Inspection history · 30
12 May 2026
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8390859
14 April 2026
Internal Structural Exam · Hull Examination
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8349645
5 May 2025
COI Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8113864
20 November 2024
In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8037727
8 May 2024
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7913683
28 November 2023
Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7830520
26 September 2023
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7806978
27 July 2023
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7756766
19 December 2022
Liferaft Servicing
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7610985
5 October 2022
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7575778
19 April 2022
Administrative Inspection · Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7434892
14 February 2022
Liferaft Servicing
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7396053
13 September 2021
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7339392
3 December 2020
Hull Examination
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7107378
24 September 2020
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7064895
20 July 2020
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7011451
28 May 2020
COI Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6962581
11 December 2019
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6873478
30 October 2019
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6845541
11 April 2019
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6667732
5 December 2018
Liferaft Servicing
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6599624
5 December 2018
Liferaft Servicing
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6619884
4 December 2018
Liferaft Servicing
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6619891
7 November 2018
Liferaft Servicing
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6599680
25 September 2018
Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6547663
13 September 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6539913
29 September 2017
Examination of Repairs · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6277766
1 June 2017
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6167167
20 October 2016
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6035457
14 April 2016
In-Service Inspection · Plan Review "T" Boat · Administrative Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5873575
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 5 May 2025
Resolved
Found the top of the water tight bulkhead in the #2 void cracked appx 1/2 inch from the bottom of the deck support frame in which the weld was also cracked. Discussed weld plan to dye pen, w/ drill stop and v out and reweld.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2025
Resolved 9 May 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 September 2023
Resolved
Vessel is documented as THE HOPE, add THE to life jackets and life rings onboard the vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 October 2023
Resolved 13 November 2023
Resolution: corrected.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 26 September 2023
Resolved
CO2 pull station for fixed system in the engine room needs to be labeled as such.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 October 2023
Resolved 13 November 2023
Resolution: corrected.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 5 October 2022
Resolved
Found vessel's charts out of date and in need of update.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 November 2022
Resolved 28 November 2023
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 5 October 2022
Resolved
Found numerous cracks in the forepeak.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 November 2022
Resolved 28 November 2023
05 - Radio Communications › N/A - No Subsystem › Radio log (diary)
Issued 5 October 2022
Resolved
Found epirb checks not being logged.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 November 2022
Resolved 28 November 2023
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 13 September 2021
Resolved
Vessel only has 8 flares on board, GL route requires 12.
Action required: 10 - Deficiency Rectified
Due 27 September 2021
Resolved 13 September 2021
Resolution: corrected.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 13 September 2021
Resolved
Bilge alarm panel audible alarm not functioning.
Action required: 10 - Deficiency Rectified
Due 27 September 2021
Resolved 13 September 2021
Resolution: corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 September 2021
Resolved
Topside RLB deteriorated, requires replacement.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 October 2021
Resolved 26 October 2021
Resolution: replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 September 2021
Resolved
Port quarter electrical outlet damaged, must be replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 September 2021
Resolved 26 October 2021
Resolution: replaced.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 13 September 2021
Resolved
CO2 system requires simple instructions at the bottles.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 October 2021
Resolved 19 April 2022
Resolution: corrected.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 11 June 2020
Resolved
Replace expired EPIRB battery. Vessel limited to operations NMT 3 NM from land until corrected.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 July 2020
Resolved 24 September 2020
Resolution: Corrected.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 11 June 2020
Resolved
Repair inop stbd running light. vessel limited to daytime operations; no limited visibility ops.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2020
Resolved 9 July 2020
Resolution: corrected.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 11 June 2020
Resolved
Provide proof of recent drills & training.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2020
Resolved 25 June 2020
Resolution: completed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 June 2020
Resolved
Exhaust lagging on both inboard MDE turbo chargers loose, must be tightened.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2020
Resolved 25 June 2020
Resolution: corrected.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 30 October 2019
Resolved
Repair cracked welds at the base of the stanchion in the forward frame in the Forepeak prior to next operating season. 46 CFR 176.700
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 May 2020
Resolved 13 December 2019
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 30 October 2019
Resolved
Repair welds at two frame connections on the starboard side of the second void prior to next operating season. 46 CFR 176.700
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 May 2020
Resolved 13 December 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 September 2018
Resolved
Lifebuoys must be readily available to be cast loose. Lifebuoy at aft main deck is obstructed and difficult to deploy as mounted and must be relocated and stowed properly before 09OCT2018 to the satisfaction of the attending marine inspector.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 October 2018
Resolved 25 October 2018
Resolution: RLB mounted in new location on aft deck, def corrected.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 25 September 2018
Resolved
Fixed Fire Extinguishing systems must be securely mounted. Starboard CO2 cylinder is loose in mountings and must be secured to prevent shifting or rotating prior to 09OCT2018 to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 October 2018
Resolved 25 October 2018
Resolution: corrected.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 25 September 2018
Resolved
Lifejacket donning placards must be provided in view of crew and passengers. Donning placard for 2nd deck passenger area must be posted in plain view of passengers, before 09OCT2018 to the satisfaction of the attending marine inspector.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 October 2018
Resolved 25 October 2018
Resolution: corrected.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 13 September 2018
Resolved
The vessel is currently broadcasting (1) Improper Call Sign, (2) Zero Length and Beam (3) Zero Draft, (4) No Ship Type. Ship Type should be 60 per the US Official Encoding guide.
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 October 2018
Resolved 1 May 2019
Resolution: Received notification of AIS broadcasting correction from vessel owner. Verified no errors in VIVS.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 12 October 2017
Resolved
Provide adequate mountings and support for insulation materials in way of fuel tank space and clean up loose insulation debris to prevent clogging of bilge strainers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 November 2017
Resolved 25 September 2018
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 12 October 2017
Resolved
Provide means to prevent longitudinal movement of both fuel oil tanks.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 November 2017
Resolved 11 April 2019
Resolution: permanent fuel tank chocking system installed.
Engineering › Steering Gear System › Linkage
Issued 29 September 2017
Resolved
Helm excessively loose on hand hydraulic unit at operating station. Corrected prior to operation during inspection.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 October 2017
Resolved 12 October 2017
Resolution: resolved during inspection
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 29 September 2017
Resolved
Discharge hoses excessively loose on cylinders control heads after recent servicing, corrected during inspection.
Condition: Improper/Lack of Maintenance
Due 10 October 2017
Resolved 10 October 2017
Resolution: corrected during inspection
Communications › Alarms/Indicators › Bilge Alarm
Issued 29 September 2017
Resolved
Bilge alarm audible signal inoperable, corrected during inspection.
Condition: Improper/Lack of Maintenance
Due 12 October 2017
Resolved 12 October 2017
Resolution: corrected during inspection.
Documentation › Certificates/Documents › Stability Letter
Issued 20 October 2016
Resolved
Post stability letter and EP's in pilothouse.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 1 June 2017
Resolution: Sighted.
Communications › Radio Communications › VHF Radiotelephone
Issued 20 October 2016
Resolved
Provide radio inspection certificate.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 1 June 2017
Resolution: Sighted.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 20 October 2016
Resolved
Provide Sr. deckhand desination letter/list for this vessel and entire company.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 15 May 2017
Resolution: Cleared, entered in error.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Pressure
Issued 20 October 2016
Resolved
Replace pilothouse fire ext. with properly charged extinguisher.
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 October 2016
Resolved 20 October 2016
Resolution: Replaced extinguisher with properly charged ext.
Communications › Radio Communications › EPIRB
Issued 20 October 2016
Resolved
[name withheld] with vessel name.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 1 June 2017
Resolution: Corrected.
Communications › Radio Communications › EPIRB
Issued 20 October 2016
Resolved
Replace expired hydrostatic release. Vessel limited to no more than 3 miles from land.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 1 June 2017
Resolution: Replaced.
Construction/Loadline › Hull › Weld
Issued 20 October 2016
Resolved
Repair cracked welds in forepeak as marked.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 1 June 2017
Resolution: Corrected.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 20 October 2016
Resolved
Replace inoperative float light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 October 2016
Resolved 20 October 2016
Resolution: Float light replaced with new operational light.