BIG MOHAWK is a 1976 passenger vessel (inspected). The Coast Guard has recorded 78 inspections since 1985, most recently in March 2026, along with 96 deficiencies and 1 casualty investigation in 2022.
Records from 1985 to 2026. Most recent: inspection, 19 March 2026.
- Built
- 1976
- Last inspected
- 19 March 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 96 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2022
Identity
573757
WDG5826
48758
Flag
UNITED STATES
367550680
Maury page id
psix-48758
Inspections, by type
…with no type recorded3
Years with a record
38 calendar years (1985–2026)
The 78 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)61.3 ft × 19.8 ft × 5.3 ft
Registered tonnagegross 62 / net 42
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderLYDIA YACHTS INC · STUART, FL, UNITED STATES · built 1976
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portBELMAR, NJ
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 17 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it62 - Regulatory (Subpart C or D), Gross Ton
42 - Regulatory (Subpart C or D), Net Ton
42 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDN5972MMSI 367550680 · active · compulsorily equipped · granted 1 February 2023, expires 1 February 2033
WDG5826MMSI 367550680 · expired · compulsorily equipped · granted 19 October 2012, cancelled 24 December 2022
WCW9638MMSI 367151220 · expired · compulsorily equipped · granted 16 November 2006, cancelled 4 February 2017 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 78
19 March 2026
Annual Inspection · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8290405
15 April 2025
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8111905
25 February 2025
COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8082725
18 September 2024
Drydock Exam · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7979417
21 March 2024
Annual Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7881997
3 October 2023
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7802673
23 March 2023
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7617310
22 September 2022
Internal Structural Exam · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7530526
25 June 2022
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7488791
24 March 2022
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7393268
21 September 2021
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7282936
21 September 2021
Deficiency Check · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7383602
24 March 2021
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7160832
24 September 2020
Internal Structural Exam · Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7064029
17 March 2020
COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6925910
25 February 2019
DAPI Audit · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6631928
27 September 2018
Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6548347
20 March 2018
Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6372431
15 March 2017
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6105073
28 September 2016
Administrative Inspection · Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6029165
26 April 2016
Plan Review "T" Boat · Deficiency Check · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5862814
1 March 2016
Annual Inspection · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5824513
1 October 2014
Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4999864
6 May 2014
Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4865130
27 October 2010
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3878684
29 April 2009
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3463561
23 October 2008
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3349985
3 April 2008
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3176663
21 March 2007
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2892285
19 April 2006
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2627994
12 April 2005
COI Inspection · Deficiency Check
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2331504
3 November 2004
Internal Structural Exam · Hull Examination
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2230935
20 April 2004
Annual Inspection · MARPOL Annex V Examination
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2044642
10 April 2003
Annual Inspection · MARPOL Annex V Examination
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1769485
13 November 2002
Hull Examination · Internal Structural Exam
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1700809
18 March 2002
MARPOL Annex V Examination · Re-Inspection
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1494063
4 April 2001
MARPOL Annex V Examination · Re-Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1454958
10 May 2000
COI Inspection · MARPOL Annex V Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1376157
10 May 2000
Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1464244
22 June 1999
Administrative
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1454689
12 May 1999
Deficiency Check · Re-Inspection · MARPOL Annex V Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1453617
10 May 1999
Plan Review "T" Boat
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1129435
27 October 1998
Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 804380
12 May 1998
Re-Inspection · MARPOL Annex V Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 790877
7 May 1997
COI Inspection · MARPOL Annex V Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1105060
31 October 1996
Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1166449
15 October 1996
Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1430293
18 June 1996
MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1193686
30 April 1996
MARPOL Annex V Examination · Deficiency Check · Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1080391
16 May 1995
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 923254
28 April 1995
Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1179335
30 June 1994
Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1138069
5 May 1994
Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 858300
4 May 1994
MARPOL Annex V Examination · COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1168513
15 April 1994
Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1168083
14 July 1993
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1156393
14 June 1993
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 839150
30 April 1993
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 831948
27 April 1993
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 836263
27 April 1993
Administrative
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1143964
29 April 1992
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 953599
29 April 1991
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1214076
24 April 1991
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 934947
12 October 1990
Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 911389
14 September 1990
Drydock Extension
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 918291
24 July 1990
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1224398
27 April 1990
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1231094
27 April 1989
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 896431
10 March 1989
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 902200
3 January 1989
Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1346828
5 April 1988
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1197372
13 May 1987
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1023476
7 May 1987
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1335912
16 September 1986
Credit Drydock
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1311169
6 May 1986
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1296000
27 November 1985
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1307419
26 March 1985
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 980602
22 March 1985
Credit Drydock
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 980606
Deficiency record · 96
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 19 March 2026
Resolved
A space containing propulsion machinery must be equipped with a fire detection and alarm system of an approved type. The heat detection in the engine room had not been tested by third party and crew was not comfortable testing during inspection. Have certified or licensed state or local fire extinguishing agency test and certify heat detector prior to the carriage of passengers.
46 CFR 181.405(a)(1)
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 19 March 2026
Resolved
The number of penetrations in a watertight bulkhead must be minimized. A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable and made watertight. Crew has drilled several 1 inch holes to run wiring through several watertight bulkheads from crash compartment to engine compartment. Fill all holes to ensure watertight integrity of bulkheads prior to carriage of passengers.
46 CFR 179.320(c)
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 19 March 2026
Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with § 80.59 once every five years. Vessels safety telephony certificate is expired. Vessel is restricted to 1000 ft. from shore until renewed.
47 CFR 80.903
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 19 March 2026
Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. EPIRB hydrostatic release unit expires at the end of the month (13 days) Replace HRU prior to the carriage of passengers.
46 CFR 180.64
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 March 2026
Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, as indicated by the vessel's stability letter, the maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least 25 millimeters (1 inch) numbers and letters at the entranceway to that deck. Upper deck max pax accommodation is marked for 36 pax instead of 33 pax per stability letter and COI. Make change and mark accordingly.
46 CFR 185.602(g)
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 March 2026
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew. Vessel had incomplete kit with expired items. Provide new first aid kit to the satisfaction of MI.
46 CFR 184.710
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 19 March 2026
Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces. High water level alarm in (crash compartment) did not work upon initial testing. Vessel captain corrected on the spot to the satisfaction of MI.
46 CFR 182.530(a)
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 March 2026
Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located, preferably from an accessible position on the weather deck. If the handle to the shutoff valve at the tank is located inside the machinery space, it must be located so that the operator does not have to reach more than 300 millimeters (12 inches) into the machinery space and the valve handle must be shielded from flames by the same material the hull is constructed of, or some noncombustible material. Vessel does not have shielding around fuel shut off valve handles located in E.R. Provide shielding of adequate noncombustible material around valves as discussed with attending Marine Inspector.
46 CFR 182.455(b)(4)
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 25 February 2025
Resolved
The life line shall be properly secured around the sides & ends of the life float. The lifeline, cage & pendants must be as furnished by the mfgr w/ the approved life float or buoyant apparatus. Replacement lifelines & pendants must meet the reqmnts in §160.010 of this chapter. The netting for the cage is breaking down & needs to be repaired. The lifeline attachment to the life float is torn & must be repaired. OLD T: 46 CFR §180.15
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 February 2025
Resolved
The bilge pipe piercing the collision bulkhead shall be fitted w/ a screw-down valve located on the ... after side of the collision bulkhead if it is readily accessible under service conditions. The valve was frozen & must be repaired or replaced.
OLD T: 46 CFR §182.25-5
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 25 February 2025
Resolved
he discharge ends of fuel vents shall be fitted w/ a removable flame screen of 30x30 corrosion resistant mesh. The flame screen for the stbd vent was improperly installed. Replace w/ properly installed flame screen.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 21 March 2024
Resolved
A space containing propulsion machinery must be equipped with a fire detection and alarm system of an approved type. The heat detection system was inoperable in the machinery space. Repair to full operation to the satisfaction of the attending marine inspector prior to the carriage of passengers. 46CFR181.405(a)(1)
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 21 March 2024
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the international and inland navigation rules. The port running light did not illuminate. Vessel is limited to daytime operations until repairs are made to the satisfaction of the attending marine inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 March 2024
Resolved
Openings through which connectors enter shall be adequately closed. Outlet forward of the port engine and outlet located in the centerline between both engines were not adequately closed. 46CFR183.10-20(f) "Old T"
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 March 2024
Resolved
The insulated cape of the connector must be secured. Dead end wires were found above generators in the engine room. Remove or properly secure dead end wires in an enclosure.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 21 March 2024
Resolved
Each disposable hydrostatic release unit(HRU) must be marked with an expiration date of two years after the date on which the unit was installed. EPIRB HRU was expired. Replace HRU prior to carrying passengers.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 23 March 2023
Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve. Life float has a 2" puncture. Repair to the satisfaction of the attending inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 March 2022
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. One of the combined ceiling light/vent protective cover and bulb is missing. Replace missing protective cover to reduce risk of electrical hazard. CITE: 46 CFR §183.200
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 March 2021
Resolved
Each life jacket kept in a stowage container must be readily available; other items are currently stowed in same locker as PFDs, cluttering ease of access. Remove clutter w/PFD storage & arrange PFDs for easier access during emergencies. 46 CFR §180.78(a)(2) - Corrected before completion of inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 24 March 2021
Resolved
Each paddle must be ... lashed to the life float to which it belongs .... One pair of paddles is unlashed and loose. Connect paddles to LF. 46 CFR §180.175(f)(2). Corrected prior to conclusion of inspection.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 24 March 2021
Resolved
Each ship transporting more than 6 psgrs for hire equipped w/a radiotelephone station … must carry a radio operator who … hold[s] a marine radio operator permit or higher class license. The Master's radio operators' permit was not onboard at the time of the inspection. Provide copy of Master's FCC Marine Operator's Permit.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 24 March 2021
Resolved
A separate circuit, w/overcurrent protection at the main distribution panel, must be provided for each radiotelephone installation. There are two back-up VHF radios (w/o DSC) powered by a common circuit. Provide separate circuits for the two auxiliary/back-up VHF radios. 46 CFR §183.392
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 March 2021
Resolved
Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. There is significant corrosion built up on the exposed electrical terminals behind the helm, which can lead to increased resistance, failure of the circuit, or fire. Clean corrosion from terminal blocks behind helm; replace wasted terminals as necessary. 46 CFR §176.800(a)
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 24 March 2021
Resolved
Controls and valves for operation of fixed gas fire extinguishing system must ... [n]ot located in a space that might be inaccessible in the event of fire in the space protected by the system. The break-glass control in the wheelhouse for releasing the CO2 is inaccessible due to a mounted storage box. Remove/relocate storage box in way of CO2 break-glass & pull on bridge. 46 CFR §181.410(b)(ii)
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 24 March 2021
Resolved
All cable and wire must: ... have stranded copper conductors with sufficient current capacity for the circuit in which they are used. Exterior upper deck lighting is wired with solid core 'Romex' wire. Within 30 days provide plan and propose date to replace all solid core wiring with UL Boat Cable or UL Marine Cable.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 24 September 2020
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull.... Marine Inspector discovered small penetrations in vessel's FRP layer on the keel where vessel rests on dry dock blocks. Some rot in the wood was discovered. Identify extent of problem area and repair to the satisfaction of the Marine Inspector prior to credit drydock.
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 20 March 2018
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Navigation › Piloting/Steering › Marine Charts
Issued 20 March 2018
Resolved
Provide up to date nautical charts.
Navigation › Piloting/Steering › US Coast Pilot
Issued 20 March 2018
Resolved
Provide up to date Coast Pilot
Construction/Loadline › Structures › Deck Plating
Issued 28 September 2016
Resolved
Repair/replace bow deck area over second void IWO bulkhead #1 as discussed.
Deck/Cargo › Mooring/Anchoring › Winch
Issued 28 September 2016
Resolved
Replacesheave plate on bow at anchor pulley
Deck/Cargo › Mooring/Anchoring › Winch
Issued 28 September 2016
Resolved
Install chaffe gear on hydrolic lines at bulkhead #1 and seal as discussed.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 29 April 2009
Resolved
Rejected and placed out of service 31 Adult PFD's and 7 Childs PFD's. Vessel passenger count is reduced by 31 adult passengers and 7 child passengers until serviceable PFD's are placed onboard to replace all those rejected.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 29 April 2009
Resolved
Provide current proof of enrollment for all crewmembers in vessels drug consortium program.
Communications › Radio Communications › EPIRB
Issued 19 April 2006
Resolved
Prove registration of EPIRB, vessel restricted to no more than 3 nautical miles from the baseline.
Electrical › Lighting (service) › Lighting Fixture
Issued 19 April 2006
Resolved
Replace damaged deck light globes.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 19 April 2006
Resolved
Adjust bowlight, vessel restricted to daylight operations only until completed.
Electrical › Electric Generation Source (service) › Generator
Issued 19 April 2006
Resolved
Renew battery box cover for gensets.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 12 April 2005
Resolved
Properly label lifejacket stowage by 26 April 05.
Lifesaving › Lifebuoys
Issued 20 April 2004
Resolved
Replace life ring buoy.
Construction/Loadline › Penetrations
Issued 20 April 2004
Resolved
Replace plastic valve (engine room) to fwd rule pump overboard discharge with metal valve. LEGACY COMPONENT DESC: Valve Flange
Construction/Loadline › Penetrations
Issued 20 April 2004
Resolved
Provide valve (manual) to aft rule pump overboard discharge in engine room. LEGACY COMPONENT DESC: Valve Flange
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 10 April 2003
Resolved
Provide navigation rules and CG light list.
Operations/Management › Drills/Instruction › Fire
Issued 10 April 2003
Resolved
Amend emergency instruction list to reflect proper operation of fixed fire fighting system.
Accommodation/Occupational Safety › Medical/First Aid
Issued 18 March 2002
Resolved
First Aid kit incomplete and container not marked. Repair/renew. LEGACY COMPONENT DESC: Medicine Chest
Electrical › Electric Supply System (service)
Issued 18 March 2002
Resolved
Install over current protection on power line from port engine starter to remote switch. LEGACY COMPONENT DESC: Overcurrent Device
Engineering › Reduction Gearing/Clutches
Issued 18 March 2002
Resolved
Clean & lubricate or renew port engine clutch control cable
Fire Fighting › Fixed Fire Detection System
Issued 18 March 2002
Resolved
Power light for fire detection panel missing. repair/renew. LEGACY COMPONENT DESC: Power Supply
Navigation › Collision/Grounding Avoidance
Issued 18 March 2002
Resolved
FWD Mast light not in proper location. Repair/renew. Vsl retricted to daylight ops. LEGACY COMPONENT DESC: Navigation Lights
Lifesaving › Lifejacket/PFD (Type I)
Issued 18 March 2002
Resolved
Clean all PFD's, renew retro tape on 5 adult PFD's. LEGACY COMPONENT DESC: Condition
Lifesaving › Buoyant Apparatus
Issued 18 March 2002
Resolved
22 man life float netting is showing signs of rotting. Repair/renew.
Documentation
Issued 4 April 2001
Resolved
ONE EMPLOYEE NOT ON VSL RANDOM POOL, BELONGS TO ANOTHER ASSOCIATION. MEMBER NEEDS LETTER FROM OTHER ASSOCIATION STATING VSL WILL REC NOTICE OF ANY TESTING RESULTS OR PLACE IN THIS VSL PROGRAM.
Navigation
Issued 4 April 2001
Resolved
STERN AND MAST LITES ARE RESTRICTED. MAKE VISABLE ACCORDING TO NAV RULES. PRIOR TO CARRYING PASSENGERS AT NIGHT OR IN REDUCED VISABILITY.
Construction/Loadline
Issued 4 April 2001
Resolved
AFT BILGE PUMP DISCHARGE HOSE IS PLASTIC. REPAIR/RENEW
Construction/Loadline
Issued 4 April 2001
Resolved
NO HIGH LEVEL ALARM IN FWD PEAK. REPAIR/RENEW
Lifesaving
Issued 12 May 1999
Resolved
PROVIDE A COPY OF THE DRUG SCREENING CONSORTIUM CONTRACT (THE INSTRUCTIONS FOR THE VESSEL OPERATOR).
Lifesaving
Issued 12 May 1999
Resolved
PROVIDE RECORD OF SUPERVISOR TRAINING FOR DRUG SCREENING PROGRAM.
Fire Fighting
Issued 12 May 1999
Resolved
REPLACE BROKEN TAMPER SEALS ON PORTABLE FIRE EXTINGUISHERS.
Fire Fighting
Issued 10 May 1999
Resolved
CONDUCTED INSTALLATION TESTS AND INSPECTION OF FIXED CO2 SYSTEM/PIPING.
Lifesaving
Issued 12 May 1998
Resolved
RECONFIGURE UPPER DECK RAILS TO COMPLY WITH 46 CFR 177.900 AS IT APPLIES TOEXCURSION VESSELS.
Engineering
Issued 7 May 1997
Resolved
MARK FUEL SHUT OFF VALVES.
Lifesaving
Issued 7 May 1997
Resolved
REPAIR BOTH B/A'S, REPAINT AND RESTENCIL W/BOATS NAME AND CAPACITY.
Unknown
Issued 18 June 1996
Resolved
PROVIDE PROOF OF COMPLIANCE WITH HEMICAL TESTING PROGRAM (CREW RANDOM TEST RESULTS AND POSTING HOT LINE NUMBER)
Unknown
Issued 18 June 1996
Resolved
PAINT VSL'S NAME ON HULL
Unknown
Issued 18 June 1996
Resolved
PAINT VSL'S NAME ON LIFE FLOAT, LIFE RING, PADDLES._x001C_ _x001C_ _x001C_ _x001C_
Lifesaving
Issued 18 June 1996
Resolved
POST STABILITY LETTER, EMERGENCY BCST PLACARD, EMERGENCY INSTRUCTIONS ETC.
Lifesaving
Issued 18 June 1996
Resolved
REGISTER 406 EPIRB
Fire Fighting
Issued 18 June 1996
Resolved
PROVIDE FIRE HOSE IAW 46CFR181.320
Unknown
Issued 18 June 1996
Resolved
PROVIDE PROOF OF PAYMENT OF USER FEE_x001C_
Documentation
Issued 30 April 1996
Resolved
PROVIDE EMPLOYEE ASSISTANCE PROGRAM IN ACCORDANCE WITH 46 CFR 16.401
Lifesaving
Issued 30 April 1996
Resolved
PLACE NAME OF VESSEL ON EPIRB
Lifesaving
Issued 30 April 1996
Resolved
REPAINT PORT LIFE FLOAT INTERNATIONAL ORANGE
Lifesaving
Issued 30 April 1996
Resolved
RENEW EPIRB HYDROSTATIC RELEASE
Engineering
Issued 16 May 1995
Resolved
RENEW TWO (2) FUEL OIL SUPPLY HOSES TO GENERATOR WITH APPROVED HOSE AND FITTINGS.
Lifesaving
Issued 4 May 1994
Resolved
INSTALL REFLECTIVE TAPE IAW 46CFR160.010 ON ALL 3 BAs
Lifesaving
Issued 4 May 1994
Resolved
STENCIL LIFE PRESERVER STOWAGE IAW 46CFR185.30-10
Lifesaving
Issued 4 May 1994
Resolved
PROVIDE 1 ADDITIONAL ADULT PFD_x001C_ _x001C_ _x001C_ VESSEL RESTRICTED TO NOT MORE THAN 79 PERSONS ON BOARD UNTIL CORRECTED._x001C_
Navigation
Issued 4 May 1994
Resolved
PROVIDE COAST PILOT AND LIGHT LIST
Electrical
Issued 30 April 1993
Resolved
PROVIDE SPECIFICATIONS FOR NEWLY INSTALLED GENERATOR.
Lifesaving
Issued 30 April 1993
Resolved
PROVIDE ADDITIONAL 6 RED HAND FLARES.
Documentation
Issued 30 April 1993
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Lifesaving
Issued 30 April 1993
Resolved
PRIOR TO CARRYING PASSENGERS THE MASTER SHALL CONDUCT EMERGENCY DRILLS INCLUDING MAN OVERBOARD, FIRE, FLOODING, LOSS OF PROPULSION, AND ABANDON SHIP WITH ALL NORMALLY ASSIGNED VESSEL CREWMEMBERS.
Lifesaving
Issued 30 April 1993
Resolved
THE MASTER SHALL CONDUCT EMERGENCY DRILLS INCLUDING MAN OVERBOARD, FIRE, FLOODING, LOSS OF PROPULSION, AND ABANDON SHIP WITH ALL NORMALLY ASSIGNED VESSEL CREWMEMBERS.
Construction/Loadline
Issued 27 April 1993
Resolved
INSTALL CHECK VALVES OR SHUT-OFF VALVES ON ALL OVERBOARDS AS REQUIRED BY 46CFR 171.119.
Construction/Loadline
Issued 27 April 1993
Resolved
PROVIDE VENTILILATION FOR FORWARD COMPARTMENT AND COLLISION COMPARTMENT IAW46 CFR 177.20(A).
Electrical
Issued 27 April 1993
Resolved
INSTALL ROMEX CONNECTOR IN ELECTRICAL BOXES IN ENGINEROOM TO PROTECT WIRES FROM WARE.
Construction/Loadline
Issued 27 April 1993
Resolved
PROPERLY SUPPORT BILGE PIPING WITHIN ENGINEROOM.
Construction/Loadline
Issued 27 April 1993
Resolved
INSTALL STRAINER ON ENGINEROOM BILGE SUCTION IAW 46 CFR 182.25-10(B).
Construction/Loadline
Issued 27 April 1993
Resolved
CROP AND RENEW AS ORIGINAL ROTTED AREAS PORT AND STARBOARD AT DECK CLAMP INFORWARD COMPARTMENT AND COLLISION COMPARTMENT.
Construction/Loadline
Issued 27 April 1993
Resolved
RENEW ENGINE DRIVEN BILGE PUMP SUCTION HOSE.
Construction/Loadline
Issued 27 April 1993
Resolved
RENEW/REPAIR AS ORIGINAL, IMPACT DAMAGE SPOTS PORT SIDE, FORWARD & AMIDSHIPS.
Lifesaving
Issued 27 April 1990
Resolved
LIFE PRESERVER WATERLIGHT BATTERIES BEYOND EXPIRATION DATE. VESSEL LIMITEDTO VOYAGES NOT MORE THAN 20 MILES FROM A HARBOR OF SAFE REFUGE.
Unknown
Issued 13 May 1987
Resolved
EPIRB DOES NOT TRANSMIT SIGNAL. PROVE PROPER OPERATION OF EPIRB. VESSEL LIMITED TO 20 MILE ROUTE UNTIL PROPER OPERATION DEMONSTRATED.
Lifesaving
Issued 13 May 1987
Resolved
LIFE JACKET PERSONAL FLOATATION DEVICE LIGHT BATTERIES OUTDATED. RENEW PFD LIGHTS PRIOR TO NAVIGATING VESSEL BEYOND 20 MILES FROM A HARBOR OF SAFEREFUGE.
Engineering
Issued 13 May 1987
Resolved
TEMPORARY REPAIR (SOFT PATCH) ON STBD M.E. EXHST LINE IN WAY OF SEA WATER COOLING CONNECTION. MAKE PERMANENT REPAIR TO M.E. EXHAUST.
Lifesaving
Issued 13 May 1987
Resolved
THREE LIFE FLOATS IN DISREPAIR. MAKE PERMANENT REPAIR TO RECONDITION LIFE FLOATS. VESSEL LIMITED TO 20 MILE ROUTE UNTIL COMPLETE.
Casualty record · 1
25 June 2022Routine · role: Involved in a Marine Casualty · 1 dead · activity 7488791
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.