Records from 1985 to 1992. Most recent: inspection, 9 April 1992.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 14
9 April 1992
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 948215
20 June 1991
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1224185
16 May 1991
COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1231786
5 June 1990
Hull Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1241098
18 May 1989
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1340552
16 December 1988
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1210217
7 November 1988
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1204711
25 May 1988
COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 889812
7 July 1987
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1014906
23 April 1987
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1011749
15 July 1986
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1300658
31 January 1986
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 996778
27 September 1985
Credit Drydock
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 990559
25 June 1985
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 984137
Engineering
Issued 16 May 1991
Resolved
LABEL THE EMERGENCY FUEL SHUT-OFF VALVES. INCLUDE DIRECTION TO CLOSE ARROWS.
Condition: Unknown
Due 16 May 1991
Resolved 16 May 1991
Engineering
Issued 16 May 1991
Resolved
PROVE THE OPERATION OF BOTH EMERGENCY FUEL SHUT-OFF VALVES (CURRENTLY THE REACH ROD LINKAGE IS FROZEN).
Condition: Unknown
Due 16 May 1991
Resolved 16 May 1991
Lifesaving
Issued 16 May 1991
Resolved
REPLACE THE OUTDATED BATTERY IN THE EPERB.
Condition: Unknown
Due 16 May 1991
Resolved 16 May 1991
Documentation
Issued 16 May 1991
Resolved
POST AN OIL POLLUTION WARNING PLACARD BY THE BILGE PUMP SWITCH.
Condition: Unknown
Due 16 May 1991
Resolved 16 May 1991
Engineering
Issued 16 May 1991
Resolved
INSTALL BOWL PROTECTORS (HEAT SHIELDS) OVER THE PLASTIC BOWLS ON BOTH FUEL FILTERS.
Condition: Unknown
Due 16 May 1991
Resolved 16 May 1991
Fire Fighting
Issued 25 May 1988
Resolved
SERVICE OR RENEW FIRE EXTINGUISHERS.
Condition: Unknown
Due 25 May 1988
Resolved 25 May 1988
Documentation
Issued 25 May 1988
Resolved
POST EMERGENCY CHECKLIST.
Condition: Unknown
Due 25 May 1988
Resolved 25 May 1988
Lifesaving
Issued 25 May 1988
Resolved
PROVIDE 1 ADDITIONAL TYPE I ADULT PERSONAL FLOATATION DEVICE. UNTIL PROVIDED, PASSENGER TOTALS RESTRICTED TO 19.
Condition: Unknown
Due 25 May 1988
Resolved 25 May 1988
Unknown
Issued 7 July 1987
Resolved
PROVIDE 3 ADDITIONAL ORANGE SMOKE FLARES.
Condition: Unknown
Due 7 July 1987
Resolved 7 July 1987
Unknown
Issued 7 July 1987
Resolved
REPAIR AND DEMONSTRATE PROPER OPERATION OF THE STERN LIGHT. UNTIL THIS ITEM IS COMPLETED, VESSEL IS RESTRICTED TO DAYLIGHT OPERATION ONLY.
Condition: Unknown
Due 7 July 1987
Resolved 7 July 1987
Unknown
Issued 7 July 1987
Resolved
INSTALL A WEAK LINK SUITABLE FOR THE LIFE FLOAT AND BUOYANT APPARATUS STOWED IN TANDAM, OR SEPARATE THE APPARATUS AND PROVIDE ONE ADDITIONAL WEAK LINK.
Condition: Unknown
Due 7 July 1987
Resolved 7 July 1987
Unknown
Issued 7 July 1987
Resolved
MAKE PERMANENT REPAIR TO THE PORT ENGINE ELECTRICAL STARTING SYSTEM AND DEMONSTRATE PROPER OPERATION.
Condition: Unknown
Due 7 July 1987
Resolved 7 July 1987
Unknown
Issued 7 July 1987
Resolved
MAKE PERMANENT REPAIRS TO THE EMERGENCY FUEL SHUT-OFF VALVES FOR THE PORT AND STARBOARD FUEL TANKS AND DEMONSTRATE PROPER OPERATION. UNTIL THIS ITEMIS COMPLETED, NO PASSENGERS MAY BE CARRIED.
Condition: Unknown
Due 7 July 1987
Resolved 7 July 1987