Records from 1985 to 2015. Most recent: inspection, 4 November 2015.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 36
4 November 2015
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5757553
22 October 2014
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5018320
25 March 2014
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4826136
24 July 2012
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4392425
17 May 2012
Administrative Inspection
Administrative · Outer Continental Shelf National Center of Expertise · Activity 4313971
12 October 2007
Load Line/Change of Employment
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3078438
11 February 2004
Administrative Inspection
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2005050
11 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1963096
18 September 2001
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1071104
22 September 2000
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 822818
6 September 2000
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 822229
7 February 2000
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1045691
10 September 1999
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1395265
24 March 1999
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 795188
26 August 1998
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1398948
4 September 1997
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1121680
13 September 1996
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1388137
7 July 1995
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1360189
1 June 1994
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1171856
25 May 1994
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1170129
5 May 1994
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1450847
8 July 1993
Hull Examination · COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1442042
21 December 1992
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 827382
2 December 1992
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1141975
19 November 1992
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1379722
8 August 1991
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 942901
18 July 1991
Hull Examination · COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1250260
11 January 1991
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 907030
7 November 1990
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 923169
10 October 1989
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1028635
31 October 1988
Hull Examination · COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1205173
27 January 1988
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1015709
13 January 1988
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1318308
19 June 1987
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1312348
24 April 1987
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1024064
20 June 1985
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 988836
Documentation
Issued 26 August 1998
Resolved
PROVIDE OIL TRANSFER PROCEDURES IAW 33 CFR PRIOR TO OPERATION.
Condition: Unknown
Due 10 September 2001
Resolved 26 November 2002
Resolution: Vessel no longer in certificated service.
Electrical
Issued 26 August 1998
Resolved
PERMANENTLY REPLACE DECK LIGHTS ON FORWARD HOUSE PRIOR TO OPERATION.
Condition: Unknown
Due 10 September 2001
Resolved 26 November 2002
Resolution: Vessel no longer in certificated service.
Documentation
Issued 26 August 1998
Resolved
PROVIDE VALID ABS LOADLINE CERTIFICATE PRIOR TO OPERATION.
Condition: Unknown
Due 10 September 2001
Resolved 26 November 2002
Resolution: Vessel no longer in certificated service.
Navigation
Issued 26 August 1998
Resolved
PROVIDE NAVIGATION LIGHTS PRIOR TO NIGHT OPERATIONS.
Condition: Unknown
Due 10 September 2001
Resolved 26 November 2002
Resolution: Vessel no longer in certificated service.
Documentation
Issued 26 August 1998
Resolved
PROVIDE VALID IOPP CERTIFICATE PRIOR TO OPERATION.
Condition: Unknown
Due 10 September 2001
Resolved 26 November 2002
Resolution: Vessel no longer in certificated service.
Fire Fighting
Issued 26 August 1998
Resolved
SERVICE ALL PORTABLE FIRE EXTINGUISHERS PRIOR TO OPERATION.
Condition: Unknown
Due 10 September 2001
Resolved 26 November 2002
Resolution: Vessel no longer in certificated service.
Documentation
Issued 26 August 1998
Resolved
COMPLETE DRYDOCK, INTERNAL STRUCTURAL, AND CARGO TANK INTERNAL INSPECTIONS PRIOR TO OPERATION.
Condition: Unknown
Due 10 September 2001
Resolved 26 November 2002
Resolution: Vessel no longer in certificated service.
Deck/Cargo
Issued 26 August 1998
Resolved
CONDUCT OPERATIONAL TEST OF CARGO PUMP ENGINE AND REMOTE SHUTDOWN PRIOR TO OPERATION.
Condition: Unknown
Due 10 September 2001
Resolved 26 November 2002
Resolution: Vessel no longer in certificated service.
Deck/Cargo
Issued 26 August 1998
Resolved
CONDUCT HYDROSTATIC TEST OF CARGO PIPING AND RELIEF VALVE PRIOR TO OPERATION.
Condition: Unknown
Due 10 September 2001
Resolved 26 November 2002
Resolution: Vessel no longer in certificated service.
Deck/Cargo
Issued 13 September 1996
Resolved
CONDUCT OPERATIONAL TEST OF CARGO PUMP ENGINE AND REMOTE SHUTDOWN, PRIOR TOOPERATION.
Condition: Unknown
Due 13 September 1996
Resolved 13 September 1996
Documentation
Issued 13 September 1996
Resolved
PROVIDE VALID ABS LOADLINE CERTIFICATE, PRIOR TO OPERATION.
Condition: Unknown
Due 13 September 1996
Resolved 13 September 1996
Navigation
Issued 13 September 1996
Resolved
PROVIDE NAVIGATION RUNNING LIGHTS, PRIOR TO NIGHT OPERATIONS._x001C_
Condition: Unknown
Due 13 September 1996
Resolved 13 September 1996
Fire Fighting
Issued 13 September 1996
Resolved
SERVICE ALL PORTABLE FIRE EXTINGUISHERS, PRIOR TO PLACING BARGE IN SERVICE.
Condition: Unknown
Due 13 September 1996
Resolved 13 September 1996
Construction/Loadline
Issued 13 September 1996
Resolved
PER FACSIMILE DATE 12SEP96, PRIOR TO OPERATION, DRYDOCK VESSEL.
Condition: Unknown
Due 13 September 1996
Resolved 13 September 1996
Deck/Cargo
Issued 13 September 1996
Resolved
CONDUCT HYDROSTATIC TEST OF CARGO PIPING AND RELIEF VALVE, PRIOR TO OPERATION.
Condition: Unknown
Due 13 September 1996
Resolved 13 September 1996
Deck/Cargo
Issued 13 September 1996
Resolved
PROVIDE OIL TRANSFER PROCEDURES IAW 33 CFR, PRIOR TO OPERATION.
Condition: Unknown
Due 13 September 1996
Resolved 13 September 1996
Electrical
Issued 13 September 1996
Resolved
PERMANENTLY REPLACE DECK LIGHTS ON FORWARD HOUSE, PRIOR TO OPERATION.
Condition: Unknown
Due 13 September 1996
Resolved 13 September 1996
Deck/Cargo
Issued 7 July 1995
Resolved
Conduct hydrostatic test of cargo piping and relief valve, prior to placingbarge in service, but not later than 07JUL96._x001C_
Condition: Unknown
Due 7 July 1995
Resolved 7 July 1995
Deck/Cargo
Issued 7 July 1995
Resolved
Provide oil transfer procedures IAW 33 CFR, prior to placing barge in service, but not later than 07JUL96._x001C_
Condition: Unknown
Due 7 July 1995
Resolved 7 July 1995
Electrical
Issued 7 July 1995
Resolved
Permanently replace deck lights on forward house, prior to placing barge inservice, but not later than 07JUL96._x001C_
Condition: Unknown
Due 7 July 1995
Resolved 7 July 1995
Documentation
Issued 7 July 1995
Resolved
Provide valid Certificate of Financial Responsibility, prior to placing barge in service, but not later than 07JUL96._x001C_
Condition: Unknown
Due 7 July 1995
Resolved 7 July 1995
Fire Fighting
Issued 7 July 1995
Resolved
Provide proof of annual servicing of all portable fire extinguishers, priorto placing barge in service, but not later than 07 JUL 1996.
Condition: Unknown
Due 7 July 1995
Resolved 7 July 1995
Deck/Cargo
Issued 7 July 1995
Resolved
Conduct operational test of cargo pump engine and remote shutdown, prior toplacing barge in service, but not later than 07JUL96._x001C_
Condition: Unknown
Due 7 July 1995
Resolved 7 July 1995
Deck/Cargo
Issued 5 May 1994
Resolved
Provide cargo pump emergency shutdown in accordance with 33 CFR 155.780 andtest to the satisfaction of the attending marine inspector. No cargo shallbe carried until this item is completed.
Condition: Unknown
Due 5 May 1994
Resolved 5 May 1994
Deck/Cargo
Issued 5 May 1994
Resolved
Drain fixed cargo containment of water/oil mixture in accordance with 33CFR156.120(n). No cargo shall be carried until this item is completed tothe satisfaction of the attending marine inspector.
Condition: Unknown
Due 5 May 1994
Resolved 5 May 1994
Fire Fighting
Issued 5 May 1994
Resolved
Provide proof of annual servicing of three B-II type fire extinguishers. No cargo shall be carried until this item is completed to the satisfaction of the attending marine inspector.
Condition: Unknown
Due 5 May 1994
Resolved 5 May 1994
Deck/Cargo
Issued 21 December 1992
Resolved
TEST CARGO PUMP RELIEF VALVE, PRIOR TO PLACING THE BARGE IN SERVICE OR AT NEXT DRYDOCKING, BUT NOT LATER THAN 31 OCTOBER 1993.
Condition: Unknown
Due 21 December 1992
Resolved 21 December 1992
Deck/Cargo
Issued 21 December 1992
Resolved
HYDRO CARGO DISCHARGE PIPING, PRIOR TO PLACING THE BARGE IN SERVICE OR AT NEXT DRYDOCKING, BUT NOT LATER THAN 31 OCTOBER 1993.
Condition: Unknown
Due 21 December 1992
Resolved 21 December 1992
Deck/Cargo
Issued 21 December 1992
Resolved
CONDUCT OPERATIONAL TEST OF CARGO PUMP ENGINE AND REMOTE SHUT DOWN, PRIOR_x001C_ TO PLACING THE BARGE IN SERVICE OR AT NEXT DRYDOCKING, BUT NOT LATER THAN_x001C_ 31 OCTOBER 1993.
Condition: Unknown
Due 21 December 1992
Resolved 21 December 1992
Deck/Cargo
Issued 19 November 1992
Resolved
CONDUCT OPERATIONAL TEST OF CARGO PUMP ENGINE AND REMOTE SHUT DOWN.
Condition: Unknown
Due 19 November 1992
Resolved 19 November 1992
Deck/Cargo
Issued 19 November 1992
Resolved
HYDRO CARGO DISCHARGE PIPING.
Condition: Unknown
Due 19 November 1992
Resolved 19 November 1992
Deck/Cargo
Issued 19 November 1992
Resolved
TEST CARGO PUMP RELIEF VALVE.
Condition: Unknown
Due 19 November 1992
Resolved 19 November 1992
Deck/Cargo
Issued 24 April 1987
Resolved
PROVE PROPER OPERATION OF ALL VESSEL MACHINERY IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 24 April 1987
Resolved 24 April 1987
Navigation
Issued 20 June 1985
Resolved
LOADING AND ANCHOR LIGHTS MISSING FROM MAST ATOP TOWER MUST BE REPLACED. THIS DEFICIENCY WAS TO HAVE BEEN CORRECTED BY 15 JULY 1985.
Condition: Unknown
Due 20 June 1985
Resolved 20 June 1985
Electrical
Issued 20 June 1985
Resolved
LOOSE WIRING IN TOWER MUST BE UTILIZED OR DEAD ENDED. THIS DEFICIENCY WAS TO HAVE BEEN CORRECTED BY 15 JULY 1985.
Condition: Unknown
Due 20 June 1985
Resolved 20 June 1985