MAURY USCG vessel records Sign in
← All vessels

DANA LEE

DANA LEE is a 1976 commercial fishing vessel. The Coast Guard has recorded 78 inspections since 1985, most recently in June 2023, along with 188 deficiencies, 2 operational controls and 1 casualty investigation in 2004.

Records from 1985 to 2023. Most recent: inspection, 27 June 2023.

Built
1976
Last inspected
27 June 2023
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDQ4267
Flag
UNITED STATES
368136990, 368424030
Maury page id
psix-48793

Inspections, by type

…with no type recorded16
Years with a record 34 calendar years (1985–2023)
The 78 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Fishing Vessel class in Maury's sources begin in 1972.

Documentation record

Registered dimensions (L × B × D)48.0 ft × 15.7 ft × 6.7 ft
Registered tonnagegross 37 / net 28
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDELTA MARINE INDUSTRIES · SEATTLE, WA, UNITED STATES · built 1976
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portVENICE, CA
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational, Registry
DocumentationValid · issued 1 April 2026 · expires 31 March 2027
Service, as the file records itCommercial Fishing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it37 - Regulatory (Subpart C or D), Gross Ton
28 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDQ4267MMSI 368424030 · active · voluntarily equipped · granted 12 June 2025, expires 12 June 2035
WDL5006MMSI 368136990 · active · compulsorily equipped · granted 11 March 2020, expires 11 March 2030 · licensed under a name not among this hull’s recorded names (not shown)
WDI8111MMSI 367735380 · expired · compulsorily equipped · granted 20 May 2016, cancelled 27 June 2026 · licensed under a name not among this hull’s recorded names (not shown)
EX164MMSI 367119610 · expired · exemption · granted 26 July 2013, cancelled 6 August 2016 · licensed under a name not among this hull’s recorded names (not shown)
WDD2765MMSI 367119610 · expired · compulsorily equipped · granted 6 June 2006, cancelled 6 August 2016 · licensed under a name not among this hull’s recorded names (not shown)
WCX3700MMSI not assigned · expired · compulsorily equipped · granted 2 April 1997, cancelled 3 June 2007
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 78

27 June 2023 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7725016
15 May 2022 Type not recorded
No type recorded · USCGC BLACKFIN (WPB 87317) · USCG Southwest District (CGD-SW) · Activity 7459855
28 March 2022 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7433302
10 February 2022 Internal Structural Exam · Drydock Exam · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7389309
2 September 2021 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7302967
25 February 2021 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7146401
14 January 2020 COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6889588
11 December 2019 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6889169
22 October 2019 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6819300
12 December 2018 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6592348
6 February 2018 Hull Examination · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6339341
17 November 2017 Type not recorded
No type recorded · USCGC MUNRO (WMSL 755) · Activity 6312263
8 November 2017 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6269495
16 September 2016 COI Inspection · DAPI Audit
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5931525
2 June 2016 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5886952
9 May 2016 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5865784
24 September 2015 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5235259
15 December 2011 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4209821
1 December 2011 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4203691
26 September 2011 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4144002
9 December 2010 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3938847
28 July 2009 Deficiency Check · DAPI Audit
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3549005
21 December 2007 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3120976
19 November 2007 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3100702
13 March 2007 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2887452
10 August 2006 Simplified Stability Test
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2756585
10 July 2006 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2690943
3 January 2005 Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2263314
10 December 2004 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2257172
2 July 2004 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2201305
1 April 2004 COI Inspection · Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2025885
26 March 2004 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2032073
15 March 2004 Administrative Inspection
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2024841
11 March 2004 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2026761
12 December 2002 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1717763
17 June 2002 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1632240
22 May 2002 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1619659
4 September 2001 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1410650
14 May 2001 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1399657
6 February 2001 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1376705
7 June 2000 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 230181
6 June 2000 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1391315
3 February 2000 Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 814427
3 December 1999 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 811579
4 November 1999 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1361220
25 September 1999 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 85742
18 June 1999 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 101186
1 June 1999 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1451406
10 March 1999 Plan Review "T" Boat
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 803196
15 December 1998 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1406413
12 May 1998 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1468859
12 June 1997 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1398706
3 June 1997 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 775681
19 December 1996 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1360690
3 July 1996 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1413017
10 April 1996 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1447564
15 May 1995 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1363285
18 June 1994 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 34126
13 April 1994 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1356625
4 June 1993 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1407164
14 May 1992 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1356123
2 March 1992 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1357923
22 May 1991 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1231662
16 May 1991 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1233483
20 September 1990 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1242197
8 June 1990 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1215922
16 May 1990 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 921793
26 January 1990 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1223381
5 December 1989 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1216792
2 October 1989 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1329826
4 May 1989 Re-Inspection · Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 898380
18 May 1988 COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1196775
2 November 1987 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1019887
6 May 1987 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1024228
21 July 1986 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1005207
4 June 1986 Credit Drydock
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1312895
13 June 1985 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 981639
10 May 1985 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1295331

Deficiency record · 188

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 10 February 2022 Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel overdue on dry dock exam dated 11Dec2021. Vessel is scheduled for exam on 10Mar2022. vessel can not operate until credit drydock is received.
Action required: 17 - Rectify deficiencies prior to departure
Due 10 February 2022
Resolved 10 March 2022
Resolution: DDX/ISE completed by attending MI's.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 25 February 2021 Resolved
Vessel was short by 03 organge smoke flares and 02 red hand flares. Provide additional flares to have a minimum total of 06 red hand flares and 06 orange smoke flares.
Action required: 10 - Deficiency Rectified
Resolved 25 February 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 February 2021 Resolved
Vessel was short 01 adult lifejacket. Provide 01 additional adult lifejacket and mark with vessel's name and retroreflective tape.
Action required: 10 - Deficiency Rectified
Resolved 25 February 2021
Resolution: Replaced.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 25 February 2021 Resolved
Several of vessel's charts were out of date. Provide up to date charts appropriate to the vessel's route.
Action required: 10 - Deficiency Rectified
Resolved 25 February 2021
Resolution: Replaced.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 March 2020 Resolved
Provide information to crew on who the Designated Employee Representitive (DER) is. The DER is an employee authorized by the employer to take immediate action to remove employees from safety-sensitive duties, and to make required decisions in the testing and evaluation processes. The DER also receives test results and other communications for the employer.
Action required: 10 - Deficiency Rectified
Resolved 11 March 2020
Resolution: DER has been identified.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 March 2020 Resolved
Provide pre-employment drug testing for all crew and ensure they are on the vessels drug enrollment list.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 March 2020
Resolution: Crew drug tested and on consortium list.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 March 2020 Resolved
Provide a waste management plan.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 March 2020
Resolution: Waste management plan provided.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 11 March 2020 Resolved
Provide current chart for area,current Coast Pilot for San Diego, current light list, current tide table/currents.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 March 2020
Resolution: Charts and pubs provided.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 11 March 2020 Resolved
Make VHF radio DSC capable.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 March 2020
Resolution: VHF DSC radio installed.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 11 March 2020 Resolved
Provide emergency broadcast placard. CG will provide.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 March 2020
Resolution: Emergency broadcast placard provided.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 11 March 2020 Resolved
Make signage for pre-engineered fire fighting pull cable.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 March 2020
Resolution: Signage provided.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 11 March 2020 Resolved
Provide UL 217 fire detector in galley.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 March 2020
Resolution: Detector placed in galley.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 11 March 2020 Resolved
Make both port and starboard mechanical and digital cooling temp gauges operational at helm station.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 March 2020
Resolution: Gauges replaced and working
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 March 2020 Resolved
Sector San Diego does not have vessels electrical plans on file. Provide a one-line electrical drawing for all A/C switchboards and distribution panels. Include all circuit loads, conductor sizes, over current protection, and max panel ratings in amps.
Action required: 705 - Other - as specified
Due 11 June 2020
Resolved 13 March 2020
Resolution: Electrical drawing provided.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 October 2019 Resolved
All matresses must comply or meet US Dept of Commerce FF 4-72.16, 16 CFR 1632 or IMO Res. A688(17). Matresses are custom built made of vinyl.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 November 2019
Resolved 14 August 2020
Resolution: To be addressed at DDX NLT 11Dec2021. Special note added.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 December 2018 Resolved
Prove proper operation of port alternator prior to operating with passengers.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 December 2018
Resolved 14 December 2018
Resolution: Replaced alternator, all sat.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 12 December 2018 Resolved
Provide service tag for fire extinguisher on deck.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 January 2019
Resolved 12 December 2018
Resolution: Service tag provided.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 December 2018 Resolved
Provide variable nozzle for fire hose.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 January 2019
Resolved 12 December 2018
Resolution: Nozzle provided.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 12 December 2018 Resolved
Properly mark remote fuel shut-off valves.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 January 2019
Resolved 12 December 2018
Resolution: Valves marked.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 12 December 2018 Resolved
Replace gasket on fire damper.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 January 2019
Resolved 12 December 2018
Resolution: Gasket replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 December 2018 Resolved
Replace 01 adult lifejacket for a total of 25, restricted to 24 persons until corrected.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 January 2019
Resolved 12 December 2018
Resolution: Life jacket provided.
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 12 December 2018 Resolved
Provide GPS position on VHF-DSC radio.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 January 2019
Resolved 9 January 2019
Resolution: GPS connected to the VHF-DSC radio.
Fire Fighting › Remote Fuel Shutoff › General
Issued 8 November 2017 Resolved
Prove proper operation of remote fuel shut-off valve.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 November 2017
Resolved 8 November 2017
Resolution: Fuel shut-off valve operated properly.
Fire Fighting › Means of Escape › Doorways
Issued 8 November 2017 Resolved
Make forward escape hatch accessible from both sides.
Action required: 705 - Other - as specified
Due 8 December 2017
Resolved 28 November 2017
Resolution: Escape hatch is accessible from both sides.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 8 November 2017 Resolved
Replace cracked actuator on aft hatch cover.
Action required: 705 - Other - as specified
Due 8 December 2017
Resolved 28 November 2017
Resolution: Actuator replaced.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 8 November 2017 Resolved
Permanently mark lifejacket storage locations.
Action required: 705 - Other - as specified
Due 8 December 2017
Resolved 28 November 2017
Resolution: Lifejacket storage locations are permanently marked.
Navigation › Piloting/Steering › US Coast Pilot
Issued 8 November 2017 Resolved
Update nautical pubs.
Action required: 705 - Other - as specified
Due 8 December 2017
Resolved 8 November 2017
Resolution: Pubs updated.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 8 November 2017 Resolved
Provide service report for fire fighting appliances.
Action required: 705 - Other - as specified
Due 8 December 2017
Resolved 8 November 2017
Resolution: Service report provided.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 24 September 2015 Resolved
Provide new retroreflective tape for 05 adult-size lifejackets
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2015
Resolved 29 September 2015
Navigation › Piloting/Steering › Marine Charts
Issued 24 September 2015 Resolved
Provide operating charts for catalina island, los angeles long beach, & san nicholas route.
Action required: 705 - Other - as specified
Due 30 September 2015
Resolved 29 September 2015
Communications › Radio Communications › Satellite Communications Capability
Issued 24 September 2015 Resolved
Provide FCC Iridium orglobal star satellite phone waiver exemption, or install medium frequency radio, limited to coastwise route.
Action required: 705 - Other - as specified
Resolved 24 September 2015
Resolution: Vessel provided FCC exemption waiver, all satisfactory. Valid until 26JUL2017.
Documentation › Logs/Records › Logbook (official)
Issued 24 September 2015 Resolved
Provide logbook to record drills, epirb testing, etc.
Action required: 705 - Other - as specified
Due 30 September 2015
Resolved 29 September 2015
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 24 September 2015 Resolved
Provide proof of FCC operator's permit.
Action required: 705 - Other - as specified
Due 30 September 2015
Resolved 29 September 2015
Documentation › Logs/Records › MIS Form
Issued 24 September 2015 Resolved
Provide MIS report for 2014, drug & alcohol program.
Action required: 705 - Other - as specified
Due 30 September 2015
Resolved 29 September 2015
Fire Fighting › Remote Fuel Shutoff › General
Issued 24 September 2015 Resolved
Label fuel shut-off handle.
Action required: 705 - Other - as specified
Due 30 September 2015
Resolved 29 September 2015
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 24 September 2015 Resolved
Provide lock for sewage discharge.
Action required: 705 - Other - as specified
Due 30 September 2015
Resolved 29 September 2015
Lifesaving › Inflatable Liferafts › Servicing
Issued 24 September 2015 Resolved
Correctly install painter line on inflatable liferaft.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 September 2015
Resolved 24 September 2015
Resolution: Vessel installed the painter line correctly to the nometallic weaklink.
Communications › Radio Communications › Radiotelephone Transceiver (2-4 MHz)
Issued 16 December 2011 Resolved
Provide a Medium Frequency radio in accordance with 47 CFR 80.905. Vessel is limited to a Limited Coastwise route until a MF radio and a FCC Safety Radio Certificate listing the radio, is provided.
Action required: 705 - Other - as specified
Due 15 January 2012
Resolved 20 June 2013
Resolution: Re-issued deficiency during annual inspection on 20 JUN 13 with a new due date of 20 JUL 13.
Documentation › Certificates/Documents › FCC SSL
Issued 26 September 2011 Resolved
Provide FCC radio safety certificate.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 January 2012
Resolved 20 June 2013
Resolution: Re-issued deficiency during annual exam on 20 JUN13 with new due date of 04 JUL 13.
Documentation › Certificates/Documents › FCC SSL
Issued 26 September 2011 Resolved
Provide FCC radio operators permit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 October 2011
Resolved 27 October 2011
Resolution: FCC license in sat condition.
Documentation › Markings/Placards › Lifejacket Placard
Issued 26 September 2011 Resolved
Provide and post life jacket instruction placard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 October 2011
Resolved 27 October 2011
Resolution: Placards posted
Lifesaving › Hand Flares › Not on Board
Issued 26 September 2011 Resolved
Provide proper amount of flares.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 October 2011
Resolved 27 October 2011
Resolution: Flares inspected satisfactory.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 26 September 2011 Resolved
Provide emergency broadcast placard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 October 2011
Resolved 27 October 2011
Resolution: Placards posted.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 26 September 2011 Resolved
Provide proper water light battery.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 October 2011
Resolved 27 October 2011
Resolution: Proper waterlight battery installed.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 26 September 2011 Resolved
Provide up to date Notice to Mariners.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 October 2011
Resolved 27 October 2011
Resolution: Updated notice to mariners on board.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 26 September 2011 Resolved
Provide current alcohol test swabs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 October 2011
Resolved 27 October 2011
Resolution: Current alcohol test swabs on board.
Accommodation/Occupational Safety › Sleeping Accommodations › Berth
Issued 26 September 2011 Resolved
Provide smoke detectors for overnight accommodations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 October 2011
Resolved 27 October 2011
Resolution: Smoke detectors installed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 26 September 2011 Resolved
Secure battery wires in forepeak
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 October 2011
Resolved 27 October 2011
Resolution: Battery wires properly secured.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 13 September 2011 Resolved
Provide guards on both generator fan belts.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 October 2011
Resolved 27 October 2011
Resolution: Guards installed on both generators.
Engineering › Freshwater Generation System › Piping
Issued 13 September 2011 Resolved
Repair leaking pipe above battery switch.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 October 2011
Resolved 27 October 2011
Resolution: Pipe repaired.
Engineering › Bilge Water Management System › Not Operational
Issued 13 September 2011 Resolved
Prove proper operation of primary bilge suction in generator room space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 October 2011
Resolved 27 October 2011
Resolution: Replaced check valve. Proper bilge operation proven.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 13 September 2011 Resolved
Provide proper fire extinguisher brackets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 October 2011
Resolved 27 October 2011
Resolution: Proper brackets installed.
Lifesaving › Hand Flares › Expired
Issued 9 December 2010 Resolved
Found 03 expired flares. Owner replaced prior to me leaving the vessel.
Action required: 705 - Other - as specified
Due 9 December 2010
Resolved 9 December 2010
Resolution: Replaced with new.
Electrical › Electrical Distribution System (service) › Wiring
Issued 19 November 2007 Resolved
Provide metal supports for all cable and wiring in accordance with 46CFR183.340
Action required: 705 - Other - as specified
Due 2 January 2008
Resolved 21 December 2007
Electrical › Lighting (service) › Lighting Fixture
Issued 19 November 2007 Resolved
Replace cracked light fixture cover, centerline engine room in accordance with 46CFR183.410.
Action required: 705 - Other - as specified
Due 2 January 2008
Resolved 21 December 2007
Engineering › Lubricating Oil Service System › Hose
Issued 19 November 2007 Resolved
Fix leak in oil hose between oil filter and oil cooler on starboard main engine.
Action required: 705 - Other - as specified
Due 2 January 2008
Resolved 21 December 2007
Fire Fighting › Fixed Halon Fire Extinguishing System › Tanks
Issued 19 November 2007 Resolved
Make fixed fire extinguishing system for engine room operable and provide service report for same prior to carrying passengers.
Action required: 705 - Other - as specified
Due 19 December 2007
Resolved 20 November 2007
Resolution: Proof on inspection and re-installation received from [name withheld] Extinguisher, Inc.
Engineering › Fuel Oil Service System › Valve
Issued 13 March 2007 Resolved
Provide a shutoff valve located at each fuel tank supply line, operable from outside the compartment. This item must be corrected by the next annual inspection.
Action required: 705 - Other - as specified
Due 11 September 2007
Resolved 19 December 2007
Resolution: Valves installed and inspected by [name withheld] and [name withheld] during annual inspection.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 13 March 2007 Resolved
Provide a guard for both port and starboard main engine crankshaft pulley located on the front of each engine.
Action required: 705 - Other - as specified
Due 11 September 2007
Resolved 19 December 2007
Resolution: Guards installed and inspected by [name withheld] and [name withheld] during annual inspection.
Stability › Watertight Integrity › General
Issued 13 March 2007 Resolved
Provide a valve located at the hull for both port and starboard main engine exhaust cooling water bypass located at the front of each main engine.
Action required: 705 - Other - as specified
Due 11 September 2007
Resolved 19 November 2007
Resolution: Valves installed and inspected by [name withheld] and [name withheld] during annual inspection.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 18 January 2005 Resolved
Remove bench seating on main deck
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 July 2006
Resolution: Bench seating removed.
Engineering › Bilge Water Management System › Not Operational
Issued 18 January 2005 Resolved
Clean engineroom bilges and identify and secure source of oil leaks
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 July 2006
Resolution: Bilges clean, no leaks detected.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 18 January 2005 Resolved
Replace P/S MDE exhaust lagging
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 July 2006
Resolution: Exhaust lagging replaced.
Construction/Loadline › Structures › Machinery Space Opening
Issued 18 January 2005 Resolved
Repair hatch closure devices on machinery space access hatches.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 July 2006
Resolution: Hatches repaired.
Stability › Water on Deck › General
Issued 18 January 2005 Resolved
Secure port engine hatch drain line
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 July 2006
Resolution: Secured hatch drain.
Engineering › Sea-water System (primary cooling) › Pump
Issued 18 January 2005 Resolved
Secure waterpump on portside of engineroom
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 July 2006
Resolution: Secured water pump.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 18 January 2005 Resolved
Repair main deck railing as necessary to meet 46 CFR 177.900(b)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 July 2006
Resolution: Repaired railings.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 18 January 2005 Resolved
Replace forward MSD holding tank shelf
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 July 2006
Resolution: Remounted MSD.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 18 January 2005 Resolved
Obtain valid Certficate of Documentation
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 July 2006
Resolution: Attained vaild COD.
Construction/Loadline › Structures › Manhole
Issued 18 January 2005 Resolved
Install captive chain on forepeak scuttle.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 July 2006
Resolution: Installed captive chain.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 10 December 2004 Resolved
Vessel is overdue for hull inspection. Vessel shall not operate with passengers until credit drydock is complete.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 January 2005
Resolved 18 January 2005
Resolution: Completed credit drydock and internal structural exam
Documentation › Certificates/Documents
Issued 1 April 2004 Resolved
Provide current FCC operators license
Action required: 705 - Other - as specified
Due 30 April 2004
Resolved 13 April 2004
Documentation › Certificates/Documents › FCC SSL
Issued 1 April 2004 Resolved
Provide FCC safety Cert.
Action required: 705 - Other - as specified
Due 30 April 2004
Resolved 13 April 2004
Documentation › Logs/Records › Logbook (official)
Issued 1 April 2004 Resolved
Keep up to date trng log aboard vessel.
Due 30 April 2004
Resolved 13 April 2004
Documentation › Logs/Records › Drug Test Records
Issued 1 April 2004 Resolved
provide proof of current enrollement in drug testing program.
Due 30 April 2004
Resolved 13 April 2004
Documentation › Logs/Records › Drug Test Records
Issued 1 April 2004 Resolved
Provide annual drug testing results report to headquarters.
Due 30 April 2004
Resolved 13 April 2004
Electrical › Electric Supply System (service) › Cable
Issued 1 April 2004 Resolved
Put wiring for masthead light in proper junction box
Due 9 April 2004
Resolved 13 April 2004
Navigation › Piloting/Steering
Issued 1 April 2004 Resolved
Provide up to date copies of chart, coast pilot, light list and tide and current tables.
Due 30 April 2004
Resolved 9 April 2004
Communications › Radio Communications › VHF Radiotelephone
Issued 1 April 2004 Resolved
Repair and prove proper operation of installed VHF radio.
Due 16 April 2004
Resolved 19 July 2004
Resolution: 19 July 2004- Contacted 1st Mate on the BLUE ESCAPE (Ryan). I asked him if this deficiency had in fact been taken care of and he said it was signed off by CG Inspector [name withheld] in May 2004. [name withheld]
Lifesaving › Hand Flares › Quantity
Issued 1 April 2004 Resolved
Provide 3 orange day smokes.
Due 30 April 2004
Resolved 13 April 2004
Lifesaving › Hand Flares › Storage
Issued 1 April 2004 Resolved
Mark watertight container for flares and smokes "Distress Signals" in accordance with Regs.
Due 30 April 2004
Resolved 13 April 2004
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 1 April 2004 Resolved
Provide service report for extinguishers and firxed fire fighting system.
Due 30 April 2004
Resolved 16 April 2004
Fire Fighting › Miscellaneous Items
Issued 1 April 2004 Resolved
Install smoke detector in berthing area
Due 30 April 2004
Resolved 13 April 2004
Construction/Loadline › Penetrations
Issued 1 April 2004 Resolved
Provide access to bilge in forward compartment (berthing area).
Due 30 April 2004
Resolved 16 April 2004
Engineering › Bilge Water Management System
Issued 1 April 2004 Resolved
Prove propre operation of bilge system.
Due 30 April 2004
Resolved 16 April 2004
Engineering › Diesel Engine (propulsion-reduction gear) › Bearing
Issued 12 December 2002 Resolved
Repair oil leaks to both MDE's. Provide repair report. Conduct oeprational test to the satisfaction of attending Coast Guard Marine Inspector.
Action required: 705 - Other - as specified
Due 12 March 2003
Resolved 16 July 2004
Communications › Radio Communications
Issued 22 May 2002 Resolved
Provide valid FCC operators licsense. LEGACY COMPONENT DESC: VFH Radiotelephone
Condition: Unknown
Due 23 June 2002
Resolved 21 June 2002
Operations/Management › Drills/Instruction
Issued 22 May 2002 Resolved
Provide log book with drills logged. LEGACY COMPONENT DESC: Man Overboard Recovery
Condition: Unknown
Due 23 June 2002
Resolved 21 June 2002
Lifesaving › Buoyant Apparatus
Issued 22 May 2002 Resolved
Re-rig sea painter for buoyant apparatus. LEGACY COMPONENT DESC: sea painter
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 May 2002
Lifesaving › Lifejacket/PFD (Type I)
Issued 22 May 2002 Resolved
Provide one adult PFD. LEGACY COMPONENT DESC: Condition
Condition: Improper/Lack of Maintenance
Due 23 June 2002
Resolved 21 June 2002
Lifesaving › Buoyant Apparatus
Issued 22 May 2002 Resolved
Provide water light for buoyant apparatus. LEGACY COMPONENT DESC: Water Light
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 May 2002
Resolved 23 May 2002
Lifesaving › Buoyant Apparatus
Issued 22 May 2002 Resolved
Provide proper size paddles for buoyant apparatus. LEGACY COMPONENT DESC: paddles
Condition: Improper Installation
Due 23 June 2002
Resolved 21 June 2002
Operations/Management › Drills/Instruction
Issued 22 May 2002 Resolved
Conduct drills to the satisfaction of attending CG marine inspector. LEGACY COMPONENT DESC: Man Overboard Recovery
Condition: Unknown
Due 23 June 2002
Resolved 21 June 2002
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 22 May 2002 Resolved
Provide servicing for fixed system. LEGACY COMPONENT DESC: Tanks
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 May 2002
Construction/Loadline › Penetrations
Issued 22 May 2002 Resolved
Seal deck where emergy fuel stops penetrate deck. LEGACY COMPONENT DESC: Deck
Condition: Improper/Lack of Maintenance
Due 23 June 2002
Resolved 21 June 2002
Construction/Loadline › Penetrations
Issued 22 May 2002 Resolved
Seal bulkhead penetration where pipe comes through aft bulkhead of engine room. LEGACY COMPONENT DESC: Pipe Flange
Condition: Improper Installation
Due 23 June 2002
Resolved 21 June 2002
Engineering
Issued 22 May 2002 Resolved
Clean oil residue from engine room. LEGACY COMPONENT DESC: engine room
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 May 2002
Engineering › Diesel Engine (propulsion-direct drive)
Issued 22 May 2002 Resolved
Secure lagging to exhaust piping. LEGACY COMPONENT DESC: Piping (exhaust)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 May 2002
Engineering › Fuel Oil Storage/Transfer System
Issued 22 May 2002 Resolved
Make emergy fuel stop operable. LEGACY COMPONENT DESC: Valve
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 May 2002
Engineering › Diesel Engine (propulsion-direct drive)
Issued 22 May 2002 Resolved
Install hose clamps on all hoses that handle raw water. LEGACY COMPONENT DESC: R/W cooling
Condition: Improper Installation
Due 23 June 2002
Resolved 23 May 2002
Electrical › Electric Generation Source (service)
Issued 22 May 2002 Resolved
Clean windings from starb. alternator. LEGACY COMPONENT DESC: Alternator
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2002
Resolved 21 June 2002
Engineering › Bilge Water Management System
Issued 22 May 2002 Resolved
Make bilge alarms operable. LEGACY COMPONENT DESC: alarm
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 May 2002
Engineering › Bilge Water Management System
Issued 22 May 2002 Resolved
Replace pedro on laz. bilge suction. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 May 2002
Engineering › Steering Gear System
Issued 22 May 2002 Resolved
Secure hydraulic pipes to bulkhead. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 May 2002
Engineering › Bilge Water Management System
Issued 22 May 2002 Resolved
Secure bilge pump switch to deck. LEGACY COMPONENT DESC: switch
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 May 2002
Electrical › Electrical Distribution System (service)
Issued 22 May 2002 Resolved
Install metallic wire hangers on wire runs. LEGACY COMPONENT DESC: Cable
Condition: Improper Installation
Due 23 June 2002
Resolved 21 June 2002
Engineering › Fuel Oil Storage/Transfer System
Issued 22 May 2002 Resolved
Install hose clamps on port tank fill line. LEGACY COMPONENT DESC: Piping
Due 23 June 2002
Resolved 21 June 2002
Electrical › Electric Generation Source (service)
Issued 22 May 2002 Resolved
Clean battery trays. LEGACY COMPONENT DESC: Battery
Due 23 June 2002
Resolved 21 June 2002
Engineering › Freshwater System (air cooling)
Issued 22 May 2002 Resolved
Pipe potable water vent to atmosphere. LEGACY COMPONENT DESC: Vent
Due 23 June 2002
Resolved 21 June 2002
Electrical › Lighting (service)
Issued 22 May 2002 Resolved
Install globe on light in gen. rm. LEGACY COMPONENT DESC: Lighting Fixture
Due 23 June 2002
Resolved 21 June 2002
Electrical › Electrical Distribution System (emergency)
Issued 22 May 2002 Resolved
Remove dead ended wires from engine room and transom LEGACY COMPONENT DESC: Cable
Due 23 June 2002
Resolved 21 June 2002
Electrical › Electrical Distribution System (service)
Issued 22 May 2002 Resolved
Make proper ele. connection in laz. starb. side. LEGACY COMPONENT DESC: Cable
Due 23 June 2002
Resolved 21 June 2002
Lifesaving
Issued 4 September 2001 Resolved
Vessel missing one lifefloat. Vessel restricted to carry max. of 36 passengers.
Condition: Unknown
Due 26 October 2001
Resolved 26 October 2001
Lifesaving
Issued 4 September 2001 Resolved
Replace stencil on forward escape hatch, exterior deck.
Condition: Unknown
Due 26 October 2001
Resolved 26 October 2001
Construction/Loadline
Issued 6 February 2001 Resolved
Provide metallic valves and penetrations for PVC piping traversing watertight bulkheads.
Condition: Unknown
Due 1 February 2002
Resolved 23 May 2002
Construction/Loadline
Issued 6 February 2001 Resolved
Provide damage control kit to be stored in accessible area above the bulkhead deck.
Condition: Unknown
Due 9 July 2001
Resolved 9 July 2001
Electrical
Issued 6 June 2000 Resolved
Remove all extension cords permanently installed throughout vessel
Condition: Unknown
Due 9 June 2000
Resolved 9 June 2000
Fire Fighting
Issued 6 June 2000 Resolved
Service fixed fire fighting sys.
Condition: Unknown
Due 9 June 2000
Resolved 9 June 2000
Documentation
Issued 6 June 2000 Resolved
Post emergency instructions.
Condition: Unknown
Due 13 June 2000
Resolved 14 June 2000
Documentation
Issued 6 June 2000 Resolved
Update charts.
Condition: Unknown
Due 13 June 2000
Resolved 14 June 2000
Lifesaving
Issued 6 June 2000 Resolved
Life ring needs floatable line for water light and ring buoy.
Condition: Unknown
Due 13 June 2000
Resolved 14 June 2000
Construction/Loadline
Issued 6 June 2000 Resolved
Install keeper chains on deck hatches.
Condition: Unknown
Due 13 June 2000
Resolved 14 June 2000
Electrical
Issued 6 June 2000 Resolved
Engine room lights need protective cage around glass globes.
Condition: Unknown
Due 13 June 2000
Resolved 14 June 2000
Accommodation/Occupational Safety
Issued 6 June 2000 Resolved
Lock MSD thru hull valve.
Condition: Unknown
Due 13 June 2000
Resolved 14 June 2000
Lifesaving
Issued 6 June 2000 Resolved
Rafts need retro reflective tape
Condition: Unknown
Due 13 June 2000
Resolved 14 June 2000
Lifesaving
Issued 6 June 2000 Resolved
Lable paddles for life floats.
Condition: Unknown
Due 13 June 2000
Resolved 14 June 2000
Lifesaving
Issued 6 June 2000 Resolved
Replace water light on life float.
Condition: Unknown
Due 13 June 2000
Resolved 14 June 2000
Electrical
Issued 6 June 2000 Resolved
Remove all house wire nuts.
Condition: Unknown
Due 13 June 2000
Resolved 14 June 2000
Documentation
Issued 6 June 2000 Resolved
EPIRB Log missing.
Condition: Unknown
Due 13 June 2000
Resolved 14 June 2000
Construction/Loadline
Issued 6 June 2000 Resolved
Install bilge alarms
Condition: Unknown
Due 9 June 2000
Resolved 9 June 2000
Engineering
Issued 6 June 2000 Resolved
Port turbo oil drain line leaks.
Condition: Unknown
Due 9 June 2000
Resolved 9 June 2000
Engineering
Issued 6 June 2000 Resolved
Repair port remote fuel shut down.
Condition: Unknown
Due 9 June 2000
Resolved 9 June 2000
Lifesaving
Issued 6 June 2000 Resolved
Replace outdated flares.
Condition: Unknown
Due 9 June 2000
Resolved 9 June 2000
Navigation
Issued 6 June 2000 Resolved
Double nut steering gear.
Condition: Unknown
Due 9 June 2000
Resolved 9 June 2000
Lifesaving
Issued 6 June 2000 Resolved
Post PFD Donning placard.
Condition: Unknown
Due 13 June 2000
Resolved 14 June 2000
Lifesaving
Issued 6 June 2000 Resolved
Missing hydro release experation date for epirb,
Condition: Unknown
Due 13 June 2000
Resolved 14 June 2000
Fire Fighting
Issued 4 November 1999 Resolved
Post proper operating instructions for the fixed fire system._x001C_
Condition: Unknown
Due 19 November 1999
Resolved 18 November 1999
Lifesaving
Issued 1 June 1999 Resolved
PROVIDE EMERGENCY INSTRUCTIONS FOR RADIO.
Condition: Unknown
Due 1 June 1999
Resolved 1 June 1999
Navigation
Issued 1 June 1999 Resolved
REPLACE STEERING HYDRAULIC MOUNTING BRACKET.
Condition: Unknown
Due 1 June 1999
Resolved 1 June 1999
Electrical
Issued 1 June 1999 Resolved
PROVIDE CONDUIT FOR WIRING BUNDLE IN GENERATOR SPACE (STARBOARD SIDE).
Condition: Unknown
Due 1 June 1999
Resolved 1 June 1999
Documentation
Issued 1 June 1999 Resolved
PROVIDE WASTE MANAGEMENT PLAN.
Condition: Unknown
Due 1 June 1999
Resolved 1 June 1999
Fire Fighting
Issued 1 June 1999 Resolved
PROVIDE TIMER FOR ELEC CONTROL FOR PRE-ENGINEERED FIXED FIRE SYSTEM. SYSTEM DOES NOT ALLOW CONTINUOS DISCHARGE.
Condition: Unknown
Due 1 June 1999
Resolved 1 June 1999
Fire Fighting
Issued 1 June 1999 Resolved
PROVIDE VENT CLOSURES FOR ENGINE ROOM.
Condition: Unknown
Due 1 June 1999
Resolved 1 June 1999
Lifesaving
Issued 1 June 1999 Resolved
REPLACE WHITE RINGBUOY WITH INTERNATIONAL ORANGE ONE.
Condition: Unknown
Due 1 June 1999
Resolved 1 June 1999
Documentation
Issued 1 June 1999 Resolved
PROVIDE CURRENT CERTIFICATION OF REGISTRY.
Condition: Unknown
Due 15 June 1999
Resolved 23 June 1999
Electrical
Issued 15 December 1998 Resolved
Provide proper covering for all batteries in way of generator compartment._x001C_
Condition: Unknown
Due 1 February 1999
Resolved 2 June 1999
Documentation
Issued 12 May 1998 Resolved
Provide and post stability letter.
Condition: Unknown
Due 27 May 1998
Resolved 29 May 1998
Lifesaving
Issued 12 May 1998 Resolved
Provide complete first aid kit with list.
Condition: Unknown
Due 12 June 1998
Resolved 27 July 1998
Electrical
Issued 12 May 1998 Resolved
Provide wire ties for loose wiring in generator space.
Condition: Unknown
Due 12 June 1998
Resolved 27 July 1998
Documentation
Issued 12 May 1998 Resolved
Provide vessel document and post.
Condition: Unknown
Due 27 May 1998
Resolved 29 May 1998
Construction/Loadline
Issued 12 May 1998 Resolved
Properly blank overboard discharge pipe in steering space on port side.
Condition: Unknown
Due 12 June 1998
Resolved 27 July 1998
Lifesaving
Issued 12 May 1998 Resolved
Provide name, person capacity, painter for 2 lifeboats.
Condition: Unknown
Due 1 June 1998
Resolved 22 June 1998
Construction/Loadline
Issued 12 May 1998 Resolved
Label bilge manifold.
Condition: Unknown
Due 12 June 1998
Resolved 27 July 1998
Electrical
Issued 12 May 1998 Resolved
Hard wire electrical power to swim step.
Condition: Unknown
Due 12 June 1998
Resolved 27 July 1998
Construction/Loadline
Issued 12 May 1998 Resolved
Repair hole in bulkhead in steering space.
Condition: Unknown
Due 12 June 1998
Resolved 27 July 1998
Navigation
Issued 12 May 1998 Resolved
Provide crew training, drill, and lifesaving logs.
Condition: Unknown
Due 12 June 1998
Resolved 27 July 1998
Lifesaving
Issued 12 June 1997 Resolved
PROVIDE WEAK LINK FOR LIFEFLOATS IN WAY OF TOP OF WHEELHOUSE PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 13 June 1997
Resolved 8 July 1997
Lifesaving
Issued 12 June 1997 Resolved
PROVIDE SERIAL NUMBER OF VESSEL'S CLASS A EPIRB OR PROVIDE AN ACCEPTABLE 406 EPIRB.
Condition: Unknown
Due 30 June 1997
Resolved 8 July 1997
Electrical
Issued 12 June 1997 Resolved
PROVIDE BELT GUARDS ON SSDGEN IN WAY OF GENERATOR SPACE.
Condition: Unknown
Due 12 July 1997
Resolved 11 July 1997
Lifesaving
Issued 3 July 1996 Resolved
Prior to carring any passengers, Conduct Emergency drills with a Coast Guard Marine Inspector on board.
Condition: Unknown
Due 3 July 1996
Resolved 3 July 1996
Lifesaving
Issued 3 July 1996 Resolved
Provide two adult Coast Guard approved life jackets prior to carring more than 34 total persons allowed.
Condition: Unknown
Due 3 July 1996
Resolved 3 July 1996
Documentation
Issued 3 July 1996 Resolved
Provide drug testing results after hiring crew and prior to carrying passengers.
Condition: Unknown
Due 3 July 1996
Resolved 3 July 1996
Construction/Loadline
Issued 16 May 1991 Resolved
Repair leaks around forward emergency escape hatch.
Condition: Unknown
Due 16 May 1991
Resolved 16 May 1991
Lifesaving
Issued 16 May 1991 Resolved
Provide one (01) set of paddles/oars for lifefloat.
Condition: Unknown
Due 16 May 1991
Resolved 16 May 1991
Deck/Cargo
Issued 16 May 1991 Resolved
Provide heat shields for fuel tank reach rod openings.
Condition: Unknown
Due 16 May 1991
Resolved 16 May 1991
Lifesaving
Issued 16 May 1991 Resolved
Repair lifefloat coverings.
Condition: Unknown
Due 16 May 1991
Resolved 16 May 1991
Electrical
Issued 16 May 1991 Resolved
Repair and prove proper operation of forward emergency lighting.
Condition: Unknown
Due 16 May 1991
Resolved 16 May 1991
Construction/Loadline
Issued 16 May 1991 Resolved
Provide lazerette hatch with capture chain.
Condition: Unknown
Due 16 May 1991
Resolved 16 May 1991
Deck/Cargo
Issued 16 May 1991 Resolved
Provide rotating machinery guard for deck washdown pump drive shaft.
Condition: Unknown
Due 16 May 1991
Resolved 16 May 1991
Electrical
Issued 16 May 1991 Resolved
Repair starboard propeller shaft bonding system.
Condition: Unknown
Due 16 May 1991
Resolved 16 May 1991
Documentation
Issued 16 May 1991 Resolved
Provide vessel with valid Certificate of Documentation, vessel is not to operate until item is corrected.
Condition: Unknown
Due 16 May 1991
Resolved 16 May 1991
Electrical
Issued 16 May 1991 Resolved
Properly support electrical wiring throughout vessel in accordance with IEEE-45.
Condition: Unknown
Due 16 May 1991
Resolved 16 May 1991
Documentation
Issued 16 May 1991 Resolved
Provide vessel with valid FCC Certificate.
Condition: Unknown
Due 16 May 1991
Resolved 16 May 1991
Engineering
Issued 20 September 1990 Resolved
REPLACE MISSING BILGE FOOT SCREEN IN LAZARETTE.
Condition: Unknown
Due 20 September 1990
Resolved 20 September 1990
Navigation
Issued 20 September 1990 Resolved
RENEW OR REMOVE CROSSOVER VALVE WHICH ISOLATES STEERING RAM FROM HYDRAULIC SYSTEM AND PROPERLY SUPPORT HYDRAULIC PIPING IN LAZARETTE.
Condition: Unknown
Due 20 September 1990
Resolved 20 September 1990
Electrical
Issued 16 May 1990 Resolved
PROVIDE EMERGENCY LIGHT IN FORWARD BUNKROOM PRIOR TO CARRIAGE OF PASSENGERSTHERE.
Condition: Unknown
Due 16 May 1990
Resolved 16 May 1990
Lifesaving
Issued 16 May 1990 Resolved
RENEW EPIRB BATTERY.
Condition: Unknown
Due 16 May 1990
Resolved 16 May 1990
Construction/Loadline
Issued 16 May 1990 Resolved
RENEW FLEXIBLE HOSE AT FORWARD HOLDING TANK DISCHARGE.
Condition: Unknown
Due 16 May 1990
Resolved 16 May 1990
Engineering
Issued 16 May 1990 Resolved
PROVIDE TWO RAYCOR FUEL FILTER FLAME BOWLS, ONE AT EACH MAIN ENGINE FILTER.
Condition: Unknown
Due 16 May 1990
Resolved 16 May 1990
Accommodation/Occupational Safety
Issued 16 May 1990 Resolved
INSTALL PLACARD WARNING NOT TO DISCHARGE WASTE FROM HOLDING TANK IN U. S. WATERS OR LOCK VALVE SHUT IN PORT.
Condition: Unknown
Due 16 May 1990
Resolved 16 May 1990
Lifesaving
Issued 5 December 1989 Resolved
PRIOR TO CARRYING MORE THAN 24 PERSONS ON OCEAN ROUTE, 48 ON COASTWISE ROUTE OR 50 ON LAKES, BAYS AND SOUNDS: PROVIDE NEW LIFE LINES, TWO PADDLES AND WATERLIGHT FOR FORWARD LIFEFLOAT. STOW FLOATS IN ACCORDANCE WITH 46 CFR 180.20, PROVIDING PROPER FLOAT FREE ARRANGEMENT.
Condition: Unknown
Due 5 December 1989
Resolved 5 December 1989
Construction/Loadline
Issued 2 October 1989 Resolved
EITHER PROPERLY CAP THROUGH HULL WITH BRONZE PIPE CAP OR INSTALL SEA VALVE INBOARD OF DISCHARGE FOR OLD BAIT TANK AT PORT SIDE IN LAZARETTE.
Condition: Unknown
Due 2 October 1989
Resolved 2 October 1989
Construction/Loadline
Issued 2 November 1987 Resolved
REPAIR FRACTURE IN FIBERGLASS WHERE TRANSOM MEETS MAIN DECK IN AFT PORT CORNER OF LAZARETTE.
Condition: Unknown
Due 2 November 1987
Resolved 2 November 1987
Navigation
Issued 10 May 1985 Resolved
REPAIR STEERING GEAR ELIMINATE SLOP AND ELONGATED BOLT HOLES IN RUDDER BAR
Condition: Unknown
Due 10 May 1985
Resolved 10 May 1985
Construction/Loadline
Issued 10 May 1985 Resolved
GRIND OUT CRACK AND REGLASS AFT DECK VENTS
Condition: Unknown
Due 10 May 1985
Resolved 10 May 1985
Lifesaving
Issued 10 May 1985 Resolved
PROVIDE 1 LIFEFLOAT PADDLE
Condition: Unknown
Due 10 May 1985
Resolved 10 May 1985
Construction/Loadline
Issued 10 May 1985 Resolved
REPLACE WASTED RUBRAIL BOLTS IN LAZARETTE
Condition: Unknown
Due 10 May 1985
Resolved 10 May 1985
Documentation
Issued 10 May 1985 Resolved
PROVIDE DOLUMENT ON BOARD VESSEL
Condition: Unknown
Due 10 May 1985
Resolved 10 May 1985

Casualty record · 1

2 July 2004Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 2201305
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

BLUE ESCAPE (2004). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.