MAURY USCG vessel records
← All vessels

RESOLUTE

RESOLUTE is a 1976 passenger vessel (inspected). The Coast Guard has recorded 18 inspections since 2016, most recently in December 2025, along with 16 deficiencies and 1 casualty investigation in 2017.

Records from 2016 to 2025. Most recent: inspection, 8 December 2025.

Built
1976
Last inspected
8 December 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 8 December 2025
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 7 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDN9736
Flag
UNITED STATES
Maury page id
psix-48823

Documentation record

Registered dimensions (L × B × D)26.8 ft × 10.8 ft × 5.1 ft
Registered tonnagegross 7 / net 6
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJARVIS NEWMAN · SOUTHWEST HARBOR, ME, UNITED STATES · built 1976
Hull materialFRP (Fiberglass)
PropulsionAuxiliary Sail
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portRIO, FL
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 25 September 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it7 - Regulatory (Subpart C or D), Gross Ton
6 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 18

8 December 2025 Type not recorded
No type recorded · Station Fort Pierce · USCG Southeast District (CGD-SE) · Activity 8278851
7 October 2025 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8248836
5 September 2025 Appeal
Administrative · Commandant (CG-CVC) · Activity 8227981
29 May 2025 Administrative Inspection · Appeal
Administrative · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8147341
10 January 2025 Hull Examination · Internal Structural Exam · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8062171
17 October 2024 Deficiency Check · DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8020732
2 October 2023 Appeal · Administrative Inspection
Administrative · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7824887
19 September 2023 Appeal · Administrative Inspection
Administrative · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7824879
15 September 2023 Appeal · Administrative Inspection
Administrative · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7824863
23 January 2023 DAPI Audit · Internal Structural Exam · Administrative Inspection · Simplified Stability Test · Deficiency Check · Initial Certification · Drydock Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7627198
17 October 2022 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7578973
4 September 2018 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6531596
23 April 2018 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6398155
23 August 2017 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6251141
11 August 2017 In-Service Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6240190
16 August 2016 Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5974953
21 April 2016 Hull Examination · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5859490
10 March 2016 Drydock Extension
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5830522

Deficiency record · 16

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 October 2024 Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 1" high indicating the purpose of the valve and direction of operation. Shut off not labeled.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 October 2024
Resolution: Markings made.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 17 October 2024 Resolved
Each life ring on a vessel must be approved in accordance with 160.050 in Subchapter Q of this chapter. Ring buoy’s grab line supports were deteriorated.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 October 2024
Resolution: Rreplaced grab lines on the life ring.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 17 October 2024 Resolved
The employer shall provide EAP for all crew members. There is no evidence of a EAP program in place, no evidence of supervisory personnel receiving 60 min of training.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 October 2024
Resolution: Suprrvisor training confirmed and EAP program in place.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 17 October 2024 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up to date: U.S. Coast Pilot or similar publication, Coast Guard light list. Vessel missing Coast Pilot.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 October 2024
Resolution: Pubs onboard.
01 - Certificates & Documentation › 013 - Documents › Shipboard working arrangements
Issued 25 September 2023 Resolved
The owner shall, prior to receiving a COI, submit for approval to the cognizant OCMI, at least two copies of the following plans, manuals, analyses, and calculations that are applicable to the vessel as determined by the OCMI: (12) On sailing vessels: (i) Masts, including integration into the ship’s structure; and (ii) Rigging plan showing all areas and centers of effort as well as the arrangement, dimension, and connections of the standing rigging. Owner could not produce these approved plans. Owner may submit them to MSC directly or submit to MSC through OCMI and upon approval, provide them to the attending marine inspector. Due to vessel being under less than 65’ owner may submit specifications, sketches, photographs, line drawings or written descriptions instead of any required drawings, provided the required information is adequately detailed and acceptable to the cognizant OCMI, 46 CFR 177.202(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 October 2023
Resolution: Plans examined locally. Sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 September 2023 Resolved
The OCMI may require an inspection and testing whenever a repair or alteration is undertaken. Jib sail is not replaced in kind. Submit new sail plan to MSC with smaller Jib sail dimensions. Vessel is prohibited from using Aux sails.
Action required: 705 - Other - as specified
Resolved 26 October 2023
Resolution: Correct size Jib installed. Def no longer applicable
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 September 2023 Resolved
At each initial and subsequent inspection for certification of a vessel the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances, including the following: Inspections of the conditions of the superstructure, masts, and similar arrangements constructed on the hull, and on a sailing vessel all spars, standing rigging, running rigging, blocks, fittings, and sails. Unable to complete inspection as vessel is missing its required Jib sail. Current Jib installed is not of the size of submitted sail plan and is not replaced inkind. Vessel is prohibited from aux sail power.
Action required: 705 - Other - as specified
Resolved 26 October 2023
Resolution: New correct size Jib installed.
04 - Emergency Systems › N/A - No Subsystem › Emergency steering position com./ compass reading
Issued 17 September 2023 Resolved
Except as provided in paragraph C of this section, a vessel must be provided with an auxiliary means of steering that is: (b) A suitable hand tiller may be acceptable as the auxiliary means of steering where satisfactory to the cognizant OCMI. Vessel has a single rudder and is not provided with an auxiliary means of steering.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 September 2023
Resolution: Owner produced tools neccessary to act as aux steering.
Sail Rigging › Running Rigging › Splices
Issued 23 August 2017 Resolved
Provide preventative maintenance for rigging maintenance and inspection.
Action required: 705 - Other - as specified
Due 22 September 2017
Resolved 7 September 2017
Resolution: Vessel owner provided preventative maintenance for rigging maintenance and inspection.
Electrical › Electrical Distribution System (service) › Wiring
Issued 23 August 2017 Resolved
Properly terminate wire connecting old horn in the junction box to assure safety.
Action required: 705 - Other - as specified
Due 22 September 2017
Resolved 7 September 2017
Resolution: Vessel owner terminated wire in box.
Engineering › Steering Gear System › Rudder
Issued 11 August 2017 Resolved
Find reason for banging and limited propulsion/steering. Provide written report detailing any damage.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 August 2017
Resolution: Vessel owner sent CG-2692 and statement from diver to marine inspector.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 16 August 2016 Resolved
Engine did not start after switching to 'override' on fixed firefighting system.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 August 2016
Resolved 30 August 2016
Resolution: Verified operation of override.
Sail Rigging › Stays/Shrouds › Wires
Issued 16 August 2016 Resolved
Thimble on lower bobstay was cracked on top and bottom and wire rope was beginning to spread out. Renew both.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 August 2016
Resolved 30 August 2016
Resolution: Lower bobstay was replaced.
Lifesaving › Hand Flares › Expired
Issued 16 August 2016 Resolved
All 3 red flares were expired. Only daylight operations permitted until flares are replaced.
Action required: 705 - Other - as specified
Due 30 August 2016
Resolved 30 August 2016
Resolution: Verified flares were not expired.
Construction/Loadline › Structures › Deck Plating
Issued 21 April 2016 Resolved
02 frames on port side inside cabin are rotted. Repair/replace to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 May 2016
Resolved 26 April 2016
Resolution: 02 frames were replaced.
Construction/Loadline › Hull › Transverse Frame
Issued 21 April 2016 Resolved
Port side FWD in cabin overhead deck is showing signs of water intrusion. Plywood has rot, repair/replace to the satisfaction of attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 May 2016
Resolved 26 April 2016
Resolution: The rotted section of plywood under the FRP deck was cropped out and replaced. FRP was repaired.

Casualty record · 1

23 August 2017Routine · role: Involved in a Marine Casualty · activity 6251141
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record