Records from 1983 to 1998. Most recent: inspection, 6 November 1998.
Inspection history · 55
6 November 1998
Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1470961
31 August 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 769727
25 July 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 201417
25 March 1998
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 786921
2 January 1998
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 784385
15 December 1997
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 780249
10 November 1997
Deficiency Check · Letter of Compliance (Initial/Renewal)
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1402557
17 September 1997
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 40906
2 September 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1120203
24 June 1997
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 40142
28 May 1997
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1108259
20 April 1997
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 690099
20 February 1997
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1105353
10 February 1997
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 201416
10 February 1997
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1105748
13 December 1996
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1091292
13 December 1996
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1091294
13 December 1996
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1091299
12 November 1996
Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1406014
12 November 1996
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1425829
8 February 1996
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1357784
14 January 1994
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1184879
2 July 1993
Permit to Proceed
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1152517
27 August 1992
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 30020
21 June 1989
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1348405
23 May 1989
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1196757
6 April 1989
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1204660
26 January 1989
Deficiency Check · Drydock Extension
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1034862
4 January 1989
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1044436
7 December 1988
Deficiency Check · Drydock Extension
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1033893
13 October 1988
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 887368
30 August 1988
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1347227
20 October 1987
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1022771
7 October 1987
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1013313
12 August 1987
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1032011
13 March 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1325309
4 March 1987
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1319017
18 February 1987
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1007396
23 January 1987
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1009727
30 November 1986
Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1025662
7 September 1986
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1011344
4 August 1986
Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1306561
6 June 1986
Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 995660
5 May 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1299039
5 May 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1312501
28 April 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1298856
19 February 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 989046
31 January 1986
Credit Drydock
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1294214
20 August 1985
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 991811
10 October 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1288462
21 August 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 974930
1 February 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 970767
8 December 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 970766
19 October 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1279974
16 August 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 967459
Electrical
Issued 6 November 1998
Resolved
SECURE WIRING WITH METAL BANDING, REMOVE DEAD-END WIRING, PROPERLY MOUNT LOOSE J-BOX, REPLACE MISSING BOLTS ON EXPLOSION PROOF BOXES, AND MOUNT LOOSE SPEAKER ON DRILL FLOOR.
Condition: Unknown
Due 16 November 1998
Resolved 16 November 1998
Accommodation/Occupational Safety
Issued 6 November 1998
Resolved
PROPERLY PROVIDE OVERHEAD CEILING COVERING IN STATEROOMS ABOVE BERTHS TO ENCLOSE EXPOSED INSULATION.
Condition: Unknown
Due 16 November 1998
Resolved 16 November 1998
Fire Fighting
Issued 6 November 1998
Resolved
INSTALL PROPER A-CLASS FIRE DOOR TO GALLEY ENTRANCE IN PASSAGEWAY WHERE LOUVERED DOOR IS INSTALLED. INSTALLATION SHALL BE IN ACCORDANCE WITH SOLAS1974, CHAPTER II-2, REGULATION 47.
Condition: Unknown
Due 16 November 1998
Resolved 16 November 1998
Fire Fighting
Issued 6 November 1998
Resolved
REPAIR OR REPLACE GENERAL ALARM BELLS ON THE DRILL FLOOR, SHALE SHAKER AREAAND ALONG THE PASSAGEWAY IN THE ACCOMODATION AREAS.
Condition: Unknown
Due 5 January 1999
Resolved 5 January 1999
Deck/Cargo
Issued 6 November 1998
Resolved
CONDUCT ANNUAL CRANE SURVEY BY A CERTIFIED AUTHORITY AND SUBMIT EXAM REPORTTO [name withheld].
Condition: Unknown
Due 7 December 1998
Resolved 7 December 1998
Fire Fighting
Issued 6 November 1998
Resolved
REMOVE FROM SERVICE, STAINLESS STEEL SODA-ACID PORTABLE FIRE EXTINGUISHERS FROM SERVICE. PROVIDE PROPER PORTABLE EXTINGUISHER BRACKETS ON INTERIOR UNITS.
Condition: Unknown
Due 16 November 1998
Resolved 16 November 1998
Electrical
Issued 6 November 1998
Resolved
IN THE MUD PIT ROOM, REPLACE MISSING BOLTS IN EXPLOSION PROOF FITTINGS, MOUNT LOOSE J-BOX AND MAKE MUD PIT DOORS GAS TIGHT AND SELF CLOSING.
Condition: Unknown
Due 16 November 1998
Resolved 16 November 1998
Deck/Cargo
Issued 6 November 1998
Resolved
REPAIR TRANSMISSION FLUID LEAKS IN BOTH CRANES.
Condition: Unknown
Due 7 December 1998
Resolved 7 December 1998
Electrical
Issued 6 November 1998
Resolved
IN THE EMERGENCY GENERATOR COMPARTMENT, PROVIDE COVERS FOR MISSING BREAKERS, PROPERLY SECURE FLEX FUEL OIL HOSE, REPAIR BATTERY POWERED "E" LIGHT AND POST CO2 SYSTEM OPERATING INSTRUCTIONS.
Condition: Unknown
Due 16 November 1998
Resolved 16 November 1998
Electrical
Issued 6 November 1998
Resolved
REMOVE OR PROPERLY TERMINATE DEAD END WIRING THROUGHOUT RIG AS NECESSARY.
Condition: Unknown
Due 16 November 1998
Resolved 16 November 1998
Lifesaving
Issued 6 November 1998
Resolved
REPAIR OR REPLACE AND PROPERLY SECURE, ELECTRICAL CABLES TO LIFEBOAT NO.1 AND 2.
Condition: Unknown
Due 16 November 1998
Resolved 16 November 1998
Construction/Loadline
Issued 6 November 1998
Resolved
REPLACE MISSING AND BROKEN DOG HANDLES ON WATERTIGHT HATCHES THROUGHOUT RIGAS NECESSARY.
Condition: Unknown
Due 16 November 1998
Resolved 16 November 1998
Lifesaving
Issued 6 November 1998
Resolved
CROP AND RENEW WASTED HANDRAIL AT TOP OF LADDER TO DRILL FLOOR ENTRANCE.
Condition: Unknown
Due 16 November 1998
Resolved 16 November 1998
Unknown
Issued 6 November 1998
Resolved
TIGHTEN OR RENEW PACKING MATERIAL TO STARBOARD FIRE PUMP AND ENGINE COOLINGPUMP IMPELLER SHAFTS IN STARBOARD COLUMN.
Condition: Unknown
Due 16 November 1998
Resolved 16 November 1998
Electrical
Issued 6 November 1998
Resolved
PROPERLY INSTALL BUSHINGS ON WIRE CABLE AT BULKHEAD PENETRATIONS IN LAUNDRYROOM TO DRYER BREAKERS.
Condition: Unknown
Due 16 November 1998
Resolved 16 November 1998
Lifesaving
Issued 6 November 1998
No resolution recorded
CONDUCT OPERATIONAL TEST OF LIFEBOAT RELEASE GEAR UNDER A LOAD OF 110% OR AN ALTERNATE TEST ACCEPTABLE TO THE COGNIZANT OCMI.
Condition: Unknown
Due 31 March 2000 — due date passed with no resolution recorded
Electrical
Issued 10 November 1997
Resolved
IDENTIFY AND PROPERLY LABEL #3 BREAKER IN MECHANIC'S SHOP
Condition: Unknown
Due 15 December 1997
Resolved 2 December 1997
Documentation
Issued 10 November 1997
Resolved
IMPLEMENT NEW 108 AND 109 SECTION.
Condition: Unknown
Due 10 November 1997
Resolved 10 November 1997
Electrical
Issued 10 November 1997
Resolved
PROVIDE BLANK FOR REMOVED THRUSTER 600V AUX FEEDER BREAKER IN SCR ROOM.
Condition: Unknown
Due 10 November 1997
Resolved 10 November 1997
Electrical
Issued 10 November 1997
Resolved
PROPERLY LABEL AND PROVIDE (1) BLANK FOR PANEL IN STBD PASSAGE FORWARD (STBD BOW [name withheld])
Condition: Unknown
Due 10 November 1997
Resolved 10 November 1997
Lifesaving
Issued 10 November 1997
Resolved
PROVIDE MORE VOLUME FOR SACK ROOM EYEWASH STATION
Condition: Unknown
Due 10 November 1997
Resolved 10 November 1997
Construction/Loadline
Issued 10 November 1997
Resolved
MAKE GASTIGHT STUFFING TUBE BETWEEN MUD PUMP AND MUD PIT ROOMS WHERE LOGGING LINES PENETRATE BULKHEAD.
Condition: Unknown
Due 10 November 1997
Resolved 10 November 1997
Electrical
Issued 10 November 1997
Resolved
IDENTIFY AND PLACE IN EXPLOSION PROOF JUNCTION BOX SPLICE/JACKET DAMAGE TO INTERCOM UNIT WIRING ON DRILL FLOOR.
Condition: Unknown
Due 10 November 1997
Resolved 10 November 1997
Construction/Loadline
Issued 10 November 1997
Resolved
PROVE PROPER OPERATION OF INDICATOR LIGHT ON BALLAST SUCTION VALVE B-906 INSTARBOARD PUMP ROOM.
Condition: Unknown
Due 10 November 1997
Resolved 10 November 1997
Accommodation/Occupational Safety
Issued 10 November 1997
Resolved
WHEN DRILLING OPS PERMIT OR AT NEXT RIG MOVE, TEST VENTILATION SHUTDOWN, PROVIDE USCG W/REPORT.
Condition: Unknown
Due 10 November 1997
Resolved 10 November 1997
Engineering
Issued 10 November 1997
Resolved
PROVIDE SIGHT GLASS GUARDS FOR SSDG #1,2,3, AND OVERHEAD LUBE OIL TANK IN ENGINE ROOM.
Condition: Unknown
Due 15 December 1997
Resolved 2 December 1997
Electrical
Issued 10 November 1997
Resolved
WHEN DRILLING OPS PERMIT OR AT NEXT RIG MOVE TEST PURGED SYSTEM ON DRILL FLOOR EQUIPMENT, PROVIDE REPORT TO USCG
Condition: Unknown
Due 10 November 1997
Resolved 10 November 1997
Unknown
Issued 10 November 1997
Resolved
WHEN DRILLING OPS PERMIT OR AT NEXT RIG MOVE TEST AIR RECIEVER SAFETIES AND#7 AND #8 BARITE TANK SAFETIES, PROVIDE 3RD PARTY REPORT TO USCG.
Condition: Unknown
Due 10 November 1997
Resolved 10 November 1997
Electrical
Issued 10 November 1997
Resolved
WHEN DRILLING OPS PERMIT OR AT NEXT RIG MOVE, TEST EMERGENCY SHUTDOWNS OF MAIN DIESEL ENGINES AND REVERSE POWER RELAY, PROVIDE REPORT OF SAME TO USCG.
Condition: Unknown
Due 10 November 1997
Resolved 10 November 1997
Fire Fighting
Issued 10 November 1997
Resolved
ADJUST PACKING ON FIREPUMP IN STARBOARD PUMP ROOM TO REDUCE EXCESS LEAKAGE.
Condition: Unknown
Due 10 November 1997
Resolved 10 November 1997
Fire Fighting
Issued 10 November 1997
Resolved
PROVIDE SMALLER (4FT) APPLICATOR FOR ENGINE ROOM FIRE STATION.
Condition: Unknown
Due 10 November 1997
Resolved 10 November 1997
Electrical
Issued 10 November 1997
Resolved
PROVIDE (OR MARK EXISITING) E-LIGHTS OVER MDE ALARM PANEL #1 AND #3 AND E- GEN PANEL.
Condition: Unknown
Due 10 November 1997
Resolved 10 November 1997
Fire Fighting
Issued 10 November 1997
Resolved
PROVIDE ADDITIONAL GENERAL ALARM LIGHT IN ENGINE ROOM TO ENSURE 100% DETECTABILITY.
Condition: Unknown
Due 10 November 1997
Resolved 10 November 1997
Fire Fighting
Issued 12 November 1996
Resolved
CROP AND RENEW STAND PIPE FIRE STATION NO.34._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 November 1996
Resolved 12 November 1996
Lifesaving
Issued 12 November 1996
Resolved
PROVIDE INSPECTION CERTIFICATES FOR LIFERAFTS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 November 1996
Resolved 12 November 1996
Electrical
Issued 12 November 1996
Resolved
REPAIR DRILLERS CONSOLE PURGE ALARMS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 November 1996
Resolved 12 November 1996
Documentation
Issued 12 November 1996
Resolved
RESUBMIT FOR APPROVAL FIRE CONTROL PLAN TO ABS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 November 1996
Resolved 12 November 1996
Navigation
Issued 12 November 1996
Resolved
PROVIDE HAND HELD PARACHUTE FLARES FOR THE VESSEL._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 December 1996
Resolved 17 December 1996
Electrical
Issued 12 November 1996
Resolved
REMOVE DEADEND WIRES ON HELO PAD BY HELO PERIMETER LIGHT FIXTURES._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 December 1996
Resolved 17 December 1996
Electrical
Issued 12 November 1996
Resolved
REPLACE BURNT-OUT LIGHTS ON HELO PERIMETER PAD.
Condition: Unknown
Due 17 December 1996
Resolved 17 December 1996
Documentation
Issued 12 November 1996
Resolved
PROVIDE ABS REVIEW/APPROVAL OF CONSTRUCTION PORTFOLIO.
Condition: Unknown
Due 10 December 1996
Resolved 27 December 1996
Lifesaving
Issued 12 November 1996
Resolved
CONDUCT TEMPORARY REPAIR OF CRACKED RUDDER TO NO.1 LIFEBOAT CAPSULE AS PER MANUFACTURE RECOMMENDATIONS AND PROVIDE PHOTOS OF SAME. REPLACE RUDDER ASSEMBLY AS SOON AS MANUFACTURER CAN CONSTRUCT AND SHIP UNIT TO THE VESSEL.
Condition: Unknown
Due 12 November 1996
Resolved 12 November 1996
Fire Fighting
Issued 12 November 1996
Resolved
REPAIR/CORRECT FIRE STATION NO.23 WITH NO WATER PRESSURE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 November 1996
Resolved 12 November 1996
Documentation
Issued 12 November 1996
Resolved
PROVIDE COPY OF EXEMPTIONS ISSUED BY FLAG STATE UNDER I.M.O. MODU CODE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 November 1996
Resolved 12 November 1996
Documentation
Issued 12 November 1996
Resolved
PROVIDE ORIGINAL C.G. TEMPORARY CERTIFICATE OF INSPECTION._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 November 1996
Resolved 12 November 1996
Documentation
Issued 12 November 1996
Resolved
COMMENCE WASTE MANAGEMENT LOG I.A.W. 33 CFR 151.55_x001C_
Condition: Unknown
Due 17 December 1996
Resolved 17 December 1996
Lifesaving
Issued 12 November 1996
Resolved
PROVIDE INSPECTION CERTIFICATES FOR LIFERAFTS RELEASING HOOKS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 November 1996
Resolved 12 November 1996
Lifesaving
Issued 12 November 1996
Resolved
PROVIDE BOARDING LADDER FOR NO.2 LIFEBOAT CAPSULE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 November 1996
Resolved 12 November 1996
Lifesaving
Issued 12 November 1996
Resolved
REPAIR NO.2 LIFEBOAT CAPSULE SPRINKLER SYSTEM._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 December 1996
Resolved 17 December 1996
Lifesaving
Issued 12 November 1996
Resolved
REPAIR NO.1 LIFEBOAT CAPSULE SPRINKLER SYSTEM._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 December 1996
Resolved 17 December 1996
Lifesaving
Issued 12 November 1996
Resolved
PROVIDE INSPECTION CERTIFICATES FOR LIFERAFTS RELEASING HOOKS.
Condition: Unknown
Due 12 November 1996
Resolved 12 November 1996
Documentation
Issued 12 November 1996
Resolved
PROVIDE ABS REVIEW/APPROVAL OF CONSTRUCTION PORTFOLIO.
Condition: Unknown
Due 12 November 1996
Resolved 12 November 1996
Lifesaving
Issued 12 November 1996
Resolved
REPAIR NO.1 LIFEBOAT CAPSULE SPRINKLER SYSTEM.
Condition: Unknown
Due 10 December 1996
Resolved 12 December 1996
Lifesaving
Issued 12 November 1996
Resolved
PROVIDE INSPECTION CERTIFICATES FOR LIFERAFTS.
Condition: Unknown
Due 12 November 1996
Resolved 12 November 1996
Documentation
Issued 12 November 1996
Resolved
COMMENCE WASTE MANAGEMENT LOG I.A.W 33 CFR 151.55.
Condition: Unknown
Due 10 December 1996
Resolved 12 December 1996
Documentation
Issued 12 November 1996
Resolved
RESUBMIT FOR APPROVAL FIRE CONTROL PLAN TO ABS.
Condition: Unknown
Due 12 November 1996
Resolved 12 November 1996
Documentation
Issued 12 November 1996
Resolved
PROVIDE COPY OF EXEMPTIONS ISSUED BY FLAG STATE UNDER I.M.O MODU CODE.
Condition: Unknown
Due 12 November 1996
Resolved 12 November 1996
Fire Fighting
Issued 12 November 1996
Resolved
CROP AND RENEW STAND PIPE FIRE STATION NO.34
Condition: Unknown
Due 12 November 1996
Resolved 12 November 1996
Lifesaving
Issued 12 November 1996
Resolved
CONDUCT TEMPORARY REPAIR OF CRACKED RUDDER TO NO.1 LIFEBOAT CAPSULE AS PER MANUFACTURE RECOMMENDATIONS AND PROVIDE PHOTOS OF SAME. REPLACE RUDDER ASSEMBLY AS SOON AS MANUFACTURER CAN CONSTRUCT AND SHIP UNIT TO THE VESSEL.
Condition: Unknown
Due 12 November 1996
Resolved 12 November 1996
Fire Fighting
Issued 12 November 1996
Resolved
REPAIR/CORRECT FIRE STATION NO.23 WITH NO WATER PRESSURE.
Condition: Unknown
Due 12 November 1996
Resolved 12 November 1996
Documentation
Issued 12 November 1996
Resolved
PROVIDE ORIGINAL C.G. TEMPORARY CERTIFICATE OF INSPECTION.
Condition: Unknown
Due 12 November 1996
Resolved 12 November 1996
Navigation
Issued 12 November 1996
Resolved
PROVIDE HAND HELD PARACHUTE FLARES FOR THE VESSEL.
Condition: Unknown
Due 10 December 1996
Resolved 12 December 1996
Electrical
Issued 12 November 1996
Resolved
REPLACE BURNT-OUT LIGHTS ON HELO PERIMETER PAD.
Condition: Unknown
Due 10 December 1996
Resolved 12 December 1996
Electrical
Issued 12 November 1996
Resolved
REPAIR DRILLERS CONSOLE PURGE ALARM.
Condition: Unknown
Due 12 November 1996
Resolved 12 November 1996
Lifesaving
Issued 12 November 1996
Resolved
PROVIDE BOARDING LADDER FOR NO.2 LIFEBOAT CAPSULE.
Condition: Unknown
Due 12 November 1996
Resolved 12 November 1996
Electrical
Issued 12 November 1996
Resolved
REMOVE DEADEND WIRES ON HELO PAD BY HELO PERIMETER LIGHT FIXTURES.
Condition: Unknown
Due 10 December 1996
Resolved 12 December 1996
Lifesaving
Issued 12 November 1996
Resolved
REPAIR NO.2 LIFEBOAT CAPSULE SPRINKLER SYSTEM.
Condition: Unknown
Due 10 December 1996
Resolved 12 December 1996
Documentation
Issued 8 February 1996
Resolved
PROVIDE ON BOARD VESSEL AN APPROVED SHIPBOARD OIL POLLUTION EMERGENCY PLAN.
Condition: Unknown
Due 8 February 1996
Resolved 17 November 1996
Construction/Loadline
Issued 8 February 1996
Resolved
REPAIR/RENEW DAMAGED/WASTED SECTIONS OF BALLAST TANK VENTS LOCATED IN BALLAST TANKS A-911/B-903/B-904.
Condition: Unknown
Due 8 February 1996
Resolved 17 November 1996
Documentation
Issued 8 February 1996
Resolved
PROVIDE ON BOARD VESSEL CERTIFICATE OF FINANICAL RESPONSIBILITY.
Condition: Unknown
Due 8 February 1996
Resolved 17 November 1996
Electrical
Issued 8 February 1996
Resolved
REPAIR AND PROVE OPERATION OF ELECTRICAL SYSTEM PURGE ALARMS LOCATED ON THEDRILLERS CONSOLE.
Condition: Unknown
Due 8 February 1996
Resolved 17 November 1996
Documentation
Issued 8 February 1996
Resolved
PROVIDE ACCURATE FIRE CONTROL PLAN IAW 46 CFR 91.55-5(d)
Condition: Unknown
Due 8 February 1996
Resolved 17 November 1996
Navigation
Issued 8 February 1996
Resolved
PROVIDE AND INSTALL AN AUTOMATIC FOG SIGNAL DEVICE IAW 33 CFR SUBPART 67.
Condition: Unknown
Due 8 February 1996
Resolved 17 November 1996
Electrical
Issued 8 February 1996
Resolved
LABEL NEW ELECTRICAL DISTRIBUTION PANEL WITH DIRECTORY OF CIRCUITS LOCATED IN THE PORT TUNNEL.
Condition: Unknown
Due 8 February 1996
Resolved 17 November 1996
Electrical
Issued 8 February 1996
Resolved
REPAIR AND PROVE OPERATION OF PORT AND STBD ELEVATOR SAFETY STOPS
Condition: Unknown
Due 8 February 1996
Resolved 17 November 1996
Documentation
Issued 8 February 1996
Resolved
PROVIDE ACCURATE LIFESAVING EQUIPMENT PLAN IAW 46 CFR 96.55-5(g).
Condition: Unknown
Due 8 February 1996
Resolved 17 November 1996
Fire Fighting
Issued 8 February 1996
Resolved
REPAIR AND PROVE OPERATION OF ALL GENERAL ALARMS THROUGHOUT THE VESSEL.
Condition: Unknown
Due 8 February 1996
Resolved 17 November 1996
Fire Fighting
Issued 8 February 1996
Resolved
PROVIDE ACCURATE OPERATING INSTRUCTION PLACARD FOR FIXED CO2 SYSTEM AT BOTHREMOTE OPERATING STATIONS AND MAIN MANIFOLD OPERATING POSITION.
Condition: Unknown
Due 8 February 1996
Resolved 17 November 1996
Engineering
Issued 8 February 1996
Resolved
REPAIR/RENEW INSULATION AT EXPANSION JOINTS OF PRIME MOVER EXHAUST PIPING ABOVE DIESEL FUEL OIL SETTLING TANK IN DAY TANK COMPARTMENT
Condition: Unknown
Due 8 February 1996
Resolved 17 November 1996
Unknown
Issued 26 January 1989
Resolved
VESSEL TO BE STACKED OR DRYDOCKED UPON COMPLETION OF WELL 12337.
Condition: Unknown
Due 26 January 1989
Resolved 26 January 1989
Construction/Loadline
Issued 7 December 1988
Resolved
MAKE VALVES B909 AND B913 MANUALLY OPERABLE.
Condition: Unknown
Due 7 December 1988
Resolved 7 December 1988
Construction/Loadline
Issued 7 December 1988
Resolved
MAKE VALVE B905 CAPABLE OF REMOTE POWER OPERATION.
Condition: Unknown
Due 7 December 1988
Resolved 7 December 1988
Construction/Loadline
Issued 7 December 1988
Resolved
FREE UP AND MAKE OPERATIONAL THE TWO PORT HYDROPHONE THROUGH HULL VALVES.
Condition: Unknown
Due 7 December 1988
Resolved 7 December 1988
Construction/Loadline
Issued 7 December 1988
Resolved
VESSEL TO BE STACKED OR DRYDOCKED UPON COMPLETION OF WELL 12337 AND NOT LATER THAN 31 JANUARY 1989.
Condition: Unknown
Due 7 December 1988
Resolved 7 December 1988
Unknown
Issued 7 December 1988
Resolved
MAKE PORT PONTOON PUMPROOM AUTOMATIC BILGE PUMP OPERATIONALY CONTROLLED BY BILGE LEVEL INDICATOR.
Condition: Unknown
Due 7 December 1988
Resolved 7 December 1988
Electrical
Issued 30 August 1988
Resolved
REPLACE HOT SPOT TRANSFER MGR SENSAR IN THYRISTOR ROOM GUAGE INDENTED GLASSBROKEN ETC.
Condition: Unknown
Due 30 August 1988
Resolved 30 August 1988
Construction/Loadline
Issued 30 August 1988
Resolved
REPLACE A/C SYSTEM OPERATING LIGHTS ON CONTROL PANEL.
Condition: Unknown
Due 30 August 1988
Resolved 30 August 1988
Fire Fighting
Issued 30 August 1988
Resolved
SERVICE VALVE ON FIRE STA 24 VALVE LEAKING THROUGH STEM.
Condition: Unknown
Due 30 August 1988
Resolved 30 August 1988
Electrical
Issued 30 August 1988
Resolved
EX LOG - REMOVE THE 1/4" STAINLESS WIRE BANDS AND INSTALL 5/8" BANDS SEE IEEE-45
Condition: Unknown
Due 30 August 1988
Resolved 30 August 1988
Electrical
Issued 30 August 1988
Resolved
EX LOG - CORRECT BULKHEAD PENETRATIONS BETWWEN MUD PIT AND MUD PUMP ROOM. MUST BE GAS TIGHT FITTING - SILICON WILL NOT DO.
Condition: Unknown
Due 30 August 1988
Resolved 30 August 1988
Fire Fighting
Issued 30 August 1988
Resolved
RECHARGE DRY CHEM. BOTTLE IN ENGINE ROOM. PORTABLE LOCATE BY #3M.
Condition: Unknown
Due 30 August 1988
Resolved 30 August 1988
Construction/Loadline
Issued 30 August 1988
Resolved
TWO WT DOORS LOCATED IN STARBOARD STOWAGE TUNNEL, THREE DOGS MISSING AND TWO DOGS LOOSE.
Condition: Unknown
Due 30 August 1988
Resolved 30 August 1988
Documentation
Issued 30 August 1988
Resolved
CORRECT HOMEPORT ON COD TO NEW ORLEANS LA, MORGAN CITY LA WILL REMAIN THE HAILING REPORT
Condition: Unknown
Due 30 August 1988
Resolved 30 August 1988
Fire Fighting
Issued 30 August 1988
Resolved
PROVIDE FOAM ANAYLISIS REPORT.
Condition: Unknown
Due 30 August 1988
Resolved 30 August 1988
Unknown
Issued 30 August 1988
Resolved
FOG HORN SOUNDS "DELTA" NEEDS TO SOUND A SECOND BLAST EACH 18 SECONDS.
Condition: Unknown
Due 30 August 1988
Resolved 30 August 1988
Construction/Loadline
Issued 30 August 1988
Resolved
REMOTE OPERATED VALVES IN PORT PUMP ROOM B913D. B905D AND STBD PUMP ROOM A-904 SUCTION INOPERATIVE.
Condition: Unknown
Due 30 August 1988
Resolved 30 August 1988
Lifesaving
Issued 30 August 1988
Resolved
CLEAN WITH WIRE BRUSH AND VISUALLY INSPECTED DECK WELDS ON DAVITS. REWELD IF NECESSARY. NOTE: NO CRACKS NOTED.
Condition: Unknown
Due 30 August 1988
Resolved 30 August 1988
Lifesaving
Issued 30 August 1988
Resolved
INSPECT AND REPAIR AS CECESSARY THE TRANSMISSION ON THE #1 BOAT. IT MAKES A BAD SOUND IN FORWARD GEAR. REPLACE THE BEND PROPELLER.
Condition: Unknown
Due 30 August 1988
Resolved 30 August 1988
Construction/Loadline
Issued 12 August 1987
Resolved
PROVE INTEGRITY OF BALLAST VALVES NUMBERS 912 SUCTION AND 906 SUCTION IN LOWER STARBOARD BALLAST PUMP ROOMS, DUE TO APPARENT EXCESSIVE CORROSION.
Condition: Unknown
Due 12 August 1987
Resolved 12 August 1987
Deck/Cargo
Issued 12 August 1987
Resolved
PROVIDE 13 ADDITIONAL RELIEF VALVES DESIGNED TO RELIEVE AT NOT MORE THAN 2400 PSI. VALVES TO BE TESTED TO THE SATISFACTION ON THE ATTENDING COAST GUARD INSPECTOR.
Condition: Unknown
Due 12 August 1987
Resolved 12 August 1987
Construction/Loadline
Issued 12 August 1987
Resolved
CONDUCT TEST OF THE BALLAST CONTROL SYSTEM FOR THE PORT PUMP ROOM.
Condition: Unknown
Due 12 August 1987
Resolved 12 August 1987
Electrical
Issued 12 August 1987
Resolved
REPAIR OR RENEW WASTED ELECTRICAL WIRE RUN SUPPORT TRAYS LOCATED UNDER DRILL FLOOR. 46 CFR 111
Condition: Unknown
Due 12 August 1987
Resolved 12 August 1987
Electrical
Issued 12 August 1987
Resolved
REPLACE BROKEN EYS FITTING LOCATED IN #1 MUD PIT ROOM.
Condition: Unknown
Due 12 August 1987
Resolved 12 August 1987
Accommodation/Occupational Safety
Issued 12 August 1987
Resolved
VESSEL MANNING IS HEREBY REDUCED TO NO MORE THAN 64 PERSONS, PENDING REPAIRAND SATISFACTORY WEIGHT TEST OF STARBOARD LIFEBOAT.
Condition: Unknown
Due 12 August 1987
Resolved 12 August 1987
Documentation
Issued 12 August 1987
Resolved
PROVIDE TO [name withheld] COPY OF APPROVAL LETTER FOR OPERATIONS MANUAL DTD 1 JUN 1978. PROVIDE ORIGINAL TO VESSEL.
Condition: Unknown
Due 12 August 1987
Resolved 12 August 1987
Lifesaving
Issued 12 August 1987
Resolved
DEMONSTRATE SATISFACTORY WEIGHT TEST FOR STARBOARD BOAT.
Condition: Unknown
Due 12 August 1987
Resolved 12 August 1987
Fire Fighting
Issued 12 August 1987
Resolved
PROVIDE FACE SHIELD FOR EMERGENCY GEAR LOCKER NUMBER 2 AND REPAIR CUFF ON LEFT SLEEVE OF FIREMAN'S JACKET IN SAME LOCKER.
Condition: Unknown
Due 12 August 1987
Resolved 12 August 1987
Lifesaving
Issued 12 August 1987
Resolved
REPLENISH COMPRESSED AIR BOTTLE IN STARBOARD LIFEBOAT.
Condition: Unknown
Due 12 August 1987
Resolved 12 August 1987
Lifesaving
Issued 12 August 1987
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 12 August 1987
Resolved 12 August 1987
Fire Fighting
Issued 12 August 1987
Resolved
PROVIDE THUMBSCREW CAPS TO REPLACE MISSING UNITS FOR CO2 PNEUMATIC SWITCHESIN CO2 ROOM.
Condition: Unknown
Due 12 August 1987
Resolved 12 August 1987
Fire Fighting
Issued 12 August 1987
Resolved
SHOW SATISFACTORY HYDRO TEST FOR FIRE STATION #22 (TWENTY-TWO).
Condition: Unknown
Due 12 August 1987
Resolved 12 August 1987
Fire Fighting
Issued 12 August 1987
Resolved
REPLACE PIPE ON LOWER RIGHT SIDE OF FOAM TANK.
Condition: Unknown
Due 12 August 1987
Resolved 12 August 1987
Fire Fighting
Issued 12 August 1987
Resolved
PROVIDE CAP FOR DEAD-ENDED FLEX LOOP IN CO2 ROOM UNTIL MISSING BOTTLE IS RETURNED.
Condition: Unknown
Due 12 August 1987
Resolved 12 August 1987
Electrical
Issued 12 August 1987
Resolved
REPLACE HORIZONTAL CABLE TRAYS IN BOTH PORT ANS STARBOARD BALLAST PUMP ROOMS, LOWER, AND REATTACH CABLES TO SAME.
Condition: Unknown
Due 12 August 1987
Resolved 12 August 1987
Fire Fighting
Issued 12 August 1987
Resolved
DEMONSTRATE SATISFACTORY HYDROSTATIC TEST ON FOAM TANK.
Condition: Unknown
Due 12 August 1987
Resolved 12 August 1987
Fire Fighting
Issued 12 August 1987
Resolved
REPLACE DEFECTIVE FAN GUARD ON MOTOR IN FOAM ROOM.
Condition: Unknown
Due 12 August 1987
Resolved 12 August 1987
Navigation
Issued 12 August 1987
Resolved
SHOW PROPER OPERATION OF NAVIGATION LIGHTS ON VESSEL, PARTICULARLY THE STERN LIGHTS, ANCHOR LIGHTS AND NOT UNDER COMMAND LIGHTS.
Condition: Unknown
Due 12 August 1987
Resolved 12 August 1987
Construction/Loadline
Issued 30 November 1986
Resolved
MAKE PERMANENT REPAIRS IN WAY OF THE BELL MOUTHS IN THE FOLLOWING PONTOON BALLAST TANKS; B-902-B, A-910-B,B-901-B, A-909-B AND A-904-B.
Condition: Unknown
Due 30 November 1986
Resolved 30 November 1986
Fire Fighting
Issued 7 September 1986
Resolved
REPAIR THE WASTED PIPING AT THE REDUCED FITTING, FIRE STATION 7, SHELL SHAKER.
Condition: Unknown
Due 7 September 1986
Resolved 7 September 1986
Navigation
Issued 7 September 1986
Resolved
REPAIR RANGE LIGHT AND FORWARD ANCHOR LIGHT.
Condition: Unknown
Due 7 September 1986
Resolved 7 September 1986
Electrical
Issued 7 September 1986
Resolved
MAKE OPERATIONAL THE OVERSPEED TRIP FOR ENGINE/GENERATOR SET NO.9.
Condition: Unknown
Due 7 September 1986
Resolved 7 September 1986
Electrical
Issued 7 September 1986
Resolved
PROVE THAT THE OVERSPEED TRIP FOR THE EMERGENCY GENERATOR IS SET NOT IN EXCESS OF 115% OF THE RATED ENGINE RPM.
Condition: Unknown
Due 7 September 1986
Resolved 7 September 1986
Electrical
Issued 7 September 1986
Resolved
PROVIDE A DRINKING FOUNTAIN ON THE DRILL FLOOR THAT IS RATED FOR A HAZARDOUS LOCATION OR PROVIDE DOCUMENTATION THAT THE ONE INSTALLED IS CORRECTLY RATED.
Condition: Unknown
Due 7 September 1986
Resolved 7 September 1986
Accommodation/Occupational Safety
Issued 7 September 1986
Resolved
PROVIDE THE KOOMEY UNIT WITH TWO, IN LINE, SWING CHECK VALVE IN THE 3/4 PORTABLE WATER SUPPLY LINE JUST BEFORE THE 1 1/2 LINE.
Condition: Unknown
Due 7 September 1986
Resolved 7 September 1986
Construction/Loadline
Issued 7 September 1986
Resolved
REMOVE THE OBSTRUCTIONS NOT ALLOWING THE WATER TIGHT HATCH TO CLOSE, DAY TANK ROOM BOW MAIN DECK.
Condition: Unknown
Due 7 September 1986
Resolved 7 September 1986
Electrical
Issued 7 September 1986
Resolved
PROVIDE ELECTRICAL PLUGS FOR THE LOGGING UNIT LOCATED ABOVE THE SHELL SHAKER ROM WITH A RATING FOR A HAZARDOUS LOCATION.
Condition: Unknown
Due 7 September 1986
Resolved 7 September 1986
Construction/Loadline
Issued 7 September 1986
Resolved
REMOVE THE OBSTRUCTIONS FROM THE GAS TIGHT DOOR TO THE MUD PIT(S) ROOM. DOOR WILL NOT CLOSE.
Condition: Unknown
Due 7 September 1986
Resolved 7 September 1986
Electrical
Issued 7 September 1986
Resolved
PROVIDE SATISFACTORY OPERATION OF THE DRILLERS CONSOLE AIR PURGE SYSTEM.
Condition: Unknown
Due 7 September 1986
Resolved 7 September 1986
Engineering
Issued 7 September 1986
Resolved
MAKE ACCESSABLE THE REMOTE FUEL SHUT-OFF FOR THE EMD'S PROPERLY MARK THE LOCATION AD PROVIDE A WRENCH IN THE EMMEDIATE AREA TO OPERATE THE VALVE ANDREMOVE THE CAP.
Condition: Unknown
Due 7 September 1986
Resolved 7 September 1986
Electrical
Issued 7 September 1986
Resolved
PROVIDE REMOTE FUEL SHUT-OFF FOR THE SKID MOUNTED FUEL OIL TANK FOR THE EMERGENCY GENERATOR.
Condition: Unknown
Due 7 September 1986
Resolved 7 September 1986
Fire Fighting
Issued 7 September 1986
Resolved
CONDUCT HYDROSTATIC TEST FIXED FIRE EXTINGUISHING BOTTLES, 75 LB, FOR THE EMERGENCY GENERATOR ROOM. HYDROSTATIC TEST OF THE FLEXIBLE LOOPS IS ALSO REQUIRED.
Condition: Unknown
Due 7 September 1986
Resolved 7 September 1986
Electrical
Issued 7 September 1986
Resolved
PROPERLY MOUNT THE CONTROL FOR THE AIR RECEIVER LOCATED IN THE RIG AIR COMPRESSOR ROOM.
Condition: Unknown
Due 7 September 1986
Resolved 7 September 1986
Fire Fighting
Issued 7 September 1986
Resolved
CONDUCT THE REQUIRED HYDROSTATIC TEST OF THE FIXED CO2 FIRE EXTINGUISHING BOTTLES AND THE FLEXIBLE LOPS, MACHINERY SPACES.
Condition: Unknown
Due 7 September 1986
Resolved 7 September 1986
Accommodation/Occupational Safety
Issued 7 September 1986
Resolved
PROVIDE THE PORTABLE WATER AND THE SANITARY ATER PRESSURE TANKS WITH RELIEFVALVES SET AT LESS THAN 100 PSI OR OPEN FOR INTERNAL INSPECTION AND BENCH TEST OF THE RELIEF VALVES.
Condition: Unknown
Due 7 September 1986
Resolved 7 September 1986
Fire Fighting
Issued 7 September 1986
Resolved
RECHARGE THE AIR BOTTLES OF THE SELF CONTAINING BREATHING APPARATUS IN BOTHFIREMANS' OUTFITS.
Condition: Unknown
Due 7 September 1986
Resolved 7 September 1986
Accommodation/Occupational Safety
Issued 6 June 1986
Resolved
PROVIDE NAME PLATE DATA FOR THE AIR RECEIVER ON THE LOW PRESSURE-AIR COMPRESSOR.
Condition: Unknown
Due 6 June 1986
Resolved 6 June 1986
Accommodation/Occupational Safety
Issued 31 January 1986
Resolved
MAKE OPERATIONAL THE OVERBOARD DISCHARGE VALVE B9105 HAND AND REMOTE OPERATION, PORT PUMP ROOM.
Condition: Unknown
Due 31 January 1986
Resolved 31 January 1986
Documentation
Issued 31 January 1986
Resolved
REPAINT THE VESSELS LOAD LINE MARKS, IN ACCORDANCE WITH THE LOAD LINE CERTIFICATE. TO BE COMPLETED AT NEXT RIG MOVE.
Condition: Unknown
Due 31 January 1986
Resolved 31 January 1986
Construction/Loadline
Issued 31 January 1986
Resolved
REPAIR AND MAKE OPERATIONAL THE ESCAPE SCUTTLE, QUICK ACTING HATCH, FROM THE PORT PUMP ROOM
Condition: Unknown
Due 31 January 1986
Resolved 31 January 1986
Construction/Loadline
Issued 20 August 1985
Resolved
HYDRO TEST OR INTERNALLY INSPECT THE TWENTY-SIX (26) PRESSURE VESSELS ON BOARD AND TEST THE RELIEF VALVES FOR THESE PRESSURE VESSELS.
Condition: Unknown
Due 20 August 1985
Resolved 20 August 1985
Unknown
Issued 20 August 1985
Resolved
APPLY SUITABLE NON-SKID SURFACE TO THE HELOPORT.
Condition: Unknown
Due 20 August 1985
Resolved 20 August 1985
Unknown
Issued 21 August 1984
Resolved
PROVIDE FIRE HOSE STATION ON DRILL FLOOR TO BE CONNECTED TO DRILL WATER SYSTEM AND UPDATE FIRE CONTROL PLAN ACCORDINGLY THIS ITEM TO BE COMPLETED BY 21SEP84 AND TO BE TO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR IAW NVI4-78-3(D)(7)(B)UPON COMPLETION OF THIS ITEM NOTIFY [name withheld]
Condition: Unknown
Due 21 August 1984
Resolved 21 August 1984
Fire Fighting
Issued 16 August 1983
Resolved
SUBMIT FIRE CONTROL PLAN FOR REVIEW AND APPROVAL BY USCG.
Condition: Unknown
Due 16 August 1983
Resolved 16 August 1983
Electrical
Issued 16 August 1983
Resolved
SUBMIT CLASSIFIED AREA PLANS FOR REVIEW AND APPROVAL BY USCG.
Condition: Unknown
Due 16 August 1983
Resolved 16 August 1983
Unknown
Issued 16 August 1983
Resolved
COMPLETE MARKING OF VESSEL EQUIPMENT AND INSTRUCTIONS IN ACCORDANCE WITH 46 CFR PART SIX (6)
Condition: Unknown
Due 16 August 1983
Resolved 16 August 1983
Deck/Cargo
Issued 16 August 1983
Resolved
REPLACE DAMAGED PRESSURE VESSEL AT DRILL STRING COMPENSATOR.
Condition: Unknown
Due 16 August 1983
Resolved 16 August 1983
Electrical
Issued 16 August 1983
Resolved
PROVIDE PURGE AND ALARM FOR DRAWWORKS CONNECTIONS.
Condition: Unknown
Due 16 August 1983
Resolved 16 August 1983
Electrical
Issued 16 August 1983
Resolved
PROVIDE PURGE AND ALARM FOR DRILLER'S CONSOLE.
Condition: Unknown
Due 16 August 1983
Resolved 16 August 1983
Engineering
Issued 16 August 1983
Resolved
REVISE EXISTING OIL TRANSFER PROCEDURES TO COMPLY WITH 33 CFR 155.750.
Condition: Unknown
Due 16 August 1983
Resolved 16 August 1983
Fire Fighting
Issued 16 August 1983
Resolved
REPLACE ALL NON-USCG/UL APPROVED PORTABLE AND SEMI-PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 16 August 1983
Resolved 16 August 1983
Unknown
Issued 16 August 1983
Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE MODU PENROD 75, VIN=DN574670.
Condition: Unknown
Due 16 August 1983
Resolved 16 August 1983
Lifesaving
Issued 16 August 1983
Resolved
TOTAL PERSONS ON BOARD LIMITED TO TWENTY-FOUR (24) UNTIL 89 USCG APPROVED TYPE-I LIFE PRESERVERS ARE PROVIDED.
Condition: Unknown
Due 16 August 1983
Resolved 16 August 1983
Lifesaving
Issued 16 August 1983
Resolved
REPLACE THE TWO (2) RING BUOY SMOKE SIGNALS WITH USCG APPROVED EQUIPMENT.
Condition: Unknown
Due 16 August 1983
Resolved 16 August 1983
Electrical
Issued 16 August 1983
Resolved
REPAIR GENERAL ALARM BELLS IN MUD PUMP AREA.
Condition: Unknown
Due 16 August 1983
Resolved 16 August 1983
Fire Fighting
Issued 16 August 1983
Resolved
MAKE REPAIRS WITH APPROVED MATERIALS TO CEILING IN ACCOMMODATION AND MACHINERY SPACES WHERE DAMAGED.
Condition: Unknown
Due 16 August 1983
Resolved 16 August 1983
Deck/Cargo
Issued 16 August 1983
Resolved
PROVIDE COVERS OR GUIDES FOR CABLES ON AIR TUGGERS.
Condition: Unknown
Due 16 August 1983
Resolved 16 August 1983
Fire Fighting
Issued 16 August 1983
Resolved
REPLACE ALL NON-USCG APPROVED ALL-PURPOSE HOSE NOZZLES.
Condition: Unknown
Due 16 August 1983
Resolved 16 August 1983
Lifesaving
Issued 16 August 1983
Resolved
REPLACE ALL NON-USCG APPROVED FOOD WATER AND FLARES IN THE LIFEBOATS.
Condition: Unknown
Due 16 August 1983
Resolved 16 August 1983
Electrical
Issued 16 August 1983
Resolved
COMPLETE REPLACEMENT OF SILICONE IN EYS SEALS WITH CHICO.
Condition: Unknown
Due 16 August 1983
Resolved 16 August 1983
Fire Fighting
Issued 16 August 1983
Resolved
REPLACE ALL NON-MARINE THREAD FIRE HOSES AND HOSE STATION FITTINGS WITH NATIONAL STANDARD FIRE HOSE COUPLING THREAD.
Condition: Unknown
Due 16 August 1983
Resolved 16 August 1983
Lifesaving
Issued 16 August 1983
Resolved
HYDRO-TEST THE AIR BOTTLES IN EACH LIFEBOAT AND RECHARGE.
Condition: Unknown
Due 16 August 1983
Resolved 16 August 1983
Lifesaving
Issued 16 August 1983
Resolved
COMPLETE SERVICING OF FOUR (4) LIFE RAFTS AND REINSTALL.
Condition: Unknown
Due 16 August 1983
Resolved 16 August 1983
Lifesaving
Issued 16 August 1983
Resolved
COMPLETE BIENNIAL WEIGHT TEST OF DAVITS AND LIFEBOATS PRIOR TO INCREASING TOTAL PERSONS ALLOWED ON BOARD. TEST TO BE WITNESSED BY USCG INSPECTOR.
Condition: Unknown
Due 16 August 1983
Resolved 16 August 1983