Records from 2016 to 2026. Most recent: inspection, 22 April 2026.
Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 22
22 April 2026
Administrative Inspection · Annual Inspection · Vessel Attendance
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8308321
14 April 2026
Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8306872
23 July 2025
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8193111
26 June 2025
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8168131
11 March 2025
Special Consideration · Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8091818
3 February 2025
Annual Inspection · Administrative Inspection · In-Service Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8073935
26 April 2024
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7902122
26 February 2024
Annual Inspection · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7870214
29 November 2022
Drydock Exam · COI Inspection · Cargo Tank Internal · Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7601173
23 September 2022
Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7554185
1 June 2021
Internal Structural Exam · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7212589
11 May 2020
Annual Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6937440
11 June 2019
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6711125
1 May 2019
COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6655663
30 November 2018
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6590098
11 May 2018
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6417178
1 May 2018
In-Service Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6402870
30 March 2018
Damage Survey · Hull Examination · In-Service Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6408520
8 March 2018
In-Service Inspection · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6371887
30 May 2017
DAPI Audit · Administrative Inspection · Internal Structural Exam · Deficiency Check · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6159985
1 June 2016
Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5895256
24 May 2016
Hull Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5885163
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 February 2025
Resolved
The height of top rails required by paragraph (a) of this section must be as follows; at least 910 millimeters (36 inches) high. MI observed railing height throughout vessel to be 24 to 27 inches. All passengers and crew are required to wear life jackets or work vests while on deck with vessel underway.
Condition: Design Flaw
Action required: 705 - Other - as specified
Resolved 26 June 2025
Resolution: Completed special consideration for vessel railing height. See MISLE Activity # 8091818
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 March 2023
Resolved
Inspection of piping, controls, and valves, and the inspection and testing of alarms and ventilation shutdowns, for each fixed gas fire extinguishing system and detection system to determine that the system is in operating condition. Ventilation closure for the engine room did not make a proper seal when secured, add gasket material or replace components to vent closures to create air-tight seal and operate as required.
46 CFR 176.810(a)(2)
Action required: 60 - Rectify deficiencies prior to movement
Due 13 March 2023
Resolved 20 March 2023
Resolution: Received, reviewed, and accepted documentation from vessel rep showing the install of new gasket material for L-bracket E/R ventilation closures, providing air tight seal.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Ship's occupational safety and health policies and programmes
Issued 13 March 2023
Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI. Vessel unable to provide any alcohol testing kits kept onboard.
46 CFR 4.06-15(a)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 March 2023
Resolved 27 March 2023
Resolution: Verification of the required alcohol testing kits kept onboard recieved, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 13 March 2023
Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space. Portable lights found inoperable when tested. Replace or repair lights to a serviceable condition.
46 CFR 183.430
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 March 2023
Resolved 27 March 2023
Resolution: Photo verification of 02 new portable lights recieved and accepted, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 13 March 2023
Resolved
The EPIRB test required by paragraph (a) shall be logged or otherwise documented, as applicable. Vessel unable to provide records or documentation of monthly EPIRB testing. Provide documentation attesting to the proper maintenance if the vsl's EPIRB.
46 CFR 185.728(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 March 2023
Resolved 27 March 2023
Resolution: Photo verification of the onboard EPIRB test log received and accepted, all sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 March 2023
Resolved
Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information: (1) Date of the drill and training; (2) General description of the drill scenario and training topics. Vessel unable to provide any documentation showing the completion of drills within previous year. Provide verification of log showing required drills have been conducted.
46 CFR 185.520(f)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 March 2023
Resolved 27 March 2023
Resolution: verification of Log book, including record of recent drills/required entries received and accepted, all sat.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 13 March 2023
Resolved
Fire Fighting drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information: (1) Date of the drill and training; and (2) General description of the drill scenario and training topics. Vessel unable to provide any documentation showing the completion of drills within previous year. Provide verification of log showing required drills have been conducted.
46 CFR 185.524(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 March 2023
Resolved 27 March 2023
Resolution: verification of Log book, including record of recent drills/required entries received and accepted, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 13 March 2023
Resolved
A vessel of not more than 7.9 meters (26 feet) in length, but not more than 19.8 meters (65 feet), must carry a minimum of one life buoy of not less than 610 millimeters (24 inches) in diameter. Ring life buoy found deteriorated. Replace ring life buoy or moisture service plug to satisfaction of attending MI.
46 CFR 180.70(a)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 March 2023
Resolved 27 March 2023
Resolution: Life ring replaced and to the satisfaction of the Marine Inspector, all sat.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 13 March 2023
Resolved
The lights and shapes specified in these Rules shall comply with the provisions of Annex I of these Rules (33 CFR part 84). Vessel unable to provide required dayshapes, while on board. Provide verification of dayshapes onboard, and to the satisfaction of the MI.
33 CFR 83.20(e)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 March 2023
Resolved 27 March 2023
Resolution: Received verification of dayshapes onboard, and to the satisfaction of the MI
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 13 March 2023
Resolved
A vessel of 12 meters or more in length shall be provided with a whistle, a vessel of 20 meters or more in length shall be provided with a bell in addition to a whistle. Vessel's whistle found inoperable. Repair or replace whistle to satisfaction of attending MI.
33 CFR 83.33(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 March 2023
Resolved 27 March 2023
Resolution: Verification of the bell onboard received and accepted, all sat.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 13 March 2023
Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level. Visual indicator found inoperable when tested for bilge alarm sensor in accommodation space void.
46 CFR 182.530
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 13 March 2023
Resolved 13 March 2023
Resolution: Corrected prior to the departure of the Attending Marine Inspector, all sat.
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 1 May 2018
Resolved
During Annual inspection, fixed firefighting system was activated without discharging agent. Identify cause and repair prior to conducting operations.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 4 May 2018
Resolved 2 May 2018
Resolution: Service technician identified & fixed the issue with the system and provided documentation.
Engineering › Diesel Engine (propulsion-reduction gear) › Emergency shutdown
Issued 1 May 2018
Resolved
During Annual Inspection, main propulsion engines shutdown while conducting drills. Identify cause and repair prior to conducting operations.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 4 May 2018
Resolved 2 May 2018
Resolution: Faulty connection identified and repaired.
Electrical › Electric Generation Source (service) › Generator
Issued 1 May 2018
Resolved
During Annual Inspection, generator shut down while underway for drills. Identify cause and repair prior to conducting operations.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 4 May 2018
Resolved 2 May 2018
Resolution: Identified cause and remedied by technician.
Documentation › Manuals/Policy Documentation › Maneuvering Information
Issued 1 May 2018
Resolved
During Annual Inpsection, found counterfeit U.S. Coast Pilot publication.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2018
Resolved 2 May 2018
Resolution: U.S. Coast Pilot downloaded from NOAA website
Engineering › Fuel Oil Service System › Filter
Issued 30 May 2017
Resolved
Vessels fuel water separators have four non-bonnet style drain cocks. Unapproved drain cocks are prohibited.
Action required: 705 - Other - as specified
Due 6 June 2017
Resolved 7 June 2017
Resolution: Replaced with approved drain cocks.
Engineering › Bilge Water Management System › Valve
Issued 30 May 2017
Resolved
Vessel has check valves installed at the hull penetrations for overboard discharge. Vessel is required to have positive shutoff valves.
Action required: 705 - Other - as specified
Due 14 June 2017
Resolved 7 June 2017
Resolution: Added positive shutoff valves at the overboard discharge and kept check valves inline between the bilge pump and the positive shutoff valves.
Engineering › Bilge Water Management System › Interface Detector
Issued 30 May 2017
Resolved
Vessels bilge high level alarm does not identify the location of the compartment with a high level present. A visual and audible alarm must be provided to indicate a high water level in unmanned spaces.
Action required: 705 - Other - as specified
Due 26 June 2017
Resolved 7 June 2017
Resolution: Added another display light which differentiates which space has a high level.
Construction/Loadline › Structures › Scuttle
Issued 30 May 2017
Resolved
Vessels emergency escape hatches are not labelled. All escape hatches must be marked on both sides in lettering at least two inches high: "EMERGENCY EXIT, KEEP CLEAR."
Action required: 705 - Other - as specified
Due 6 June 2017
Resolved 7 June 2017
Resolution: Properly marked escape hatches.