Records from 2016 to 2022. Most recent: inspection, 20 April 2022.
Documentation record
Registered dimensions (L × B × D)36.0 ft × 13.1 ft × 4.5 ft
Registered tonnagegross 12 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMILLER'S MARINE RAILWAY · DELTAVILLE, VA, UNITED STATES · built 1976
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portDELTAVILLE, VA
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it12 - Regulatory (Subpart C or D), Gross Ton
10 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 12
20 April 2022
Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7434404
1 June 2021
Annual Inspection · Administrative Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7211647
2 July 2020
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6986671
3 June 2020
Deficiency Check · Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6965604
2 May 2019
COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6686397
19 April 2019
Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6664160
11 May 2018
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6420311
2 May 2018
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6402945
10 May 2017
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6145101
1 May 2017
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6136750
18 April 2017
Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6126662
9 May 2016
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5868096
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 1 June 2021
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible. Vessel did not have nautical charts onboard.
Action required: 10 - Deficiency Rectified
Resolved 1 June 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 July 2020
Resolved
Each ring life buoy must have a lanyard securing the water light around the body of the ring life buoy. The lanyard is wasted. Replace lanyard to the satisfaction of the Coast Guard Marine Inspector.
46CFR180.70(d)(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 August 2020
Resolved 17 August 2020
Resolution: Ring buoy lanyard was replaced.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 2 July 2020
Resolved
Vessel must comply with FCC requirements for state license. Vessel's Safety Radio Certificate is expired.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 August 2020
Resolved 17 August 2020
Resolution: Vessel obtained new FCC Safety Radio Certificate.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 2 July 2020
Resolved
Master was unable to retrieve mannequin from the water. Master shall conduct man overboard drill to the satisfaction of the Coast Guard Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 August 2020
Resolved 17 August 2020
Resolution: Master installed pulley system and successfully completed man overboard drill in the presence of the Coast Guard Marine Inspector.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 3 June 2020
Resolved
Replace 4 chine log bolts port side in way of head as marked to the satisfaction of Coast Guard Marine Inspector.
Action required: 705 - Other - as specified
Due 1 July 2020
Resolved 2 July 2020
Resolution: 4 Chine Log Bolts replaced to the satisfaction of Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 May 2019
Resolved
08 lifejackets were found in a deteriorated condition leaving only 10 servicable life jackets onboard. Total persons on baored is restricted to 10 persons.
46CFR180.71(a)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 16 May 2019
Resolution: owner procured new lifejackets. Inspected SAT
Personnel › Training › First Aid/CPR
Issued 2 May 2018
Resolved
Vessel's Master did not have current CPR training. IAW local policy, to operate as single operator, operator shall be certified in CPR. Inspection Note 14.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 June 2018
Resolved 15 June 2018
Resolution: Received evidence of CPR/ First Aid Training through American Heart Association.
Navigation › Piloting/Steering › US Coast Pilot
Issued 2 May 2018
Resolved
Vessel holds 2014 US Coast Pilot. Vessel must carry up to date US Coast Pilot.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 June 2018
Resolved 11 May 2018
Resolution: Vessel purchased 2018 US Coast Pilot.
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 2 May 2018
Resolved
Vessel's sewage vent pipe was disconnected from vent. All Toilets shall be fitted with adequate plumbing. 46 CFR 177.30-5 - OLD T.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 June 2018
Resolved 11 May 2018
Resolution: Vessel's sewage vent pipe was reconnected to vent.
Electrical › Lighting (service) › Lighting Fixture
Issued 2 May 2018
Resolved
Vessel missing bulb in port side crew space. Add bulb and cover, or remove fixture. 46 CFR 183.10-20(a) - Old T.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 June 2018
Resolved 11 May 2018
Resolution: Vessel operator removed light fixture and all associated wiring.
Engineering › Bilge Water Management System › Not Operational
Issued 1 May 2017
Resolved
Found Portable hand bilge pump was inoperable. Make operable or replace in kind. 46 OLD CFR 182.25 (a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 May 2017
Resolved 10 May 2017
Resolution: Vessel's owner has purchased and demonstrated operation of new Portable hand bilge pump.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 1 May 2017
Resolved
Vessel does not have updated charts. Provide up updated charts for vessels AOR.
Condition: Invalid
Due 14 May 2017
Resolved 10 May 2017
Resolution: Vessel has updated charts for AOR.