › Valve
Issued 23 April 2007
Resolved
Prove operation of 1 1/2 in gate valve as required by 46 CFR 176.610
Action required: 705 - Other - as specified
Due 23 May 2007
Resolved 2 July 2007
Resolution: Proved operation of 1 1/2 in gate valve.
Engineering › Sea-water System (primary cooling) › Sea Chest
Issued 23 April 2007
Resolved
Clean all sea strainers and make ready for inspection as required by 46 CFR 176.610
Action required: 705 - Other - as specified
Due 23 May 2007
Resolved 2 July 2007
Resolution: Cleaned sea strainers.
Construction/Loadline › Penetrations › Valve Flange
Issued 23 April 2007
Resolved
Replace stripped out through hull fitting on portside of engine room as required by 46 CFR 176.800
Action required: 705 - Other - as specified
Due 23 May 2007
Resolved 2 July 2007
Resolution: Replaced through hull fittings.
Operations/Management › Drills/Instruction › Fire
Issued 2 May 2006
Resolved
Perform drills to the satisfaction of the attending marine inspector in accordance with 46 CFR 185.520.
Action required: 705 - Other - as specified
Due 2 June 2006
Resolved 21 June 2006
Resolution: Performed drills to the satisfaction of the attending marine inspector in accordance with 46 CFR 185.520.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 2 May 2006
Resolved
Provide tidal currents publication in accordance with 46 CFR 184.420.
Action required: 705 - Other - as specified
Due 2 May 2006
Resolved 21 June 2006
Resolution: Provided tidal currents publication in accordance with 46 CFR 184.420.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 2 May 2006
Resolved
Prove proper operation of anchor light in accordance with 46 CFR 183.420.
Action required: 705 - Other - as specified
Due 2 May 2006
Resolved 21 June 2006
Resolution: Proved proper operation of anchor light in accordance with 46 CFR 183.420.
Operations/Management › Passenger Operations › Safety Orientation
Issued 2 May 2006
Resolved
Properly mark upperdeck with the amount of passengers allowed in accordance with 46 CFR 185.602.
Action required: 705 - Other - as specified
Due 2 May 2006
Resolved 21 June 2006
Resolution: Properly marked upperdeck with the amount of passengers allowed in accordance with 46 CFR 185.602.
Lifesaving › Lifefloat › Retroreflective Material
Issued 2 May 2006
Resolved
Provide retro reflective tape on the lifefloat and lifejackets where needed in accordance with 46 CFR 180.200.
Action required: 705 - Other - as specified
Due 2 May 2006
Resolved 21 June 2006
Resolution: Provided retro reflective tape on the lifefloat and lifejackets where needed in accordance with 46 CFR 180.200.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 2 May 2006
Resolved
Properly mount B:C 1 fire extinguisher at the operating station in accordance with 46 CFR 181.500.
Action required: 705 - Other - as specified
Due 2 May 2006
Resolved 21 June 2006
Resolution: Properly mounted B:C 1 fire extinguisher at the operating station in accordance with 46 CFR 181.500.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 2 May 2006
Resolved
Prove that fire extinguishers have been serviced in accordance with 46 CFR 176.810.
Action required: 705 - Other - as specified
Due 2 May 2006
Resolved 21 June 2006
Resolution: Proved that fire extinguishers have been serviced in accordance with 46 CFR 176.810.
Documentation › Certificates/Documents › FCC SSL
Issued 2 May 2006
Resolved
Provide a valid FCC Safety Certificate in accordance with 47 CFR.
Action required: 705 - Other - as specified
Due 2 May 2006
Resolved 21 June 2006
Resolution: Provided a valid FCC Safety Certificate in accordance with 47 CFR.
Engineering › Steering Gear System › Bracket/Clamp
Issued 2 May 2006
Resolved
Double clamp all vital systems piping and shaft logs in accordance with 46 CFR 182.710.
Action required: 705 - Other - as specified
Due 2 May 2006
Resolved 21 June 2006
Resolution: Double clamped all vital systems piping and shaft logs in accordance with 46 CFR 182.710.
Engineering › Fuel Oil Service System › Hose
Issued 2 May 2006
Resolved
Properly support fuel hose to port engine in accordance with 46 CFR 182.720.
Action required: 705 - Other - as specified
Due 2 May 2006
Resolved 21 June 2006
Resolution: Properly supported fuel hose to port engine in accordance with 46 CFR 182.720.
Personnel › Certificates/Documents/Licenses › Certificate, CPR Course Completion
Issued 8 August 2005
Resolved
Provide for review valid CPR cards for 50% of the crew as required by NVIC 1-91
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 September 2005
Resolved 19 August 2005
Resolution: Valid cards provided
Operations/Management › Passenger Operations › Safety Orientation
Issued 8 August 2005
Resolved
Mark upper deck with "No Passengers" as required by 46 CFR 185.602
Action required: 705 - Other - as specified
Due 8 September 2005
Resolved 19 August 2005
Resolution: Upper deck labeled.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 8 August 2005
Resolved
Renew expired eyewash and aspirin to first aid kit as required by 46 CFR 184.710
Action required: 705 - Other - as specified
Due 8 September 2005
Resolved 19 August 2005
Resolution: Items replaced
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 8 August 2005
Resolved
Install guard over rotating belt on starboard engine as required by 46 CFR 177.960
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 September 2005
Resolved 19 August 2005
Resolution: Guard reinstalled
Electrical › Electric Generation Source (service) › Generator
Issued 8 August 2005
Resolved
Repair or renew alternator on starboard engine and prove proper operation as required by 46 CFR 176.804
Action required: 705 - Other - as specified
Due 29 August 2005
Resolved 21 November 2005
Resolution: New alternator installed and proven operational.
Lifesaving › Lifefloat › Paddle
Issued 1 June 2004
Resolved
Mark vessel's name on life float paddles IAW 46 CFR 185.604(g).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 July 2004
Resolved 1 June 2004
Resolution: Name written on paddles.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 1 June 2004
Resolved
Provide water light on ring life buoy IAW 46 CFR 181.30.
Action required: 705 - Other - as specified
Due 1 July 2004
Resolved 1 June 2004
Resolution: Provided waterlight for ring life buoy.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 1 June 2004
Resolved
Vessel name not on ring life buoy IAW 46 CFR 185.604.
Action required: 705 - Other - as specified
Due 1 July 2004
Resolved 1 June 2004
Resolution: Name written on ring life buoy.
Personnel › Certificates/Documents/Licenses › Certificate, CPR Course Completion
Issued 1 June 2004
Resolved
CPR card not provided IAW NVIC 1-91.
Action required: 705 - Other - as specified
Due 1 July 2004
Resolved 8 September 2004
Resolution: provided CPR card
Communications › Alarms/Indicators › Bilge Alarm
Issued 1 June 2004
Resolved
High water bilge alarm has no visual indicator IAW 46 CFR 182.530.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 June 2004
Resolved 1 June 2004
Resolution: Provided ligth for high water bilge alarm.
Navigation › Collision/Grounding Avoidance › Navigation Bridge Visibility
Issued 1 June 2004
Resolved
Repair cracked window in pilothouse IAW 46 CFR 177.10.
Action required: 705 - Other - as specified
Due 1 July 2004
Resolved 12 July 2004
Resolution: Recieved faxed copy of repair receipt.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 1 June 2004
Resolved
Stern and anchor lights inoperable, not IAW 46 CFR 183.420.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 July 2004
Resolved 18 March 2005
Resolution: Lights were operable
Personnel › Certificates/Documents/Licenses
Issued 16 May 2003
Resolved
Provide first-aid/CPR cards for 50% of crew as required by NVIC 1-91. LEGACY COMPONENT DESC: Certificate, CPR Course Completion
Due 16 June 2003
Resolved 11 June 2003
Resolution: CPR card provided.
Navigation › Piloting/Steering
Issued 16 May 2003
Resolved
Provide updated tidal current tables as required by 46 CFR 184.420. LEGACY COMPONENT DESC: Tide/Tidal Current Tables
Due 16 June 2003
Resolved 11 June 2003
Resolution: Updated currrent tables provided.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 16 May 2003
Resolved
Repair/replace stern light as required by 46 CFR 72COLREGS
Due 16 May 2003
Resolved 16 May 2003
Resolution: Repaired during inspection.