Records from 1998 to 2011. Most recent: inspection, 17 January 2011.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 12
17 January 2011
Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3928249
13 January 2011
NPV Safety Exam · ISPS III Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3916914
9 January 2011
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 3910488
7 July 2005
PII Safety Exam · Ballast Water Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2418260
17 October 2004
MARPOL Annex V Examination · Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2220391
18 July 2003
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1839520
18 December 2002
Ballast Water Examination · Annual Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1720678
9 November 2001
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 295057
3 July 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 119915
13 June 2000
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 278760
9 September 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 432652
28 December 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 424049
Stability › Weathertight Integrity › General
Issued 13 January 2011
Resolved
All access openings in bulkheads at the ends of enclosed superstructures are required to be weathertight when closed. The weathertight doors on "C" deck are not weathertight. The vessel is to ensure that all weathertight doors are in fact weathertight.
Action required: 705 - Other - as specified
Resolved 17 January 2011
Resolution: Weather tight stripping on the doors were replaced.
Fire Fighting › Miscellaneous Items › Insulation (Penetration of Oil/Oil Vapors)
Issued 13 January 2011
Resolved
Numerous flame screens for the fuel and ballast tanks are wasted.
Action required: 705 - Other - as specified
Resolved 17 January 2011
Resolution: Flame screens were replaced.
Construction/Loadline › Structures › Deck Plating
Issued 13 January 2011
Resolved
The supports on deck for the cables and hydraulic lines are completely wasted.
Action required: 705 - Other - as specified
Resolved 17 January 2011
Resolution: Supports were cropped and renewed.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 13 January 2011
Resolved
The fire doors in the galley do not completely close.
Action required: 705 - Other - as specified
Resolved 17 January 2011
Resolution: Firedoors in galley were adjusted to close completely.
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 17 October 2004
Resolved
Repair or replace one firesuit where the reflective material is peeling off of the firesuit and gloves. Solas 74 amd/II-2/17. Repair/replace to the satisfaction of Class/RO/RSO.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 7 July 2005
Resolution: Verified that vessel has a new fire suit.
Deck/Cargo › Holds/Tanks › Coaming
Issued 17 October 2004
Resolved
Repair to the satisfaction of class the fractures located on the four corners of the #3 hatch coaming brackets. SOLAS 74 amd I/11
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 7 July 2005
Resolution: Hatch coming inspected and fractures found to be repaired.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 17 October 2004
Resolved
Repair to the safisfaction of class the oil water seperator 15ppm sampling sensor line. There is a fast leak on the sampling line valve. MARPOL 73/78 Annex I/16.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 7 July 2005
Resolution: Verified that line no longer leaks.
Documentation › Certificates/Documents › IOPP Certificate
Issued 17 October 2004
Resolved
Update the IOPP Certificate and provide class approval of the AFT starboard fuel tank being used as a waste oil tank. Include this tank on the IOPP Certificate supplement. MARPOL 73/78 Annex I/17.
Condition: Placed in Improper Service
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 7 July 2005
Resolution: Verified that the IOPP Certificate was correct and current.
Documentation
Issued 13 June 2000
Resolved
SOLAS Safety Equipment Certificate exemption not on board.
Condition: Unknown
Due 15 June 2000
Resolved 15 June 2000
Lifesaving
Issued 13 June 2000
Resolved
Port and Starboard Lifeboat rations and pyro expired.
Condition: Unknown
Due 15 June 2000
Resolved 15 June 2000
Lifesaving
Issued 13 June 2000
Resolved
Port Life Boat davit falls aft cable damaged. Replace cable to satisfactionof class. Class to inspect and issue written report to USCG.
Condition: Unknown
Due 15 June 2000
Resolved 15 June 2000