VAGABOND

VAGABOND is a 1998 passenger vessel (inspected). The Coast Guard has recorded 42 inspections since 1999, most recently in June 2025, along with 42 deficiencies and 3 casualty investigations between 2005 and 2010.

Records from 1999 to 2025. Most recent: inspection, 2 June 2025.

Built
1998
Last inspected
2 June 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCZ8394
487540
Flag
UNITED STATES
—
Maury page id
psix-487540

Inspections, by type

…with no type recorded8
Years with a record 24 calendar years (1999–2025)
The 42 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)44.0 ft × 15.0 ft × 4.0 ft
Registered tonnagegross 17 / net 14
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMDI BOATWORKS INC · SOUTHWEST HARBOR, ME, UNITED STATES · built 1998
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portCHERRYFIELD, ME
Trade endorsementsCoastwise, unrestricted, Fishery, Registry
DocumentationValid · issued 19 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it17 - Simplified, Gross Ton
14 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 42

2 June 2025 DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8105067
11 April 2025 Hull Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8109636
2 July 2024 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7944297
5 February 2024 Administrative Inspection
Administrative · USCG Northeast District (dp) · USCG Northeast District (CGD-NE) · Activity 7860582
31 October 2023 Administrative Inspection
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7817890
6 April 2023 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7664687
31 May 2022 Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7453519
17 May 2021 Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7193671
6 April 2021 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7168698
14 May 2020 COI Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6953434
30 April 2019 Annual Inspection · Drydock Exam
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6672547
14 May 2018 Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6408419
28 April 2017 DAPI Audit · Deficiency Check · Annual Inspection · Hull Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6134370
20 May 2016 Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 5881760
5 February 2016 Examination of Repairs · Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 5810117
6 October 2014 Type not recorded
No type recorded · USCGC CAMPBELL (WMEC 909) · Activity 5002316
12 May 2014 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 4856949
15 May 2012 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 4313167
17 February 2011 Type not recorded
No type recorded · USCGC JEFFERSON ISLAND (WPB 1340) · USCG Northeast District (CGD-NE) · Activity 3949555
11 December 2009 Damage Survey
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 3648728
9 December 2009 Type not recorded
No type recorded · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 3647927
12 May 2009 Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 3480186
19 February 2009 Drydock Exam
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 3458826
16 June 2008 Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 3238889
4 June 2008 Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 3234005
31 May 2007 Re-Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 2952235
15 March 2007 Hull Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 2888229
15 June 2006 Type not recorded
No type recorded · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 2708052
1 June 2006 Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 2663937
6 February 2006 Damage Survey
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 2580110
23 October 2005 Damage Survey
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 2520672
23 October 2005 Type not recorded
No type recorded · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 2527702
2 June 2005 COI Inspection
Physical examination · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 2386345
13 April 2005 Type not recorded
No type recorded · Station Southwest Harbor · USCG Northeast District (CGD-NE) · Activity 2333435
23 February 2005 Hull Examination
Physical examination · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 2308263
11 May 2004 Re-Inspection
Physical examination · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 2065848
21 May 2003 Re-Inspection
Physical examination · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 1798051
9 April 2003 Plan Review "T" Boat · Hull Examination
Physical examination · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 1771008
13 May 2002 Type not recorded
No type recorded · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 1616143
4 June 2001 Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1465035
20 June 2000 Inclining Experiment · Initial Certification · Hull Examination · Plan Review "T" Boat
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1443066
4 October 1999 Type not recorded
No type recorded · Station Southwest Harbor · USCG Northeast District (CGD-NE) · Activity 1506512

Deficiency record · 42

01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 2 July 2024 Resolved
Any vessel of at least five net tons which engages in the fisheries on the navigable waters of the United States or in the Exclusive Economic Zone, or coastwise trade, unless exempt under § 67.9(c), must have a Certificate of Documentation bearing a valid endorsement appropriate for the activity in which engaged. Vessel only had fisheries endorsement on COD during time of inspection. 46 CFR 67.7
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 July 2024
Resolved 3 July 2024
Resolution: Vessel sent updated COD with Coastwise endorsement.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 July 2024 Resolved
An adult lifejacket must be provided for each person carried on board a vessel. 10 of the 42 life jackets are not in serviceable condition leaving the vessel with 32 at the time of inspection. passenger count is reduced to 32 until documentation provided for the 10 new lifejackets. 46 CFR 180.71
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 July 2024
Resolved 3 July 2024
Resolution: Vessel POC sent pictures of the 10 new lifejackets placed onboard.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 31 October 2023 Resolved
Vessel did not complete the required Coast Guard annual inspection The annual inspection must be completed prior to the vessel carrying passengers for hire.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 November 2023
Resolved 16 July 2024
Resolution: Annual Inspection completed along with Drills. All Sat.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 26 May 2020 Resolved
Prove operation of fwd masthead light.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 26 May 2020
Resolved 26 May 2020
Resolution: Replaced bulb and tested sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 May 2020 Resolved
Provide non-expired battery for ring-bouy float light.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 26 May 2020
Resolved 26 May 2020
Resolution: Battery replaced, light tested sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 May 2020 Resolved
Provide 01 type I PFD. Vessel is certified to carry 42 total persons. 41 PFD's were onboard at time of inspection.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 26 May 2020
Resolved 26 May 2020
Resolution: 01 PFD Provided.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 30 April 2019 Resolved
Provided stop valve at through hull fitting for sink discharge in forward head per 46 CFR 171.119(b).
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2019
Resolved 26 May 2020
Resolution: Installed valve.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 30 April 2019 Resolved
Prove operation of discharge valve for aft steering bilge discharge line.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2019
Resolved 26 May 2020
Resolution: Valve serviced and tested sat.
Engineering › Bilge Water Management System › Valve
Issued 14 May 2018 Resolved
Vessel is equipped with submersible bilge pumps (03). Overboard fittings are required to be fitted with valves. Install positive stop valves in through hull fittings.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 8 June 2018
Resolved 22 May 2018
Resolution: Installed ball valves.
Engineering › Sea-water System (primary cooling) › Piping
Issued 23 May 2017 Resolved
Replace the flexible hose nipple on the seavalve for the toilet system.
Action required: 705 - Other - as specified
Due 23 June 2017
Resolved 20 June 2017
Resolution: cleared
Operations/Management › Drug and Alcohol Testing › Testing, Substances
Issued 23 May 2017 Resolved
Provide approved alcohol test strips onboard vsl to meet the SMI testing requirments.
Action required: 705 - Other - as specified
Due 23 June 2017
Resolved 20 June 2017
Resolution: corrected
Fire Fighting › Fire Bucket › Quantity
Issued 23 May 2017 Resolved
Provide 03, 2-1/2 gallon fire buckets onboard vessel.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 23 June 2017
Resolved 20 June 2017
Resolution: corrected
Communications › Radio Communications › VHF Radiotelephone
Issued 20 May 2016 Resolved
Non DSC radio on vessel. Install proper radio DSC enabled radio.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 30 June 2016
Resolved 31 May 2016
Resolution: New radio installed and MMSI # assigned.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 15 May 2014 Resolved
Pre-engineered fire system for main engine compartment failed override functional test. Repairs of fire system and operational check required to satisfaction of CG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 May 2014
Resolution: Corrected on the spot. Service technician attended the vessel and replaced a malfunctioning relay in the main fire boy electrical panel. ERH
Fire Fighting › Combustible Materials › Draught Stops
Issued 15 May 2014 Resolved
Engine room forward bulkhead requires insulation/materials installed in bulkhead penetrations/gaps to prevent fixed fire system from escaping in event of a fire.
Action required: 705 - Other - as specified
Due 29 May 2014
Resolved 28 May 2014
Resolution: Witnessed insulation panel installed in penetrations/gaps of forward engine bulkhead. All satisfactory. ERH
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 15 May 2014 Resolved
Exhaust portion of the engine turbo to the water injection point requires insulation.
Action required: 705 - Other - as specified
Due 29 May 2014
Resolved 28 May 2014
Resolution: Witnessed exhaust lagging properly installed on engine turbo up to water injection point. All satisfactory. ERH
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 15 May 2014 Resolved
Alcohol swabs kept onboard are expired and require replacement.
Action required: 705 - Other - as specified
Due 29 May 2014
Resolved 15 May 2014
Resolution: Corrected on the spot. Witnessed newly purchased alcohol swabs installed onboard vessel. ERH
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 15 May 2012 Resolved
Provide proof of consortium enrollment for all employees.
Action required: 705 - Other - as specified
Due 16 June 2012
Resolved 22 June 2012
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 4 June 2008 Resolved
Provide COD with Coastwise endorsement.
Action required: 705 - Other - as specified
Due 30 June 2008
Resolved 29 July 2008
Resolution: Coastwise endorsement added 7/25/08.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 4 June 2008 Resolved
Provide alcohol testing equipment.
Action required: 705 - Other - as specified
Due 4 July 2008
Resolved 9 September 2008
Resolution: O/O provided invoive proving purchase of kits.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 4 June 2008 Resolved
Provide updated tide tables.
Action required: 705 - Other - as specified
Due 4 July 2008
Resolved 26 June 2008
Resolution: Tide Tables acquired from local marina.
Navigation › Piloting/Steering › US Coast Pilot
Issued 4 June 2008 Resolved
Provide updated Coast Pilot.
Action required: 705 - Other - as specified
Due 4 July 2008
Resolved 26 June 2008
Resolution: O/O provided receipt for purchase of Coast Pilot.
Navigation › Piloting/Steering › Magnetic Compass
Issued 4 June 2008 Resolved
Prove operation of compass light.
Action required: 705 - Other - as specified
Due 4 July 2008
Resolved 16 June 2008
Resolution: O/O provided receipt for purchase of new compass light.
Fire Fighting › Structural - B Class Divisions › Windows
Issued 4 June 2008 Resolved
Replace broken window in pilot house.
Action required: 705 - Other - as specified
Due 4 July 2008
Resolved 26 June 2008
Resolution: O/O submitted invoice for new window.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 4 June 2008 Resolved
Repair anchor light (prove operation).
Action required: 705 - Other - as specified
Due 4 July 2008
Resolved 16 June 2008
Resolution: O/O provided receipt for purchase of new light.
Operations/Management › Drills/Instruction › Not Conducted
Issued 4 June 2008 Resolved
Log testing of EPIRB Monthly.
Action required: 705 - Other - as specified
Due 4 July 2008
Resolved 26 June 2008
Resolution: Issued log which is now being used.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 4 June 2008 Resolved
Prove operation of fixed system shutdown and manual override restart.
Action required: 705 - Other - as specified
Due 15 June 2008
Resolved 10 June 2008
Resolution: O/O contacted office and advised that Kramp electronics had repaired fixed system. Invoice forthcoming.
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 31 May 2007 Resolved
SERVICE FIXED FIREFIGHTING SYSTEM, I B-1 AND 1 B-II.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 May 2007
Lifesaving › Lifefloat › Float-free Link
Issued 1 June 2006 Resolved
RIG LIFEFLOATS IAW 46CFR180.137
Action required: 705 - Other - as specified
Due 1 July 2006
Resolved 20 June 2006
Navigation › Collision/Grounding Avoidance › Day Shapes
Issued 1 June 2006 Resolved
PROVIDE ANCHORING DAY SHAPE
Action required: 705 - Other - as specified
Due 1 July 2006
Resolved 20 June 2006
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 1 June 2006 Resolved
PROVIDE ANNUAL SERVICE RECORD FOR PORTABLE FIRE EXTINGUISHERS IAW NFPA 10
Action required: 705 - Other - as specified
Due 1 July 2006
Resolved 13 June 2006
Resolution: FIRE EXTINGUISHERS SERVICED
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 1 June 2006 Resolved
PROVIDE RAIL COURSE THAT IS MISSING AT OPERATING STATION
Action required: 705 - Other - as specified
Due 1 July 2006
Resolved 13 June 2006
Resolution: NEW RAIL COURSE INSTALLED AT OPERATING STATION
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 1 June 2006 Resolved
PROVIDE NAVIGATION PUBLICATIONS IAW 46CFR184.420
Action required: 705 - Other - as specified
Due 1 July 2006
Resolved 20 June 2006
Construction/Loadline › Hull › Bottom Plating
Issued 23 October 2005 Resolved
Undergo damage survey to the satisfaction of an attending Coast Guard Marine Inspector prior to carrying more than six passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 February 2006
Resolution: Satisfactory damage survey conducted.
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 11 May 2004 Resolved
REPLACE ONE (01) B-I PORTABLE FIRE EXTINGUISHER (OVERDUE FOR 6YR SERVICING-NOT PRACTICAL). LEGACY COMPONENT DESC: Service
Action required: 705 - Other - as specified
Due 30 May 2004
Resolved 20 May 2004
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 11 May 2004 Resolved
CONDUCT ANNUAL SERVICE FOR PORTABLE FIRE EXTINGUISHERS. LEGACY COMPONENT DESC: Service
Action required: 705 - Other - as specified
Due 30 May 2004
Resolved 20 May 2004
Lifesaving › Buoyant Apparatus
Issued 11 May 2004 Resolved
PROVIDE SPACERS BETWEEN LIFEFLOATS.
Action required: 705 - Other - as specified
Due 30 May 2004
Resolved 20 May 2004
Lifesaving › Lifebuoys
Issued 11 May 2004 Resolved
PROVIDE SCREW-POST TYPE BATTERIES FOR ALL FLOATING WATERLIGHTS. LEGACY COMPONENT DESC: Self-igniting Lights
Action required: 705 - Other - as specified
Due 30 May 2004
Resolved 20 May 2004
Lifesaving › Lifebuoys
Issued 11 May 2004 Resolved
PROVIDE 3 FT LANYARD FOR RING LIFEBUOY WATERLIGHT. LEGACY COMPONENT DESC: Self-igniting Lights
Action required: 705 - Other - as specified
Due 30 May 2004
Resolved 20 May 2004
Fire Fighting › Ventilation Systems
Issued 11 May 2004 Resolved
PROVIDE CLOSURE DEVICE FOR ENGINE SPACE VENT (CABIN TOP). LEGACY COMPONENT DESC: Ducts
Action required: 705 - Other - as specified
Due 30 May 2004
Resolved 20 May 2004
Lifesaving
Issued 4 June 2001 Resolved
Provide log of lifesaving/firefighting equipment maintenance, crew training, and drills per 46 CFR 185.722, 176.810(b)(1), 185.420, 185.520, and 185.524
Condition: Unknown
Due 4 June 2001
Resolved 4 June 2001
Fire Fighting
Issued 4 June 2001 Resolved
Service fixed firefighting system and portable extinguishers per NFPA 10 and 46 CFR 176.810.
Condition: Unknown
Due 4 June 2001
Resolved 4 June 2001

Casualty record · 3

23 October 2005Routine · role: Involved in a Marine Casualty · activity 2527702
9 December 2009Routine · role: Involved in a Marine Casualty · activity 3647927
27 August 2010Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3840586
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.