MAURY USCG vessel records Sign in
← All vessels

TOURMARINE

TOURMARINE is a 1998 passenger vessel (inspected). The Coast Guard has recorded 44 inspections since 2001, most recently in September 2025, along with 114 deficiencies and 4 operational controls.

Records from 2001 to 2025. Most recent: inspection, 11 September 2025.

Built
1998
Last inspected
11 September 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDQ7228
488178
Flag
UNITED STATES
367527390
Maury page id
psix-488178

Inspections, by type

…with no type recorded4
Years with a record 20 calendar years (2001–2025)
The 44 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)31.7 ft × 11.5 ft × 6.5 ft
Registered tonnagegross 15 / net 12
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderATLANTIC BOAT COMPANY · BROOKLIN, ME, UNITED STATES · built 1998
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portCABO ROJO, PR
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 12 December 2025 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it12 - Simplified, Net Ton
15 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDQ7228MMSI 367527390 · active · compulsorily equipped · granted 3 January 2026, expires 3 January 2036
WDG3569MMSI 367527390 · expired · compulsorily equipped · granted 26 April 2012, cancelled 2 July 2022
WDA5685MMSI 366822760 · expired · compulsorily equipped · granted 15 August 2001, cancelled 15 October 2011
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 44

11 September 2025 COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 8190782
27 February 2025 Deficiency Check · Administrative Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 8085617
25 February 2025 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 8085407
20 February 2025 Administrative Inspection
Administrative · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 8081907
20 February 2025 Administrative Inspection
Administrative · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 8082106
5 December 2024 Deficiency Check
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 8043687
26 November 2024 Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 8040379
1 November 2024 Administrative Inspection
Administrative · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 8028291
13 December 2023 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7838889
10 November 2022 Deficiency Check
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7594507
20 October 2022 Annual Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7580823
29 September 2022 Internal Structural Exam · Hull Examination
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7568772
1 December 2021 Annual Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7360443
13 November 2020 In-Service Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7094946
29 June 2020 Type not recorded
No type recorded · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6990436
6 December 2019 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6870515
22 November 2019 DAPI Audit
Administrative · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6870423
6 September 2019 Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6862675
4 June 2018 COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6434345
22 August 2017 Annual Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6255880
3 May 2017 Drydock Exam
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6138750
21 April 2017 Administrative Inspection
Administrative · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6129675
29 August 2016 Annual Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 5989457
9 June 2014 Annual Inspection · DAPI Audit
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 4883827
3 May 2012 Annual Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 4304557
10 December 2009 Type not recorded
No type recorded · USCGC KEY BISCAYNE (WPB 1339) - Stbd · USCG Southeast District (CGD-SE) · Activity 3662582
21 April 2009 Hull Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3521499
16 April 2009 Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3521501
14 April 2008 COI Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3184419
10 July 2007 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2990329
7 April 2007 Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2905694
14 March 2007 Hull Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2888584
23 August 2006 Type not recorded
No type recorded · USCGC MATINICUS (WPB 1315) · USCG Southeast District (CGD-SE) · Activity 2799864
9 May 2006 Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2646341
21 October 2005 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2520633
6 September 2005 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2486049
11 May 2005 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2355800
27 April 2005 Annual Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2344815
22 March 2005 Hull Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2323553
27 April 2004 Annual Inspection · Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2058358
12 February 2004 Type not recorded
No type recorded · USCGC SAPELO (WPB 1314) · USCG Southeast District (CGD-SE) · Activity 2017953
9 April 2003 Initial Certification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1778206
25 March 2003 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1769632
8 May 2001 Uninspected Other
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1063344

Deficiency record · 114

01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 11 September 2025 Resolved
Vessel was missing FCC Radio Station Authorization. Vessel's route is <100 nm from PR on Oceans Route. Vessel's radios need to be certified by FCC Technician prior to operating beyond 1000ft from shore. 46 CFR 184.502/ 47 CFR 80.13
Action required: 705 - Other - as specified
Resolved 16 March 2026
Resolution: Owner provided new FCC Cert
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 25 February 2025 Resolved
A pre-engineered fixed gas fire extinguishing system must: Automatically shut down all power ventilation systems and all engines that draw intake air from within the protected space. Fire boy system did not work as designed due to a corroded terminal. Vessel is restricted from carrying passengers until the system is operational and tested to the satisfaction of attending USCG marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 February 2025
Resolved 27 February 2025
Resolution: Operational test and override function works as designed.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 25 February 2025 Resolved
A vessel on an oceans route must carry — Six hand red flare distress signals and Six hand orange smoke distress signals or other standard specified by the Commandant. Vessel had enough flares on board, but did not have the parachute flare pistol as required. Vessel owner bought flare gun and sent photos prior to USCG returning to office.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 February 2025
Resolved 27 February 2025
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 25 February 2025 Resolved
Each ring life buoy on a vessel must: Be readily accessible and Be stowed in a way that it can be rapidly cast loose. Arrangement of ring life buoy is not satisfactory. Access path is blocked by numerous gear and ladder. Access path must be cleared or ring life buoy must be relocated. 46CFR180.70
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 February 2025
Resolved 27 February 2025
Resolution: Space cleaned and readily accessible.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 20 February 2025 Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel missed annual inspection window, vessel cannot operate until annual inspection is completed.
Action required: 17 - Rectify deficiencies prior to departure
Due 25 February 2025
Resolved 25 February 2025
Resolution: Annual inspction conducted
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 1 November 2024 Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel cannot operate until a DD/ISE inspection is completed.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 December 2024
Resolution: Vessel completed DD.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 13 December 2023 Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve. Last 5' of painter line, part of which is exposed to sun, is wasted and must be replaced.
Action required: 17 - Rectify deficiencies prior to departure
Due 14 January 2024
Resolved 18 January 2024
Resolution: Line was replaced satisfactorily.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 13 December 2023 Resolved
Each vessel that operates on the high seas must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. Hydrostatic realease unit expired in October. New unit must be installed.
Action required: 17 - Rectify deficiencies prior to departure
Due 14 January 2024
Resolved 29 December 2023
Resolution: This office receive pictural evidence of the replacement of the hydrostatic unit.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 December 2023 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Exposed dead-end wires were located in the main propulsion machinery space; bilge float that was disconnected, forward engine bay on port side, and aft engine bay port side. Wires must be properly removed to avoid electical hazards.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 January 2024
Resolved 18 January 2024
Resolution: Cables were removed from engine room.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 13 December 2023 Resolved
No person may operate a vessel that does not have a valid certificate of number for that vessel issued by the issuing authority in the State in which the vessel is principally operated. State registration expired in May. Vessel must be registered.
Action required: 17 - Rectify deficiencies prior to departure
Due 14 January 2024
Resolved 30 December 2023
Resolution: Vessel registered.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 13 December 2023 Resolved
A vessel must be operated in accordance with applicable laws and regulations and in such a manner as to afford adequate precaution against hazards that might endanger the vessel and the persons being transported. Vessel's anchor light is inoperable. Anchor lisht must be replaced.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 January 2024
Resolved 30 December 2023
Resolution: Anchor light replaced and working.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 December 2023 Resolved
An inspection for renewal of a Certificate of Inspection is conducted to determine if the vessel is in satisfactory condition, fit for the service intended, and complies with all applicable regulations. It normally includes inspection and testing of the structure, machinery, and equipment. The owner or operator must conduct all tests as required by the OCMI, and make the vessel available for all specific inspections and drills required by subpart H of this part. In addition, the OCMI may require the vessel to get underway. Vessel did not have full compliment of crew in attendence. Vessel did not get underway and conduct drills. Inspection must be completed when all crew, as required by COI, are present.
Action required: 17 - Rectify deficiencies prior to departure
Due 14 January 2024
Resolved 19 January 2024
Resolution: Completed man overboard and fire drills.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 20 October 2022 Resolved
A vessel on which a pre-engineered fixed gas fire extinguishing system is installed must have a means to reset devices used to automatically shut down ventilation systems and engines. When conducting an operational test of the pre-engineered fixed gas fire extinguishing system, the shutdown mechanism could not be overridden and left the vessel without means of propulsion. Must operate prior to carrying passengers. 46 CFR 181.420(b)(3)
Action required: 17 - Rectify deficiencies prior to departure
Due 3 November 2022
Resolved 10 November 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 October 2022 Resolved
An adult life jacket must be provided for each person carried on board a vessel. Vessel is authorized to carry 17 people and only has 15 life jackets on board. Vessel may only operate with 13 passengers and 2 crew members until 2 more life jackets are provided. 46 CFR 180.71(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 November 2022
Resolved 10 November 2022
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 20 October 2022 Resolved
A vessel on an oceans route must carry six hand red flare distress signals and 6 other approved distress signal devices for a total of 12 distress signals. Vessel carried 3 packs of 4 hand red flare distress signals, 2 packs of which expire October 31. Vessel must replace the 2 packs of distress signals that expire in October by October 31, 2022. 46 CFR 180.68(a)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 November 2022
Resolved 10 November 2022
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 20 October 2022 Resolved
The lifeline and pendants must be as furnished by the manufacturer with the approved life float. Vessel’s life float pendants are wasted and need to be replaced. Replacement lifelines and pendants must meet the requirements in Subpart 160.010 of this chapter. 46 CFR 180.175(f)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 November 2022
Resolved 10 November 2022
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 20 October 2022 Resolved
Each paddle must be lashed to the life float to which it belongs and buoyant. Vessel must lash each paddle to the life float. 46 CFR 180.175(f)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 November 2022
Resolved 10 November 2022
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 1 December 2021 Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level in a machinery space bilge, bilge well, shaft alley bilge, or other spaces subject to flooding from sea water piping within the space. During operational test of bilge system, high water level alarms were in-operable. During operational test, bilge pump discharged water in automatic mode. Bilge system's high water level alarm must be operable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 December 2021
Resolved 2 January 2022
Resolution: Bilge system's high water level alarm was replaced and works as designed..
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 December 2021 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards. MI witnessed exposed electrical wires in v-berth head. Wires must be removed or terminate the ends properly.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 December 2021
Resolved 2 January 2022
Resolution: Exposed electrical wires in v-berth head were removed.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 1 December 2021 Resolved
Deck rails must be designed and constructed to withstand a pointload of 200 pounds applied at any point in any direction, and a uniform load of 50 pounds per foot applied to the top rail in any direction. Port and starboard deck rails and aft canopy supports were loose at the mounting locations and therefore not secured to the bulwark as designed. All mounts for port and starboard deck rails and aft canopy supports must be secured using sufficient screws and washers/backing plates.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 December 2021
Resolved 2 January 2022
Resolution: All mounts for port and starboard deck rails and aft canopy supports are secured using aluminum backing plates.
09 - Working and Living Conditions › 092 - Working Conditions › Other (mooring)
Issued 1 December 2021 Resolved
A vessel must be fitted with mooring lines necessary for the vessel to be safely moored. The mooring lines provided must be satisfactory for the size of the vessel and the waters on which the vessel operates. Vessel's port mooring line is worn beyond service and must be replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 December 2021
Resolved 2 January 2022
Resolution: Vessel's mooring lines were replaced with new.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 November 2020 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 January 2021
Resolution: All crew members have been enrolled in the drug testing program.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 November 2020 Resolved
The master shall conduct sufficient drills and give sufficient instructions to make sure all crew members are familiar with their duties during emergencies that necessitate abandoning ship or the recovery of persons who have fallen overboard. No training provided for deckhand [name withheld] for this part.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 January 2021
Resolution: emergency procedures were edited and tailored tothe vessel. Captain conducted training with crew members.
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 13 November 2020 Resolved
The master shall conduct sufficient fire drills to make sure that each crew member is familiar with his or her duties in case of a fire. No training provided for deckhand [name withheld] for this part.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 January 2021
Resolution: emergency procedures were edited and tailored tothe vessel. Captain conducted training with crew members.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 November 2020 Resolved
The owner, charterer, master or managing operator shall instruct each crewmember, upon first being employed and prior to getting underway for the first time on a particular vessel and at least once every three months. Deckhand [name withheld] has not conducted crew training per this part.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 January 2021
Resolution: all crew members have been enrolled in the drug and alcohol testing program.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 6 December 2019 Resolved
Operation of propulsion engine overide feature of installed fixed extinguishing system (FireBoy)could not be demonstrated.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 November 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 December 2019 Resolved
Double clamp all vital flexible hoses (bilge hoses).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 November 2020
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 6 December 2019 Resolved
MOB and Fire Drills not conducted (nor logged).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 November 2020
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 6 December 2019 Resolved
No record of monthly EPIRB tests.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 November 2020
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 December 2019 Resolved
First Aid Kit items expired (Aspirin- 2018 & Alcohol towlettes).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 November 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 December 2019 Resolved
Insulation in way of engine turbocharger wasted.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 November 2020
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 6 December 2019 Resolved
No sound signal (installed air horn non-operational).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 November 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 December 2019 Resolved
Installed exterior electrical lighting, forward of main cabin and in way of top deck operating station inoperative.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 November 2020
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 December 2019 Resolved
Demonstrate emergency drills to the satisfaction of the attending Coast Guard Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 November 2020
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 6 December 2019 Resolved
COI not posted on vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 November 2020
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 6 December 2019 Resolved
Stability Letter not posted on vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 November 2020
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 December 2019 Resolved
Signs for fuel shut off valves wasted (and lettering too small).
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 November 2020
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 6 December 2019 Resolved
Remove remaining dead end wiring / abandoned electrical wiring under top operating station. Repair missing cover for shore tie outlet.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 November 2020
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 November 2019 Resolved
Vessel/Company not in compliance with required Coast Guard Drug and Alcohol Program requirements.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 December 2019
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 6 September 2019 Resolved
EPIRB battery and registration was expired.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 September 2019
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 6 September 2019 Resolved
Life Float net was not origional to device, as per Subchapter Q.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 September 2019
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 6 September 2019 Resolved
Anchor light as wasted. Light lens crumbled when attempting to open to gain access to change bulb.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 September 2019
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Electrical
Issued 6 September 2019 Resolved
Remove all dead end and abandoned electrical wiring.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 October 2019
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 6 September 2019 Resolved
"Weak Link" did not have documentation for type of life float device, nor did vessel owner able to provide specs on installed weak link.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 September 2019
05 - Radio Communications › N/A - No Subsystem › MF/HF Radio installation
Issued 6 September 2019 Resolved
Demonstrate proper use and installation of SSB radio.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 November 2020
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Lighting (Working spaces)
Issued 6 September 2019 Resolved
Ensure all installed electrical lighting is operational.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 September 2019
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 6 September 2019 Resolved
Provide charts for areas of navigation.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 September 2019
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 September 2019 Resolved
Install new overhead hatch in forward compartment. latches wasted.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 September 2019
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 6 September 2019 Resolved
Remove expired flares comingled with valid flares.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 September 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 September 2019 Resolved
High water bilge alarm in machinery space inoperative.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 September 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 September 2019 Resolved
Air intake hose was observed laying on top of turbocharger and melted.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 September 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 September 2019 Resolved
Thermal insulation on overhead of machinery space observed either wasted or missing sections.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 November 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 September 2019 Resolved
Install correct metaldrip/flame bowl on bottom of Racor filter and provide a marine type bronxe nut on bottom of filter.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 September 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 September 2019 Resolved
Provide covers for installed batteries.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 September 2019
Lifesaving › Hand Flares › Not on Board
Issued 22 August 2017 Resolved
Obtain 4 valid additional flares
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 August 2017
Resolution: Deficiency Rectified
Lifesaving › Lifefloat › Painter
Issued 22 August 2017 Resolved
Replace polypropylene Life Float painter line
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 August 2017
Resolution: Deficiency Rectified
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 22 August 2017 Resolved
Prove proper operation of engine room vent closures
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 August 2017
Resolution: Deficiency Rectified
Navigation › Piloting/Steering › Magnetic Compass
Issued 22 August 2017 Resolved
Prove proper operation of lighted magnetic compass
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 August 2017
Resolution: Deficiency Rectified
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 22 August 2017 Resolved
Prove proper operation of vessels stern/anchor light
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 August 2017
Resolution: Deficiency Rectified
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 21 April 2017 Resolved
Obtain a valid Certificate of Documentation.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 April 2017
Resolved 25 May 2017
Resolution: Vessel obtained valid Certificate of Documentation
Engineering › Fuel Oil Service System › Filter
Issued 29 August 2016 Resolved
Install Flame Bowl on CG approved Racor fuel filter
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 September 2016
Resolution: Installed new Flame Bowl on fuel filter.
Engineering › Fuel Oil Service System › Hose
Issued 29 August 2016 Resolved
Install CG Approved flexible fuel oil lines on MDE.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 September 2016
Resolution: New Approved hoses installed
Fire Fighting › Fire Bucket › Stenciling
Issued 29 August 2016 Resolved
Stencil 2.5 Gallon Fire Buckets
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 September 2016
Resolution: New fire buckets on board
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 29 August 2016 Resolved
Prove proper operation of aft engine room vent closures
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 September 2016
Resolution: engine room vent closures operational.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 29 August 2016 Resolved
Obtain valid 6v float Life Ring Float Light battery
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 September 2016
Resolution: Battery replaced with valid one.
Lifesaving › Lifefloat › Pendant
Issued 29 August 2016 Resolved
Replace Polypropylene Life Float line
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 September 2016
Resolution: New Polypropylene Life Float lines installed.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 29 August 2016 Resolved
Mark emergency exit in forward cabin
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 September 2016
Resolution: Emergency exit in forward cabin marked and labeled.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 29 August 2016 Resolved
Obtain CG approved first aid kit
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 September 2016
Resolution: Approved First Aid kit onboard
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 14 April 2008 Resolved
Repair or replace water ligths for lifejackets. Upon inspection, noted (3) not working properly.
Condition: Improper/Lack of Maintenance
Due 14 April 2008
Resolved 14 April 2008
Resolution: Crewmember clean contacts and change batteries. All corrected.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 14 April 2008 Resolved
Repair waterlight for lifebuoy. Upon inspection, noted light working correctly. The light had to be tapped on the sides to make to work.
Condition: Design Flaw
Due 14 April 2008
Resolved 14 April 2008
Resolution: Crew member inspected light and found a broken contact and repaired.
Documentation › Certificates/Documents › FCC SSL
Issued 14 April 2008 Resolved
Provide FCC Safety Certificate. Current certificate onboard expired on 10 Apr 08.
Due 21 April 2008
Resolved 30 April 2008
Resolution: Received new certificate to expire 23Apr09.
Communications › Radio Communications › EPIRB
Issued 7 April 2007 Resolved
Provide EPIRB in float free arrangement: Current hydrostatic release unit expired 30Mar07.
Action required: 705 - Other - as specified
Due 23 April 2007
Resolved 10 May 2007
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 7 April 2007 Resolved
Provide fuel shut-off valve at the engine for main fuel service line. 46 CFR 182.455(b)(4).
Action required: 705 - Other - as specified
Due 9 May 2007
Resolved 10 May 2007
Operations/Management › Equipment Service/Testing › EPIRB
Issued 7 April 2007 Resolved
Provide onboard record of required gear inspections including monthly EPIRB test/inspections, monthly inspections of portable fire extinguishers, weekly inspections of survival craft.
Action required: 705 - Other - as specified
Due 9 May 2007
Resolved 10 May 2007
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 7 April 2007 Resolved
Provide onboard vessel-specific emergency instructions (may use template provided by marine inspector). 46 CFR 185.510.
Action required: 705 - Other - as specified
Due 9 May 2007
Resolved 10 May 2007
Engineering › Fuel Oil Storage/Transfer System › Ventilation
Issued 14 March 2007 Resolved
Replace flame screens in port and stbd fuel oil tank vents.
Condition: Damaged By Earlier Event
Due 13 April 2007
Resolved 7 April 2007
Construction/Loadline › Structures › Transverse Bulkhead
Issued 14 March 2007 Resolved
Seal collision bulkhead holes to make watertight. Seal holes at both ends.
Condition: Improper Installation
Due 13 April 2007
Resolved 7 April 2007
Documentation › Logs/Records › Logbook (official)
Issued 27 April 2005 Resolved
Provide updated bridge log with required monthly drills to include fire, man overboard and steering test.
Condition: Improper/Lack of Maintenance
Due 27 May 2005
Resolved 27 May 2005
Resolution: Provided.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 27 April 2005 Resolved
Paint in black matte side shields for the naviagation lights.
Condition: Improper Installation
Due 27 May 2005
Resolved 11 May 2005
Resolution: Shields painted.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 27 April 2005 Resolved
Replace port, starboard and aft safet rails with stronger lines or chain to be able to withstand 200lbs.
Condition: Improper Installation
Due 27 May 2005
Resolved 27 May 2005
Resolution: Replaced.
Lifesaving › Lifefloat › Markings
Issued 27 April 2005 Resolved
Provide Coast Guard approval number for lifefloat or replace lifefloat with an approved lifefloat.
Condition: Damaged By Earlier Event
Due 16 June 2005
Resolved 6 September 2005
Resolution: New lifefloat provided.
Lifesaving › Lifefloat › Float-free Link
Issued 27 April 2005 Resolved
Provide an appoved weaklink to lifefloat.
Condition: Improper Installation
Due 13 September 2005
Resolved 21 October 2005
Resolution: New weaklink provided.
Lifesaving › Lifefloat › Retroreflective Material
Issued 27 April 2005 Resolved
Replace reflective tape to lifefloat.
Condition: Design Flaw
Due 16 June 2005
Resolved 6 September 2005
Resolution: New lifefloat provided.
Lifesaving › Lifefloat › Approval
Issued 27 April 2005 Resolved
Patch holes in lifefloat.
Condition: Damaged By Earlier Event
Due 16 June 2005
Resolved 6 September 2005
Resolution: New lifefloat provided.
Fire Fighting › Remote Fuel Shutoff › General
Issued 27 April 2005 Resolved
Label remote emergency fuel shutoff valves with purpose and direction of operation.
Condition: Improper/Lack of Maintenance
Due 27 May 2005
Resolved 27 May 2005
Resolution: Labeled.
Stability › Weathertight Integrity › General
Issued 27 April 2005 Resolved
Trim engine room hatch frame so that frame does not contact main engine exhaust pipe.
Condition: Improper Installation
Due 27 May 2005
Resolved 27 May 2005
Resolution: Trimed.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 27 April 2005 Resolved
Re-laminate exhaust pipe where main deck hatch frame made a cut.
Condition: Improper Installation
Due 27 May 2005
Resolved 27 May 2005
Resolution: Repaired.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 27 April 2005 Resolved
Replace expire light to three (03) adult lifejackets. Date on light showed expired, but when tested, tested sat.
Condition: Improper/Lack of Maintenance
Due 27 May 2005
Resolved 27 May 2005
Resolution: Provided.
Stability › Watertight Integrity › General
Issued 22 March 2005 Resolved
Seal and provide fasteners to secure hatch to collision bulkhead.
Condition: Improper Installation
Due 7 May 2005
Resolved 11 May 2005
Resolution: Hatch secured with fasteners and a silicone gasket.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 22 March 2005 Resolved
Provide seal to main deck hatches to make them weathertight.
Condition: Improper Installation
Due 18 May 2005
Resolved 27 May 2005
Resolution: New seals provided.
Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 22 March 2005 Resolved
Provide evidence of enrollment in a drug testing consortium.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 March 2005
Resolution: Evidence provided.
Engineering › Steering Gear System › Rudder
Issued 22 March 2005 Resolved
Adjust rudder to eliminate excesive play at seal or replace seal. To be corrected prior in placing the vsl back in the water.
Action required: 705 - Other - as specified
Due 22 March 2005
Resolved 24 March 2005
Resolution: Received statement from mechanic attesting to adjustment to rudder seal.
Personnel › Manning/Qualifications
Issued 27 April 2004 Resolved
Provide a deckhand as per COI.
Due 27 April 2004
Resolved 12 May 2004
Resolution: Provided.
Operations/Management › Drills/Instruction
Issued 27 April 2004 Resolved
Conduct required underway drills (fire, abandon ship, man overboard, and disabled master), in the presence of a Coast Guard Marine Inspector. LEGACY COMPONENT DESC: Underway Drills
Due 27 April 2004
Resolved 12 May 2004
Resolution: Drills done w/ sat results.
Operations/Management › Drug and Alcohol Testing
Issued 27 April 2004 Resolved
Enroll deckhand in a drug and alcohol testing consortium. LEGACY COMPONENT DESC: Proof of Enrollment
Condition: Unknown
Due 27 April 2004
Resolved 12 May 2004
Resolution: Deckhand enrolled in the Maritime Consortium.
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 27 April 2004 Resolved
Service the fixed fire fighting system and provide a servide certificate. LEGACY COMPONENT DESC: Service
Condition: Improper/Lack of Maintenance
Due 27 April 2004
Resolved 12 May 2004
Resolution: Done and certificate provided.
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 27 April 2004 Resolved
Service portable fire extinguishers and provide a service report. LEGACY COMPONENT DESC: Service
Condition: Improper/Lack of Maintenance
Due 27 April 2004
Resolved 12 May 2004
Resolution: Done and certificate provided.
Documentation › Certificates/Documents
Issued 27 April 2004 Resolved
Provide a valid Certificate of Documentation prior in carrying any passenger for hire. LEGACY COMPONENT DESC: Certificate of Documentation (CG-1270)
Condition: Improper/Lack of Maintenance
Due 27 April 2004
Resolved 12 May 2004
Resolution: Provided.
Accommodation/Occupational Safety › Medical/First Aid
Issued 27 April 2004 Resolved
Provide a Coast Guard or equivalent first aid kit. LEGACY COMPONENT DESC: Medicine Chest
Condition: Improper/Lack of Maintenance
Due 11 May 2004
Resolved 12 May 2004
Resolution: An equivalent kit provided.
Lifesaving › Lifejacket/PFD (Type I)
Issued 27 April 2004 Resolved
Provide lights for child lifejackets (2ea). Vsl restricted to daylight opertation only when carrying any child until requirement is corrected. LEGACY COMPONENT DESC: Lights
Condition: Improper/Lack of Maintenance
Due 27 April 2004
Resolved 12 May 2004
Resolution: Provided.
Accommodation/Occupational Safety › Occupational Safety
Issued 27 April 2004 Resolved
Provide additional safety rail courses so that no open space of 12 inches or more exist to port, starboard, and aft rails. LEGACY COMPONENT DESC: Deck Rail
Condition: Improper Installation
Due 11 May 2004
Resolved 12 May 2004
Resolution: Provided.
Fire Fighting › Ventilation Systems
Issued 27 April 2004 Resolved
Provide a 30x30 mesh screen to fuel tank vents, port and starboard. Vents to terminate on the hull exterior as high above the waterline as possible. LEGACY COMPONENT DESC: Fuel tank Vents
Condition: Improper Installation
Due 11 May 2004
Resolved 12 May 2004
Resolution: Provided.
Engineering › Fuel Oil Storage/Transfer System
Issued 27 April 2004 Resolved
Label remote emergency fuel shutoff valves with purpose of valves and direction of operation. LEGACY COMPONENT DESC: Valve
Condition: Improper/Lack of Maintenance
Due 11 May 2004
Resolved 12 May 2004
Resolution: Done..
Engineering › Bilge Water Management System
Issued 27 April 2004 Resolved
Repair the steering room bilge pump float so that pump will operate automatically. LEGACY COMPONENT DESC: Pump
Condition: Improper/Lack of Maintenance
Due 11 May 2004
Resolved 12 May 2004
Resolution: Repaired and tested.
Documentation › Certificates/Documents
Issued 9 April 2003 Resolved
Provide FCC Safety Certificate.
Condition: Unknown
Due 9 May 2003
Resolved 24 April 2003
Resolution: Recieved copy of new certificate.
Personnel › Certificates/Documents/Licenses
Issued 9 April 2003 Resolved
Enroll crewmember under the vessel's drug testing program.
Condition: Unknown
Due 9 May 2003
Resolved 12 May 2003
Resolution: Evidence received of enrollement.
Documentation › Logs/Records
Issued 9 April 2003 Resolved
Provide logbook for lifesaving equipment inspections and to log required drills. LEGACY COMPONENT DESC: Logbook (official)
Condition: Unknown
Due 9 May 2003
Resolved 24 April 2003
Resolution: Received proof of purchase.
Lifesaving › Hand Flares
Issued 9 April 2003 Resolved
Provide six red hand held flares. LEGACY COMPONENT DESC: Quantity
Condition: Improper/Lack of Maintenance
Due 9 May 2003
Resolved 12 May 2003
Resolution: Received via fax proof of purchase.
Lifesaving › Hand Flares
Issued 9 April 2003 Resolved
Provide six orange hand held smokes. LEGACY COMPONENT DESC: Quantity
Condition: Improper/Lack of Maintenance
Due 9 May 2003
Resolved 12 May 2003
Resolution: Received proof of purchase.
Lifesaving › Buoyant Apparatus
Issued 9 April 2003 Resolved
Provide additional lifefloat to accomodate 100% of the persons requested (20) with required equipment (4-foot paddles and waterlight). Vesl restrictd to carry max persons of 12 until lifefloat is provided and verfied by Marine Inspector.
Condition: Unknown
Due 9 May 2003
Resolved 24 April 2003
Resolution: Item not required since owner intends to operate w/ 10 passengers only due to finance contrains.
Lifesaving › Buoyant Apparatus
Issued 9 April 2003 Resolved
Stencil vessel name on life-float paddles.
Condition: Improper/Lack of Maintenance
Due 9 May 2003
Resolved 24 April 2003
Resolution: Done
Lifesaving › Lifejacket/PFD (General)
Issued 9 April 2003 Resolved
Provide six additional adults lifekjackets with light. LEGACY COMPONENT DESC: Quantity
Condition: Improper/Lack of Maintenance
Due 9 May 2003
Resolved 24 April 2003
Resolution: Items not required since owner will carry a mx of 10 passengers with 2 crewmembers.
Lifesaving › Lifejacket/PFD (General)
Issued 9 April 2003 Resolved
Separate and Identify storage area for the adult and child life jackets. LEGACY COMPONENT DESC: Storage
Condition: Improper Installation
Due 9 May 2003
Resolved 24 April 2003
Resolution: Done
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 9 April 2003 Resolved
Provide one portable B-II fire extinguisher. Extinguisher must be provided prior to carry passengers for hire.
Condition: Improper/Lack of Maintenance
Due 10 April 2003
Resolved 24 April 2003
Resolution: Recieved proof of purchase.