05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 6 March 2026
Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. FCC Radiotelephony safety cert expired 7/22/2025.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 April 2026
Resolved 1 April 2026
Resolution: FCC exam complete.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 11 August 2025
Resolved
The owner or managing operator shall submit drawings, sketches, or written specifications describing the details of any proposed alterations to the cognizant [name withheld] alterations must be approved by the OCMI before work is started.
Completed hull alterations to accommodate bow thruster installation were not approved by the local [name withheld] shall submit drawings, sketches, or written specifications prior to transit. No carriage of passengers is authorized until alterations have been approved by local OCMI.
Action required: 60 - Rectify deficiencies prior to movement
Due 11 August 2025
Resolved 19 September 2025
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 13 March 2023
Resolved
A device must be provided to automatically shut down engines that draw intake air from the protected space prior to release of the extinguishing agent into the space. Provide proof that the equipment works as previously approved and designed to the attending MI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 March 2023
Resolved 22 March 2023
Resolution: Fixed fire fighting system now shuts down all machinery upon activation.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 13 March 2023
Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets. Identification of the items may be in words, or the appropriate symbols in IMO Resolution A.760(18). Letters and numbers must be at least 2 inches high. Label container to the satisfaction of attending MI.
Action required: 705 - Other - as specified
Due 20 March 2023
Resolved 5 April 2023
Resolution: Life jacket stowage compartment properly labeled.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 13 March 2023
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. Properly separate child and adult size life jackets.
Action required: 705 - Other - as specified
Due 20 March 2023
Resolved 5 April 2023
Resolution: Child and adult size life jackets are properly separated.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 13 March 2023
Resolved
A hatch cover must: (1) Have securing devices; and (2) Be attached to the hatch frame or combing by hinges, captive chains, or other devices of substantial strength to prevent its loss. Properly secure all hatches.
Action required: 705 - Other - as specified
Due 20 March 2023
Resolved 22 March 2023
Resolution: Captive lines were spliced on all deck hatches.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 13 March 2023
Resolved
Each battery used in an item of lifesaving equipment,
must be replaced during the annual inspection if the
expiration date of the battery has passed. Provide
unexpired battery for ring buoy water light.
Action required: 705 - Other - as specified
Due 20 March 2023
Resolved 22 March 2023
Resolution: Waterlight battery renewed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 March 2023
Resolved
Portable fire extinguishers must be installed to the
satisfaction of the [name withheld] mount fire extinguisher bracket in the wheel house.
Action required: 705 - Other - as specified
Due 20 March 2023
Resolved 5 April 2023
Resolution: Properly mounted on the bridge.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 13 March 2023
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: (1) Charts of large enough scale to make safe navigation possible; (2) U.S. Coast Pilot or similar publication; (3) Coast Guard Light List; (4) Tide tables; and (5) Current tables, or a river current publication issued by the U.S. Army Corps of Engineers or a river authority. Provide proof of all documents to attending MI.
Action required: 705 - Other - as specified
Due 20 March 2023
Resolved 5 April 2023
Resolution: Pubs and chart is onboard located in the bridge.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 13 March 2023
Resolved
Glass and other glazing material used in windows accessible to passengers and crew must be of material that will not break into dangerous fragments if fractured. Replace cracked wheel house window with in-kind equipment.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 April 2023
Resolved 22 March 2023
Resolution: Center bridge window replaced with new glass.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 13 March 2023
Resolved
Watertight doors and watertight hatches must be marked on both sides in clearly legible letters at least 1 inch high: “WATERTIGHT DOOR - KEEP CLOSED” or “WATERTIGHT
HATCH - KEEP CLOSED”. Properly label hatches.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 April 2023
Resolved 5 April 2023
Resolution: Hatches on the main deck are now marked.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 13 March 2023
Resolved
Gauges to indicate engine revolutions per minute (RPM), jacket water discharge temperature, and lubricating oil pressure must be provided for all propulsion engines installed in the vessel. Provide proof to attending MI that STBD MDE RPM gauge is operational.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 April 2023
Resolved 11 May 2023
Resolution: The STBD MDE RPM gauge was installed and is now operational.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 10 February 2023
Resolved
A vessel must operate within the regulatory confines of their COI and Stability Letter. Vsl has added and removed weights at different LCG. Vsl must perform a new stability test prior to resuming operations. 46 CFR 178.310 (c)(4)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 March 2023
Resolution: Conducted satisfactory simplified stability test.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 June 2022
Resolved
The managing operator must have the vessel ready for inspection of its fire protection equipment including the following : Inspection of each portable fire extinguisher, to check for excessive corrosion. Forward main deck fire extinguisher bracket found corroded. Renew in kind.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 June 2022
Resolved 13 July 2022
Resolution: Fire extinguisher bracket installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 June 2022
Resolved
Electrical equipment on a vessel must be installed and maintained to: Minimize accidental personnel contact with energized parts. Bridge console is missing door. Properly attach door as designed.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 June 2022
Resolved 14 June 2022
Resolution: Electrical panel door was installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 June 2022
Resolved
No weights shall be added, removed, or re-located without the authorization and supervision of the cognizant Officer In Charge, Marine Inspections. MI noted 800lbs of weight added on board at the time of the inspection using trimming out the vessel. Removed weight from the vessel.
Action required: 10 - Deficiency Rectified
Resolved 7 June 2022
Resolution: Additional weights removed from the vessel prior to USCG departing the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 7 June 2022
Resolved
Placards containing instructions for donning and use of life jackets must be conspicuous places and visible to crew and passengers. Donning placards are missing.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 June 2022
Resolved 14 June 2022
Resolution: Life jacket placards installed.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 31 March 2021
Resolved
Install a visual and audible alarm at the operating station to indicate high water level in the steering room/Lazarette
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 May 2021
Resolved 17 March 2022
Resolution: High level alarm installed in the lazzerette and tested. Audible and visual alarm properly displayed on the console.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 31 March 2021
Resolved
Prove proper operation for fuel tank bilge suction.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 April 2021
Resolution: To the satisfaction of the attending Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 31 March 2021
Resolved
Replace corrosion resistant clip on water light lanyard.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 April 2021
Resolved 12 April 2021
Resolution: Corrosion resistant clip was replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 31 March 2021
Resolved
Broken window noted in the pilothouse/replace in kind.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 May 2021
Resolved 27 April 2021
Resolution: Window was replaced with re-furbished one.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 31 March 2021
Resolved
Renew batteries for life ring buoy light; expired 2016
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 April 2021
Resolved 12 April 2021
Resolution: Batteries renewed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 31 March 2021
Resolved
Remove dead ended wires under pilothouse console.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 May 2021
Resolved 12 April 2021
Resolution: Dead ended wire under the pilothouses were removed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 31 March 2021
Resolved
Each life jacket must be marked in clearly legible block capital letters with the vessel's name.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 April 2021
Resolved 2 April 2021
Resolution: Life jackets were properly marked.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 31 March 2021
Resolved
Properly mark the life jacket stowage compartment.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 April 2021
Resolved 12 April 2021
Resolution: Life jacket stowage are properly marked.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 31 March 2021
Resolved
Provide one child life jacket onboard.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 April 2021
Resolved 2 April 2021
Resolution: Child sized life jacket provided.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 31 March 2021
Resolved
Renew mast head light lens; corroded and worn
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 April 2021
Resolved 12 April 2021
Resolution: Masthead light lens was renewed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 31 March 2021
Resolved
Provide proper connection for E/R bilge alarm wires.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 April 2021
Resolved 12 April 2021
Resolution: Bilge alarm wires were properly connected.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 31 March 2021
Resolved
Renew corroded fuel lines on starboard main engine.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 April 2021
Resolved 12 April 2021
Resolution: Fuel lines were renewed.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 31 March 2021
Resolved
The owner or master shall instuct each crew member prior to getting underway for the first time on a particular vessel and at least once evry three months, as to the duties that the crew member is expected to perform in an emergency.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 April 2021
Resolution: Witnessed satisfactory man overboard drill and fire drill. Conducted training with crew.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 31 March 2021
Resolved
Connections must be made to battery terminals with permanent
type connectors. (ny-lock or nuts with lock washers will be accepted.)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 April 2021
Resolved 12 April 2021
Resolution: Permenant connections installed on baterry terminals.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 25 March 2021
Resolved
Vessel COI expired on 24Mar21. Conduct an inspection for renewal of a certificate of inspection to determine if the vessel is satisfactory condition, fit for service intended, and complies with with all applicable regulations. Vessel is restricted from carrying passengers.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 March 2021
Resolution: COI renewal was conducted on this day.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 30 July 2020
Resolved
Fire and bilge pump not operating at required PSI.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 August 2020
Resolution: Conducted maintenance on fire/bilge system and witnessed satifcatory test.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 30 July 2020
Resolved
Bilge alarm light was not operational.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 August 2020
Resolved 10 August 2020
Resolution: Witnessed satisfactory test of the bilge high level alarms.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 July 2020
Resolved
Float light lanyard clip was worn and needed replacement.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 August 2020
Resolved 10 August 2020
Resolution: Renewed float light lanyard clip.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 30 July 2020
Resolved
Remove paint from hatch dog pins.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 August 2020
Resolved 10 August 2020
Resolution: Conducted maintenance on engine room dog pins and are now freely move.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 30 July 2020
Resolved
Replace burnt out engine room lights.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 6 August 2020
Resolved 10 August 2020
Resolution: Replaced engine room light is now burning brightly.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 July 2020
Resolved
Missing fire extinguisher mount pin.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 August 2020
Resolved 10 August 2020
Resolution: Installed fire extinguisher mount pin, all sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 24 July 2020
Resolved
Vessel prohibited from passengers until annual inspection.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 24 July 2020
Resolved 30 July 2020
Resolution: The vessel received its annual inspection, satisfying the requirement.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 25 June 2019
Resolved
All engine room light not working.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 June 2019
Resolution: Engine room lights replaced.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 25 June 2019
Resolved
Mast head light out
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 June 2019
Resolution: Mast light replaced.
Engineering › Lubricating Oil Service System › Cooler
Issued 17 January 2018
Resolved
Clean L/O from port keel cooler and pressure test.
Action required: 17 - Rectify deficiencies prior to departure
Due 5 March 2018
Resolved 13 March 2018
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 17 January 2018
Resolved
Replace fire system flex loop hose at cyl.
Action required: 705 - Other - as specified
Due 5 March 2018
Resolved 13 March 2018
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 17 January 2018
Resolved
Add non-skid to ladder, main deck to pilot house
Action required: 705 - Other - as specified
Due 5 March 2018
Resolved 13 March 2018
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 17 January 2018
Resolved
Replace lifebuoy and mark properly
Action required: 705 - Other - as specified
Due 5 March 2018
Resolved 13 March 2018
Construction/Loadline › Structures › Scuttle
Issued 17 January 2018
Resolved
provide dog wrench for engine room hatch and prove operation.
Action required: 17 - Rectify deficiencies prior to departure
Due 5 March 2018
Resolved 13 March 2018
Engineering › Shafting/Propeller Arrangements › Stern Tube
Issued 17 January 2018
Resolved
Replace shaft log hoses and clamps port and stbd shaft.
Action required: 705 - Other - as specified
Due 5 March 2018
Resolved 13 March 2018
Engineering › Diesel Engine (propulsion-reduction gear) › Emergency shutdown
Issued 17 January 2018
Resolved
Replace rod and hardware on STBD MDE emergency soleniod shut down.
Action required: 705 - Other - as specified
Due 5 March 2018
Resolved 13 March 2018
Engineering › Fuel Oil Service System › Hose
Issued 17 January 2018
Resolved
Replace port and stbd fuel lines as indicated.
Action required: 705 - Other - as specified
Due 5 March 2018
Resolved 13 March 2018
Engineering › Fuel Oil Service System › Piping
Issued 17 January 2018
Resolved
Aft mid-engine room fuel piping leak at union.
Action required: 17 - Rectify deficiencies prior to departure
Due 5 March 2018
Resolved 13 March 2018
Engineering › Fuel Oil Service System › Piping
Issued 17 January 2018
Resolved
Port engine fuel piping and elbow replace
Action required: 705 - Other - as specified
Due 5 March 2018
Resolved 13 March 2018
Communications › Alarms/Indicators › Bilge Alarm
Issued 17 January 2018
Resolved
Prove proper operation of bilge alarm
Action required: 705 - Other - as specified
Due 5 March 2018
Resolved 13 March 2018
Communications › Alarms/Indicators › Fire Alarm
Issued 17 January 2018
Resolved
Prove proper operation of fire alarm.
Action required: 705 - Other - as specified
Due 5 March 2018
Resolved 13 March 2018