KETIVIK

KETIVIK is a 1976 tank ship. The Coast Guard has recorded 31 inspections since 1985, most recently in September 2025, along with 79 deficiencies and 1 casualty investigation in 2015.

Records from 1985 to 2025. Most recent: inspection, 11 September 2025.

Built
1976
Last inspected
11 September 2025
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

Flag
UNITED STATES
—
Maury page id
psix-48824

Inspections, by type

…with no type recorded5
Years with a record 23 calendar years (1985–2025)
The 31 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it19 - Regulatory (Subpart C or D), Gross Ton
13 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 31

11 September 2025 Administrative Inspection · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8231787
14 October 2015 Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5775639
20 January 2009 Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3397103
25 October 2006 Administrative Inspection · Deficiency Check · Annual Inspection · MARPOL Annex V Examination
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 2809501
7 October 2005 COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 2327998
2 August 2004 Annual Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 2153939
6 July 2004 In-Service Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 2123439
10 July 2003 Re-Inspection · Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1935529
7 August 2002 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1951135
22 July 2002 Annual Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1650473
19 July 2001 Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1376681
5 September 2000 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 169454
18 June 2000 COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 821022
21 June 1999 Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1365363
29 June 1998 COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1437471
31 December 1997 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 783775
12 June 1997 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1422979
11 July 1994 Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1176346
1 July 1993 COI Inspection · Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 843087
28 August 1992 Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1265182
27 August 1992 Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 954188
22 May 1992 Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1267686
3 July 1991 COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1001028
29 June 1990 Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 928371
8 July 1989 COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1208498
9 July 1988 Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1202751
13 May 1988 Hull Examination · Examination of Repairs · Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1195810
16 November 1987 Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1023712
7 July 1987 COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1011169
10 July 1986 Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 993355
8 July 1985 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 985473

Deficiency record · 79

Operations/Management › Drug and Alcohol Testing › Testing, Substances
Issued 25 October 2006 Resolved
Provide proof of drug testing program meets DOT standard.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 November 2006
Resolved 17 May 2007
Resolution: The crew is being put into a seperate random pool.
Deck/Cargo › Cargo Stowage › General
Issued 25 October 2006 Resolved
Provide cargo gear certificate.
Due 10 November 2006
Resolved 20 June 2007
Resolution: Cleared via email from [name withheld] stating that he has the required paperwork.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 25 October 2006 Resolved
Prove proper operation of stern light.
Due 25 November 2006
Resolved 20 June 2007
Resolution: Cleared via email from [name withheld].
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 25 October 2006 Resolved
Provide proof of benzene monitoring program
Due 25 November 2006
Resolved 25 June 2007
Resolution: Cleared deficiency via email from [name withheld].
Pollution Prevention/Response › Prevention Equipment › Coamings
Issued 25 October 2006 Resolved
Relocate cargo vent vent inside of containment.
Due 25 November 2006
Resolved 20 June 2007
Resolution: Cleared via an email from [name withheld].
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 25 October 2006 Resolved
Hydrostatically test nitrogen bottle for dry chemical fire extinguisher.
Action required: 17 - Rectify deficiencies prior to departure
Due 25 November 2006
Resolved 20 June 2007
Resolution: Cleared via an email from [name withheld].
Construction/Loadline › Structures › Superstructure
Issued 25 October 2006 Resolved
Replace window glass in pilot house.
Due 25 November 2006
Resolved 20 June 2007
Resolution: Cleared via an email from [name withheld].
Construction/Loadline › Penetrations › Flange Pad
Issued 25 October 2006 Resolved
Replace cap on hydraulic tank with cap made of non-combustible material.
Due 25 November 2006
Resolved 20 June 2007
Resolution: Cleared via an email from [name withheld].
Electrical › Electrical Distribution System (service) › Conductor
Issued 25 October 2006 Resolved
Remove or place in junction box dead end wire in way of aft bulkhead.
Due 25 November 2006
Resolved 20 June 2007
Resolution: Cleared via an email from [name withheld].
Construction/Loadline › Penetrations › Valve Flange
Issued 25 October 2006 Resolved
Repair F/O shutoff for main diesel engines.
Action required: 17 - Rectify deficiencies prior to departure
Due 25 October 2006
Resolved 20 June 2007
Resolution: Cleared via an email from [name withheld].
Fire Fighting › Fixed Fire Detection System › Detector/Call Point Grouping
Issued 25 October 2006 Resolved
Provide audible and visual alarm for fixed fire fighting in engine room.
Action required: 17 - Rectify deficiencies prior to departure
Due 25 November 2006
Resolved 20 June 2007
Resolution: Cleared via an email from [name withheld].
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 7 October 2005 Resolved
Provide proof of first aid/CPR cards for 50% of the crew.
Due 1 May 2006
Resolved 11 September 2025
Resolution: CPR training was held.
Operations/Management › Drills/Instruction › Not Conducted
Issued 7 October 2005 Resolved
Log training and lifesaving equipment maintenance.
Due 1 May 2006
Resolved 22 June 2006
Resolution: Logs were placed on the vessel.
Lifesaving › Lifebuoys › Approval
Issued 7 October 2005 Resolved
Replace white life rings with orange.
Due 1 May 2006
Resolved 1 May 2006
Resolution: The white life ring was replaced with an orange.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 7 October 2005 Resolved
Prove proper operation of stern light.
Due 1 May 2006
Resolved 1 May 2006
Resolution: The wiring was repaired for the stern light.
Navigation › Collision/Grounding Avoidance › Radar
Issued 7 October 2005 Resolved
Prove proper operation of radar.
Due 1 May 2006
Resolved 6 June 2006
Resolution: The radar was repaired.
Fire Fighting › Ventilation Systems › Ducts
Issued 7 October 2005 Resolved
Provide securing devices for engine room ventilation.
Due 1 May 2006
Resolved 22 June 2006
Resolution: Securing devices were installed.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 7 October 2005 Resolved
provide four pfd's.
Due 1 May 2006
Resolved 1 May 2006
Resolution: Four new pfd''s were placed on the vessel.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 7 October 2005 Resolved
Repair port cable at bow.
Due 1 May 2006
Resolved 22 June 2006
Resolution: The port cable was repaired.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 7 October 2005 Resolved
Prove proper operation of fixed fire fighting system.
Due 1 May 2006
Resolved 22 June 2006
Resolution: A firefighting servicing company checked the operation of the system.
Fire Fighting › Fire Bucket › Stenciling
Issued 7 October 2005 Resolved
Label firefighting buckets with vessel name.
Due 1 May 2006
Resolved 22 June 2006
Resolution: Firefighting buckets were label with the vessels name.
Engineering › Fuel Oil Service System › Piping
Issued 7 October 2005 Resolved
Mark fuel shutoffs with 2 inch letters.
Due 1 May 2006
Resolved 22 June 2006
Resolution: The fuel shutoffs were labeled.
Fire Fighting › Ventilation Systems › Fans
Issued 7 October 2005 Resolved
make forced exhaust shutdown upon energizing fixed firefighting system.
Due 1 May 2006
Resolved 22 June 2006
Resolution: The forced exhaust shutdown was installed.
Stability › Unintentional Flooding › General
Issued 7 October 2005 Resolved
Install pipe plug in valve in fwd bulkhead of engine room.
Due 1 May 2006
Resolved 22 June 2006
Resolution: A pipe plug was installed in the valve.
Operations/Management › Drills/Instruction › Safety Orientation
Issued 7 October 2005 Resolved
Provide emergancy instructions.
Due 1 May 2006
Resolved 1 May 2006
Resolution: Emergency instructions were posted.
Navigation
Issued 18 June 2000 Resolved
MISSING VHF RADIO
Condition: Unknown
Due 18 June 2000
Resolved 23 August 2000
Construction/Loadline
Issued 18 June 2000 Resolved
PROVE PROPER OPERATION BILGE ALARM.
Condition: Unknown
Due 18 June 2000
Resolved 23 August 2000
Engineering
Issued 18 June 2000 Resolved
REPAIR WATER LEAK FROM BOTH SHAFT STUFFING BOXES.
Condition: Unknown
Due 18 June 2000
Resolved 23 August 2000
Navigation
Issued 18 June 2000 Resolved
REPAIR/REPLACE P/S RUNNING LIGHTS.
Condition: Unknown
Due 18 June 2000
Resolved 23 August 2000
Construction/Loadline
Issued 18 June 2000 Resolved
PROVIDE MIN 5GAL/MIN PARTABLE BILGE PUMP AT LEAST A 6' SUCTION HOSE.
Condition: Unknown
Due 18 June 2000
Resolved 23 August 2000
Construction/Loadline
Issued 21 June 1999 Resolved
PROVE PROPER OPERATION OF MAIN BALLAST PUMP.
Condition: Unknown
Due 10 July 1999
Resolved 14 September 1999
Lifesaving
Issued 21 June 1999 Resolved
PAINT FLARE BOX ORANGE: LABEL "DISTRESS SIGNALS".
Condition: Unknown
Due 10 July 1999
Resolved 14 September 1999
Electrical
Issued 21 June 1999 Resolved
LABEL MAIN CIRCUIT PANEL IN WHEELHOUSE.
Condition: Unknown
Due 10 July 1999
Resolved 14 September 1999
Deck/Cargo
Issued 21 June 1999 Resolved
MOUSE ALL STANDING RIGGING SCREW-PIN SHACKLES.
Condition: Unknown
Due 10 July 1999
Resolved 14 September 1999
Navigation
Issued 21 June 1999 Resolved
REPLACE UNDERSIZED COTTER KEY WITH PROPER SIZE - PORT STEERING ARM.
Condition: Unknown
Due 10 July 1999
Resolved 14 September 1999
Deck/Cargo
Issued 21 June 1999 Resolved
REPLACE UNDERSIZED TURNBUCKLE BOLT STARBOARD SIDE RAMP.
Condition: Unknown
Due 10 July 1999
Resolved 14 September 1999
Construction/Loadline
Issued 21 June 1999 Resolved
PROVE PROPER OPERATION OF HIGH WATER ALARM.
Condition: Unknown
Due 10 July 1999
Resolved 14 September 1999
Lifesaving
Issued 21 June 1999 Resolved
INSTALL RETRO-REFLECTIVE TAPE ON BOTH RING BUOYS - SPLICE LINE AROUND BODY OF RING - PUT PROPER NAME OF VESSEL ON STARBOARD SIDE RING BUOY.
Condition: Unknown
Due 10 July 1999
Resolved 14 September 1999
Deck/Cargo
Issued 21 June 1999 Resolved
REPLACE PINCHED HEAD WIRE.
Condition: Unknown
Due 10 July 1999
Resolved 14 September 1999
Lifesaving
Issued 12 June 1997 Resolved
POST "NO SMOKING" SIGNS ON FRONT EXTERIOR OF WHEELHOUSE.
Condition: Unknown
Due 12 June 1997
Resolved 12 June 1997
Lifesaving
Issued 12 June 1997 Resolved
CONSPICUOSLY MARK CARGO PUMP SHUTDOWN ON MAIN DECK.
Condition: Unknown
Due 12 June 1997
Resolved 12 June 1997
Construction/Loadline
Issued 12 June 1997 Resolved
MARK AND IDENTIFY ALL VALVES ON BILGE AND BALLASE SYSTEM.
Condition: Unknown
Due 12 June 1997
Resolved 12 June 1997
Documentation
Issued 12 June 1997 Resolved
RENEW DOCUMENTATION. LAST DOCUMENTED IN 1994.
Condition: Unknown
Due 12 June 1997
Resolved 12 June 1997
Engineering
Issued 12 June 1997 Resolved
INSTALL METAL PLUG VS. PLASTIC PLUG IN RACOR FUEL FILTER. ALSO REINSTALL METAL FLAME IMPINGEMENT BOWL.
Condition: Unknown
Due 12 June 1997
Resolved 12 June 1997
Deck/Cargo
Issued 12 June 1997 Resolved
INSTALL A LEAK DETECTION SYSTEM IN VOID AREA AROUND FUEL (CARGO) TANK TO SHOW BOTH THE PRESENCE OF FUEL AND FLAMABLE VAPORS.
Condition: Unknown
Due 12 June 1997
Resolved 12 June 1997
Deck/Cargo
Issued 12 June 1997 Resolved
REPLACE ALL ELECTRIC DECK WINCHES WITH EXPLOSION PROOF WINCH MOTORS OR HYDRAULIC WINCHES.
Condition: Unknown
Due 12 June 1997
Resolved 12 June 1997
Fire Fighting
Issued 12 June 1997 Resolved
INSTALL FIXED FIRE EXTINGUISHING SYSTEM IN ENGINE ROOM.
Condition: Unknown
Due 12 June 1997
Resolved 12 June 1997
Fire Fighting
Issued 12 June 1997 Resolved
SERVICE ALL PORTABLE AND SEMI-PORTABLE FIRE EXTINGUISHERS._x001C_
Condition: Unknown
Due 12 June 1997
Resolved 12 June 1997
Construction/Loadline
Issued 12 June 1997 Resolved
INSTALL HIGH WATER ALARM IN ENGINE ROOM.
Condition: Unknown
Due 12 June 1997
Resolved 12 June 1997
Engineering
Issued 12 June 1997 Resolved
DOUBLE CLAMP ALL RAW WATER HOSES. ALSO, ENSURE THAT HOSES CURRENTLY INSTALLED ARE CORRECT TYPE, i.e. METAL REINFORCED.
Condition: Unknown
Due 12 June 1997
Resolved 12 June 1997
Electrical
Issued 12 June 1997 Resolved
PROPERLY SECURE WITH METAL WRAPS ALL NEWLY INSTALLED WIRING IN ENGINE ROOM CURRENTLY HUNG WITH PLASTIC WIRE TIES.
Condition: Unknown
Due 12 June 1997
Resolved 12 June 1997
Engineering
Issued 12 June 1997 Resolved
LOCATE AND REPAIR LEAK IN FUEL TANK-HOSE CONNECTION AREA IN ENGINE ROOM.
Condition: Unknown
Due 12 June 1997
Resolved 12 June 1997
Lifesaving
Issued 12 June 1997 Resolved
REPLACE LINE ON RING BUOYS. LINE MUST BE AT LEASE 5/16" IN DIAMETER.
Condition: Unknown
Due 12 June 1997
Resolved 12 June 1997
Lifesaving
Issued 12 June 1997 Resolved
STENCIL VESSEL NAME ON STBD RING BUOY.
Condition: Unknown
Due 12 June 1997
Resolved 12 June 1997
Lifesaving
Issued 1 July 1993 Resolved
PROVIDE IMMERSION SUITS FOR ALL PERSONS ALLOWED PER COI AND 46 CFR 160.171.
Condition: Unknown
Due 8 July 1993
Resolved 19 August 1993
Deck/Cargo
Issued 1 July 1993 Resolved
MAKE AVAILABLE FOR EXAMINATION THE EXTERNAL CARGO TANK FRAMING AND ADJACENTSIDE/SHELL.
Condition: Unknown
Due 1 July 1993
Resolved 1 July 1993
Deck/Cargo
Issued 1 July 1993 Resolved
PROVIDE COPIES OF OIL TRANSFER PROCEDURES FOR REVIEW-VESSEL AND TANK TRUCK.
Condition: Unknown
Due 1 July 1993
Resolved 1 July 1993
Engineering
Issued 1 July 1993 Resolved
PROPERLY ALIGN PTO PULLY ON STARBOARD MAIN ENGINE.
Condition: Unknown
Due 10 August 1993
Resolved 16 August 1993
Unknown
Issued 1 July 1993 Resolved
PROPERLY TORQUE ALL FOUNDATION BOLTS ON BOTH MAIN ENGINES AND KNEE DRIVES.
Condition: Unknown
Due 10 August 1993
Resolved 16 August 1993
Electrical
Issued 1 July 1993 Resolved
ALL ELECTRICAL WIRING SHALL MEET 46 CFR 111.105-31 IN CARGO BLOCK ZONE. ALL ELECTRICAL POWERED WINCHES ARE IN THE CARGO BLOCK AREA. WINCHES SHALL NOT BE OPERATED DURING CARGO TRANSFERS.
Condition: Unknown
Due 1 July 1993
Resolved 1 July 1993
Deck/Cargo
Issued 1 July 1993 Resolved
REPAIR VALVE(DRAIN) ON CONTAINMENT-MAIN DECK STDB SIDE.
Condition: Unknown
Due 10 August 1993
Resolved 16 August 1993
Construction/Loadline
Issued 1 July 1993 Resolved
PROVIDE DOWN FLOODING CAPS ON ALL VOIDS AND WING TANKS.
Condition: Unknown
Due 1 July 1993
Resolved 1 July 1993
Deck/Cargo
Issued 1 July 1993 Resolved
PROVIDE OVERCURRENT PROTECTION ON ALL WINCH MOTOR CONDUCTORS PER 46 CFR 111.15-25.
Condition: Unknown
Due 1 July 1993
Resolved 1 July 1993
Engineering
Issued 1 July 1993 Resolved
PROVIDE LOSS OF COOLING WATER ALARM FOR THE MAIN ENGINE EXHAUSTS PER 46 CFR182.15-150(a)(5).
Condition: Unknown
Due 1 July 1993
Resolved 1 July 1993
Lifesaving
Issued 1 July 1993 Resolved
PROVIDE INFLATABLE LIFE RAFT PER 46 CFR 160.051 OR RESCUE BOAT PER 46 CFR 160.056 AS REQUIRED BY 46 CFR 33.05-30.
Condition: Unknown
Due 1 August 1993
Resolved 17 August 1993
Fire Fighting
Issued 1 July 1993 Resolved
SERVICE ALL SEMIPORTABLE AND PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 1 July 1993
Resolved 1 July 1993
Construction/Loadline
Issued 1 July 1993 Resolved
PAINT IN CONTRASTING COLOR THE BOW AND STERN, PORT AND STBD DRAFT MARKS.
Condition: Unknown
Due 1 July 1993
Resolved 1 July 1993
Electrical
Issued 1 July 1993 Resolved
PROPERLY BLOCK ALL BATTERIES IN TRAYS.
Condition: Unknown
Due 10 August 1993
Resolved 16 August 1993
Engineering
Issued 1 July 1993 Resolved
DOUBLE CLAMP ALL FLEXIBLE HOSES ON ALL RAW WATER LINES IN THE ENGINE ROOM.
Condition: Unknown
Due 10 August 1993
Resolved 16 August 1993
Deck/Cargo
Issued 9 July 1988 Resolved
PROVIDE AND INSTALL PROPER FLAME SCREENS ON CARGO TANKS NR'S 3, 4, 5, AND 6
Condition: Unknown
Due 9 July 1988
Resolved 9 July 1988
Unknown
Issued 13 May 1988 Resolved
CONDUCT FIRST REINSPECTION PRIOR TO PLACING VESSEL IN SERVICE AND NO LATER THAN 13JUNE88 TO THE SATISFACTION OF ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 13 May 1988
Resolved 13 May 1988
Deck/Cargo
Issued 10 July 1986 Resolved
HYDRO CARGO OIL TRANSFER LINES TO ONE AND A HALF WORKING PRESSURE AND LOG
Condition: Unknown
Due 10 July 1986
Resolved 10 July 1986
Fire Fighting
Issued 10 July 1986 Resolved
PROVIDE PROOF OF SERVICING OF ALL PORTABLE AND SEMI PORTABLE FIRE EXTINGUISHERS
Condition: Unknown
Due 10 July 1986
Resolved 10 July 1986
Construction/Loadline
Issued 10 July 1986 Resolved
DOUBLE CLAMP FLEXIBLE HOSE CONNECTING KEEL COOLERS
Condition: Unknown
Due 10 July 1986
Resolved 10 July 1986
Construction/Loadline
Issued 10 July 1986 Resolved
REPAIR LEAK IN PORT KEEL COOLER AT NEXT DRYDOCKING BUT NOT LATER THAN 31 DEC 86
Condition: Unknown
Due 10 July 1986
Resolved 10 July 1986
Fire Fighting
Issued 8 July 1985 Resolved
PROVIDE PROOF OF FIRE EXTINGUISER SERVICING.
Condition: Unknown
Due 8 July 1985
Resolved 8 July 1985
Lifesaving
Issued 8 July 1985 Resolved
ATTACH WATERLIGHT TO RING LIFE BUOY IAW 46 CFR 180.30-10.
Condition: Unknown
Due 8 July 1985
Resolved 8 July 1985
Deck/Cargo
Issued 8 July 1985 Resolved
PROVIDE SUFFICIENT ANCHOR LINE FOR VESSEL & MAKE UP SO AS TO BE READILY AVAILABLE.
Condition: Unknown
Due 8 July 1985
Resolved 8 July 1985
Lifesaving
Issued 8 July 1985 Resolved
PROVIDE 3 ADDITIONAL "INDATE" ORANGE SMOKE DISTRESS FLARES IAW 180.35.
Condition: Unknown
Due 8 July 1985
Resolved 8 July 1985

Casualty record · 1

14 October 2015Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 5775639
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.