MAURY USCG vessel records Sign in
← All vessels

BIG MOHAWK

BIG MOHAWK is a 1976 passenger vessel (inspected). The Coast Guard has recorded 78 inspections since 1985, most recently in March 2026, along with 96 deficiencies and 1 casualty investigation in 2022.

Records from 1985 to 2026. Most recent: inspection, 19 March 2026.

Built
1976
Last inspected
19 March 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDG5826
Flag
UNITED STATES
367550680
Maury page id
psix-48758

Inspections, by type

…with no type recorded3
Years with a record 38 calendar years (1985–2026)
The 78 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)61.3 ft × 19.8 ft × 5.3 ft
Registered tonnagegross 62 / net 42
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderLYDIA YACHTS INC · STUART, FL, UNITED STATES · built 1976
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portBELMAR, NJ
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 17 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it62 - Regulatory (Subpart C or D), Gross Ton
42 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDN5972MMSI 367550680 · active · compulsorily equipped · granted 1 February 2023, expires 1 February 2033
WDG5826MMSI 367550680 · expired · compulsorily equipped · granted 19 October 2012, cancelled 24 December 2022
WCW9638MMSI 367151220 · expired · compulsorily equipped · granted 16 November 2006, cancelled 4 February 2017 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 78

19 March 2026 Annual Inspection · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8290405
15 April 2025 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8111905
25 February 2025 COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8082725
18 September 2024 Drydock Exam · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7979417
21 March 2024 Annual Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7881997
3 October 2023 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7802673
23 March 2023 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7617310
22 September 2022 Internal Structural Exam · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7530526
25 June 2022 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7488791
24 March 2022 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7393268
21 September 2021 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7282936
21 September 2021 Deficiency Check · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7383602
24 March 2021 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7160832
24 September 2020 Internal Structural Exam · Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7064029
17 March 2020 COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6925910
25 February 2019 DAPI Audit · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6631928
27 September 2018 Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6548347
20 March 2018 Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6372431
15 March 2017 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6105073
28 September 2016 Administrative Inspection · Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6029165
26 April 2016 Plan Review "T" Boat · Deficiency Check · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5862814
1 March 2016 Annual Inspection · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5824513
1 October 2014 Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4999864
6 May 2014 Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4865130
27 October 2010 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3878684
29 April 2009 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3463561
23 October 2008 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3349985
3 April 2008 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3176663
21 March 2007 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2892285
19 April 2006 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2627994
12 April 2005 COI Inspection · Deficiency Check
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2331504
3 November 2004 Internal Structural Exam · Hull Examination
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2230935
20 April 2004 Annual Inspection · MARPOL Annex V Examination
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2044642
10 April 2003 Annual Inspection · MARPOL Annex V Examination
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1769485
13 November 2002 Hull Examination · Internal Structural Exam
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1700809
18 March 2002 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1494063
4 April 2001 MARPOL Annex V Examination · Re-Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1454958
10 May 2000 COI Inspection · MARPOL Annex V Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1376157
10 May 2000 Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1464244
22 June 1999 Administrative
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1454689
12 May 1999 Deficiency Check · Re-Inspection · MARPOL Annex V Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1453617
10 May 1999 Plan Review "T" Boat
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1129435
27 October 1998 Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 804380
12 May 1998 Re-Inspection · MARPOL Annex V Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 790877
7 May 1997 COI Inspection · MARPOL Annex V Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1105060
31 October 1996 Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1166449
15 October 1996 Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1430293
18 June 1996 MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1193686
30 April 1996 MARPOL Annex V Examination · Deficiency Check · Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1080391
16 May 1995 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 923254
28 April 1995 Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1179335
30 June 1994 Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1138069
5 May 1994 Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 858300
4 May 1994 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1168513
15 April 1994 Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1168083
14 July 1993 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1156393
14 June 1993 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 839150
30 April 1993 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 831948
27 April 1993 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 836263
27 April 1993 Administrative
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1143964
29 April 1992 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 953599
29 April 1991 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1214076
24 April 1991 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 934947
12 October 1990 Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 911389
14 September 1990 Drydock Extension
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 918291
24 July 1990 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1224398
27 April 1990 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1231094
27 April 1989 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 896431
10 March 1989 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 902200
3 January 1989 Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1346828
5 April 1988 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1197372
13 May 1987 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1023476
7 May 1987 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1335912
16 September 1986 Credit Drydock
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1311169
6 May 1986 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1296000
27 November 1985 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1307419
26 March 1985 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 980602
22 March 1985 Credit Drydock
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 980606

Deficiency record · 96

07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 19 March 2026 Resolved
A space containing propulsion machinery must be equipped with a fire detection and alarm system of an approved type. The heat detection in the engine room had not been tested by third party and crew was not comfortable testing during inspection. Have certified or licensed state or local fire extinguishing agency test and certify heat detector prior to the carriage of passengers. 46 CFR 181.405(a)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 March 2026
Resolution: Received, reviewed and approved testing certificate from third party for heat detector.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 19 March 2026 Resolved
The number of penetrations in a watertight bulkhead must be minimized. A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable and made watertight. Crew has drilled several 1 inch holes to run wiring through several watertight bulkheads from crash compartment to engine compartment. Fill all holes to ensure watertight integrity of bulkheads prior to carriage of passengers. 46 CFR 179.320(c)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 March 2026
Resolution: received pictures showing holes identified during annual have been filled.
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 19 March 2026 Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with § 80.59 once every five years. Vessels safety telephony certificate is expired. Vessel is restricted to 1000 ft. from shore until renewed. 47 CFR 80.903
Action required: 705 - Other - as specified
Resolved 23 March 2026
Resolution: FCC Radiotelephony certificate renewed.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 19 March 2026 Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. EPIRB hydrostatic release unit expires at the end of the month (13 days) Replace HRU prior to the carriage of passengers. 46 CFR 180.64
Action required: 705 - Other - as specified
Resolved 23 March 2026
Resolution: New EPIRB HRU purchased and installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 March 2026 Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, as indicated by the vessel's stability letter, the maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least 25 millimeters (1 inch) numbers and letters at the entranceway to that deck. Upper deck max pax accommodation is marked for 36 pax instead of 33 pax per stability letter and COI. Make change and mark accordingly. 46 CFR 185.602(g)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2026
Resolved 23 March 2026
Resolution: upper deck max pax has been marked accordingly. (33 pax)
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 March 2026 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew. Vessel had incomplete kit with expired items. Provide new first aid kit to the satisfaction of MI. 46 CFR 184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2026
Resolved 23 March 2026
Resolution: First aid kit has been purchased to satisfy the requirements.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 19 March 2026 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces. High water level alarm in (crash compartment) did not work upon initial testing. Vessel captain corrected on the spot to the satisfaction of MI. 46 CFR 182.530(a)
Action required: 10 - Deficiency Rectified
Resolved 19 March 2026
Resolution: high water alarn works.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 March 2026 Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located, preferably from an accessible position on the weather deck. If the handle to the shutoff valve at the tank is located inside the machinery space, it must be located so that the operator does not have to reach more than 300 millimeters (12 inches) into the machinery space and the valve handle must be shielded from flames by the same material the hull is constructed of, or some noncombustible material. Vessel does not have shielding around fuel shut off valve handles located in E.R. Provide shielding of adequate noncombustible material around valves as discussed with attending Marine Inspector. 46 CFR 182.455(b)(4)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 March 2026
Resolution: Adequate shielding has been built around fuel shut off valves as required.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 25 February 2025 Resolved
The life line shall be properly secured around the sides & ends of the life float. The lifeline, cage & pendants must be as furnished by the mfgr w/ the approved life float or buoyant apparatus. Replacement lifelines & pendants must meet the reqmnts in §160.010 of this chapter. The netting for the cage is breaking down & needs to be repaired. The lifeline attachment to the life float is torn & must be repaired. OLD T: 46 CFR §180.15
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 March 2025
Resolved 15 April 2025
Resolution: Hand line repaired
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 February 2025 Resolved
The bilge pipe piercing the collision bulkhead shall be fitted w/ a screw-down valve located on the ... after side of the collision bulkhead if it is readily accessible under service conditions. The valve was frozen & must be repaired or replaced. OLD T: 46 CFR §182.25-5
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 March 2025
Resolved 17 April 2025
Resolution: New ball valve installed.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 25 February 2025 Resolved
he discharge ends of fuel vents shall be fitted w/ a removable flame screen of 30x30 corrosion resistant mesh. The flame screen for the stbd vent was improperly installed. Replace w/ properly installed flame screen.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 March 2025
Resolved 15 April 2025
Resolution: Flame screen installed
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 21 March 2024 Resolved
A space containing propulsion machinery must be equipped with a fire detection and alarm system of an approved type. The heat detection system was inoperable in the machinery space. Repair to full operation to the satisfaction of the attending marine inspector prior to the carriage of passengers. 46CFR181.405(a)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 April 2024
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 21 March 2024 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the international and inland navigation rules. The port running light did not illuminate. Vessel is limited to daytime operations until repairs are made to the satisfaction of the attending marine inspector.
Action required: 705 - Other - as specified
Resolved 18 April 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 March 2024 Resolved
Openings through which connectors enter shall be adequately closed. Outlet forward of the port engine and outlet located in the centerline between both engines were not adequately closed. 46CFR183.10-20(f) "Old T"
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 April 2024
Resolved 18 April 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 March 2024 Resolved
The insulated cape of the connector must be secured. Dead end wires were found above generators in the engine room. Remove or properly secure dead end wires in an enclosure.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 April 2024
Resolved 18 April 2024
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 21 March 2024 Resolved
Each disposable hydrostatic release unit(HRU) must be marked with an expiration date of two years after the date on which the unit was installed. EPIRB HRU was expired. Replace HRU prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 April 2024
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 23 March 2023 Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve. Life float has a 2" puncture. Repair to the satisfaction of the attending inspector.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 April 2023
Resolved 3 October 2023
Resolution: Repaired
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 March 2022 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. One of the combined ceiling light/vent protective cover and bulb is missing. Replace missing protective cover to reduce risk of electrical hazard. CITE: 46 CFR §183.200
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 April 2022
Resolved 7 April 2022
Resolution: Vessel owner provided photo of installed plexiglass cover for overhead light.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 March 2021 Resolved
Each life jacket kept in a stowage container must be readily available; other items are currently stowed in same locker as PFDs, cluttering ease of access. Remove clutter w/PFD storage & arrange PFDs for easier access during emergencies. 46 CFR §180.78(a)(2) - Corrected before completion of inspection.
Action required: 10 - Deficiency Rectified
Due 7 April 2021
Resolved 24 March 2021
Resolution: Corrected before completion of inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 24 March 2021 Resolved
Each paddle must be ... lashed to the life float to which it belongs .... One pair of paddles is unlashed and loose. Connect paddles to LF. 46 CFR §180.175(f)(2). Corrected prior to conclusion of inspection.
Action required: 10 - Deficiency Rectified
Due 7 April 2021
Resolved 24 March 2021
Resolution: Corrected prior to conclusion of inspection.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 24 March 2021 Resolved
Each ship transporting more than 6 psgrs for hire equipped w/a radiotelephone station … must carry a radio operator who … hold[s] a marine radio operator permit or higher class license. The Master's radio operators' permit was not onboard at the time of the inspection. Provide copy of Master's FCC Marine Operator's Permit.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 April 2021
Resolved 2 April 2021
Resolution: Cleared via photo provided by o/o.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 24 March 2021 Resolved
A separate circuit, w/overcurrent protection at the main distribution panel, must be provided for each radiotelephone installation. There are two back-up VHF radios (w/o DSC) powered by a common circuit. Provide separate circuits for the two auxiliary/back-up VHF radios. 46 CFR §183.392
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 April 2021
Resolved 1 April 2021
Resolution: Item cleared via photos provided by vsl o/o.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 March 2021 Resolved
Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. There is significant corrosion built up on the exposed electrical terminals behind the helm, which can lead to increased resistance, failure of the circuit, or fire. Clean corrosion from terminal blocks behind helm; replace wasted terminals as necessary. 46 CFR §176.800(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 April 2021
Resolved 1 April 2021
Resolution: Item cleared via photos provided by vsl o/o.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 24 March 2021 Resolved
Controls and valves for operation of fixed gas fire extinguishing system must ... [n]ot located in a space that might be inaccessible in the event of fire in the space protected by the system. The break-glass control in the wheelhouse for releasing the CO2 is inaccessible due to a mounted storage box. Remove/relocate storage box in way of CO2 break-glass & pull on bridge. 46 CFR §181.410(b)(ii)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 April 2021
Resolved 30 March 2021
Resolution: Def cleared via photo provided by o/o.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 24 March 2021 Resolved
All cable and wire must: ... have stranded copper conductors with sufficient current capacity for the circuit in which they are used. Exterior upper deck lighting is wired with solid core 'Romex' wire. Within 30 days provide plan and propose date to replace all solid core wiring with UL Boat Cable or UL Marine Cable.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 April 2021
Resolved 21 September 2021
Resolution: Resolved via photos. Copies uploaded.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 24 September 2020 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull.... Marine Inspector discovered small penetrations in vessel's FRP layer on the keel where vessel rests on dry dock blocks. Some rot in the wood was discovered. Identify extent of problem area and repair to the satisfaction of the Marine Inspector prior to credit drydock.
Action required: 705 - Other - as specified
Due 24 September 2020
Resolved 25 September 2020
Resolution: O/O replaced small sections of keel wood with 2" dutchman, new FRP glass and resin to match existing lay up of vessel.
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 20 March 2018 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Resolved 2 October 2018
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Navigation › Piloting/Steering › Marine Charts
Issued 20 March 2018 Resolved
Provide up to date nautical charts.
Action required: 705 - Other - as specified
Due 3 April 2018
Resolved 27 March 2018
Resolution: O/O purchased up to date nautical charts
Navigation › Piloting/Steering › US Coast Pilot
Issued 20 March 2018 Resolved
Provide up to date Coast Pilot
Action required: 705 - Other - as specified
Due 3 April 2018
Resolved 27 March 2018
Resolution: O/O downloadeded most up to date coast pilot
Construction/Loadline › Structures › Deck Plating
Issued 28 September 2016 Resolved
Repair/replace bow deck area over second void IWO bulkhead #1 as discussed.
Action required: 705 - Other - as specified
Resolved 11 October 2016
Deck/Cargo › Mooring/Anchoring › Winch
Issued 28 September 2016 Resolved
Replacesheave plate on bow at anchor pulley
Action required: 705 - Other - as specified
Resolved 25 October 2016
Resolution: Cut out wasted area and welded new
Deck/Cargo › Mooring/Anchoring › Winch
Issued 28 September 2016 Resolved
Install chaffe gear on hydrolic lines at bulkhead #1 and seal as discussed.
Action required: 705 - Other - as specified
Resolved 30 September 2016
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 29 April 2009 Resolved
Rejected and placed out of service 31 Adult PFD's and 7 Childs PFD's. Vessel passenger count is reduced by 31 adult passengers and 7 child passengers until serviceable PFD's are placed onboard to replace all those rejected.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 April 2009
Resolution: Vessel owner/operator replaced all rejected PFD''s with 31 new Adult type I PFD''s and 7 childs type I PFD''s prior to my departure from the inspection.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 29 April 2009 Resolved
Provide current proof of enrollment for all crewmembers in vessels drug consortium program.
Due 30 April 2009
Resolved 30 April 2009
Resolution: Provided current proof of enrollment for all crewmembers in vessels drug consortium program.
Communications › Radio Communications › EPIRB
Issued 19 April 2006 Resolved
Prove registration of EPIRB, vessel restricted to no more than 3 nautical miles from the baseline.
Action required: 705 - Other - as specified
Resolved 26 April 2006
Resolution: Per fax ltr fm O/O, ltr scanned into documents for this activity.
Electrical › Lighting (service) › Lighting Fixture
Issued 19 April 2006 Resolved
Replace damaged deck light globes.
Due 26 April 2006
Resolved 26 April 2006
Resolution: Per fax ltr fm O/O, ltr scanned into documents for this activity.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 19 April 2006 Resolved
Adjust bowlight, vessel restricted to daylight operations only until completed.
Action required: 705 - Other - as specified
Resolved 26 April 2006
Resolution: Per fax ltr fm O/O, ltr scanned into documents for this activity.
Electrical › Electric Generation Source (service) › Generator
Issued 19 April 2006 Resolved
Renew battery box cover for gensets.
Due 26 April 2006
Resolved 26 April 2006
Resolution: Per fax ltr fm O/O, ltr scanned into documents for this activity.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 12 April 2005 Resolved
Properly label lifejacket stowage by 26 April 05.
Due 26 April 2005
Resolved 24 April 2005
Resolution: Per fax ltr fm O/O, ltr scanned into documents for this inspection.
Lifesaving › Lifebuoys
Issued 20 April 2004 Resolved
Replace life ring buoy.
Due 1 May 2004
Resolved 22 April 2004
Construction/Loadline › Penetrations
Issued 20 April 2004 Resolved
Replace plastic valve (engine room) to fwd rule pump overboard discharge with metal valve. LEGACY COMPONENT DESC: Valve Flange
Due 1 May 2004
Resolved 22 April 2004
Construction/Loadline › Penetrations
Issued 20 April 2004 Resolved
Provide valve (manual) to aft rule pump overboard discharge in engine room. LEGACY COMPONENT DESC: Valve Flange
Due 1 May 2004
Resolved 22 April 2004
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 10 April 2003 Resolved
Provide navigation rules and CG light list.
Due 20 April 2003
Resolved 25 April 2003
Operations/Management › Drills/Instruction › Fire
Issued 10 April 2003 Resolved
Amend emergency instruction list to reflect proper operation of fixed fire fighting system.
Due 21 April 2003
Resolved 25 April 2003
Accommodation/Occupational Safety › Medical/First Aid
Issued 18 March 2002 Resolved
First Aid kit incomplete and container not marked. Repair/renew. LEGACY COMPONENT DESC: Medicine Chest
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 March 2002
Resolved 24 April 2002
Resolution: Restocked
Electrical › Electric Supply System (service)
Issued 18 March 2002 Resolved
Install over current protection on power line from port engine starter to remote switch. LEGACY COMPONENT DESC: Overcurrent Device
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 April 2002
Resolved 24 April 2002
Resolution: fuse installed
Engineering › Reduction Gearing/Clutches
Issued 18 March 2002 Resolved
Clean & lubricate or renew port engine clutch control cable
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 April 2002
Resolved 24 April 2002
Fire Fighting › Fixed Fire Detection System
Issued 18 March 2002 Resolved
Power light for fire detection panel missing. repair/renew. LEGACY COMPONENT DESC: Power Supply
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 April 2002
Resolved 24 April 2002
Resolution: serviced
Navigation › Collision/Grounding Avoidance
Issued 18 March 2002 Resolved
FWD Mast light not in proper location. Repair/renew. Vsl retricted to daylight ops. LEGACY COMPONENT DESC: Navigation Lights
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 April 2002
Resolved 24 April 2002
Resolution: Installed
Lifesaving › Lifejacket/PFD (Type I)
Issued 18 March 2002 Resolved
Clean all PFD's, renew retro tape on 5 adult PFD's. LEGACY COMPONENT DESC: Condition
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 April 2002
Resolved 24 April 2002
Lifesaving › Buoyant Apparatus
Issued 18 March 2002 Resolved
22 man life float netting is showing signs of rotting. Repair/renew.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 November 2002
Resolved 24 April 2002
Resolution: NEW FLOAT INSTALLED
Documentation
Issued 4 April 2001 Resolved
ONE EMPLOYEE NOT ON VSL RANDOM POOL, BELONGS TO ANOTHER ASSOCIATION. MEMBER NEEDS LETTER FROM OTHER ASSOCIATION STATING VSL WILL REC NOTICE OF ANY TESTING RESULTS OR PLACE IN THIS VSL PROGRAM.
Condition: Unknown
Due 5 June 2001
Resolved 5 June 2001
Navigation
Issued 4 April 2001 Resolved
STERN AND MAST LITES ARE RESTRICTED. MAKE VISABLE ACCORDING TO NAV RULES. PRIOR TO CARRYING PASSENGERS AT NIGHT OR IN REDUCED VISABILITY.
Condition: Unknown
Due 5 June 2001
Resolved 5 June 2001
Construction/Loadline
Issued 4 April 2001 Resolved
AFT BILGE PUMP DISCHARGE HOSE IS PLASTIC. REPAIR/RENEW
Condition: Unknown
Due 5 June 2001
Resolved 5 June 2001
Construction/Loadline
Issued 4 April 2001 Resolved
NO HIGH LEVEL ALARM IN FWD PEAK. REPAIR/RENEW
Condition: Unknown
Due 5 June 2001
Resolved 5 June 2001
Lifesaving
Issued 12 May 1999 Resolved
PROVIDE A COPY OF THE DRUG SCREENING CONSORTIUM CONTRACT (THE INSTRUCTIONS FOR THE VESSEL OPERATOR).
Condition: Unknown
Due 17 June 1999
Resolved 17 June 1999
Lifesaving
Issued 12 May 1999 Resolved
PROVIDE RECORD OF SUPERVISOR TRAINING FOR DRUG SCREENING PROGRAM.
Condition: Unknown
Due 17 June 1999
Resolved 17 June 1999
Fire Fighting
Issued 12 May 1999 Resolved
REPLACE BROKEN TAMPER SEALS ON PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 17 June 1999
Resolved 17 June 1999
Fire Fighting
Issued 10 May 1999 Resolved
CONDUCTED INSTALLATION TESTS AND INSPECTION OF FIXED CO2 SYSTEM/PIPING.
Condition: Unknown
Due 10 May 1999
Resolved 10 May 1999
Lifesaving
Issued 12 May 1998 Resolved
RECONFIGURE UPPER DECK RAILS TO COMPLY WITH 46 CFR 177.900 AS IT APPLIES TOEXCURSION VESSELS.
Condition: Unknown
Due 12 November 1998
Resolved 28 May 1998
Engineering
Issued 7 May 1997 Resolved
MARK FUEL SHUT OFF VALVES.
Condition: Unknown
Due 14 May 1997
Resolved 13 May 1997
Lifesaving
Issued 7 May 1997 Resolved
REPAIR BOTH B/A'S, REPAINT AND RESTENCIL W/BOATS NAME AND CAPACITY.
Condition: Unknown
Due 14 May 1997
Resolved 13 May 1997
Unknown
Issued 18 June 1996 Resolved
PROVIDE PROOF OF COMPLIANCE WITH HEMICAL TESTING PROGRAM (CREW RANDOM TEST RESULTS AND POSTING HOT LINE NUMBER)
Condition: Unknown
Due 23 July 1996
Resolved 23 July 1996
Unknown
Issued 18 June 1996 Resolved
PAINT VSL'S NAME ON HULL
Condition: Unknown
Due 23 July 1996
Resolved 23 July 1996
Unknown
Issued 18 June 1996 Resolved
PAINT VSL'S NAME ON LIFE FLOAT, LIFE RING, PADDLES._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 July 1996
Resolved 23 July 1996
Lifesaving
Issued 18 June 1996 Resolved
POST STABILITY LETTER, EMERGENCY BCST PLACARD, EMERGENCY INSTRUCTIONS ETC.
Condition: Unknown
Due 23 July 1996
Resolved 23 July 1996
Lifesaving
Issued 18 June 1996 Resolved
REGISTER 406 EPIRB
Condition: Unknown
Due 23 July 1996
Resolved 23 July 1996
Fire Fighting
Issued 18 June 1996 Resolved
PROVIDE FIRE HOSE IAW 46CFR181.320
Condition: Unknown
Due 23 July 1996
Resolved 23 July 1996
Unknown
Issued 18 June 1996 Resolved
PROVIDE PROOF OF PAYMENT OF USER FEE_x001C_
Condition: Unknown
Due 23 July 1996
Resolved 23 July 1996
Documentation
Issued 30 April 1996 Resolved
PROVIDE EMPLOYEE ASSISTANCE PROGRAM IN ACCORDANCE WITH 46 CFR 16.401
Condition: Unknown
Due 15 May 1996
Resolved 8 May 1996
Lifesaving
Issued 30 April 1996 Resolved
PLACE NAME OF VESSEL ON EPIRB
Condition: Unknown
Due 15 May 1996
Resolved 8 May 1996
Lifesaving
Issued 30 April 1996 Resolved
REPAINT PORT LIFE FLOAT INTERNATIONAL ORANGE
Condition: Unknown
Due 15 May 1996
Resolved 8 May 1996
Lifesaving
Issued 30 April 1996 Resolved
RENEW EPIRB HYDROSTATIC RELEASE
Condition: Unknown
Due 15 May 1996
Resolved 8 May 1996
Engineering
Issued 16 May 1995 Resolved
RENEW TWO (2) FUEL OIL SUPPLY HOSES TO GENERATOR WITH APPROVED HOSE AND FITTINGS.
Condition: Unknown
Due 16 May 1995
Resolved 16 May 1995
Lifesaving
Issued 4 May 1994 Resolved
INSTALL REFLECTIVE TAPE IAW 46CFR160.010 ON ALL 3 BAs
Condition: Unknown
Due 4 May 1994
Resolved 4 May 1994
Lifesaving
Issued 4 May 1994 Resolved
STENCIL LIFE PRESERVER STOWAGE IAW 46CFR185.30-10
Condition: Unknown
Due 4 May 1994
Resolved 4 May 1994
Lifesaving
Issued 4 May 1994 Resolved
PROVIDE 1 ADDITIONAL ADULT PFD_x001C_ _x001C_ _x001C_ VESSEL RESTRICTED TO NOT MORE THAN 79 PERSONS ON BOARD UNTIL CORRECTED._x001C_
Condition: Unknown
Due 5 May 1994
Resolved 5 May 1994
Navigation
Issued 4 May 1994 Resolved
PROVIDE COAST PILOT AND LIGHT LIST
Condition: Unknown
Due 5 May 1994
Resolved 5 May 1994
Electrical
Issued 30 April 1993 Resolved
PROVIDE SPECIFICATIONS FOR NEWLY INSTALLED GENERATOR.
Condition: Unknown
Due 30 April 1993
Resolved 30 April 1993
Lifesaving
Issued 30 April 1993 Resolved
PROVIDE ADDITIONAL 6 RED HAND FLARES.
Condition: Unknown
Due 30 April 1993
Resolved 30 April 1993
Documentation
Issued 30 April 1993 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 30 April 1993
Resolved 30 April 1993
Lifesaving
Issued 30 April 1993 Resolved
PRIOR TO CARRYING PASSENGERS THE MASTER SHALL CONDUCT EMERGENCY DRILLS INCLUDING MAN OVERBOARD, FIRE, FLOODING, LOSS OF PROPULSION, AND ABANDON SHIP WITH ALL NORMALLY ASSIGNED VESSEL CREWMEMBERS.
Condition: Unknown
Due 30 April 1993
Resolved 30 April 1993
Lifesaving
Issued 30 April 1993 Resolved
THE MASTER SHALL CONDUCT EMERGENCY DRILLS INCLUDING MAN OVERBOARD, FIRE, FLOODING, LOSS OF PROPULSION, AND ABANDON SHIP WITH ALL NORMALLY ASSIGNED VESSEL CREWMEMBERS.
Condition: Unknown
Due 30 April 1993
Resolved 30 April 1993
Construction/Loadline
Issued 27 April 1993 Resolved
INSTALL CHECK VALVES OR SHUT-OFF VALVES ON ALL OVERBOARDS AS REQUIRED BY 46CFR 171.119.
Condition: Unknown
Due 27 April 1993
Resolved 27 April 1993
Construction/Loadline
Issued 27 April 1993 Resolved
PROVIDE VENTILILATION FOR FORWARD COMPARTMENT AND COLLISION COMPARTMENT IAW46 CFR 177.20(A).
Condition: Unknown
Due 27 April 1993
Resolved 27 April 1993
Electrical
Issued 27 April 1993 Resolved
INSTALL ROMEX CONNECTOR IN ELECTRICAL BOXES IN ENGINEROOM TO PROTECT WIRES FROM WARE.
Condition: Unknown
Due 27 April 1993
Resolved 27 April 1993
Construction/Loadline
Issued 27 April 1993 Resolved
PROPERLY SUPPORT BILGE PIPING WITHIN ENGINEROOM.
Condition: Unknown
Due 27 April 1993
Resolved 27 April 1993
Construction/Loadline
Issued 27 April 1993 Resolved
INSTALL STRAINER ON ENGINEROOM BILGE SUCTION IAW 46 CFR 182.25-10(B).
Condition: Unknown
Due 27 April 1993
Resolved 27 April 1993
Construction/Loadline
Issued 27 April 1993 Resolved
CROP AND RENEW AS ORIGINAL ROTTED AREAS PORT AND STARBOARD AT DECK CLAMP INFORWARD COMPARTMENT AND COLLISION COMPARTMENT.
Condition: Unknown
Due 27 April 1993
Resolved 27 April 1993
Construction/Loadline
Issued 27 April 1993 Resolved
RENEW ENGINE DRIVEN BILGE PUMP SUCTION HOSE.
Condition: Unknown
Due 27 April 1993
Resolved 27 April 1993
Construction/Loadline
Issued 27 April 1993 Resolved
RENEW/REPAIR AS ORIGINAL, IMPACT DAMAGE SPOTS PORT SIDE, FORWARD & AMIDSHIPS.
Condition: Unknown
Due 27 April 1993
Resolved 27 April 1993
Lifesaving
Issued 27 April 1990 Resolved
LIFE PRESERVER WATERLIGHT BATTERIES BEYOND EXPIRATION DATE. VESSEL LIMITEDTO VOYAGES NOT MORE THAN 20 MILES FROM A HARBOR OF SAFE REFUGE.
Condition: Unknown
Due 27 April 1990
Resolved 27 April 1990
Unknown
Issued 13 May 1987 Resolved
EPIRB DOES NOT TRANSMIT SIGNAL. PROVE PROPER OPERATION OF EPIRB. VESSEL LIMITED TO 20 MILE ROUTE UNTIL PROPER OPERATION DEMONSTRATED.
Condition: Unknown
Due 13 May 1987
Resolved 13 May 1987
Lifesaving
Issued 13 May 1987 Resolved
LIFE JACKET PERSONAL FLOATATION DEVICE LIGHT BATTERIES OUTDATED. RENEW PFD LIGHTS PRIOR TO NAVIGATING VESSEL BEYOND 20 MILES FROM A HARBOR OF SAFEREFUGE.
Condition: Unknown
Due 13 May 1987
Resolved 13 May 1987
Engineering
Issued 13 May 1987 Resolved
TEMPORARY REPAIR (SOFT PATCH) ON STBD M.E. EXHST LINE IN WAY OF SEA WATER COOLING CONNECTION. MAKE PERMANENT REPAIR TO M.E. EXHAUST.
Condition: Unknown
Due 13 May 1987
Resolved 13 May 1987
Lifesaving
Issued 13 May 1987 Resolved
THREE LIFE FLOATS IN DISREPAIR. MAKE PERMANENT REPAIR TO RECONDITION LIFE FLOATS. VESSEL LIMITED TO 20 MILE ROUTE UNTIL COMPLETE.
Condition: Unknown
Due 13 May 1987
Resolved 13 May 1987

Casualty record · 1

25 June 2022Routine · role: Involved in a Marine Casualty · 1 dead · activity 7488791
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.