KETIVIK is a 1976 tank ship. The Coast Guard has recorded 31 inspections since 1985, most recently in September 2025, along with 79 deficiencies and 1 casualty investigation in 2015.
Records from 1985 to 2025. Most recent: inspection, 11 September 2025.
- Built
- 1976
- Last inspected
- 11 September 2025
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 79 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2015
Identity
575101
48824
Flag
UNITED STATES
—
Maury page id
psix-48824
Inspections, by type
…with no type recorded5
Years with a record
23 calendar years (1985–2025)
The 31 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it19 - Regulatory (Subpart C or D), Gross Ton
13 - Regulatory (Subpart C or D), Net Ton
13 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 31
11 September 2025
Administrative Inspection · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8231787
14 October 2015
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5775639
20 January 2009
Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3397103
25 October 2006
Administrative Inspection · Deficiency Check · Annual Inspection · MARPOL Annex V Examination
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 2809501
7 October 2005
COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 2327998
2 August 2004
Annual Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 2153939
6 July 2004
In-Service Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 2123439
10 July 2003
Re-Inspection · Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1935529
7 August 2002
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1951135
22 July 2002
Annual Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1650473
19 July 2001
Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1376681
5 September 2000
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 169454
18 June 2000
COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 821022
21 June 1999
Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1365363
29 June 1998
COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1437471
31 December 1997
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 783775
12 June 1997
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1422979
11 July 1994
Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1176346
1 July 1993
COI Inspection · Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 843087
28 August 1992
Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1265182
27 August 1992
Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 954188
22 May 1992
Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1267686
3 July 1991
COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1001028
29 June 1990
Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 928371
8 July 1989
COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1208498
9 July 1988
Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1202751
13 May 1988
Hull Examination · Examination of Repairs · Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1195810
16 November 1987
Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1023712
7 July 1987
COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1011169
10 July 1986
Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 993355
8 July 1985
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 985473
Deficiency record · 79
Operations/Management › Drug and Alcohol Testing › Testing, Substances
Issued 25 October 2006
Resolved
Provide proof of drug testing program meets DOT standard.
Deck/Cargo › Cargo Stowage › General
Issued 25 October 2006
Resolved
Provide cargo gear certificate.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 25 October 2006
Resolved
Prove proper operation of stern light.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 25 October 2006
Resolved
Provide proof of benzene monitoring program
Pollution Prevention/Response › Prevention Equipment › Coamings
Issued 25 October 2006
Resolved
Relocate cargo vent vent inside of containment.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 25 October 2006
Resolved
Hydrostatically test nitrogen bottle for dry chemical fire extinguisher.
Construction/Loadline › Structures › Superstructure
Issued 25 October 2006
Resolved
Replace window glass in pilot house.
Construction/Loadline › Penetrations › Flange Pad
Issued 25 October 2006
Resolved
Replace cap on hydraulic tank with cap made of non-combustible material.
Electrical › Electrical Distribution System (service) › Conductor
Issued 25 October 2006
Resolved
Remove or place in junction box dead end wire in way of aft bulkhead.
Construction/Loadline › Penetrations › Valve Flange
Issued 25 October 2006
Resolved
Repair F/O shutoff for main diesel engines.
Fire Fighting › Fixed Fire Detection System › Detector/Call Point Grouping
Issued 25 October 2006
Resolved
Provide audible and visual alarm for fixed fire fighting in engine room.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 7 October 2005
Resolved
Provide proof of first aid/CPR cards for 50% of the crew.
Operations/Management › Drills/Instruction › Not Conducted
Issued 7 October 2005
Resolved
Log training and lifesaving equipment maintenance.
Lifesaving › Lifebuoys › Approval
Issued 7 October 2005
Resolved
Replace white life rings with orange.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 7 October 2005
Resolved
Prove proper operation of stern light.
Navigation › Collision/Grounding Avoidance › Radar
Issued 7 October 2005
Resolved
Prove proper operation of radar.
Fire Fighting › Ventilation Systems › Ducts
Issued 7 October 2005
Resolved
Provide securing devices for engine room ventilation.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 7 October 2005
Resolved
provide four pfd's.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 7 October 2005
Resolved
Repair port cable at bow.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 7 October 2005
Resolved
Prove proper operation of fixed fire fighting system.
Fire Fighting › Fire Bucket › Stenciling
Issued 7 October 2005
Resolved
Label firefighting buckets with vessel name.
Engineering › Fuel Oil Service System › Piping
Issued 7 October 2005
Resolved
Mark fuel shutoffs with 2 inch letters.
Fire Fighting › Ventilation Systems › Fans
Issued 7 October 2005
Resolved
make forced exhaust shutdown upon energizing fixed firefighting system.
Stability › Unintentional Flooding › General
Issued 7 October 2005
Resolved
Install pipe plug in valve in fwd bulkhead of engine room.
Operations/Management › Drills/Instruction › Safety Orientation
Issued 7 October 2005
Resolved
Provide emergancy instructions.
Navigation
Issued 18 June 2000
Resolved
MISSING VHF RADIO
Construction/Loadline
Issued 18 June 2000
Resolved
PROVE PROPER OPERATION BILGE ALARM.
Engineering
Issued 18 June 2000
Resolved
REPAIR WATER LEAK FROM BOTH SHAFT STUFFING BOXES.
Navigation
Issued 18 June 2000
Resolved
REPAIR/REPLACE P/S RUNNING LIGHTS.
Construction/Loadline
Issued 18 June 2000
Resolved
PROVIDE MIN 5GAL/MIN PARTABLE BILGE PUMP AT LEAST A 6' SUCTION HOSE.
Construction/Loadline
Issued 21 June 1999
Resolved
PROVE PROPER OPERATION OF MAIN BALLAST PUMP.
Lifesaving
Issued 21 June 1999
Resolved
PAINT FLARE BOX ORANGE: LABEL "DISTRESS SIGNALS".
Electrical
Issued 21 June 1999
Resolved
LABEL MAIN CIRCUIT PANEL IN WHEELHOUSE.
Deck/Cargo
Issued 21 June 1999
Resolved
MOUSE ALL STANDING RIGGING SCREW-PIN SHACKLES.
Navigation
Issued 21 June 1999
Resolved
REPLACE UNDERSIZED COTTER KEY WITH PROPER SIZE - PORT STEERING ARM.
Deck/Cargo
Issued 21 June 1999
Resolved
REPLACE UNDERSIZED TURNBUCKLE BOLT STARBOARD SIDE RAMP.
Construction/Loadline
Issued 21 June 1999
Resolved
PROVE PROPER OPERATION OF HIGH WATER ALARM.
Lifesaving
Issued 21 June 1999
Resolved
INSTALL RETRO-REFLECTIVE TAPE ON BOTH RING BUOYS - SPLICE LINE AROUND BODY OF RING - PUT PROPER NAME OF VESSEL ON STARBOARD SIDE RING BUOY.
Deck/Cargo
Issued 21 June 1999
Resolved
REPLACE PINCHED HEAD WIRE.
Lifesaving
Issued 12 June 1997
Resolved
POST "NO SMOKING" SIGNS ON FRONT EXTERIOR OF WHEELHOUSE.
Lifesaving
Issued 12 June 1997
Resolved
CONSPICUOSLY MARK CARGO PUMP SHUTDOWN ON MAIN DECK.
Construction/Loadline
Issued 12 June 1997
Resolved
MARK AND IDENTIFY ALL VALVES ON BILGE AND BALLASE SYSTEM.
Documentation
Issued 12 June 1997
Resolved
RENEW DOCUMENTATION. LAST DOCUMENTED IN 1994.
Engineering
Issued 12 June 1997
Resolved
INSTALL METAL PLUG VS. PLASTIC PLUG IN RACOR FUEL FILTER. ALSO REINSTALL METAL FLAME IMPINGEMENT BOWL.
Deck/Cargo
Issued 12 June 1997
Resolved
INSTALL A LEAK DETECTION SYSTEM IN VOID AREA AROUND FUEL (CARGO) TANK TO SHOW BOTH THE PRESENCE OF FUEL AND FLAMABLE VAPORS.
Deck/Cargo
Issued 12 June 1997
Resolved
REPLACE ALL ELECTRIC DECK WINCHES WITH EXPLOSION PROOF WINCH MOTORS OR HYDRAULIC WINCHES.
Fire Fighting
Issued 12 June 1997
Resolved
INSTALL FIXED FIRE EXTINGUISHING SYSTEM IN ENGINE ROOM.
Fire Fighting
Issued 12 June 1997
Resolved
SERVICE ALL PORTABLE AND SEMI-PORTABLE FIRE EXTINGUISHERS._x001C_
Construction/Loadline
Issued 12 June 1997
Resolved
INSTALL HIGH WATER ALARM IN ENGINE ROOM.
Engineering
Issued 12 June 1997
Resolved
DOUBLE CLAMP ALL RAW WATER HOSES. ALSO, ENSURE THAT HOSES CURRENTLY INSTALLED ARE CORRECT TYPE, i.e. METAL REINFORCED.
Electrical
Issued 12 June 1997
Resolved
PROPERLY SECURE WITH METAL WRAPS ALL NEWLY INSTALLED WIRING IN ENGINE ROOM CURRENTLY HUNG WITH PLASTIC WIRE TIES.
Engineering
Issued 12 June 1997
Resolved
LOCATE AND REPAIR LEAK IN FUEL TANK-HOSE CONNECTION AREA IN ENGINE ROOM.
Lifesaving
Issued 12 June 1997
Resolved
REPLACE LINE ON RING BUOYS. LINE MUST BE AT LEASE 5/16" IN DIAMETER.
Lifesaving
Issued 12 June 1997
Resolved
STENCIL VESSEL NAME ON STBD RING BUOY.
Lifesaving
Issued 1 July 1993
Resolved
PROVIDE IMMERSION SUITS FOR ALL PERSONS ALLOWED PER COI AND 46 CFR 160.171.
Deck/Cargo
Issued 1 July 1993
Resolved
MAKE AVAILABLE FOR EXAMINATION THE EXTERNAL CARGO TANK FRAMING AND ADJACENTSIDE/SHELL.
Deck/Cargo
Issued 1 July 1993
Resolved
PROVIDE COPIES OF OIL TRANSFER PROCEDURES FOR REVIEW-VESSEL AND TANK TRUCK.
Engineering
Issued 1 July 1993
Resolved
PROPERLY ALIGN PTO PULLY ON STARBOARD MAIN ENGINE.
Unknown
Issued 1 July 1993
Resolved
PROPERLY TORQUE ALL FOUNDATION BOLTS ON BOTH MAIN ENGINES AND KNEE DRIVES.
Electrical
Issued 1 July 1993
Resolved
ALL ELECTRICAL WIRING SHALL MEET 46 CFR 111.105-31 IN CARGO BLOCK ZONE. ALL ELECTRICAL POWERED WINCHES ARE IN THE CARGO BLOCK AREA. WINCHES SHALL NOT BE OPERATED DURING CARGO TRANSFERS.
Deck/Cargo
Issued 1 July 1993
Resolved
REPAIR VALVE(DRAIN) ON CONTAINMENT-MAIN DECK STDB SIDE.
Construction/Loadline
Issued 1 July 1993
Resolved
PROVIDE DOWN FLOODING CAPS ON ALL VOIDS AND WING TANKS.
Deck/Cargo
Issued 1 July 1993
Resolved
PROVIDE OVERCURRENT PROTECTION ON ALL WINCH MOTOR CONDUCTORS PER 46 CFR 111.15-25.
Engineering
Issued 1 July 1993
Resolved
PROVIDE LOSS OF COOLING WATER ALARM FOR THE MAIN ENGINE EXHAUSTS PER 46 CFR182.15-150(a)(5).
Lifesaving
Issued 1 July 1993
Resolved
PROVIDE INFLATABLE LIFE RAFT PER 46 CFR 160.051 OR RESCUE BOAT PER 46 CFR 160.056 AS REQUIRED BY 46 CFR 33.05-30.
Fire Fighting
Issued 1 July 1993
Resolved
SERVICE ALL SEMIPORTABLE AND PORTABLE FIRE EXTINGUISHERS.
Construction/Loadline
Issued 1 July 1993
Resolved
PAINT IN CONTRASTING COLOR THE BOW AND STERN, PORT AND STBD DRAFT MARKS.
Electrical
Issued 1 July 1993
Resolved
PROPERLY BLOCK ALL BATTERIES IN TRAYS.
Engineering
Issued 1 July 1993
Resolved
DOUBLE CLAMP ALL FLEXIBLE HOSES ON ALL RAW WATER LINES IN THE ENGINE ROOM.
Deck/Cargo
Issued 9 July 1988
Resolved
PROVIDE AND INSTALL PROPER FLAME SCREENS ON CARGO TANKS NR'S 3, 4, 5, AND 6
Unknown
Issued 13 May 1988
Resolved
CONDUCT FIRST REINSPECTION PRIOR TO PLACING VESSEL IN SERVICE AND NO LATER THAN 13JUNE88 TO THE SATISFACTION OF ATTENDING MARINE INSPECTOR.
Deck/Cargo
Issued 10 July 1986
Resolved
HYDRO CARGO OIL TRANSFER LINES TO ONE AND A HALF WORKING PRESSURE AND LOG
Fire Fighting
Issued 10 July 1986
Resolved
PROVIDE PROOF OF SERVICING OF ALL PORTABLE AND SEMI PORTABLE FIRE EXTINGUISHERS
Construction/Loadline
Issued 10 July 1986
Resolved
DOUBLE CLAMP FLEXIBLE HOSE CONNECTING KEEL COOLERS
Construction/Loadline
Issued 10 July 1986
Resolved
REPAIR LEAK IN PORT KEEL COOLER AT NEXT DRYDOCKING BUT NOT LATER THAN 31 DEC 86
Fire Fighting
Issued 8 July 1985
Resolved
PROVIDE PROOF OF FIRE EXTINGUISER SERVICING.
Lifesaving
Issued 8 July 1985
Resolved
ATTACH WATERLIGHT TO RING LIFE BUOY IAW 46 CFR 180.30-10.
Deck/Cargo
Issued 8 July 1985
Resolved
PROVIDE SUFFICIENT ANCHOR LINE FOR VESSEL & MAKE UP SO AS TO BE READILY AVAILABLE.
Lifesaving
Issued 8 July 1985
Resolved
PROVIDE 3 ADDITIONAL "INDATE" ORANGE SMOKE DISTRESS FLARES IAW 180.35.
Casualty record · 1
14 October 2015Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 5775639
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.