Records from 1985 to 2005. Most recent: inspection, 15 June 2005.
Documentation record
Registered dimensions (L × B × D)47.8 ft × 15.2 ft × 6.3 ft
Registered tonnagegross 35 / net 24
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDELTA MARINE INDUSTRIES, INC · SEATTLE, WA, UNITED STATES · built 1976
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEWPORT BEACH, CA
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it35 - Regulatory (Subpart C or D), Gross Ton
24 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 33
15 June 2005
Construction Oversight
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2077776
2 May 2003
Hull Examination · Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1839170
22 March 2003
Type not recorded
No type recorded · Station Seattle · USCG Northwest District (CGD-NW) · Activity 1761685
10 April 2002
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1602826
27 September 2001
Simplified Stability Test
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 772981
22 September 2001
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 68110
27 July 2001
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1429618
14 April 2001
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1366414
6 April 2001
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1391533
19 May 2000
Re-Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1441713
2 May 2000
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1787927
19 April 1999
Deficiency Check · MARPOL Annex V Examination · COI Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1360831
9 April 1999
Hull Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1454662
5 June 1998
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1426105
15 May 1997
MARPOL Annex V Examination · Re-Inspection · Hull Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1400596
17 May 1996
Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1077517
8 May 1996
COI Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1359165
9 May 1995
Re-Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1382935
28 April 1995
Hull Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1374270
16 May 1994
Re-Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1379980
18 May 1993
COI Inspection · Hull Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1359586
13 May 1992
Re-Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 956281
8 January 1992
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1261129
3 December 1991
Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 949826
17 May 1991
Hull Examination · Re-Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1246609
24 May 1990
COI Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 901353
11 May 1989
Hull Examination · Re-Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1044037
25 May 1988
Re-Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1195644
27 May 1987
Hull Examination · COI Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1334654
10 June 1986
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1327424
2 May 1986
Re-Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 988792
25 November 1985
Credit Drydock
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 995210
27 May 1985
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1291620
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 2 May 2003
Resolved
AUTO SHUTDOWN FAILED TO SHUTDOWN MDE'S
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 May 2003
Resolved 17 June 2003
Resolution: ELECTRITION FOUND CORRODED WIRE REPLACED SYSTEM FUCTION SAT.
Documentation
Issued 27 July 2001
Resolved
CONDUCT A SATIFACTORY SIMPLIFIED STABILITY TEST
Condition: Unknown
Due 12 October 2001
Resolved 12 October 2001
Navigation
Issued 14 April 2001
Resolved
PROVE PROPER OPERATION OF SOUND SIGNAL(SHIP'S WHISTLE)_x001C_
Condition: Unknown
Due 14 April 2001
Resolved 18 June 2001
Navigation
Issued 14 April 2001
Resolved
PROVE PROPER OPERATION OF STERNLIGHT
Condition: Unknown
Due 14 April 2001
Resolved 18 June 2001
Fire Fighting
Issued 14 April 2001
Resolved
MOUNT ALL PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 14 April 2001
Resolved 18 June 2001
Lifesaving
Issued 14 April 2001
Resolved
PROPERLY STOW AND MARK STOWAGE OF LIFEJACKETS.
Condition: Unknown
Due 14 April 2001
Resolved 18 June 2001
Fire Fighting
Issued 14 April 2001
Resolved
PROVIDE 3 FIRE BUCKETS.
Condition: Unknown
Due 14 April 2001
Resolved 18 June 2001
Lifesaving
Issued 14 April 2001
Resolved
PROVIDE 2 ORANGE SMOKE FLARES.
Condition: Unknown
Due 14 April 2001
Resolved 18 June 2001
Engineering
Issued 19 April 1999
Resolved
Make proper repairs to fuel leak's in lazerette and to pulse pump in E-roomprior to carrying passengers.
Condition: Unknown
Due 23 April 1999
Resolved 26 April 1999
Navigation
Issued 5 June 1998
Resolved
Procure latest ed. of nav rules.
Condition: Unknown
Due 15 June 1998
Resolved 5 August 1998
Electrical
Issued 5 June 1998
Resolved
Re-hang wiring bundles in E-room overhead w/acceptable hangers.
Condition: Unknown
Due 15 June 1998
Resolved 5 August 1998
Engineering
Issued 5 June 1998
Resolved
Re-stencil fuel shutoff access plates.
Condition: Unknown
Due 15 June 1998
Resolved 5 August 1998
Electrical
Issued 5 June 1998
Resolved
Replace extension cord to battery charger with min 14 AWG hardwired.
Condition: Unknown
Due 15 June 1998
Resolved 5 August 1998
Lifesaving
Issued 5 June 1998
Resolved
Stencil PFD storage w/ size-quantity prior to carrying pax.
Condition: Unknown
Due 15 June 1998
Resolved 5 August 1998
Engineering
Issued 15 May 1997
Resolved
Stencil remote fuel shut off valves with contrasting color, 1/2" minimum.
Condition: Unknown
Due 30 May 1997
Resolved 3 July 1997
Lifesaving
Issued 15 May 1997
Resolved
Mount CG approved 1st aid kit._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 May 1997
Resolved 3 July 1997
Construction/Loadline
Issued 15 May 1997
Resolved
Prove proper operation of engineroom installed bilge eductor._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 May 1997
Resolved 3 July 1997
Lifesaving
Issued 15 May 1997
Resolved
Paint flare storage box red, stencil contrasting letters.
Condition: Unknown
Due 30 May 1997
Resolved 3 July 1997
Engineering
Issued 8 May 1996
Resolved
Replace hose section on port and starboard fuel fill.
Condition: Unknown
Due 8 May 1996
Resolved 8 May 1996
Documentation
Issued 8 May 1996
Resolved
Purchase current charts for operating area.
Condition: Unknown
Due 8 May 1996
Resolved 8 May 1996
Engineering
Issued 8 May 1996
Resolved
Tighten fuel fittings where weeping in engineroom._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 May 1996
Resolved 8 May 1996
Fire Fighting
Issued 8 May 1996
Resolved
Mount F/E in engineroom.
Condition: Unknown
Due 8 May 1996
Resolved 8 May 1996
Lifesaving
Issued 8 May 1996
Resolved
Replace weaklink on lifefloat with proper rated link, < 20 POB.
Condition: Unknown
Due 8 May 1996
Resolved 8 May 1996
Navigation
Issued 17 May 1991
Resolved
PORT AND STARBOARD RUNNING LIGHTS ARE NOT APPROVED TYPES.
Condition: Unknown
Due 30 June 1991
Resolved 12 July 1991
Documentation
Issued 17 May 1991
Resolved
FCC FORM 824 MISSING.
Condition: Unknown
Due 30 June 1991
Resolved 12 July 1991
Navigation
Issued 17 May 1991
Resolved
Port rudder is worn.
Condition: Unknown
Due 17 May 1991
Resolved 17 May 1991
Lifesaving
Issued 2 May 1986
Resolved
REPLACE LIFE-FLOAT WITH ONE OF EQUAL SIZE.
Condition: Unknown
Due 2 May 1986
Resolved 2 May 1986