Records from 2012 to 2026. Most recent: inspection, 18 February 2026.
Inspection history · 25
18 February 2026
Deficiency Check · Vessel Attendance · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8312555
13 March 2025
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8093406
10 February 2025
DAPI Audit · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8077489
27 November 2024
Administrative Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8040829
15 April 2024
Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7895391
16 February 2024
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7866174
19 October 2023
Special · Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7811298
7 April 2023
Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7664587
21 February 2023
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7639515
10 January 2023
Drydock Exam · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7619552
18 February 2022
Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7398334
2 November 2021
Type not recorded
No type recorded · Station Panama City · USCG Heartland District (CGD-H) · Activity 7344395
3 February 2021
Deficiency Check · DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7135833
19 January 2021
Deficiency Check · Drydock Exam · Administrative Inspection · Hull Examination · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7127126
26 February 2020
DAPI Audit · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6909174
9 January 2019
Drydock Exam · Annual Inspection · Administrative Inspection · Internal Structural Exam · DAPI Audit · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6609077
14 November 2018
Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6580505
21 February 2018
Deficiency Check · DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6354325
6 December 2017
Internal Structural Exam · Examination of Repairs · Administrative Inspection · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6319850
27 November 2017
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6316375
10 April 2017
Deficiency Check · Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6117553
30 March 2017
Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6114231
27 February 2017
In-Service Inspection · Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6098447
23 February 2017
Administrative Inspection · Construction Oversight
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6093716
27 April 2016
Administrative Inspection · Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5860523
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 27 February 2025
Resolved
The following operational hazards to safety systems were identified and must be corrected:
1. Unable to take bilge suction from the center void.
2. The egress route in the machinery space needs to be properly stenciled EMERGENCY EXIT, KEEP CLEAR from both directions.
3. Reattach the life float paddles to the body of the life float.
4. Stencil both remote fuel shut-off valves.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 March 2025
Resolved 13 March 2025
Resolution: Corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 February 2025
Resolved
The following operational hazards to machinery and electrical systems were identified and must be corrected:
1. The STBD generator fuel filter is not equipped with a metal bowl or flame shield.
2. The electrical receptacle on the STBD/Forward side of the machinery space is compromised and needs to be replaced.
3. The battery box covers need to be properly secured and mounted.
4. The wires for the high water bilge alarm in the lazarette need to be properly secured.
5. Remove all excess materials from the machinery space.
6. The STBD generator overload protection device (breaker) is oversized (125A) and should not exceed 89.2 amps. Replaced with an appropriate sized breaker.
7. There are numerous unsafe practices, fire hazards, and other hazardous situations that must be corrected in the machinery space.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 March 2025
Resolved 13 March 2025
Resolution: Corrected.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 16 February 2024
Resolved
The vessel must have a VHF-DSC radio that is properly installed. The radio must have the MMSI programmed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 March 2024
Resolved 29 February 2024
Resolution: Corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 February 2024
Resolved
The lifejacket stowage location must be marked with size and quantity. The stowage doesn't have the quantity marked.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 March 2024
Resolved 29 February 2024
Resolution: Corrected.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 April 2023
Resolved
Coast Guard inspector received the manufacturer's specifications for the newly acquired generator and identified a 660 pound deletion of weight. Simplified Stability tests will be required anytime the addition or deletion of weight exceeds 500 pounds. In addition, anytime the center of gravity of the engine/generator that is being installed significantly differs from the engine being removed, a stability test will be required. Owners and Operators of Small Passenger Vessels must abide by these regulations if they plan to re-power their vessel. The vessel is given the deadline of 01JAN2024 to conduct a satisfactory Simplified Stability test.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 January 2024
Resolved 21 November 2023
Resolution: See Act# 7811298 for more details.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 21 February 2023
Resolved
Inspect bulkheads in accordance with 46 CFR 176.802. Fwd engine room blkhd is not watertight.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 March 2023
Resolved 28 February 2023
Resolution: Owner sealed opening in forwrd bulk head.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 February 2023
Resolved
Inspect for hazardous conditions in accordance with 46 CFR 176.830. Port generator is leaking oil excessively.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 March 2023
Resolved 28 February 2023
Resolution: Owner maintenanced gasket and seals on SSDG.Reduced oil seepage.
09 - Working and Living Conditions › 091 - Living Conditions › Cleanliness
Issued 21 February 2023
Resolved
Inspect vessel for sanitation in accordance with 46 CFR 176.818. Concession area sanitation was unsatisfactory.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 March 2023
Resolved 28 February 2023
Resolution: Owner cleaned concession stand area.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 February 2023
Resolved
Inspect vessel for hazardous conditions in accordance with 46 CFR 176.830. Overhead over stbd generator is coated in oil residue.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 March 2023
Resolved 28 February 2023
Resolution: Owner cleaned over head of SSDG.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 21 February 2023
Resolved
Inspect fire equipment in accordance with 46 CFR 176.810. Renew firehose.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 March 2023
Resolved 28 February 2023
Resolution: Owner renewed fire hose, tested all sat.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 21 February 2023
Resolved
Inspect weather deck structure in accordance with 46 CFR 176.802. Renew port window.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 March 2023
Resolved 28 February 2023
Resolution: Owner replaced port window.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 21 February 2023
Resolved
Inspect fire main in accordance with 46 CFR 176.810. Renew corroded fire main piping in engine room at next drydock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 January 2025
Resolved 13 March 2025
Resolution: Corrected.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 February 2022
Resolved
Replace port fire hose supply valve, valve is wasted.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 February 2022
Resolution: Attended vessel verified fire hose supply valve replaced.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 18 February 2022
Resolved
Replace or service stbd fire extinguisher main deck. Extinguisher was missing servicing tag.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 February 2022
Resolution: Attended vessel verified fire fighting equip was serviced.
09 - Working and Living Conditions › 091 - Living Conditions › Furnishings
Issued 18 February 2022
Resolved
Forward bench seat loose.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 February 2022
Resolution: Attended vessel verified seat properly attached.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 February 2022
Resolved
Center MDE F/O supply valve handle missing. Provide handle to allow valve to be closed.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 February 2022
Resolution: Verifed handle was installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 18 February 2022
Resolved
Center MDE J/W temp/alarm inop. Repair or replace and prove proper operation of temp/alarm for J/W.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 February 2022
Resolution: Verified J/W temp/alarm worked appropriately.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 February 2022
Resolved
Bilge piping shall be ferrous material for vital systems. Bilge piping elbows in the engine room and steering compartment were found wasted.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 February 2022
Resolution: Verified new installed and functioning bilge piping.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 February 2022
Resolved
Vessel required to provide visual and audible alarm to indicate a high water level. H/W alarm for steering compartment inop.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 February 2022
Resolution: Verified H/W alarm function for steering compartment.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 18 February 2022
Resolved
Engine room bilge found with excessive amount of oil. Clean and dispose of excessive accumulation of oil from Engine room bilge.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 February 2022
Resolution: Verified engine room bilge was clean.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 February 2022
Resolved
Port SSDG Salt water strainer loose.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 February 2022
Resolution: Verified SSDG salt water strainer was properly secured.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 18 February 2022
Resolved
Port SSDG electrical control module loose and unsupported. Attach control module to bracket for support.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 February 2022
Resolution: Verified control module was properly secured.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 February 2022
Resolved
Starboard generator salt water valve inoperable.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 February 2022
Resolution: Verified stbd gen salt water valve operated appropriately.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 February 2022
Resolved
Electrical equipment must be maintained to prevent fire. Generator windings are found with excess amounts of oil.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 February 2022
Resolution: Verified generator windings were effectively cleaned.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 February 2022
Resolved
Steering linkage found with loose clamp and interference with steering quadrant.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 February 2022
Resolution: Verified steering functioned appropriately.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 3 February 2021
Resolved
Missing Radio Safety Certificate. Provide proof of updated document.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 February 2021
Resolution: Provided proof of updated Radio Safety Certificate.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 February 2021
Resolved
Reduce quantity of power-strips on the Bridge and Galley.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 March 2021
Resolved 10 February 2021
Resolution: Vessel owner was able to show Inspectors the removal of power strips from the Bridge and Galley.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 3 February 2021
Resolved
Collision bulkhead valve in bilge inoperable. Reach Rod unsatisfactory provide proof of repair.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 February 2021
Resolution: Vessel owner demonstrated repair of Reach Rod repair.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 February 2021
Resolved
Ensure proper hardwiring of port-side Engine Room Battery Charger.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 March 2021
Resolved 10 February 2021
Resolution: Vessel owner was able show the corrected hardwiring of the port-side Engine Room Battery Charger.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 February 2021
Resolved
ESP Instillation unsatisfactory. Ensure proper wiring and installation.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 February 2021
Resolved 10 February 2021
Resolution: Owner removed ESP from vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 February 2021
Resolved
Repair vents of the port and starboard fuel tanks.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 February 2021
Resolved 10 February 2021
Resolution: Vessel owner showed Marine Inspectors the repaired port and starboard vents.
09 - Working and Living Conditions › 091 - Living Conditions › Galley, handlingroom (maintenance)
Issued 3 February 2021
Resolved
Provide a latch for the galley refrigerator.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 February 2021
Resolved 10 February 2021
Resolution: Vessel owner was able to provide latches for the refrigerator. Properly installed.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 3 February 2021
Resolved
Replace light fixtures on top deck of the vessel.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 February 2021
Resolved 10 February 2021
Resolution: Light fixtures replaced on top deck of the vessel.
09 - Working and Living Conditions › 091 - Living Conditions › Water, pipes, tanks
Issued 3 February 2021
Resolved
Fresh water service pump in Engine Room, not secured. Provide proof of correction.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 February 2021
Resolved 10 February 2021
Resolution: Fresh water pump in Engine Room properly secured.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 3 February 2021
Resolved
Replace life floats due to unserviceable conditions. Provide proof of newly acquired equipment.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 February 2021
Resolution: Vessel owner provided correspondence from Life-float company that conducted repairs are satisfactory.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 20 January 2021
Resolved
At Dry dock, observed three worklist items including repairing of the wood/hull area of the aft transducers sealer, anchor windlass generator belt guard/shiled being unsecured, and the fwd void bilge piping strainger being rusted away needign repair/replacement. Complete worklist according to regs prior to leaving dry dock.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 February 2021
Resolved 29 January 2021
Resolution: Observed satisfsactory repairs of all three worklist items.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 20 January 2021
Resolved
All machinery and equipment must be installed and maintained in such a manner to avoid causing fire, explosion, machinery failure, and personnell injury. Witnessed excessive oil, oil residue, and deisel in the bilge of E/R and on the two house generators. Repair/renew to clean and satisfactory safe condition.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 January 2021
Resolution: Observed satisfactory cleanup of the engien room and bilges and the generators/engines.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 24 January 2019
Resolved
Provide proof of EPIRB and NOAA registration.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 February 2019
Resolution: New EPIRB, Hydro and NOAA Registration.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 January 2019
Resolved
Repair or remove dead end wires on broken deck lights throughout.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 February 2019
Resolution: Corrected as instructed. Dead end wires removed and replaced broken deck lights.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 January 2019
Resolved
Double hose clamp the raw water suction hoses for both main diesel engines.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 February 2019
Resolution: Installed missing double hose clamps on R/W system.
Lifesaving › Lifefloat › Retroreflective Material
Issued 21 February 2018
Resolved
Clean and condition all Life Floats, Paint faded Life Float, also make repairs where needed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 March 2018
Resolved 1 March 2018
Resolution: Witnessed Life floats
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 21 February 2018
Resolved
New floating light for the life float.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 5 March 2018
Resolved 1 March 2018
Resolution: Witnessed Light, float test conducted.
Lifesaving › Lifefloat › Serviceable
Issued 21 February 2018
Resolved
Provide spacers for Life Float.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 March 2018
Resolved 1 March 2018
Resolution: Witnessed spacers
Lifesaving › Lifebuoys › Serviceable
Issued 21 February 2018
Resolved
Upper deck Life Ring Buoy recondition and paint, or prvide a new Buoy.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 March 2018
Resolved 1 March 2018
Resolution: Witnessed reconditioned LRB
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 21 February 2018
Resolved
Prvide mounting bracket for Engine Room FFE.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 March 2018
Resolved 1 March 2018
Resolution: Witnessed new Life Ring Bracket in ENG Room.
Engineering › Diesel Engine (propulsion-reduction gear) › Distributor (fuel injection)
Issued 21 February 2018
Resolved
Operational test of Center engine.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 March 2018
Resolved 1 March 2018
Resolution: Witnessed Center engine, new starter.
Stability › Intact Righting Energy › General
Issued 27 November 2017
Resolved
29March2017 Issued - The vessel re-powered its engines for a weight change of 423 lbs. The vessel is required to conduct a SST. Temporary ballast to compensate for the weight change will be allowed as only a temporary measure and will only be accepted till Nov 2017. **27Nov17 Extension request has been approved until 03Jan2018 at which time either an amendment to the vessel's current stability letter is approved by MSC or a new stability test conducted.**
Action required: 705 - Other - as specified
Due 31 January 2018
Resolved 21 February 2018
Resolution: Vessel installed permanant ballast
Construction/Loadline › Hull › Bottom Plating
Issued 10 April 2017
Resolved
Steering gear compartment needs gauging report.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 April 2017
Resolved 5 May 2017
Resolution: Gaging report provided.
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 10 April 2017
Resolved
Provide lights for life jacket
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 12 April 2017
Resolved 12 April 2017
Resolution: Lights were provided
Electrical › Electric Generation Source (service) › Grounding Conductor
Issued 10 April 2017
Resolved
Louver in electrical box in engine room.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 12 April 2017
Resolved 5 May 2017
Resolution: Witnessed
Stability › Intact Righting Energy › General
Issued 30 March 2017
Resolved
Vessel conducted repower that resulted in weight change and will require new SST.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 March 2017
Resolved 30 March 2017
Fire Fighting › Fire Pumps › Gland Sealing
Issued 27 April 2016
Resolved
Repair seal on fire pump
Action required: 705 - Other - as specified
Due 12 May 2016
Resolved 2 May 2016
Resolution: Vessel repaired seal.
Lifesaving › Lifebuoys › Quantity
Issued 27 April 2016
Resolved
Repair/Replace 2 identified ring lifebuoys (upper deck)
Action required: 705 - Other - as specified
Due 12 May 2016
Resolved 2 May 2016
Resolution: Vessel replaced ring buoys.
Lifesaving › Lifefloat › Serviceable
Issued 27 April 2016
Resolved
Repair / Replace 2 identified lifefloats 1 painter and 1 light line.
Action required: 705 - Other - as specified
Due 21 May 2016
Resolved 2 May 2016
Resolution: Vessel replaced floats and painter and line.
Communications › Radio Communications › VHF Radiotelephone
Issued 27 April 2016
Resolved
Install VHF radio with DSC function.
Action required: 705 - Other - as specified
Due 21 May 2016
Resolved 2 May 2016
Resolution: Vessel provided radio with DSC