MAURY USCG vessel records Sign in
← All vessels

SPIRIT OF ADVENTURE

SPIRIT OF ADVENTURE is a 1976 passenger vessel (inspected). The Coast Guard has recorded 105 inspections since 1985, most recently in May 2026, along with 104 deficiencies and 2 casualty investigations between 2009 and 2012.

Records from 1985 to 2026. Most recent: inspection, 4 May 2026.

Built
1976
Last inspected
4 May 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8229729 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WAV5237
Flag
UNITED STATES
367185130
Maury page id
psix-48794

Inspections, by type

…with no type recorded14
Years with a record 40 calendar years (1985–2026)
The 105 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)81.4 ft × 24.4 ft × 6.7 ft
Registered tonnagegross 99 / net 67
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderPOOLE BOAT COMPANY · CHULA VISTA, CA, UNITED STATES · built 1976
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSAN DIEGO, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 5 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it99 - Regulatory (Subpart C or D), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WAV5237MMSI 367185130 · active · compulsorily equipped · granted 29 March 2017, expires 5 June 2027
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 105

4 May 2026 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8361835
17 February 2026 In-Service Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8311433
2 September 2025 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8225110
3 July 2025 Damage Survey · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8173955
15 April 2025 In-Service Inspection · Deficiency Check · Examination of Repairs · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8111352
10 April 2025 Inclining Experiment
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8146792
16 January 2025 Plan Review "T" Boat · Internal Structural Exam · Drydock Exam
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8078186
14 February 2024 Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7864888
9 January 2024 Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7847194
28 July 2023 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7884841
15 February 2023 MTSA/ISPS Verification · Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7634788
30 January 2023 Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7629401
5 December 2022 Drydock Exam · Administrative Inspection · Examination of Repairs · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7604573
3 November 2022 Plan Review "T" Boat · Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7610919
4 October 2022 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7568871
2 June 2022 Administrative Inspection · MTSA/ISPS Verification · COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7466297
31 January 2022 Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7388155
13 November 2021 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7350155
19 May 2021 COI Inspection · Deficiency Check · Administrative Inspection · MTSA/ISPS Verification
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7197128
2 February 2021 Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7134569
3 June 2020 MTSA/ISPS Verification · COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6951956
9 January 2020 Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6886003
27 September 2019 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6822585
5 June 2019 COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6697398
7 January 2019 Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6606486
7 September 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6534785
5 June 2018 COI Inspection · DAPI Audit
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6434181
5 February 2018 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6349600
8 January 2018 Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6334048
7 June 2017 Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6168905
2 June 2017 Administrative Inspection · Deficiency Check · COI Inspection · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6163496
9 January 2017 Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6068003
27 May 2016 COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5888467
7 December 2015 In-Service Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5776640
4 June 2014 DAPI Audit · Internal Structural Exam · COI Inspection · Security Plan Review - ASP
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4879426
4 June 2012 COI Inspection · DAPI Audit
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4319209
13 December 2010 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3910100
12 March 2010 Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3694919
18 December 2009 Spot Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3652507
28 April 2009 Hull Examination · COI Inspection · DAPI Audit · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3480020
2 June 2008 COI Inspection · MTSA/ISPS Verification · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3201284
19 March 2008 Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3167639
30 May 2007 Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2925226
27 March 2007 Internal Structural Exam · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2896085
30 May 2006 Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2643887
19 April 2006 Hull Examination · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2610670
16 June 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2392594
26 May 2005 COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2347484
22 April 2005 Internal Structural Exam · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2321524
4 January 2005 Excursion Permit
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2268937
2 June 2004 MTSA/ISPS Verification
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2086324
26 May 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2078772
25 May 2004 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2051066
16 April 2004 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2026306
24 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1979675
13 June 2003 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1816576
11 June 2003 Administrative Inspection
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1815217
28 May 2003 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1803729
15 April 2003 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1774379
30 May 2002 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1622207
16 April 2002 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1605545
11 June 2001 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1066734
29 May 2001 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1453913
2 May 2001 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1362204
6 June 2000 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1436399
16 May 2000 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1376169
18 June 1999 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1369227
11 May 1999 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1441501
11 April 1999 Excursion Permit
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 813148
17 June 1998 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1128564
5 June 1998 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1447848
30 April 1998 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1390806
5 June 1997 Hull Examination · COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1364140
5 June 1997 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1413191
14 March 1997 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 212387
31 January 1997 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 191500
31 January 1997 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 763760
31 May 1996 Hull Examination · COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1355806
7 June 1995 Hull Examination · COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1467442
20 July 1994 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 861481
14 July 1994 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 867616
7 June 1994 COI Inspection · Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1382772
1 June 1993 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1134719
7 May 1993 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1135704
1 June 1992 COI Inspection · Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 945934
27 February 1992 Excursion Permit
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1373715
4 June 1991 COI Inspection · Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 903750
18 May 1990 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1213285
15 May 1990 Hull Examination · COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 905406
7 June 1989 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 889754
1 June 1989 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1043357
26 May 1989 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1030949
20 May 1988 Hull Examination · COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1043703
11 May 1987 COI Inspection · Deficiency Check · Hull Examination · Examination of Repairs
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1010982
16 January 1987 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1007739
14 May 1986 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1297891
30 April 1986 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1001219
24 April 1986 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1307898
16 April 1986 Credit Drydock
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 998754
25 November 1985 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1302492
3 October 1985 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 996309
28 June 1985 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 984603
28 June 1985 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1287785
27 June 1985 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 983207
8 February 1985 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 978339

Deficiency record · 104

99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 May 2026 Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel. Vessel does not have any means to test for presence of alcohol.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2026
Resolved 11 May 2026
Resolution: Marine inspector verified swabs were purchased and on board.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 4 May 2026 Resolved
The owner, charterer, master, or managing operator of a vessel carrying overnight passengers shall have a suitable number of watchmen patrol throughout the vessel during the nighttime, whether or not the vessel is underway, to guard against, and give alarm in case of, a fire, man overboard, or other dangerous situation. Vessel watchman system was inoperable, fix watchman system and notify local OCMI.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 May 2026
Resolved 11 May 2026
Resolution: Marine inspector verified that the watchman system was functional.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 4 May 2026 Resolved
Vessel that have overnight accommodations must have interconnected fire detection system. Smoke detectors would operate but would not turn off until battery was removed. Fix interconnected smoke detection and notify local OCMI.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 May 2026
Resolved 11 May 2026
Resolution: Marine inspector verified the interconnected smoke detection system is now working properly.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 4 May 2026 Resolved
On a vessel of more than 65 feet in length, the minimum capacity of the fire pump must be 50 gallons per minute at a pressure on not less than 60 PSI at pump outlet. The pump outlet must be fitted with a pressure gauge. The fire pump pressure gauge is not properly working, replace gauge.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2026
Resolved 11 May 2026
Resolution: Marine inspector verified that fire pump works at the proper pressure and gauge is working properly.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 4 May 2026 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Vessel's 02 life ring buoy is worn. Replace life ring buoy.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2026
Resolved 11 May 2026
Resolution: Marine inspector verified vessel owner replaced 02 life ring buoys.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 4 May 2026 Resolved
Waterlights should be serviceable and batteries replaced annually if not marked with an expiration date. Waterlight was inoperable. Provide serviceable waterlight and replace battery.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2026
Resolved 11 May 2026
Resolution: Marine inspector verified the waterlight on life ring buoy is now working properly. Owner replaced the battery in the waterlight.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 4 May 2026 Resolved
A complete application for an original MMC must contain proof, documented on CG-719-K or CG-719-K/E, as appropriate, that the applicant passed all applicable vision, hearing, medical, and/or physical exams as required by subpart C of this part or a valid medical certificate issued by the Coast Guard. The Master did not have his medical certificate available.Provide master who has valid medical certificate to meet manning requirments.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2026
Resolved 11 May 2026
Resolution: Owner completed the process to renew his medical certificate and is awaiting receipt of the new card.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 May 2026 Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, the maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least 1 inch numbers and letters at the entranceway to that deck. Vessel did not have the correct number of passengers allowed posted on aft stairwell, and missing sign on front stairwell.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2026
Resolved 11 May 2026
Resolution: Marine inspector verified the maximum passenters allowed on the upper deck at one time is posted next to the ladder leading to the upper deck.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 4 May 2026 Resolved
Except as provided in 80.13(c), stations must have an authorization granted by the Federal Communications Commission. Vessel could not produce current FCC station license during annual inspection. Provide current FCC license.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2026
Resolved 11 May 2026
Resolution: Marine inspector verified a current FCC license is on board.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 3 July 2025 Resolved
Vessel's hull sustained damage while underway. Hull damage is port side chine, amidships IWO fuel tank, approx 24" long. Damaged area of hull impacts the vessel's seaworthiness and posses a potential pollution risk. Crop and renew damaged aluminum plating to the satisfaction of attending marine inspector. Adjacent integral fuel tank must be gas-free with marine chemist certificate prior to any hot work. Crop and renew must be completed prior to carrying passengers or vessel making any voyages.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 14 July 2025
Resolution: Crop and renew repairs completed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 July 2025 Resolved
Vessel's port propeller was damaged while underway. Provide servicing report from propeller shop after repairs are made to the port prop. Report must be provided prior to carrying passengers.
Action required: 705 - Other - as specified
Resolved 14 July 2025
Resolution: A spare prop was used to replace the damaged prop.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 15 April 2025 Resolved
Vessel upgraded the throttle control system after re powering the main engines. Vessel rep submitted QFA/DVTP to MSC. Once approved by MCS, preform power loss procedure to attending marine inspector.
Action required: 705 - Other - as specified
Resolved 20 May 2025
Resolution: MSC approved QFA, witnessed power failure test, all sat.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 15 April 2025 Resolved
Complete underway man overboard and fire drills.
Action required: 705 - Other - as specified
Resolved 20 May 2025
Resolution: Witnessed underway drills.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 15 April 2025 Resolved
Fire servicing company identified a failed CO2 activation pull handle. Repair pull handle.
Action required: 705 - Other - as specified
Resolved 20 May 2025
Resolution: Pull handle and cable replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 April 2025 Resolved
The emergency lighting breaker failed while testing the circuit, make repairs and prover operation of emergency lighting.
Action required: 705 - Other - as specified
Resolved 22 May 2025
Resolution: Operationally tested all emergency lighting, all sat.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 15 April 2025 Resolved
First aid kit was fond to have expired items, provide kit with updated items.
Action required: 705 - Other - as specified
Resolved 20 May 2025
Resolution: New first aid kit was provided.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 14 February 2024 Resolved
All griddles, broilers, and deep fat fryers must be fitted with a grease extraction hood in compliance with 181.425. A grease extraction hood must meet UL 710 or other standard specified by the Commandant. A grease extraction hood must be equipped with a dry or wet chemical fire extinguishing system meeting NFPA 17 or other standard specified by the Commandant, and must be listed by an independent laboratory recognized by the Commandant. Install grease extraction hood equipped with a dry or wet chemical fire extinguishing system to the satisfaction of an attending marine inspector at next credit drydock, not later than Jan 1, 2026.
Action required: 705 - Other - as specified
Due 1 January 2026
Resolved 4 May 2026
Resolution: Marine inspector confirmed vessel installed grease extraction hood equipped with a dry chemical fire extinguishing system.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 February 2024 Resolved
On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate a high water level. Two bilge alarms in the forward bunk room and aft bunk room were inoperable.
Action required: 17 - Rectify deficiencies prior to departure
Due 24 February 2024
Resolved 19 February 2024
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 15 February 2023 Resolved
Inadequate number of flares kept onboard.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 16 February 2023
Resolution: Vessel restricted to Lakes Bays and Sounds until def is rectified.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 15 February 2023 Resolved
Interconnected fire detection and alarm sensor not installed in engine room compartment.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 24 February 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 February 2023 Resolved
02 life ring buoys require replacement.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 March 2023
Resolved 20 March 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 February 2023 Resolved
Electrical panel circuit breaker slot not covered.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 March 2023
Resolved 24 February 2023
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 15 February 2023 Resolved
DAPI Program current employee not added to list.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 February 2023
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 2 June 2022 Resolved
Vessel's forward and aft berthing areas do not have a PA system. Provide a temporary method to alert people in the forward and aft berthing areas of emergencies, and submit a proposal for a permanent solution for the installation of a PA system in those berthing areas.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 June 2022
Resolution: Vessel installed a new PA installation in the two hallways of the lower berthing areas.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 2 June 2022 Resolved
Provide an up to date USCG Lights List for the vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 June 2022
Resolved 28 July 2022
Resolution: Vessel acquired applicable print outs of the 2022 light list.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 31 January 2022 Resolved
Excessive pitting found on stbd quarter in Lazarette. Repairs shall be made at next drydock period.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 20 December 2022
Resolution: Repair completed and documented in activity # 7604573.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 19 May 2021 Resolved
Each overnight accommodation space on a vessel with overnight accommodations for passengers must be fitted with an independent modular smoke detecting and alarm unit in compliance with 181.450. The 02 berthing areas on the second deck do not have adequate smoke detectors. Provide adequate smoke detectors for the second deck berthing areas.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2021
Resolved 16 July 2021
Resolution: INSTALLED
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 19 May 2021 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. Vessel's first-aid kit had several expired items. Provide valid equipment to the first-aid kit.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2021
Resolved 16 July 2021
Resolution: KIT PURCHASED
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 19 May 2021 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: Charts of large enough scale to make safe navigation possible. Vessel's charts were more than 4 years out of date. Provide update to date charts for the vessel's intended voyages.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2021
Resolved 16 July 2021
Resolution: UPDATED
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 3 June 2020 Resolved
Provide DSC capabilities for VHF radio.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 June 2020
Resolution: DSC capabilities provided.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 3 June 2020 Resolved
Provide valid STCW medical certifice for [name withheld].
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 September 2020
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 3 June 2020 Resolved
Provide valid medical certificate for Evan Kraft.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 September 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 September 2019 Resolved
Sector San Diego does not have vessels electrical plans on file. Provide a one-line electrical drawing for all A/C switchboards and distribution panels. Include all circuit loads, conductor sizes, over current protection, and max panel ratings in amps.
Action required: 705 - Other - as specified
Due 27 December 2019
Resolved 12 June 2020
Resolution: Final electrical drawing provided, verified onboard, and placed in vessel documents.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 7 September 2018 Resolved
IMO: Vsl is broadcasting no IMO #, ZERO LENGTH OR BEAM: no dimension information (AIS Antenna Position ABCD values equals 0), ZERO DRAFT: no static draft information
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 4 December 2018
Resolution: Verified in VIVS
Communications › Alarms/Indicators › Bilge Alarm
Issued 6 June 2017 Resolved
Prove proper operation of forepeak bilge alarm
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 June 2017
Resolution: Forepeak bilge alarm operational.
Navigation › Piloting/Steering › Marine Charts
Issued 6 June 2017 Resolved
Provide current and correct charts for area of operation
Action required: 705 - Other - as specified
Due 6 July 2017
Resolved 7 June 2017
Resolution: New charts provided.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 6 June 2017 Resolved
Provide batteries for identified smoke detectors in accommodation spaces.
Action required: 705 - Other - as specified
Due 6 July 2017
Resolved 7 June 2017
Resolution: Smoke detector operational.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 1 June 2009 Resolved
Ensure two life jackets are stowed in pilot house to meet requirements of SOLAS
Due 1 July 2009
Resolved 11 June 2009
Resolution: Two life jackets are now stowed in pilot house and locations is clearly marked.
Documentation › Safety Management System › Conformity Maintenance Procedures
Issued 1 June 2009 Resolved
Ensure non-conformity forms are completed/filled out using full date i.e. MM/DD/YY
Due 1 July 2009
Resolved 1 June 2009
Resolution: Trained Capt on proper use.
Documentation › Safety Management System › Reports and Analysis Procedures
Issued 1 June 2009 Resolved
Ensure SMS audits are logged and kept.
Due 1 July 2009
Resolved 1 June 2009
Resolution: Trained Capt on proper use.
Documentation › Certificates/Documents › Stability Letter
Issued 1 June 2009 Resolved
Post Stability letter at operating station/pilot house.
Due 1 July 2009
Resolved 11 June 2009
Resolution: Stability letter is now posted at operating station/pilot house.
Documentation › Markings/Placards › Garbage Placard
Issued 1 June 2009 Resolved
Obtain and post waste management plan.
Due 1 July 2009
Resolved 11 June 2009
Resolution: waste management plan is posted
Documentation › Logs/Records › Drug Test Records
Issued 2 June 2008 Resolved
Provide pre-employment drug test results for Andre Kovacs and ensure he is included on the random drug testing crew list prior to his getting underway.
Action required: 705 - Other - as specified
Due 15 June 2008
Resolved 13 June 2008
Fire Fighting › Fire Pumps › Capacity
Issued 2 June 2008 Resolved
Ensure fire pump has required 60 psi of pressure.
Action required: 705 - Other - as specified
Due 15 June 2008
Resolved 13 June 2008
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 2 June 2008 Resolved
Replace stern light lens cover.
Action required: 705 - Other - as specified
Due 15 June 2008
Resolved 13 June 2008
Navigation › Piloting/Steering › Marine Charts
Issued 2 June 2008 Resolved
Provide currently corrected chart of SD Bay and approach.
Action required: 705 - Other - as specified
Due 15 June 2008
Resolved 13 June 2008
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 2 June 2008 Resolved
Ensure fixed CO2 F/F system controls (pressure switches) are located outside the space protected (E/R).
Action required: 705 - Other - as specified
Due 1 February 2009
Resolved 1 June 2009
Resolution: Pressure switches moved outside of engine room space.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 30 May 2007 Resolved
Provide proof of crew enrollment in random drug testing program and pre-employment tests for (3) new crewmembers.
Action required: 705 - Other - as specified
Due 30 June 2007
Resolved 1 June 2007
Engineering › Sea-water System (primary cooling) › Piping
Issued 30 May 2007 Resolved
Install adequate strainer in raw water intake line for center and port MDEs.
Action required: 705 - Other - as specified
Due 30 June 2007
Resolved 6 June 2007
Fire Fighting › Means of Escape › Escape Route Signs
Issued 30 May 2007 Resolved
Mark on both sides the emergency exits from accommodation spaces with "Emergency Exit, Keep Clear" in 2" letters.
Action required: 705 - Other - as specified
Due 30 June 2007
Resolved 6 June 2007
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 30 May 2007 Resolved
Update instructions for fixed CO2 fire-fighting system at remote pull station.
Action required: 705 - Other - as specified
Due 30 June 2007
Resolved 6 June 2007
Navigation › Piloting/Steering › Marine Charts
Issued 30 May 2006 Resolved
Replace outdated navigational chart, coast pilot, light list with new editions and provide current updates.
Due 15 June 2006
Resolved 31 May 2006
Resolution: Purchased all new charts & pubs.
Fire Fighting › Grease Extraction Hood › General
Issued 30 May 2006 Resolved
Clean dust & lint buildup inside vents & covers on the galley hood system.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 May 2006
Resolution: Hood system thoroughly cleaned.
Documentation › Certificates/Documents › FCC SSL
Issued 30 May 2006 Resolved
Provide FCC Radio Certificate of Compliance.
Action required: 705 - Other - as specified
Resolved 31 May 2006
Resolution: Proof of current FCC certs provided.
Construction/Loadline › Hull › Longitudinal Frame
Issued 19 April 2006 Resolved
Repair 3 small cracks in welds on port side in forepeak.
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 May 2006
Resolved 8 May 2006
Electrical › Electrical Distribution System (service)
Issued 28 May 2003 Resolved
Install metallic wire supports at 24" intravals on all horizonal overhead wire runs in the Engine Room. IAW 46 CFR 183.340(b)(4) LEGACY COMPONENT DESC: Cable
Due 28 June 2003
Resolved 13 June 2003
Engineering › Bilge Water Management System
Issued 28 May 2003 Resolved
Label bilge manifold in Engine Room by which compartment each suction line services. LEGACY COMPONENT DESC: Manifold
Due 28 June 2003
Resolved 13 June 2003
Construction/Loadline › Hull
Issued 22 April 2003 Resolved
Repair (04) identified cracked welds in forepeak to satisfaction of attending marine inspector. LEGACY COMPONENT DESC: Weld
Condition: Unknown
Action required: 705 - Other - as specified
Due 22 May 2003
Resolved 13 June 2003
Electrical
Issued 11 May 1999 Resolved
Clean generator, portside engine room.
Condition: Unknown
Due 21 May 1999
Resolved 21 May 1999
Electrical
Issued 11 May 1999 Resolved
Submit wiring plan for new electrical conversion and generator install.
Condition: Unknown
Due 21 May 1999
Resolved 21 May 1999
Navigation
Issued 11 May 1999 Resolved
Install pin nuts or locking pin on steering system.
Condition: Unknown
Due 17 June 1999
Resolved 21 June 1999
Electrical
Issued 11 May 1999 Resolved
Clean engine room exhaust fan.
Condition: Unknown
Due 21 May 1999
Resolved 21 May 1999
Construction/Loadline
Issued 11 May 1999 Resolved
Provide list of all sea valves.
Condition: Unknown
Due 21 May 1999
Resolved 21 May 1999
Engineering
Issued 11 May 1999 Resolved
Repair top mounts for engine room lube oiltank. Note: owner may be installing smaller lube oil tank. Current tank is 200gals.
Condition: Unknown
Due 21 May 1999
Resolved 21 May 1999
Fire Fighting
Issued 5 June 1997 Resolved
Amend operating instructions to include "evecuate personnel and secure all operating engines in space" prior to discharge._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 6 June 1997
Resolved 11 June 1997
Lifesaving
Issued 5 June 1997 Resolved
properly stencil "Distress Signals" on both flare containers. Also paint the green container a bright orange color prior to stenciling._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 6 June 1997
Resolved 11 June 1997
Lifesaving
Issued 5 June 1997 Resolved
Provide life jacket donning placard._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 6 June 1997
Resolved 11 June 1997
Documentation
Issued 5 June 1997 Resolved
Provide FCC servicing documentation._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 6 June 1997
Resolved 8 July 1997
Documentation
Issued 5 June 1997 Resolved
Provide MARPOL V garbage plan._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 6 June 1997
Resolved 8 July 1997
Fire Fighting
Issued 5 June 1997 Resolved
Amend operating instructions for CO2 system to include:"Ensure no personnelare in space and secure all operating engines."_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 6 June 1997
Resolved 8 July 1997
Lifesaving
Issued 5 June 1997 Resolved
Properly stencil "Distress Signals" on both flare containers and paint the green container a bright orange color prior to stenciling. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 6 June 1997
Resolved 8 July 1997
Lifesaving
Issued 5 June 1997 Resolved
Provide life jacket donning placard._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 6 June 1997
Resolved 8 July 1997
Engineering
Issued 14 July 1994 Resolved
REPAIR INOPERABLE LUBE OIL TEMPERATURE GAUGES FOR MAIN DIESEL ENGINES ON _x001C_ THE BRIDGE. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 July 1994
Resolved 14 July 1994
Engineering
Issued 7 June 1994 Resolved
LUBE OIL TEMP GUAGES ON BRIDGE FOR ALL THREE MDE HANE BEEN DISCONNECTED ANDWILL BE RECONNECTED AT NEXT OIL CHANGE.
Condition: Unknown
Due 7 June 1994
Resolved 7 June 1994
Electrical
Issued 7 May 1993 Resolved
PROVIDE METAL CABLE SUPPORTS EVERY TWO FEET FOR CABLE RUNS IN ENGINEROOM.
Condition: Unknown
Due 7 May 1993
Resolved 7 May 1993
Fire Fighting
Issued 15 May 1990 Resolved
PROVIDE PROPER INTRUCTION PLACARD ON EMERGENCY RELEASE OF FIXED CO2 SYS. FOR THE ENGINE ROOM. THE PLACARD SHOULD BE LOCATED IN THE VICINITY OF THE REMOTE PULL STATION.
Condition: Unknown
Due 15 May 1990
Resolved 15 May 1990
Engineering
Issued 15 May 1990 Resolved
PROVIDE FLAME SHIELDS TO TWO(2) FUEL OIL FILTERS IN THE ENGINE ROOM.
Condition: Unknown
Due 15 May 1990
Resolved 15 May 1990
Engineering
Issued 1 June 1989 Resolved
CONDUCT OPERATIONAL TESTING OF THE STARBOARD MAIN PROPULSION ENGINE AFTER COMPLETING REPAIR TO VIBRATION DAMPER.
Condition: Unknown
Due 1 June 1989
Resolved 1 June 1989
Construction/Loadline
Issued 11 May 1987 Resolved
REPAIR CRACKED WELDS ON SIDE LONGITUDENALS AT SIDE SHELL STBD AFT IN STEERING COMPARTMENT NEXT TO TRANSOM.
Condition: Unknown
Due 11 May 1987
Resolved 11 May 1987
Lifesaving
Issued 11 May 1987 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 11 May 1987
Resolved 11 May 1987
Navigation
Issued 30 April 1986 Resolved
PROVIDE TIDE TABLES AND LIGHT LIST
Condition: Unknown
Due 30 April 1986
Resolved 30 April 1986
Documentation
Issued 30 April 1986 Resolved
PROVIDE FCC RADIO STATION LICENSE
Condition: Unknown
Due 30 April 1986
Resolved 30 April 1986
Accommodation/Occupational Safety
Issued 30 April 1986 Resolved
STENCIL VENT CLOSURE LEVER FOR ER SUPPLY VENT
Condition: Unknown
Due 30 April 1986
Resolved 30 April 1986
Accommodation/Occupational Safety
Issued 30 April 1986 Resolved
PROVIDE ENGINE ROOM EXHAUST VENT TO BILGE AREA
Condition: Unknown
Due 30 April 1986
Resolved 30 April 1986
Fire Fighting
Issued 30 April 1986 Resolved
INSTALL DIRT TRAP IN FIXED CO2 DISCHARGE PIPING
Condition: Unknown
Due 30 April 1986
Resolved 30 April 1986
Construction/Loadline
Issued 30 April 1986 Resolved
PROVIDE CAPTURE CHAINS ON ALL FLUSH DECK HATCHES
Condition: Unknown
Due 30 April 1986
Resolved 30 April 1986
Fire Fighting
Issued 30 April 1986 Resolved
PROVIDE HAND HELD FIRE PUMP
Condition: Unknown
Due 30 April 1986
Resolved 30 April 1986
Documentation
Issued 27 June 1985 Resolved
POST STABILITY LETTER AFTER RECEIVED FROM MMT12.(NEW STABILITY LETTER BEING ISSUED DUE TO WEIGHT CHANGES ON VESSEL. VESSEL IS RESTRICTED TO 30 PASSENGERS UNTIL STABILITY REVIEW IS COMPLETED
Condition: Unknown
Due 27 June 1985
Resolved 27 June 1985
Fire Fighting
Issued 8 February 1985 Resolved
PROVIDE 1 ADDITIONAL FIXED POWER FIRE PUMP.
Condition: Unknown
Due 8 February 1985
Resolved 8 February 1985
Documentation
Issued 8 February 1985 Resolved
HAVE A LOADLINE ASSIGNED AND MARK THE SAME ON THE VESSEL'S HULL.
Condition: Unknown
Due 8 February 1985
Resolved 8 February 1985
Construction/Loadline
Issued 8 February 1985 Resolved
PROPERLY MARK THE VESSEL'S DRAFT MARKS.
Condition: Unknown
Due 8 February 1985
Resolved 8 February 1985
Accommodation/Occupational Safety
Issued 8 February 1985 Resolved
RE-INSTALL THE SECOND MEANS OF ESCAPE, (LOCATED AFT) FOR THE LOWER ACCOMODATIONS.
Condition: Unknown
Due 8 February 1985
Resolved 8 February 1985
Accommodation/Occupational Safety
Issued 8 February 1985 Resolved
RE-INSTALL AND DEMONSTRATE THE PROPER OPERATION OF THE MARINE SANITATION DEVICE.
Condition: Unknown
Due 8 February 1985
Resolved 8 February 1985
Accommodation/Occupational Safety
Issued 8 February 1985 Resolved
PROPERLY REPAIR/REPLACE THE DISCONTINUED PIPING LOCATED AT THE AFTER BULK- HEAD OF THE FORWARD ACCOMODATIONS BILGE.
Condition: Unknown
Due 8 February 1985
Resolved 8 February 1985
Electrical
Issued 8 February 1985 Resolved
PROVIDE ADDITIONAL LIGHT BULBS FOR THE EXIT SIGN LOCATED ON THE AFTER BULK-HEAD OF THE FORWARD ACCOMODATIONS.
Condition: Unknown
Due 8 February 1985
Resolved 8 February 1985
Fire Fighting
Issued 8 February 1985 Resolved
PROVIDE 2 FIRE HOSES IN 50' LENGTHS THAT MEET EITHER UNDERWRITER'S LAB. STANDARD #19 OR FEDERAL SPECIFICATION ZZ-H-451-E.
Condition: Unknown
Due 8 February 1985
Resolved 8 February 1985
Electrical
Issued 8 February 1985 Resolved
PROVIDE THE FOLLOWING INFORMATION FOR THE NEWLY INSTALLED FIRE PUMP, 2 BAITPUMPS, AND THE HEAD PUMP FOR REVIEW AND APPROVAL:(A) WIRING TYPE AND SIZE, (B) BRANCH CIRCUIT OVERCURRENT PROTECTION, (C) MOTOR RUNNING OVERCURRENT PROTECTION.
Condition: Unknown
Due 8 February 1985
Resolved 8 February 1985
Accommodation/Occupational Safety
Issued 8 February 1985 Resolved
SUBJECT THE SANITARY AND BAIT PIPING SYSTEMS TO A WORKING PRESSURE HYDROSTATIC TEST.
Condition: Unknown
Due 8 February 1985
Resolved 8 February 1985
Documentation
Issued 8 February 1985 Resolved
PROVIDE A VALID STABILITY LETTER
Condition: Unknown
Due 8 February 1985
Resolved 8 February 1985
Accommodation/Occupational Safety
Issued 8 February 1985 Resolved
BRING THE PASSENGERS ACCOMODATIONS INTO A HABITABLE FORM.
Condition: Unknown
Due 8 February 1985
Resolved 8 February 1985
Accommodation/Occupational Safety
Issued 8 February 1985 Resolved
REMOVE ALL EXTRANEOUS MATERIAL FROM THE VESSEL'S MAIN DECK.
Condition: Unknown
Due 8 February 1985
Resolved 8 February 1985
Documentation
Issued 8 February 1985 Resolved
PROVIDE A VALID CERTIFICATE OF DOCUMENTATION
Condition: Unknown
Due 8 February 1985
Resolved 8 February 1985
Navigation
Issued 8 February 1985 Resolved
PROVIDEW NAVIGATIONAL PLOTTING EQUIPMENT.
Condition: Unknown
Due 8 February 1985
Resolved 8 February 1985
Electrical
Issued 8 February 1985 Resolved
REPAIR/REPLACE THE 24 VOLT LIGHTING SYSTEM LOCATED IN THE FORWARD AND AFTERBELOW DECK ACCOMODATIONS.
Condition: Unknown
Due 8 February 1985
Resolved 8 February 1985

Casualty record · 2

28 October 2009Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3645397
7 October 2012Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4501817
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.