MAURY USCG vessel records
← All vessels

SPIRIT OF ADVENTURE

Built
1976
Last inspected
4 May 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 4 May 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

8229729
WAV5237
Flag
UNITED STATES
Maury page id
psix-48794

Documentation record

Registered dimensions (L × B × D)81.4 ft × 24.4 ft × 6.7 ft
Registered tonnagegross 99 / net 67
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderPOOLE BOAT COMPANY · CHULA VISTA, CA, UNITED STATES · built 1976
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAN DIEGO, CA
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 5 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it99 - Regulatory (Subpart C or D), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 33 inspections, each with its date, unit and type; 37 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 33

4 May 2026 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8361835
17 February 2026 In-Service Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8311433
2 September 2025 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8225110
3 July 2025 Damage Survey · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8173955
15 April 2025 In-Service Inspection · Deficiency Check · Examination of Repairs · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8111352
10 April 2025 Inclining Experiment
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8146792
16 January 2025 Plan Review "T" Boat · Internal Structural Exam · Drydock Exam
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8078186
14 February 2024 Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7864888
9 January 2024 Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7847194
28 July 2023 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7884841
15 February 2023 MTSA/ISPS Verification · Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7634788
30 January 2023 Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7629401
5 December 2022 Drydock Exam · Administrative Inspection · Examination of Repairs · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7604573
3 November 2022 Plan Review "T" Boat · Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7610919
4 October 2022 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7568871
2 June 2022 Administrative Inspection · MTSA/ISPS Verification · COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7466297
31 January 2022 Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7388155
13 November 2021 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7350155
19 May 2021 COI Inspection · Deficiency Check · Administrative Inspection · MTSA/ISPS Verification
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7197128
2 February 2021 Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7134569
3 June 2020 MTSA/ISPS Verification · COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6951956
9 January 2020 Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6886003
27 September 2019 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6822585
5 June 2019 COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6697398
7 January 2019 Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6606486
7 September 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6534785
5 June 2018 COI Inspection · DAPI Audit
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6434181
5 February 2018 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6349600
8 January 2018 Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6334048
7 June 2017 Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6168905
2 June 2017 Administrative Inspection · Deficiency Check · COI Inspection · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6163496
9 January 2017 Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6068003
27 May 2016 COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5888467

Deficiency record · 37

99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 May 2026 Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel. Vessel does not have any means to test for presence of alcohol.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2026
Resolved 11 May 2026
Resolution: Marine inspector verified swabs were purchased and on board.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 4 May 2026 Resolved
The owner, charterer, master, or managing operator of a vessel carrying overnight passengers shall have a suitable number of watchmen patrol throughout the vessel during the nighttime, whether or not the vessel is underway, to guard against, and give alarm in case of, a fire, man overboard, or other dangerous situation. Vessel watchman system was inoperable, fix watchman system and notify local OCMI.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 May 2026
Resolved 11 May 2026
Resolution: Marine inspector verified that the watchman system was functional.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 4 May 2026 Resolved
Vessel that have overnight accommodations must have interconnected fire detection system. Smoke detectors would operate but would not turn off until battery was removed. Fix interconnected smoke detection and notify local OCMI.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 May 2026
Resolved 11 May 2026
Resolution: Marine inspector verified the interconnected smoke detection system is now working properly.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 4 May 2026 Resolved
On a vessel of more than 65 feet in length, the minimum capacity of the fire pump must be 50 gallons per minute at a pressure on not less than 60 PSI at pump outlet. The pump outlet must be fitted with a pressure gauge. The fire pump pressure gauge is not properly working, replace gauge.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2026
Resolved 11 May 2026
Resolution: Marine inspector verified that fire pump works at the proper pressure and gauge is working properly.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 4 May 2026 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Vessel's 02 life ring buoy is worn. Replace life ring buoy.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2026
Resolved 11 May 2026
Resolution: Marine inspector verified vessel owner replaced 02 life ring buoys.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 4 May 2026 Resolved
Waterlights should be serviceable and batteries replaced annually if not marked with an expiration date. Waterlight was inoperable. Provide serviceable waterlight and replace battery.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2026
Resolved 11 May 2026
Resolution: Marine inspector verified the waterlight on life ring buoy is now working properly. Owner replaced the battery in the waterlight.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 4 May 2026 Resolved
A complete application for an original MMC must contain proof, documented on CG-719-K or CG-719-K/E, as appropriate, that the applicant passed all applicable vision, hearing, medical, and/or physical exams as required by subpart C of this part or a valid medical certificate issued by the Coast Guard. The Master did not have his medical certificate available.Provide master who has valid medical certificate to meet manning requirments.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2026
Resolved 11 May 2026
Resolution: Owner completed the process to renew his medical certificate and is awaiting receipt of the new card.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 May 2026 Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, the maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least 1 inch numbers and letters at the entranceway to that deck. Vessel did not have the correct number of passengers allowed posted on aft stairwell, and missing sign on front stairwell.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2026
Resolved 11 May 2026
Resolution: Marine inspector verified the maximum passenters allowed on the upper deck at one time is posted next to the ladder leading to the upper deck.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 4 May 2026 Resolved
Except as provided in 80.13(c), stations must have an authorization granted by the Federal Communications Commission. Vessel could not produce current FCC station license during annual inspection. Provide current FCC license.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2026
Resolved 11 May 2026
Resolution: Marine inspector verified a current FCC license is on board.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 3 July 2025 Resolved
Vessel's hull sustained damage while underway. Hull damage is port side chine, amidships IWO fuel tank, approx 24" long. Damaged area of hull impacts the vessel's seaworthiness and posses a potential pollution risk. Crop and renew damaged aluminum plating to the satisfaction of attending marine inspector. Adjacent integral fuel tank must be gas-free with marine chemist certificate prior to any hot work. Crop and renew must be completed prior to carrying passengers or vessel making any voyages.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 14 July 2025
Resolution: Crop and renew repairs completed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 July 2025 Resolved
Vessel's port propeller was damaged while underway. Provide servicing report from propeller shop after repairs are made to the port prop. Report must be provided prior to carrying passengers.
Action required: 705 - Other - as specified
Resolved 14 July 2025
Resolution: A spare prop was used to replace the damaged prop.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 15 April 2025 Resolved
Vessel upgraded the throttle control system after re powering the main engines. Vessel rep submitted QFA/DVTP to MSC. Once approved by MCS, preform power loss procedure to attending marine inspector.
Action required: 705 - Other - as specified
Resolved 20 May 2025
Resolution: MSC approved QFA, witnessed power failure test, all sat.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 15 April 2025 Resolved
Complete underway man overboard and fire drills.
Action required: 705 - Other - as specified
Resolved 20 May 2025
Resolution: Witnessed underway drills.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 15 April 2025 Resolved
Fire servicing company identified a failed CO2 activation pull handle. Repair pull handle.
Action required: 705 - Other - as specified
Resolved 20 May 2025
Resolution: Pull handle and cable replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 April 2025 Resolved
The emergency lighting breaker failed while testing the circuit, make repairs and prover operation of emergency lighting.
Action required: 705 - Other - as specified
Resolved 22 May 2025
Resolution: Operationally tested all emergency lighting, all sat.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 15 April 2025 Resolved
First aid kit was fond to have expired items, provide kit with updated items.
Action required: 705 - Other - as specified
Resolved 20 May 2025
Resolution: New first aid kit was provided.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 14 February 2024 Resolved
All griddles, broilers, and deep fat fryers must be fitted with a grease extraction hood in compliance with 181.425. A grease extraction hood must meet UL 710 or other standard specified by the Commandant. A grease extraction hood must be equipped with a dry or wet chemical fire extinguishing system meeting NFPA 17 or other standard specified by the Commandant, and must be listed by an independent laboratory recognized by the Commandant. Install grease extraction hood equipped with a dry or wet chemical fire extinguishing system to the satisfaction of an attending marine inspector at next credit drydock, not later than Jan 1, 2026.
Action required: 705 - Other - as specified
Due 1 January 2026
Resolved 4 May 2026
Resolution: Marine inspector confirmed vessel installed grease extraction hood equipped with a dry chemical fire extinguishing system.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 February 2024 Resolved
On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate a high water level. Two bilge alarms in the forward bunk room and aft bunk room were inoperable.
Action required: 17 - Rectify deficiencies prior to departure
Due 24 February 2024
Resolved 19 February 2024
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 15 February 2023 Resolved
Inadequate number of flares kept onboard.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 16 February 2023
Resolution: Vessel restricted to Lakes Bays and Sounds until def is rectified.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 15 February 2023 Resolved
Interconnected fire detection and alarm sensor not installed in engine room compartment.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 24 February 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 February 2023 Resolved
02 life ring buoys require replacement.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 March 2023
Resolved 20 March 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 February 2023 Resolved
Electrical panel circuit breaker slot not covered.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 March 2023
Resolved 24 February 2023
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 15 February 2023 Resolved
DAPI Program current employee not added to list.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 February 2023
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 2 June 2022 Resolved
Vessel's forward and aft berthing areas do not have a PA system. Provide a temporary method to alert people in the forward and aft berthing areas of emergencies, and submit a proposal for a permanent solution for the installation of a PA system in those berthing areas.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 June 2022
Resolution: Vessel installed a new PA installation in the two hallways of the lower berthing areas.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 2 June 2022 Resolved
Provide an up to date USCG Lights List for the vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 June 2022
Resolved 28 July 2022
Resolution: Vessel acquired applicable print outs of the 2022 light list.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 31 January 2022 Resolved
Excessive pitting found on stbd quarter in Lazarette. Repairs shall be made at next drydock period.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 20 December 2022
Resolution: Repair completed and documented in activity # 7604573.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 19 May 2021 Resolved
Each overnight accommodation space on a vessel with overnight accommodations for passengers must be fitted with an independent modular smoke detecting and alarm unit in compliance with 181.450. The 02 berthing areas on the second deck do not have adequate smoke detectors. Provide adequate smoke detectors for the second deck berthing areas.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2021
Resolved 16 July 2021
Resolution: INSTALLED
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 19 May 2021 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. Vessel's first-aid kit had several expired items. Provide valid equipment to the first-aid kit.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2021
Resolved 16 July 2021
Resolution: KIT PURCHASED
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 19 May 2021 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: Charts of large enough scale to make safe navigation possible. Vessel's charts were more than 4 years out of date. Provide update to date charts for the vessel's intended voyages.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2021
Resolved 16 July 2021
Resolution: UPDATED
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 3 June 2020 Resolved
Provide DSC capabilities for VHF radio.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 June 2020
Resolution: DSC capabilities provided.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 3 June 2020 Resolved
Provide valid STCW medical certifice for [name withheld].
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 September 2020
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 3 June 2020 Resolved
Provide valid medical certificate for Evan Kraft.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 September 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 September 2019 Resolved
Sector San Diego does not have vessels electrical plans on file. Provide a one-line electrical drawing for all A/C switchboards and distribution panels. Include all circuit loads, conductor sizes, over current protection, and max panel ratings in amps.
Action required: 705 - Other - as specified
Due 27 December 2019
Resolved 12 June 2020
Resolution: Final electrical drawing provided, verified onboard, and placed in vessel documents.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 7 September 2018 Resolved
IMO: Vsl is broadcasting no IMO #, ZERO LENGTH OR BEAM: no dimension information (AIS Antenna Position ABCD values equals 0), ZERO DRAFT: no static draft information
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 4 December 2018
Resolution: Verified in VIVS
Communications › Alarms/Indicators › Bilge Alarm
Issued 6 June 2017 Resolved
Prove proper operation of forepeak bilge alarm
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 June 2017
Resolution: Forepeak bilge alarm operational.
Navigation › Piloting/Steering › Marine Charts
Issued 6 June 2017 Resolved
Provide current and correct charts for area of operation
Action required: 705 - Other - as specified
Due 6 July 2017
Resolved 7 June 2017
Resolution: New charts provided.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 6 June 2017 Resolved
Provide batteries for identified smoke detectors in accommodation spaces.
Action required: 705 - Other - as specified
Due 6 July 2017
Resolved 7 June 2017
Resolution: Smoke detector operational.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.