← All vessels
SEACOR RIGOROUS
Offshore Supply Vessel · Offshore class · Built 2000s · USCG Heartland District (CGD-H) · Other hulls named SEACOR RIGOROUS
SEACOR RIGOROUS is a 2000 offshore supply vessel. The Coast Guard has recorded 30 inspections since 1998, most recently in June 2019, along with 25 deficiencies and 2 casualty investigations in 2015.
Records from 1998 to 2019. Most recent: inspection, 3 June 2019.
- Built
- 2000
- Last inspected
- 3 June 2019
- Documentation
- Expired · documentation file of 10 September 2026
- Deficiencies
- 25 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 2 investigations · 2015
Identity
1096765
9236937 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WCZ9586
487718
Flag
UNITED STATES
338280000 (licence lapsed)
Maury page id
psix-487718
Inspections, by type
…with no type recorded4
Years with a record
17 calendar years (1998–2019)
The 30 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.
Documentation record
Registered dimensions (L × B × D)226.0 ft × 56.0 ft × 21.0 ft
Registered tonnagegross 2,137 / net 714
ITC dimensions (L × B × D)226.0 ft × 56.0 ft × 21.0 ft
ITC tonnagegross 2,137 / net 714
BuilderN. AMERICAN SHIPBUILDING · LAROSE, LA, UNITED STATES · built 2000
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationExpired · issued 30 June 2004
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it2885 - Dead Weight, Ton
4864 - Displacement, Ton
2137 - Convention (Subpart B), Gross Ton
714 - Convention (Subpart B), Net Ton
4864 - Displacement, Ton
2137 - Convention (Subpart B), Gross Ton
714 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WCZ9586MMSI 338280000 · expired · compulsorily equipped · granted 4 June 2010, cancelled 26 September 2020
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 30
3 June 2019
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6702083
16 March 2018
Internal Structural Exam · Examination of Repairs · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6373219
20 September 2017
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6271189
5 April 2016
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5876540
21 January 2016
Annual Inspection · MARPOL Annex VI Survey · MTSA/ISPS Verification · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5790642
20 January 2011
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3929762
22 December 2009
Ballast Water Examination · MARPOL Annex VI Survey · MTSA/ISPS Verification · Administrative Inspection · Annual Inspection · MARPOL Annex I Examination · Cargo Tank Internal · Deficiency Check · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3654140
23 January 2009
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3398731
24 November 2008
Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3360497
2 May 2008
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3197117
2 October 2007
Cargo Tank Internal · Annual Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3071509
30 October 2006
Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2810559
5 October 2006
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2808071
27 September 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2502019
8 September 2005
MARPOL Annex I Examination · MTSA/ISPS Verification · COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2485510
19 August 2005
Examination of Repairs · Hull Examination · Internal Structural Exam · Cargo Tank Internal
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2467173
16 February 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2293916
30 November 2004
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2250658
21 October 2004
MTSA/ISPS Verification · Re-Inspection · MARPOL Annex I Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2226322
20 August 2004
Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2176557
4 November 2003
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1941711
3 November 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1979623
27 May 2003
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1802648
29 April 2003
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1802483
29 October 2002
Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1697737
24 August 2001
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1391676
31 August 2000
Deadweight Survey · Initial Certification · Initial Construction-Excluding Oversight
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1369816
31 March 2000
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1050083
30 June 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1129593
1 December 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 813132
Deficiency record · 25
Deck/Cargo › Cargo Transfer (solid) › General
Issued 21 January 2016
Resolved
5 year crane test requires tests at maximum and minimum angles. Only maximum angle was tested. Retest IAW API 2P RD.
Lifesaving › Launching Appliances › Davit
Issued 21 January 2016
Resolved
5 year weight test for rescue boat daveit requires dynamic weight test. Only static weight test was conducted. Conduct dynamic weight test at 1.1X B weight.
Operations/Management › Pollution › Control of Garbage
Issued 21 January 2016
Resolved
Vessel discharged unground food waste into MARPOL Annex V special area.
Communications › Public Address System › Announcing Station
Issued 24 November 2008
Resolved
Install PA/ General alarm interupt that automatically shuts of during General Alarm operation. Current system set up could cause General alarm to be disabled. SOLA Requirement
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 24 November 2008
Resolved
Demonstrate proper operation of OWS.
Communications › Radio Communications › EPIRB
Issued 24 November 2008
Resolved
Relocate EPIRB to prevent verticle access. Move from above Bridge to lower level
Lifesaving › Rescue Boat › Propulsion Engine
Issued 24 November 2008
Resolved
Incorporate Installed Rescue boat engine maintenacne to include maintenance required by manufacturer. Perform maintenance required by manufacturer.
Communications › Alarms/Indicators › Steering Failure Alarm System
Issued 24 November 2008
Resolved
Demontrate proper operation of Steering failure alarm. Incorporate steering failure test procedures in Automation test book.
Lifesaving › Rescue Boat › Propulsion Starting System
Issued 24 November 2008
Resolved
Charge Rescue boat battery weekly and log in lifesaving maintenance record or install permenant battery charger.
Communications › Alarms/Indicators › Lube Oil Level Alarm
Issued 24 November 2008
Resolved
Show proper operation of alarm system for engine and generators from operation station.
Communications › Audible Communications › SPD (Other)
Issued 5 October 2006
Resolved
DEMONSTRATE PROPER OPERATION OF PUBLIC ADDRESS INTERRUPT DURING GENERAL ALARM BELL SOUNDING.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 21 October 2004
Resolved
Renew 60 second time delay bottle IWO engine room fixed CO2 system due to actuation at 41seconds.
Documentation › Safety Management System › Conformity Maintenance Procedures
Issued 4 November 2003
Resolved
Provide annual testing results of automation.
Engineering › Fuel Oil Service System
Issued 4 November 2003
Resolved
Repair fuel leak on engine room fuel oil pump. LEGACY COMPONENT DESC: Fuel oil pump
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 4 November 2003
Resolved
Provide operational oily water separator
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 4 November 2003
Resolved
Make repairs to fire detection system.
Lifesaving › Lifebuoys
Issued 4 November 2003
Resolved
Stencil and renew retro reflective tape on all deck life rings. LEGACY COMPONENT DESC: Markings (ship name/port)
Pollution Prevention/Response › Prevention Equipment
Issued 4 November 2003
Resolved
Repair hydraulic oil leak on bow thruster oil centrifuge. LEGACY COMPONENT DESC: oil leak
Engineering › Generator (propulsion/auxiliary-electric)
Issued 4 November 2003
Resolved
Repair over speeds on both ships service generators. LEGACY COMPONENT DESC: Over speed device
Stability › Watertight Integrity
Issued 4 November 2003
Resolved
Adjust dogs on watertight door leading into engine room. LEGACY COMPONENT DESC: Watertight door
Communications › Alarms/Indicators › General Alarm
Issued 4 November 2003
Resolved
Make repairs to general alarm contactor at the control booth location.
Stability › Watertight Integrity
Issued 4 November 2003
Resolved
Renew gaskets on watertight doors near #6 ballast tank and #5 fire station. LEGACY COMPONENT DESC: Watertight doors
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 29 October 2002
Resolved
PROVIDE LIQUID MUD AND FUEL OIL TRANSFER PROCEDURES.
Pollution Prevention/Response › Prevention Equipment
Issued 29 October 2002
Resolved
REPAIR MAIN DECK REMOTE STOPS. LEGACY COMPONENT DESC: REMOTE STOPS
Electrical › Electrical Distribution System (emergency)
Issued 29 October 2002
Resolved
PROVIDE PROPER LOCATION FOR STOWAGE AND CHARGING OF BATTERIES LOCATED IN 02 LEVEL A/C SPACE. LEGACY COMPONENT DESC: BATTERY INSTALLATION
Casualty record · 2
24 February 2015Routine · role: Involved in a Marine Casualty · activity 5845410
25 February 2015Routine · role: Involved in a Marine Casualty · activity 5845445
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.