JEREMY R is a 1976 passenger vessel (inspected). The Coast Guard has recorded 23 inspections since 1982, most recently in July 2025, along with 28 deficiencies and 1 operational control.

Records from 1982 to 2025. Most recent: inspection, 7 July 2025.

Built
1976
Last inspected
7 July 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDJ5601
Flag
UNITED STATES
367789450
Maury page id
psix-48827

Inspections, by type

…with no type recorded3
Years with a record 16 calendar years (1982–2025)
The 23 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)41.2 ft × 13.8 ft × 6.5 ft
Registered tonnagegross 28 / net 19
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderALUMINUM SPECIALTY WELD · HOUMA, LA, UNITED STATES · built 1976
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portROCKPORT, TX
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 16 February 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it28 - Regulatory (Subpart C or D), Gross Ton
19 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDJ5601MMSI 367789450 · active · compulsorily equipped · granted 17 May 2017, expires 17 May 2027
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 23

7 July 2025 COI Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 8178076
3 December 2024 Deficiency Check · Simplified Stability Test · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8042645
3 October 2024 Deficiency Check · Annual Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8013687
23 February 2024 Deficiency Check · Examination of Repairs · In-Service Inspection · Drydock Exam · Plan Review "T" Boat
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7869210
18 July 2023 Deficiency Check · Annual Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7746143
26 May 2022 Annual Inspection · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7459730
23 May 2022 Administrative Inspection · Drydock Exam · Hull Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7457231
2 September 2021 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 7303296
20 July 2020 COI Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7000532
2 July 2020 Hull Examination · Internal Structural Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6993866
2 October 2019 Administrative Inspection · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6827777
26 September 2018 Deficiency Check · Annual Inspection · In-Service Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6549476
17 April 2018 Internal Structural Exam · In-Service Inspection · Hull Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6393639
4 May 2017 DAPI Audit · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6137115
15 June 2016 Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5908415
26 May 2016 Hull Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5887166
2 October 2014 Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4997623
10 June 2014 Drydock Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4885191
22 May 2012 Internal Structural Exam · Drydock Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4308295
8 August 2011 Annual Inspection · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4109128
27 February 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1301761
8 August 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1277645
22 February 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 970279

Deficiency record · 28

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 December 2024 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Starboard engine was not fully operational. Repair to the satisfaction of the attending Marine Inspector. 46 CFR 182.200(a)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 December 2024
Resolution: Had a tech to come out and make repairs to the starboard engine.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 12 December 2024 Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. The crew accommodation space and the engine room bilge alarm was alarming on the same circuit. Each bilge high level alarm must alert on separate circuit. Repair to the satisfaction of the attending Marine Inspector. 46 CFR 182.530(c)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 December 2024
Resolution: Repaired bilge high level alarm for the engine room and crew accommodation compartment.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 12 December 2024 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date:Charts of large enough scale to make safe navigation possible. Vessel was unable to provide verification that the most up to date charts was installed. Repair to the satisfaction of the attending Marine Inspector.46 CFR 184.420(a)(1)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 December 2024
Resolution: Installed most up to date charts.
09 - Working and Living Conditions › 092 - Working Conditions › Anchoring devices
Issued 12 December 2024 Resolved
A vessel must be fitted with ground tackle and mooring lines necessary for the vessel to be safely anchored or moored. The ground tackle and mooring lines provided must be satisfactory for the size of the vessel, the waters on which the vessel operates, subject to the approval of the cognizant OCMI. The anchor provided onboard was heavily corroded and was not in suitable condition for vessels operation. Repair to the satisfaction of the attending Marine Inspector. 46 CFR 184.300
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 December 2024
Resolution: Replaced anchor onboard.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 12 December 2024 Resolved
Whenever damage or deterioration to hull plating or structural members that may affect the seaworthiness of a vessel is discovered or suspected, the cognizant OCMI may conduct an internal structural examination in any affected space and to effect permanent repairs. Found 03 cracked welds in forepeak on the starboard longitudinal frame and 02 cracked welds on the port and starboard transverse forward frame. 46 CFR 176.600(2)(d)
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 December 2024
Resolution: Repaired the cracked welds found in the engine room and forepeak.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 12 December 2024 Resolved
A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable, and made watertight. The cable penetration in the engine room had visible light coming through. Repair to the satisfaction of the attending Marine Inspector. 46 CFR 183.210(3)(b)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 12 December 2024
Resolution: Repaired the cable pentration in the engine room.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 12 December 2024 Resolved
Each battery used in an item of lifesaving equipment, except inflatable survival craft equipment, must be replaced during the annual inspection if the expiration date of the battery has passed. The expiration date of the battery may be marked on the battery or the owner or managing operator may have a record of the expiration date from the manufacturer of a battery marked with a serial number. Found 02 expired water lights onboard. Repair to the satisfaction of the attending Marine Inspector. 46 CFR 185.726(d)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 12 December 2024
Resolution: Replaced 02 waterlight batteries.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 23 February 2024 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull, protection against fire, means of escape in case of a sudden unexpected casualty, guards and rails in hazardous places, ventilation of enclosed spaces, and necessary facilities for passengers and crew. MIs observed numerous insets in hull plating on vessel side shell, located in the vicinity of the port and starboard mid ships. Enact repairs to the satisfaction of the Marine Inspector. Provide a repair plan to [email withheld].
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 8 May 2024
Resolved 11 July 2024
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 23 February 2024 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. When repairs are made during an emergency, the owner, managing operator, or master shall notify the OCMI as soon as practicable after such repairs or alternations are made. Repairs or alterations that affect the safety of the vessel include, but are not limited to: replacement, repair, or refastening of deck or hull planking, plating, and structural members; repair of plate or frame cracks; damage repair or replacement, other than replacement in kind, of electrical wiring, fuel lines, tanks, boilers and other pressure vessels, and steering, propulsion and power supply systems; alterations affecting stability; and repair or alteration of lifesaving, fire detecting, or fire extinguishing equipment. Vessel is required to conduct a stability test due to a swap of both the port and starboard engines and associated piping.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 February 2025
Resolution: Satisfactory completion of SST.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 25 July 2023 Resolved
At least the required minimum intensity is maintained at all angles from 5 degrees above to 5 degrees below the horizontal. Canopy built on deck of vessel obstructs the stern light and does not give it the full 5 degrees above the horizon sector. Vessel is restricted to daytime operations until stern light is corrected to the satisfaction of the attending marine inspector.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 August 2023
Resolved 26 July 2023
Resolution: Company send photo of navigation light that was relocated to the stern of the canopy.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 July 2023 Resolved
Each ring life buoy on a vessel must be approved in accordance with § 160.050 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.150. Ring life buoy did not have a USCG approval number attached to it. Correct to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2023
Resolved 26 July 2023
Resolution: Company sent photo of replaced Ring Buoy.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 June 2022 Resolved
Each lifejacket must be marked with Type I retroreflective material approved in 46 CFR 164.018. Lifejackets were found to have faded or wasted retroreflective tape on multiple lifejackets. Vessel representative had extra SOLAS retroreflective tape and instructed crew member to apply new tape. Cleared according to the satisfaction of the Marine Inspector. 46 CFR 185.604(h)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 13 June 2022
Resolved 13 June 2022
Resolution: Vessel rep instructed crew to re-tape all lifejackets with wasted tape.
Engineering › Bilge Water Management System › Not Operational
Issued 15 June 2016 Resolved
Bilge alarms not functional. Repair to the satisfaction of attending Marine Inspector and prior to vessel movement.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 22 June 2016
Resolved 22 June 2016
Resolution: Bilge alarms tested satisfactory.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 15 June 2016 Resolved
Fire fighting servicing report not on vessel. Provide a copy of report prior to vessel movement.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 22 June 2016
Resolved 22 June 2016
Resolution: Firefighting certificate current and on board vessel.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 15 June 2016 Resolved
Alcohol test strips not on board. Provide test strips prior to sailing more than 2 hours from shore.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 June 2016
Resolved 22 June 2016
Resolution: Verified alcohol test strips are on board vessel.
Construction/Loadline › Hull › Transverse Frame
Issued 26 May 2016 Resolved
Strut frames in lazerette need to be replaced. 1 channel weld on starboard and 2 on port side
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 8 June 2016
Resolution: Repaired to satisfaction of attending MI.
Construction/Loadline › Hull › Longitudinal Frame
Issued 26 May 2016 Resolved
Port side engine mount (inboard) has 5 cracked welds. Grind out and repair welds.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 8 June 2016
Resolution: Repair made to the satisfaction of the attending Coast Guard Marine Inspector.
Construction/Loadline › Hull › Longitudinal Frame
Issued 26 May 2016 Resolved
Found below deck of cabin compartment: 5 cracked welds on frames, port side 1 cracked weld on frame, starboard side. Grind out and replace welds.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 8 June 2016
Resolution: Repair made to the satisfaction of the attending Coast Guard Marine Inspector.
Electrical › Electric Generation Source (service) › Panelboard
Issued 2 October 2014 Resolved
Vessel is missing AMP, Cycles and Volts gauges.
Condition: Placed in Improper Service
Due 7 October 2014
Resolved 2 October 2014
Resolution: Vessel rep placed new gauges at generator location. All Sat.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 8 August 2011 Resolved
Prove inspection and maintenance of fixed pre-engineered fire extinguishing system. CG-835 No-Sail was given for this item.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 October 2011
Resolution: Rep provided servicing report for pre-engineered fire extinguishing system in E/R.
Stability › Watertight Integrity › General
Issued 8 August 2011 Resolved
Provide a shutoff valve for each keel cooler as near to the shell as practicable.
Due 22 August 2011
Resolved 4 October 2011
Resolution: Shut off valves installed for Generator keel cooler penetrations. Main Engine keel cooler penetrations were hard piped to above the damage waterline.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 8 August 2011 Resolved
Provide a floating water light for each lifefloat. Item is to be completed prior to night operation.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 4 October 2011
Resolution: Water lights provided for each lifefloat.
Electrical › Electric Generation Source (service) › Circuit Breaker
Issued 8 August 2011 Resolved
Secure breaker switch on generator.
Condition: Damaged By Earlier Event
Due 22 August 2011
Resolved 17 August 2011
Resolution: Breaker switch was secured via two bolts.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 8 August 2011 Resolved
Provide a belt guard for generator.
Condition: Improper Installation
Due 22 August 2011
Resolved 17 August 2011
Resolution: Belt/machinery guard was intalled on the generator''s water pump.
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 August 2011 Resolved
Install metallic clamps every 24" in the engine room and #2 void.
Condition: Improper Installation
Due 22 August 2011
Resolved 4 October 2011
Resolution: Metallic clamps installed in E/R and #2 void.
Stability › Watertight Integrity › General
Issued 8 August 2011 Resolved
Plug hole from lazarette to engine room.
Action required: 705 - Other - as specified
Due 22 August 2011
Resolved 17 August 2011
Resolution: New plug was intalled on the aft, engine room bulkhead - just outboard of the C.L. on the starboard side.
Personnel › Training › Fire Fighting Basic
Issued 8 August 2011 Resolved
Conduct drills in presence of Coast Guard Marine Inspector. CG-835 No-Sail was given for this item.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 October 2011
Resolution: MOB and Fire drill completed satisfactorily.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 8 August 2011 Resolved
Provide double hose clamps on both sides of flexible hose on both main exhausts.
Condition: Improper Installation
Due 22 August 2011
Resolved 17 August 2011
Resolution: Double hose clamps were installed on both main exhausts.