11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 18 August 2025
Resolved
Each vessel certificated to operate on an oceans route in cold water must: be provided with IBA of an aggregate capacity that will accommodate at least 100% of the total number of persons permitted onboard:
IBA is being serviced and a spare may not be available to complement vessel's required life saving equipment. Vessel still has one serviced 30 person IBA. While vessel is not outfitted with a serviceable IBA
, vessel is not to carry more than 30 persons onboard.
46 CFR 180.202(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 August 2025
Resolved 12 August 2026
Resolution: IBA was serviced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 August 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to: protect passengers, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock.
The battery charger on the port side of the engine room is connected via extension cord running over the port main engine to an overhead electrical outlet. Make permanent connection to satisfaction of attending Marine Inspector.
46 CFR 183.200(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 September 2025
Resolved 25 August 2025
Resolution: Received photos of properly installed battery charger.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 18 September 2023
Resolved
Each entrance to a space storing carbon dioxide cylinders, a space protected by carbon dioxide systems, or any space into which carbon dioxide might migrate must be conspicuously marked as follows: Spaces protected by carbon dioxide—“CARBON DIOXIDE GAS CAN CAUSE INJURY OR DEATH. WHEN ALARM OPERATES OR WINTERGREEN SCENT IS DETECTED, DO NOT ENTER UNTIL VENTILATED. LOCK OUT SYSTEM WHEN SERVICING.” The reference to wintergreen scent may be omitted for carbon dioxide systems not required to have odorizing units and not equipped with such units. The machinery space protected by CO2 was not conspicuously marked with warning. 46 CFR 185.612(g)(2)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 October 2023
Resolved 6 October 2023
Resolution: Received photos of proper signage.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 September 2023
Resolved
Electrical equipment exposed to the weather must be watertight. Stbd bridge wing electrical junction box was missing cover. 46 CFR 180.210(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 October 2023
Resolved 6 October 2023
Resolution: Received photos of working stern light.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 18 September 2023
Resolved
Each survival craft must be: Stowed so that when the vessel sinks the survival craft floats free and, if inflatable, inflates automatically. IBA sea painter was not attached to weak link. 46 CFR 180.130(a)(2)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 18 September 2023
Resolution: IBA sea painter was properly installed on site.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 29 November 2022
Resolved
Each disposable hydrostatic release unit (HRU) must be
marked with an expiration date of two years after the
date on which the unit is installed. Markings on
vessel's IBA HRU appeared expired. Replace with properly
marked/installed HRU to manufacturer specifications, or
prove validity of HRU currently installed. Make
satisfactory to attending Marine Inspector.
Action required: 10 - Deficiency Rectified
Resolved 29 November 2022
Resolution: Made satisfactory to attending Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 29 November 2022
Resolved
A vessel must be provided with a satisfactory
arrangement for draining any watertight compartment,
other than small buoyancy compartments, under all
practicable conditions. Vessel was not able to de-water
lazarette bilge with installed bilge system due to
obstructed pick-up. Make and maintain bilge system in
compliance with regulations and to satisfaction of
attending Marine Inspector.
Action required: 10 - Deficiency Rectified
Resolved 29 November 2022
Resolution: Made bilge system in compliance with regulations and to satisfaction of attending Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 November 2022
Resolved
At each inspection, spaces may be examined to see that
there is no excessive accumulation debris, or other
matter that might create a fire hazard. Paint and FRP
repair items were being stored below deck. Remove all
items that might create a fire hazard to the
satisfaction of attending Marine Inspector.
Action required: 10 - Deficiency Rectified
Resolved 29 November 2022
Resolution: Removed all items that might create a fire hazard to the satisfaction of attending Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 November 2022
Resolved
Each life jacket carried on a vessel on an oceans
route, must have a life jacket light approved in accordance with § 161.012 in subchapter Q of this
chapter, or other standard specified by the
Commandant, including, but not limited to, approval
series 160.112. 02 life jacket lights were not
operable. Vessel must make life jackets in compliance to
the satisfaction of attending Marine Inspector.
Action required: 10 - Deficiency Rectified
Resolved 29 November 2022
Resolution: Vessel made life jackets in compliance to the satisfaction of attending Marine Inspector.
10 - Safety of Navigation › N/A - No Subsystem › Electronic charts (ECDIS)
Issued 29 November 2022
Resolved
As appropriate for the intended voyage, a vessel must
carry adequate and up-to-date: U.S. Coast Pilot or
similar publication; Coast Guard Light List; Tide
tables; and Current tables. Vessel did not have
electronic versions or hard copies of some of these
publications. If vessel intends to use electronic
versions of these publications they must be downloaded
for immediate use.
Action required: 10 - Deficiency Rectified
Resolved 29 November 2022
Resolution: Vessel intends to use electronic versions of these publications and downloaded them for immediate use.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 November 2022
Resolved
The fuel shutoff valve at the tank must be manually
operable from outside the compartment in which the valve
is located. Fuel shut off from outside the compartment
was unsat. Make satisfactory and test to satisfaction of
attending Marine Inspector.
Action required: 10 - Deficiency Rectified
Resolved 29 November 2022
Resolution: Made satisfactory and tested to satisfaction of attending Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 29 November 2022
Resolved
Emergency egress training for each member of the crew
must occur at least monthly. Crew training shall be
logged or otherwise documented for review by the Coast
Guard upon request. The training entry shall include
date of the training; and general description of the
training topics. Begin logging and conducting training
as required.
Action required: 10 - Deficiency Rectified
Resolved 29 November 2022
Resolution: Have begun logging and conducting training as required.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 March 2022
Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Raw water pump assembly in engine room was held up by bungee cords and needs to be properly mounted/secured.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 April 2022
Resolved 25 March 2022
Resolution: Water pump was remounted. All SAT.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 3 March 2022
Resolved
Rails or equivalent protection shall be installed near periphery of all weather decks accessible to passengers and crews. Several rails and supports were cracked or corroded.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 April 2022
Resolved 25 March 2022
Resolution: All cracked/corroded railings were repaired or replaced.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 March 2022
Resolved
If the handle to the shutoff valve at the tank is located inside the machinery space, it must be located so that the operator does not have to reach more than 12 inches into the space and the valve handle must be
shielded from flames. Flame shields are corroded, worn,
and need replacing.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 April 2022
Resolved 25 March 2022
Resolution: Operator sent photos of new flame screen installation. All sat
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 1 November 2021
Resolved
The Rules concerning lights shall be complied with from
sunset to sunrise, and if carried, also be exhibited
from sunrise to sunset in restricted visibility.
Required Mast head light extinguished. Make satisfactory
to regulations and to the satisfaction of attending
Marine Inspector (MI).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 November 2021
Resolution: Vessel replaced mast head light.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 1 November 2021
Resolved
Each vessel that operates on the high seas must have on
board an FCC Type Accepted Category 1, 406 MHz EPIRB,
installed to automatically float free and activate.
Vessels EPIRB was found with an expired battery. Make
EPIRB operational as per regulations and to the
satisfaction of the attending Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 November 2021
Resolution: Vessel replaced EPIRB.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 1 November 2021
Resolved
Every vessel must be fitted with a suitable magnetic
compass designed for marine use, to be mounted at the
primary operating station. Vessel's magnetic compass was
determined to be off course by attending Marine Inspector. Have compass corrected to satisfaction of attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 November 2021
Resolved 3 November 2021
Resolution: Vessel completed new deviation card.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 November 2021
Resolved
Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10.Monthly inspections required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or a designate member of the crew. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. Evidence was not available to show compliance with this regulation. Complete required inspections and provide attending Marine Inspector with record of monthly inspections.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 November 2021
Resolved 18 November 2021
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 1 November 2021
Resolved
As appropriate for the intended voyage, a vessel must
carry adequate and up-to-date: U.S. Coast Pilot or
similar publication; Coast Guard Light List; tide
tables; and current tables. Publications were not
available for inspection. Make publications available to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 November 2021
Resolved 18 November 2021
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 1 November 2021
Resolved
The Rules concerning shapes shall be complied with by day. Vessel's day shapes were either not serviceable or missing. Make to the satisfaction of attending Marine Inspector and as required by regulation.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 November 2021
Resolved 18 November 2021
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 1 November 2021
Resolved
The inspection and maintenance of survival craft manufactured on or after March 11, 1996, shall be logged or otherwise documented for review by the Coast Guard upon request. Servicing certificates for IBA's were not available for review. Provide servicing certificates for review by attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 November 2021
Resolved 5 November 2021
Resolution: Vessel provided servicing certificates.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 November 2021
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. Child size life jackets were not stowed separately. Stow child size life jackets in accordance with regulations.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 November 2021
Resolved 18 November 2021
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 1 November 2021
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. Eye wash and aspirin were expired. Replace expired items.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 November 2021
Resolved 18 November 2021
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 1 November 2021
Resolved
Machinery and fuel tank spaces must be separated from accommodation spaces by boundaries that prevent the passage of vapors. Wire penetration found above above the door separating machinery and accommodation spaces was not vapor tight. Make penetration vapor tight to the satisfaction of attending Marine Inspector.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 November 2021
Resolved 18 November 2021
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 1 November 2021
Resolved
Electrical equipment on a vessel must be installed and
maintained to protect passengers, crew, other persons,
and the vessel from electrical hazards, including fire,
caused by or originating in electrical equipment, and
electrical shock. Light in bunk-room needs a cover. Aft deck lights need junction boxes. Correct to the satisfaction of attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 November 2021
Resolved 18 November 2021
10 - Safety of Navigation › N/A - No Subsystem › Voyage or passage plan
Issued 1 November 2021
Resolved
The master of a vessel making an oceans voyage shall prepare a voyage plan. Vessel master was not preparing voyage plans as required. Moving forward, the vessel's Master shall prepare a voyage plan as required.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 1 November 2021
Resolved 1 November 2021
Resolution: Vessel made plans to prepare voyage plans.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 1 November 2021
Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI. Alcohol swabs expired. Correct in accordance with regulations and to the satisfaction of attending MI
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 November 2021
Resolved 18 November 2021
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 18 August 2020
Resolved
Permanent extension cords found in galley and engine room. Remove extension cords and hard wire if necessary.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 September 2020
Resolved 15 September 2020
Resolution: Permanent extension cords removed. Vessel extended galley outlet and unpolugged battery charger in engine room.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 18 August 2020
Resolved
Provide missing covers for light fixtures in bunk/store room.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 September 2020
Resolved 15 September 2020
Resolution: Vessel provided light fixture covers.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 18 August 2020
Resolved
Exposed wire nuts found on power conducting circuits in engine room vestibule and lazarette. Wire nuts are permitted only when prevented from backing off and when within a protective enclosure. Provide proper connections.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 September 2020
Resolved 15 September 2020
Resolution: Vessel removed wire nuts and made proper crimp type connections.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 August 2020
Resolved
Ring buoy water light clip seized. Provide functioning corrosion resistant clip.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 September 2020
Resolved 15 September 2020
Resolution: Vessel provided new ring buoy clip.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 17 August 2020
Resolved
Rudder posts found leaking seawater. Tighten rudder packing.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 September 2020
Resolved 15 September 2020
Resolution: Vessel tightened rudder packing.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 20 November 2019
Resolved
Provide VHF DSC radio programmed with current MMSI number.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 December 2019
Resolved 19 December 2019
Resolution: Vessel provided DSC VHF programmed with correct MMSI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 November 2018
Resolved
Prove proper operation of the bilge system.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 November 2018
Resolved 29 November 2018
Resolution: Bilge system operating properly.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 27 November 2018
Resolved
Replace hydraulic hose fittings (x2) at steering ram.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 December 2018
Resolved 11 December 2018
Resolution: Hydraulic hose fittings replaced and tested sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 27 November 2018
Resolved
Repair/tighten top railing on deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 December 2018
Resolved 11 December 2018
Resolution: Top railings repaired/tightened.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 November 2018
Resolved
Renew alcohol test strips by 31DEC2018.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 December 2018
Resolved 11 December 2018
Resolution: Alcohol test strips renewed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 18 October 2018
Resolved
Prove proper operation of the new genset prior to use.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 October 2018
Resolved 25 October 2018
Resolution: Genset tested sat.
Construction/Loadline › Structures › Machinery Space Opening
Issued 16 November 2017
Resolved
Improve air tightness of E/R door.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 December 2017
Resolved 20 December 2017
Resolution: Air tightness is improved.
Fire Fighting › Means of Escape › Doorways
Issued 16 November 2017
Resolved
Install interior door handle on E/R door to allow emergency exit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 December 2017
Resolved 20 December 2017
Resolution: Door handle installed.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 16 November 2017
Resolved
Tighten STBD rail stanchions.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 December 2017
Resolved 20 December 2017
Resolution: Rails are tightened.
Lifesaving › Hand Flares › Expired
Issued 16 November 2017
Resolved
Provide 01 red or orange flare.
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 December 2017
Resolved 20 December 2017
Resolution: 01 flare was provided.
Electrical › Electric Supply System (service) › Cable
Issued 16 November 2017
Resolved
Replace wire nuts with crimp connectors on auxiliary deck wash pump.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 16 November 2017
Resolved 16 November 2017
Resolution: Crimp connectors installed.
Electrical › Electric Generation Source (service) › Generator
Issued 5 January 2017
Resolved
Clean generator windings and assess generator/prime mover seal for possible replacement.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 February 2017
Resolved 23 March 2017
Electrical › Electric Supply System (service) › Battery Installation
Issued 5 January 2017
Resolved
Replace wing nuts on all battery terminals with locknuts or double-nut
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 February 2017
Resolved 23 March 2017
Electrical › Lighting (service) › Lighting Fixture
Issued 5 January 2017
Resolved
Bridge: install correct size bulb in overhead light fixture
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 February 2017
Resolved 23 March 2017
Electrical › Lighting (service) › Lighting Fixture
Issued 5 January 2017
Resolved
Overhead light at E/R door: install guard over bulb.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 5 February 2017
Resolved 23 March 2017
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 January 2017
Resolved
Ensure all overhead wiring in E/R is secured w/ metallic hangers at 24" intervals
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 5 February 2017
Resolved 23 March 2017
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 January 2017
Resolved
Remove identified dead-end wire in E/R.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 February 2017
Resolved 23 March 2017
Electrical › Electrical Distribution System (service) › Wiring
Issued 17 November 2016
Resolved
Install chafing gear around electrical wiring penetrating aft sonar bulkhead.
Action required: 705 - Other - as specified
Due 17 December 2016
Resolved 5 January 2017
Electrical › Electrical Distribution System (service) › Wiring
Issued 17 November 2016
Resolved
Identify and replace damaged wire stbd side in E/R.
Action required: 705 - Other - as specified
Due 17 December 2016
Resolved 5 January 2017
Electrical › Lighting (service) › Lighting Fixture
Issued 17 November 2016
Resolved
Relocate light fixture at aft accommodation space to allow weathertight door to close properly.
Action required: 705 - Other - as specified
Due 17 December 2016
Resolved 5 January 2017
Electrical › Electrical Distribution System (service) › Wiring
Issued 17 November 2016
Resolved
Install protective cover/sheating of genset wire harness.
Action required: 705 - Other - as specified
Due 17 December 2016
Resolved 5 January 2017
Electrical › Electrical Distribution System (service) › Grounding Conductor
Issued 17 November 2016
Resolved
Clean and renew bonding wire to stbd MDE keel cooler piping at 90 degree elbow.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 December 2016
Resolved 23 March 2017
Electrical › Lighting (service) › Lighting Fixture
Issued 17 November 2016
Resolved
Renew broken light fixture covers in forward berthing and main accommodation space.
Action required: 705 - Other - as specified
Due 17 December 2016
Resolved 5 January 2017
Electrical › Lighting (service) › Lighting Fixture
Issued 17 November 2016
Resolved
Install appropriate sized bulbs in light fixtures in forward berthing and accommodation spaces to prevent overheating.
Action required: 705 - Other - as specified
Due 17 December 2016
Resolved 5 January 2017
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 17 November 2016
Resolved
Provide annual service report for fixed CO2 system for the E/R, prior to sailing.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 November 2016
Resolved 18 November 2016
Resolution: FFF annual service report received.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 17 November 2016
Resolved
Install vent pipes for P/S MSD tanks.
Action required: 705 - Other - as specified
Due 17 December 2016
Resolved 18 November 2016
Resolution: Vent pipes installed on MSD tanks.
Engineering › Steering Gear System › Rudder Stock
Issued 17 November 2016
Resolved
Repair/service P/S rudder stock mounting to the hull at next drydock exam.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 January 2017
Resolved 23 March 2017
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 17 November 2016
Resolved
Replace cracked deck rail foot stbd aft.
Action required: 705 - Other - as specified
Due 17 December 2016
Resolved 5 January 2017
Personnel › Certificates/Documents/Licenses › License, GMDSS Radio Operator
Issued 17 November 2016
Resolved
Provide copy of FCC Marine Operators Permit for [name withheld].
Action required: 705 - Other - as specified
Due 17 December 2016
Resolved 5 January 2017
Documentation › Certificates/Documents › FCC SSL
Issued 17 November 2016
Resolved
Renew FCC ships station license with new name of the vessel (AVENGER).
Action required: 705 - Other - as specified
Due 17 December 2016
Resolved 5 January 2017
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 13 November 2016
Resolved
Repair/replace port MSD tank.
Action required: 705 - Other - as specified
Due 30 November 2016
Resolved 18 November 2016
Resolution: New MSD tank installed.
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 13 November 2016
Resolved
Repair portside toilet to flush on-demand.
Action required: 705 - Other - as specified
Due 30 November 2016
Resolved 5 January 2017
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 13 November 2016
Resolved
Remove standing water from all voids for further inspection.
Action required: 705 - Other - as specified
Due 30 November 2016
Resolved 17 November 2016
Fire Fighting › Remote Fuel Shutoff › General
Issued 13 November 2016
Resolved
Renew P/S fuel shut-off reach rods in the laz.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 November 2016
Resolved 17 November 2016
Resolution: Reach rods replaced and tested sat.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 13 November 2016
Resolved
Replace fractured securing arm on laz hatch cover.
Action required: 705 - Other - as specified
Due 30 November 2016
Resolved 17 November 2016
Resolution: Replacement hatch installed.
Engineering › Steering Gear System › Rudder Stock
Issued 13 November 2016
Resolved
Tighten P/S rudder post packing.
Action required: 705 - Other - as specified
Due 30 November 2016
Resolved 17 November 2016