Inspection history · 33
4 May 2026
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8361835
17 February 2026
In-Service Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8311433
2 September 2025
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8225110
3 July 2025
Damage Survey · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8173955
15 April 2025
In-Service Inspection · Deficiency Check · Examination of Repairs · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8111352
10 April 2025
Inclining Experiment
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8146792
16 January 2025
Plan Review "T" Boat · Internal Structural Exam · Drydock Exam
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8078186
14 February 2024
Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7864888
9 January 2024
Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7847194
28 July 2023
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7884841
15 February 2023
MTSA/ISPS Verification · Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7634788
30 January 2023
Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7629401
5 December 2022
Drydock Exam · Administrative Inspection · Examination of Repairs · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7604573
3 November 2022
Plan Review "T" Boat · Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7610919
4 October 2022
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7568871
2 June 2022
Administrative Inspection · MTSA/ISPS Verification · COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7466297
31 January 2022
Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7388155
13 November 2021
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7350155
19 May 2021
COI Inspection · Deficiency Check · Administrative Inspection · MTSA/ISPS Verification
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7197128
2 February 2021
Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7134569
3 June 2020
MTSA/ISPS Verification · COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6951956
9 January 2020
Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6886003
27 September 2019
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6822585
5 June 2019
COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6697398
7 January 2019
Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6606486
7 September 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6534785
5 June 2018
COI Inspection · DAPI Audit
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6434181
5 February 2018
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6349600
8 January 2018
Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6334048
7 June 2017
Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6168905
2 June 2017
Administrative Inspection · Deficiency Check · COI Inspection · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6163496
9 January 2017
Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6068003
27 May 2016
COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5888467
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 May 2026
Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel. Vessel does not have any means to test for presence of alcohol.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2026
Resolved 11 May 2026
Resolution: Marine inspector verified swabs were purchased and on board.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 4 May 2026
Resolved
The owner, charterer, master, or managing operator of a vessel carrying overnight passengers shall have a suitable number of watchmen patrol throughout the vessel during the nighttime, whether or not the vessel is underway, to guard against, and give alarm in case of, a fire, man overboard, or other dangerous situation. Vessel watchman system was inoperable, fix watchman system and notify local OCMI.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 May 2026
Resolved 11 May 2026
Resolution: Marine inspector verified that the watchman system was functional.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 4 May 2026
Resolved
Vessel that have overnight accommodations must have interconnected fire detection system. Smoke detectors would operate but would not turn off until battery was removed. Fix interconnected smoke detection and notify local OCMI.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 May 2026
Resolved 11 May 2026
Resolution: Marine inspector verified the interconnected smoke detection system is now working properly.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 4 May 2026
Resolved
On a vessel of more than 65 feet in length, the minimum capacity of the fire pump must be 50 gallons per minute at a pressure on not less than 60 PSI at pump outlet. The pump outlet must be fitted with a pressure gauge. The fire pump pressure gauge is not properly working, replace gauge.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2026
Resolved 11 May 2026
Resolution: Marine inspector verified that fire pump works at the proper pressure and gauge is working properly.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 4 May 2026
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Vessel's 02 life ring buoy is worn. Replace life ring buoy.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2026
Resolved 11 May 2026
Resolution: Marine inspector verified vessel owner replaced 02 life ring buoys.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 4 May 2026
Resolved
Waterlights should be serviceable and batteries replaced annually if not marked with an expiration date. Waterlight was inoperable. Provide serviceable waterlight and replace battery.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2026
Resolved 11 May 2026
Resolution: Marine inspector verified the waterlight on life ring buoy is now working properly. Owner replaced the battery in the waterlight.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 4 May 2026
Resolved
A complete application for an original MMC must contain proof, documented on CG-719-K or CG-719-K/E, as appropriate, that the applicant passed all applicable vision, hearing, medical, and/or physical exams as required by subpart C of this part or a valid medical certificate issued by the Coast Guard. The Master did not have his medical certificate available.Provide master who has valid medical certificate to meet manning requirments.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2026
Resolved 11 May 2026
Resolution: Owner completed the process to renew his medical certificate and is awaiting receipt of the new card.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 May 2026
Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, the maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least 1 inch numbers and letters at the entranceway to that deck. Vessel did not have the correct number of passengers allowed posted on aft stairwell, and missing sign on front stairwell.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2026
Resolved 11 May 2026
Resolution: Marine inspector verified the maximum passenters allowed on the upper deck at one time is posted next to the ladder leading to the upper deck.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 4 May 2026
Resolved
Except as provided in 80.13(c), stations must have an authorization granted by the Federal Communications Commission. Vessel could not produce current FCC station license during annual inspection. Provide current FCC license.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2026
Resolved 11 May 2026
Resolution: Marine inspector verified a current FCC license is on board.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 3 July 2025
Resolved
Vessel's hull sustained damage while underway. Hull damage is port side chine, amidships IWO fuel tank, approx 24" long. Damaged area of hull impacts the vessel's seaworthiness and posses a potential pollution risk. Crop and renew damaged aluminum plating to the satisfaction of attending marine inspector. Adjacent integral fuel tank must be gas-free with marine chemist certificate prior to any hot work. Crop and renew must be completed prior to carrying passengers or vessel making any voyages.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 14 July 2025
Resolution: Crop and renew repairs completed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 July 2025
Resolved
Vessel's port propeller was damaged while underway. Provide servicing report from propeller shop after repairs are made to the port prop. Report must be provided prior to carrying passengers.
Action required: 705 - Other - as specified
Resolved 14 July 2025
Resolution: A spare prop was used to replace the damaged prop.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 15 April 2025
Resolved
Vessel upgraded the throttle control system after re powering the main engines. Vessel rep submitted QFA/DVTP to MSC. Once approved by MCS, preform power loss procedure to attending marine inspector.
Action required: 705 - Other - as specified
Resolved 20 May 2025
Resolution: MSC approved QFA, witnessed power failure test, all sat.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 15 April 2025
Resolved
Complete underway man overboard and fire drills.
Action required: 705 - Other - as specified
Resolved 20 May 2025
Resolution: Witnessed underway drills.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 15 April 2025
Resolved
Fire servicing company identified a failed CO2 activation pull handle. Repair pull handle.
Action required: 705 - Other - as specified
Resolved 20 May 2025
Resolution: Pull handle and cable replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 April 2025
Resolved
The emergency lighting breaker failed while testing the circuit, make repairs and prover operation of emergency lighting.
Action required: 705 - Other - as specified
Resolved 22 May 2025
Resolution: Operationally tested all emergency lighting, all sat.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 15 April 2025
Resolved
First aid kit was fond to have expired items, provide kit with updated items.
Action required: 705 - Other - as specified
Resolved 20 May 2025
Resolution: New first aid kit was provided.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 14 February 2024
Resolved
All griddles, broilers, and deep fat fryers must be fitted with a grease extraction hood in compliance with 181.425. A grease extraction hood must meet UL 710 or other standard specified by the Commandant. A grease
extraction hood must be equipped with a dry or wet chemical fire extinguishing system meeting NFPA 17 or other standard specified by the Commandant, and must be listed by an independent laboratory recognized by
the Commandant. Install grease extraction hood equipped with a dry or wet chemical fire extinguishing system to the satisfaction of an attending marine inspector at next credit drydock, not later than Jan 1, 2026.
Action required: 705 - Other - as specified
Due 1 January 2026
Resolved 4 May 2026
Resolution: Marine inspector confirmed vessel installed grease extraction hood equipped with a dry chemical fire extinguishing system.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 February 2024
Resolved
On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate a high water level.
Two bilge alarms in the forward bunk room and aft bunk room were inoperable.
Action required: 17 - Rectify deficiencies prior to departure
Due 24 February 2024
Resolved 19 February 2024
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 15 February 2023
Resolved
Inadequate number of flares kept onboard.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 16 February 2023
Resolution: Vessel restricted to Lakes Bays and Sounds until def is rectified.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 15 February 2023
Resolved
Interconnected fire detection and alarm sensor not installed in engine room compartment.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 24 February 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 February 2023
Resolved
02 life ring buoys require replacement.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 March 2023
Resolved 20 March 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 February 2023
Resolved
Electrical panel circuit breaker slot not covered.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 March 2023
Resolved 24 February 2023
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 15 February 2023
Resolved
DAPI Program current employee not added to list.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 February 2023
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 2 June 2022
Resolved
Vessel's forward and aft berthing areas do not have a PA system. Provide a temporary method to alert people in the forward and aft berthing areas of emergencies, and submit a proposal for a permanent solution for the installation of a PA system in those berthing areas.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 June 2022
Resolution: Vessel installed a new PA installation in the two hallways of the lower berthing areas.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 2 June 2022
Resolved
Provide an up to date USCG Lights List for the vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 June 2022
Resolved 28 July 2022
Resolution: Vessel acquired applicable print outs of the 2022 light list.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 31 January 2022
Resolved
Excessive pitting found on stbd quarter in Lazarette. Repairs shall be made at next drydock period.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 20 December 2022
Resolution: Repair completed and documented in activity # 7604573.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 19 May 2021
Resolved
Each overnight accommodation space on a vessel with overnight accommodations for passengers must be fitted with an independent modular smoke detecting and alarm unit in compliance with 181.450. The 02 berthing areas on the second deck do not have adequate smoke detectors. Provide adequate smoke detectors for the second deck berthing areas.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2021
Resolved 16 July 2021
Resolution: INSTALLED
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 19 May 2021
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. Vessel's first-aid kit had several expired items. Provide valid equipment to the first-aid kit.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2021
Resolved 16 July 2021
Resolution: KIT PURCHASED
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 19 May 2021
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: Charts of large enough scale to make safe navigation possible. Vessel's charts were more than 4 years out of date. Provide update to date charts for the vessel's intended voyages.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2021
Resolved 16 July 2021
Resolution: UPDATED
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 3 June 2020
Resolved
Provide DSC capabilities for VHF radio.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 June 2020
Resolution: DSC capabilities provided.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 3 June 2020
Resolved
Provide valid STCW medical certifice for [name withheld].
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 September 2020
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 3 June 2020
Resolved
Provide valid medical certificate for Evan Kraft.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 September 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 September 2019
Resolved
Sector San Diego does not have vessels electrical plans on file. Provide a one-line electrical drawing for all A/C switchboards and distribution panels. Include all circuit loads, conductor sizes, over current protection, and max panel ratings in amps.
Action required: 705 - Other - as specified
Due 27 December 2019
Resolved 12 June 2020
Resolution: Final electrical drawing provided, verified onboard, and placed in vessel documents.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 7 September 2018
Resolved
IMO: Vsl is broadcasting no IMO #, ZERO LENGTH OR BEAM: no dimension information (AIS Antenna Position ABCD values equals 0), ZERO DRAFT: no static draft information
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 4 December 2018
Resolution: Verified in VIVS
Communications › Alarms/Indicators › Bilge Alarm
Issued 6 June 2017
Resolved
Prove proper operation of forepeak bilge alarm
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 June 2017
Resolution: Forepeak bilge alarm operational.
Navigation › Piloting/Steering › Marine Charts
Issued 6 June 2017
Resolved
Provide current and correct charts for area of operation
Action required: 705 - Other - as specified
Due 6 July 2017
Resolved 7 June 2017
Resolution: New charts provided.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 6 June 2017
Resolved
Provide batteries for identified smoke detectors in accommodation spaces.
Action required: 705 - Other - as specified
Due 6 July 2017
Resolved 7 June 2017
Resolution: Smoke detector operational.