Records from 1999 to 2023. Most recent: inspection, 10 April 2023.
Documentation record
Registered dimensions (L × B × D)143.8 ft × 36.0 ft × 11.6 ft
Registered tonnagegross 94 / net 65
ITC dimensions (L × B × D)Not recorded
ITC tonnagegross 910 / net 341
BuilderEASTERN SHIPBUILDING · BOOTHBAY HARBOR, ME, UNITED STATES · built 1976
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSITKA, AK
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 28 January 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it94 - Regulatory (Subpart C or D), Gross Ton
910 - Convention (Subpart B), Gross Ton
65 - Regulatory (Subpart C or D), Net Ton
341 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 23
10 April 2023
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7666177
16 March 2023
In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7652217
21 August 2022
Damage Survey
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7542036
11 August 2022
Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7534415
22 April 2022
Annual Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7437844
14 March 2022
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7445436
4 February 2022
Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7390982
4 October 2021
Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7317356
20 June 2021
Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7327781
22 April 2021
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7179398
13 August 2020
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7084627
19 May 2020
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6956213
17 December 2019
Construction Oversight · Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6875434
11 September 2019
Administrative Inspection · In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6809145
12 July 2019
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6747639
12 April 2019
Annual Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6654751
15 January 2019
Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6610717
28 September 2018
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6551815
2 April 2018
Annual Inspection · DAPI Audit
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6383826
22 January 2018
Internal Structural Exam · Administrative Inspection · Examination of Repairs · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6341343
28 April 2017
COI Inspection · Administrative Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6117734
6 April 2016
DAPI Audit · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5848136
3 March 2016
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5826739
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 April 2023
Resolved
VSL reported new installations for AC system and an oven. The owner of managing operator shall submit drawings, sketches, or written specifications describing the details of any proposed alterations to the cognizant OCMI and alterations must be approved. Restrict use of the AC system and oven until MSC approved plans are returned to CG inspectors.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 April 2023
Resolved 15 May 2023
Resolution: MSC approval letter sent to inspector
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 22 April 2022
Resolved
Vessel was instructed to install structural fire protection inside of bulkhead penetrations on the bridge during previous exam. Installation of the required structural fire protection was found to be not in compliance with Sub-chapter K requirements.
46CFR116.415(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2022
Resolved 2 May 2022
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 22 April 2022
Resolved
Employers must ensure that they and their crew members meet chemical testing requirements. The vessel was unable to provide evidence of the specific chemical tests that were done for each employee during the inspection.
46CFR16.203
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2022
Resolved 2 May 2022
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 22 April 2021
Resolved
Proper demonstration of fire drill and man overboard drill prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2021
Resolution: Witnessed fire and MOB drills
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 22 April 2021
Resolved
Fire pump must read 60 psi at the pump outlet. Fire pump could only produce 52 psi at the outlet. Vessel must demonstrate proper fire pump outlet pressure of 60 psi.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 May 2021
Resolution: Witnessed operation of new fire pump. Pressure was greater than 60PSI. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 April 2021
Resolved
Make boilers ready for inspection. Boiler is past inspection window.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2021
Resolution: Witnessed hydro test, fire side, waterside inspctions and safeties.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 22 April 2021
Resolved
Remove deep fat fryer or provide fire protection system in accordance with 46 CFR 181.405.
Action required: 10 - Deficiency Rectified
Resolved 22 April 2021
Resolution: Removed deep fat fryer from vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 22 April 2021
Resolved
Each generator shall be provided with a nameplate. The port generator nameplate is missing.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 May 2021
Resolved 20 June 2021
Resolution: Port generator nameplate installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 22 April 2021
Resolved
Each generator must be provided with an ammeter. Generators do not have functional ammeters.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 May 2021
Resolved 14 May 2021
Resolution: Ammeter switch was missing on the switch board. Witnessed operation of ammeter for each generator.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 22 April 2021
Resolved
Prove proper operation of oily water seperator in the presence of a marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 May 2021
Resolved 20 June 2021
Resolution: Operated oily water seperator, all sat.
08 - Alarms › N/A - No Subsystem › Emergency signal
Issued 22 April 2021
Resolved
Proper marking for fixed fire extinguishing system must be located as close to the alarm as practicable.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 May 2021
Resolved 14 May 2021
Resolution: Proper markings were installed next to alarms.
08 - Alarms › N/A - No Subsystem › Engineers' alarm
Issued 22 April 2021
Resolved
Prove proper operation of the engineering alarm system located in the engine room. Audio and visual indicators were inoperable.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 May 2021
Resolved 14 May 2021
Resolution: Witnessed operation of audible and visual engine alarm in engine room. All sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 22 April 2021
Resolved
Make all discharge piping below the freeboard deck easily accessible or operable from the weather deck. Several piping modifications in the engine room prevent easy access to overboard discharge valves.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 May 2021
Resolution: Witnessed operation of reachrods for discharge valves. All sat.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 12 July 2019
Resolved
No person may operate any vessel equipped with installed toilet facilities unless it is equipped with an operable Type II or III device. Sampling performed under the authority of the Alaska Department of [name withheld] indicates the installed MSD is not operable as fecal coliform colonies are on the order of magnitude of untreated sewage. Until such time as vessel is able to demonstrate to the Coast Guard the proper operation of the MSD, the vessel is prohibited from discharging sewage, treated or untreated, into the navigable waters of the United States. The vessel must retain onboard and/or discharge to shore facilities until such time as the Coast Guard removes this restriction. - 33 CFR 159.7(a)(1)
Action required: 705 - Other - as specified
Resolved 12 July 2019
Resolution: Deficiency overturned upon request for reconsideration.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 12 April 2019
Resolved
Batteries on upper deck for the 12V and 24V system were not fitted with fuses located as close as practicable to the battery as required by 46 CFR 120.350(g). The fuse that was installed was inside the pilot house panel and was installed in a configuration that did not match the drawing submitted to MSC. The system must be modified to locate the fuses as close as practicable to the batteries, match the configuration in the system drawing, and include fuses that meet 46 CFR 120.380(l).
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 29 April 2019
Resolved 19 April 2019
Electrical › Lighting (service) › Lighting Branch Circuit
Issued 22 January 2018
Resolved
Submit updated Electric One-Line Drawing to MSC for approval, vessel modified electric distribution system outside of previously approved drawing.
Action required: 705 - Other - as specified
Due 18 April 2018
Resolved 18 May 2020
Resolution: Rcvd approved plan
Communications › Radio Communications › EPIRB
Issued 28 April 2017
Resolved
Provide a working EPIRB (expired battery) prior to transporting revenue passengers beyond the boundary line IAW 46 CFR 117.64.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 May 2017
Resolved 3 May 2017
Resolution: Verified new EPIRB was registered and properly installed onboard vessel.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 28 April 2017
Resolved
Demonstrate proper operation of the newly installed Oily Water Separator (OWS).
Condition: Invalid
Action required: 705 - Other - as specified
Due 12 May 2017
Resolved 2 May 2017
Resolution: Pump arrived, installed, demonstration of OWS 1 1/2 gallon per minute CG approved 162/050/9054/0, sat.
Engineering › Lubricating Oil Service System › Hose
Issued 6 April 2016
Resolved
Replace hoses on port side MDE SSDG to hoses that meet J-1942.
Action required: 705 - Other - as specified
Due 1 May 2016
Resolved 12 April 2016
Resolution: Approved hoses installed on port side MDE SSDG. Unauthorized hoses removed and discarded.
Construction/Loadline › Hull › Longitudinal Frame
Issued 7 March 2016
Resolved
Crop and renew waststed bottom longitudional, first port side of CVK in aft of lazerette.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 March 2016
Resolution: Structural member replaced in kind to satisfaction of attending Inspector.
Construction/Loadline › Hull › Hull Plating
Issued 7 March 2016
Resolved
Crop and Renew in way of deck Starboard side below tonnage door.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 March 2016
Resolution: Deck plating replaced in kind to satisfaction of attending Inspector.
Construction/Loadline › Hull › Hull Plating
Issued 3 March 2016
Resolved
Observed hull plating below and adjacent to lead ballast in Void #8 to be wasted. Attaending Marine Inspector requires 06 UT shots taken below the ballast and 06 on side of the hull and send report to attending Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 March 2016
Resolution: Recieved gauging report from vessels rep [name withheld]