← All vessels
INDUSTRIAL AMA
INDUSTRIAL AMA is a 1998 freight ship. The Coast Guard has recorded 101 inspections since 1998, most recently in September 2026, along with 66 deficiencies and 19 operational controls.
Records from 1998 to 2026. Most recent: inspection, 6 September 2026.
- Built
- 1998
- Last inspected
- 6 September 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Inspections
- 101
- Deficiencies
- 66 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9193812 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
V2DD8
488344
Flag
ANTIGUA AND BARBUDA
—
Maury page id
psix-488344
Inspections, by type
…with no type recorded30
Years with a record
23 calendar years (1998–2026)
The 101 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it6066 - Dead Weight, Metric Ton
2189 - Regulatory (Subpart C or D), Net Ton
4246 - Regulatory (Subpart C or D), Gross Ton
2189 - Convention (Subpart B), Net Ton
8813 - Displacement, Metric Ton
4246 - Convention (Subpart B), Gross Ton
2189 - Regulatory (Subpart C or D), Net Ton
4246 - Regulatory (Subpart C or D), Gross Ton
2189 - Convention (Subpart B), Net Ton
8813 - Displacement, Metric Ton
4246 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 101
6 September 2026
COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8484643
22 July 2026
COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8443997
9 February 2026
Administrative Inspection · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8307934
23 January 2026
COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8300550
30 December 2025
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8295039
20 December 2025
COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8285952
24 November 2025
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8273590
21 October 2025
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8256651
21 April 2025
PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8115973
27 December 2024
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8051313
15 November 2024
PSC A · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8035368
19 July 2024
Deficiency Check · PSC A
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7961933
18 June 2024
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7937638
15 May 2024
PSC A
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7912719
4 May 2024
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7906413
16 February 2024
PSC A
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7866483
8 February 2024
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7863046
12 January 2024
ISM Exam · Ballast Water Examination · PSC A · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7848622
28 June 2023
Administrative Inspection · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7725432
8 September 2022
PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7554057
11 February 2022
PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7394648
6 February 2022
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7391449
4 January 2022
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7375432
1 January 2022
Deficiency Check · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7374393
15 November 2021
PSC B · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7350973
10 November 2021
Deficiency Check · PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7346390
27 March 2021
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7164034
27 March 2021
COE-Offshore
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7164044
25 February 2021
PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7146016
18 July 2020
PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7009243
13 April 2020
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6938993
18 March 2020
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6928690
18 March 2020
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6928695
18 March 2020
COE-Offshore
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7014180
15 February 2020
PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6909613
3 January 2020
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6882494
29 November 2019
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6864559
25 September 2019
COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6820814
2 July 2019
COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6733459
28 June 2019
COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6728685
6 June 2019
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6700154
6 June 2019
Explosive Handling Operation-Commercial
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6709291
19 April 2019
Explosive Handling Operation-Commercial
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6667555
11 April 2019
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6660479
1 April 2019
COE-Dockside · COE-Administrative
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6651268
22 February 2019
Explosive Handling Operation-Commercial
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6630313
18 December 2018
COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6599620
11 November 2018
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6578779
13 October 2018
COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6561418
10 October 2018
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6558370
10 September 2018
COE-Dockside
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6536737
3 August 2018
In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6500216
19 June 2018
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6450351
26 March 2018
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6378528
26 November 2017
Administrative Inspection · COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6312783
22 September 2017
COE-Dockside
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6272378
22 August 2017
COE-Dockside
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6248071
17 July 2017
COE-Dockside
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6211659
13 July 2017
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6208257
9 June 2017
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6170475
9 June 2017
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6170801
28 April 2017
COE-Dockside
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6134427
15 February 2017
COE-Dockside
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6088680
27 November 2016
Deficiency Check · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6047929
17 November 2016
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6034004
30 July 2012
PII Safety Exam · COE-Offshore · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4392388
19 May 2012
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4312109
19 May 2012
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4315517
11 January 2012
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4222721
11 November 2010
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3887979
25 September 2010
COE-Dockside
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3856776
26 April 2009
COE-Administrative · Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3461080
14 April 2009
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3452670
26 February 2009
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3422820
17 July 2008
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3270549
28 May 2008
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3220008
25 May 2008
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3216419
21 November 2007
Ballast Water Examination · ISPS II Exam · PI Safety Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3102379
7 October 2007
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3074907
7 October 2007
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3084509
18 October 2006
Ballast Water Examination · PII Safety Exam · ISPS III Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2798343
10 October 2006
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2797837
29 April 2006
ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2636532
2 September 2005
PII Safety Exam · ISPS I Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2481985
13 January 2005
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2274232
12 January 2005
Random ISPS/MTSA/PSC · ISPS I Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2273752
11 January 2005
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2272495
21 September 2004
ISPS II Exam
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2201350
17 February 2004
Administrative Inspection
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2007794
3 February 2004
Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1999420
22 October 2001
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 294886
30 July 2001
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 114680
10 March 2001
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 287937
4 January 2001
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 285943
1 February 2000
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 274252
4 January 2000
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 211265
4 January 2000
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 754193
14 December 1999
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 435714
23 November 1999
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 99598
23 November 1999
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 434838
5 December 1998
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 424136
Deficiency record · 66
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 15 November 2024
Resolved
Stairways and lift trunks which penetrate more than a singledeck shall be surrounded by at least "A-0" class divisions and be protected by self-closing doors at all levels.
PSCO observed unauthorized modification to class A fire boundary on deck 3. Ship's crew ran internet cable from passageway into ladder well. Additionally, PSCO observed hole in class A fire door leading from engineer's workshop to escape trunk.
74 SOLAS (97) II-2/46.1
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 15 November 2024
Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for imediate use.
PSCO observed fire and safety equipment locker locked with a pad-lock. during fire drill ships crew could not find the key for over five minutes.
74 SOLAS (20) II-2/14.2.1.2
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 15 November 2024
Resolved
Doors required to be self-closing shall not be fitted with hold-back hooks.
PSCO observed hold-back on self-closing fire door leading from passageway to main ladder well on deck 1. Additionally, door gasket was loose preventing door from closing.
74 SOLAS (97) II-2/47.2
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 15 November 2024
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or the persons on board.
PSCO observed temporary repair on ballast water piping below ballast pump number 2 leaking at approximately 30 drops per minute.
74 SOLAS (20) I/11(a)
99 - Other › N/A - No Subsystem › Other (SOLAS operational)
Issued 19 July 2024
Resolved
A ship when in a port of another contracting government is subject to control by officers duly authorized by such government concerning operational requirements in respect of the safety of ships, when there are clear grounds for believing that the master or crew are not familiar with essential shipboard procedures relating to the safety of ships.
PSCO observe 2 unsatisfactory fire drills. During both drills when asked to perform a check of their equipment members were lacking a radio, and also were not on the correct channel. During Both drills members were observed removing their gloves to use their radios, flashlights, and to check the pressure of their SCBA. The lifeline attached to the fire team was made of combustible material in both drills the proper boundaries were not set.
SOALS XI-1/4.1
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 19 July 2024
Resolved
By the first scheduled dry docking after 1 January 2010 fixed carbon dioxide fire extinguishing systems for the protection of machinery spaces on ships constructed before 1 July 2002 shall comply with the provisions of paragraph 2.2.2 of chapter five of the fire safety systems code;
PSCO observed the fixed CO2 system controls activated the release of CO2 gas prior to opening the main valve in which the gas will be directed.
SOLAS II-2/ 10.4.1.5
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Resources and personnel
Issued 19 July 2024
Resolved
The company and ship shall comply with the requirements of the international safety management code for the purpose of this regulation the requirements of the code shall be treated as mandatory. The company should establish procedures to ensure the new personnel and personnel transfer to new assignments related to the safety and protection of the environment are given proper familiarization with their duties.
PSCO Observed multiple personnel with security duties on board the vessel were unaware of the proper baggage screening procedures at all security levels.
ISM 6.3
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 May 2024
Resolved
Where cables are installed in hazardous areas introduce the risk of fire or explosion in the event of an electtical fault in some areas, special precautions against such risks shall be taken to the satisfaction of the Administration.
PSCO observed exposed electrical wiring on a junction box inside the paint locker located at the entry door.
74SOLAS(04)/II-1/45.5.4
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 May 2024
Resolved
Electrical installations shall be such that the safety of passengers, crew and ship from electrical hazards will be ensured.
PSCO observed crew accomodation light fixture cover missing, exposing light bulbs and wires.
74SOLAS(04) II-1/40.1.3
14 - Pollution Prevention › 147 - Anti-Fouling › Other (AFS)
Issued 16 February 2024
Resolved
THE SURVEY SHALL BE SUCH AS TO ENSURE THAT THE SHIP'S ANTI-FOULING SYSTEM FULLY COMPLIES WITH THIS CONVENTION. PSCO OBSERVED EXCESSIVE ALGAE GROWTH ON THE SHIP'S HULL
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 17 January 2024
Resolved
Any required fixed fire detection and firm alarm system with manually operated call points shall be capable of immediate operation at all times.
PSCO observed smoe detection system for cargo holds were turned off.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 17 January 2024
Resolved
Hydrolic power operated steering gear shall be provided with a fixed storage tank having sufficient capacity to recharge at least one power actuating system including the reservoir.
PSCO observed hydrolic oil storage tank containing approximately 60 liters of fluid. Each pump has 100 liter capacity and the reservoir an additional 20 liters.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 January 2024
Resolved
The condition of the ship and it's equipment shall be maintained to torm with the provisions on the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board.
PSCO observed ballast water pump valve tied into the open position with a shoe lace bypassing the system.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 12 January 2024
Resolved
The company shall establish procedures to ensure the ship is maintained in accordance with relevant rules and regulations. In meeting these the company shall ensure inspections are held at appropriate intervals and non-conformities are reported and corrected. The mechanical and operational nature of the deficiencies noted below provide objective evidence of a serious failure of implementation of ISM code. An external audit report with focus on readiness and testing of emergency, lifesaving, and fire fighting equipment satisfactory to the OCMI must be submitted prior to clearing of this deficiency.
74 SOLAS (20) IX/3.1 ISM Code 10.2
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 12 January 2024
Resolved
Any required fixed fire detection and fire alarms system with manually operated call points shall be capable of immediate operation at all times.
PSCO observed fire detection system panel on bridge indicates zone 6 as empty and repeater panel in ECR indicates zone 8 as empty. Crew was unsure which zone is open. SMS test reports indicate crew is only testing zones 1 – 7.
74 SOLAS (97) II-2/13.1.1
11 - Life Saving Appliances › N/A - No Subsystem › Stowage of rescue boats
Issued 12 January 2024
Resolved
Rescue boats shall be stowed in a state of continuous readiness for launching in not more than 5 minutes.
PSCO observed that it took approximately 15 minutes to start the rescue boat.
74 SOLAS (97) III/14.1
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 January 2024
Resolved
Hydraulic power operated steering gear shall be provided with a low-level alarm for each hydraulic fluid reservoir to give the earliest practicable indication of hydraulic fluid leakage.
PSCO observed inoperable low hydraulic level alarm additionally hydraulic fluid reservoir was empty.
Hydraulic power operated steering gear shall be provided with a low-level alarm for each hydraulic fluid reservoir to give the earliest practicable indication of hydraulic fluid leakage.
PSCO observed inoperable low hydraulic level alarm additionally hydraulic fluid reservoir was empty.
Hydraulic power operated steering gear shall be provided with a low-level alarm for each hydraulic fluid reservoir to give the earliest practicable indication of hydraulic fluid leakage.
PSCO observed inoperable low hydraulic level alarm additionally hydraulic fluid reservoir was empty.
74 SOLAS (04) II-1/29.12.2
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 12 January 2024
Resolved
An immersion suit of an appropriate size shall be provided for every person assigned to crew the rescue boat.
PSCO observed immersion suits of inadequate size for chief engineer and electrician.
74 SOLAS (97) III/7.3
10 - Safety of Navigation › N/A - No Subsystem › Gyro compass
Issued 12 January 2024
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board.
PSCO observed gyro-compass repeater with 60 degree deviation on port bridge wing conning station.
74 SOLAS (20) I/II
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 January 2024
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board.
PSCO observed broken air receiving gauge for pneumatic secondary starting system for emergency generator.
PSCO observed cooling water leak on sea water cooling piping between pump and condensers.
74 SOLAS (20) I/11
12 - Dangerous Goods › N/A - No Subsystem › Dangerous goods / harmful substances in pack. form
Issued 12 January 2024
Resolved
Irrelevant markings, labels, placards, orange panels, signs, and marine pollutant marks shall be removed prior to packing.
PSCO observed numerous placarded containers on deck, However vessels crew indicated that they were empty.
IMDG 7.5.2.6
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 12 January 2024
Resolved
The machinery, boilers, and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board,...
PSCO Observed excessive accumulation of oil in the vicinity of the hydraulic tank and stern tube tank located in the aft portion of the engine room.
74 SOLAS (04) II-1/26.1
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 12 January 2024
Resolved
Each emergency generating set arranged to be automatically started shall be equipped with starting devices with a stored energy capability of at least three consecutive starts.
PSCO observed emergency generator primary and secondary starting device fail to start. Ships crew was able to start after an hour of troubleshooting.
74 SOLAS (04) II-1/44.2
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 12 January 2024
Resolved
Any required fixed fire detection and fire alarm system with manually operated call points shall be capable of immediate operation at all times.
PSCO observed smoke detector in the engine control room was inoperable. Additionally, multiple manually operated call points located in accommodation passageways were duct taped and unable to be tested per manufacturer's instructions.
74 SOLAS (97) II-2/13.1.1
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 January 2024
Resolved
Before the ship leaves port and at all times during voyage, all life-saving appliances shall be in working order and ready for immediate use.
PSCO observed one life buoy cracked.
14 - Pollution Prevention › 148 - Ballast Water › Ballast Water Management System (BMWS)
Issued 12 January 2024
Resolved
The master, owner, operator, agent, or person in charge or a vessel equipped with ballast tanks that operates in the waters of the U.S. must employ one of the following BWM methods.
The Master, Owner, Operator, Agent, or person in charge of the vessel subject to this subpart must properly maintain the BWMS in accordance with all manufacture specifications.
The vessel's BWTS manual indicates that ballast is to be treated both on uptake and discharge the systems log is missing discharge events indicated in the vessels hand written log. Additionally, the system log recorded multiple errors and alarms regarding the UV light units, high difference pressure, and missing feeback on valves, indicating the system may not be working properly.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 15 November 2021
Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: Fire detection and fire alarm systems.
Two smoke alarms in the engine control room failed to activate when tested.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 15 November 2021
Resolved
A ship when in a port or offshore terminal of another party is subject to inspection by officers duly authorized by such party concerning operational requirements under this annex, where there are clear grounds for believing that the master or crew are not familiar with essential shipboard procedures relating to the prevention of pollution by oil. (MARPOL 1/11.1)
Ship's personnel could not demonstrate to PSCO's how to perform an operational test of oil filtering equipment. Vessel is equipped with oil filtering equipment complying with Resolution MEPC.60(33).
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Resources and personnel
Issued 15 November 2021
Resolved
The Company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the Company. (10.1) The Company should ensure that all personnel involved in the company's Safety Management System have an adequate understanding of relevant rules, regulations, codes, and guidelines. (6.4)
74 SOLAS (20) IX/3.1, ISM Part A/6.4, ISM Part A/10.1
Vessel could not provide PSCO's with any SMS procedures regarding testing and maintenance of the ship's oil filtering equipment.
(6.4) As referenced in Deficiency #2, vessel's personnel failed to act in accordance with its ships procedures.
Require internal audit focusing on testing and maintenance of oil filtering equipment, and security within 90 days.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 10 November 2021
Resolved
07126 – Oil Accumulation in Engine Room - The purpose of this regulation is to limit the fire growth potential in every space of the ship. Means of control for flammable liquids in the space shall be provided. PSCO observed approximately 200 gallons of oil in the bilge under the main engine. – 74 SOLAS (04) II-2/5.1.1 – 17ac
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 10 November 2021
Resolved
11129 – Operational Readiness of Lifesaving Appliances - All life-saving appliances prescribed in this part shall where exposed to sunlight, be resistant to deterioration. In addition, be fitted with retro-reflected material where it will assist in detection and in accordance with the recommendations of the organization. PSCO observed fasteners on windshield and windows of lifeboat corroded and wasted, multiple cracks around fastener holes. Reflective tape in the front of the lifeboat was no longer reflective. – 74 SOLAS (97) III/30.2.5 and 30.2.7 – 17ac
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 November 2021
Resolved
07110 – Fire fighting Equipment and Appliances - Nozzles shall be of an approved dual-purpose type, incorporating a shutoff. PSCO discovered 6 out of 8 fire nozzles on deck were seized. – 74 SOLAS (04) II-2/10.2.3.3.4 – 17ac
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 10 November 2021
Resolved
02199 – Other (Structural Condition) - The strength of the deckhouses used for accommodation of the crew shall be to the satisfaction of the administration. PSCO discovered that the entire superstructure was supported above the deck by steel beams and associated securing devices, the steel beams and associated devices are wasted and failing. – ILL Annex I/25.1 – 50bc
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 10 November 2021
Resolved
09298 – Working Conditions (Accident Prevention) - The steering gear compartments shall be provided with handrails and gratings or other nonslip surfaces to ensure suitable working conditions in the event of hydraulic fluid leakage. PSCO observed no non-slip matting or grating in front of steering gear machinery controls. – 74 SOLAS (04) II-1/45.2 – 40ac
14 - Pollution Prevention › 148 - Ballast Water › Ballast Water Management System (BMWS)
Issued 10 November 2021
Resolved
CG006 – Ballast Water Management System – AMA, of keel laid date 01DEC1997 and ballast water capacity of 2450 m3, is past its compliance date per the implementation schedule in 33 CFR 151.2035(b). Vessel’s current ballast water management method is exchange and discharge, which is not authorized. Vessel has no BWTS installed. Vessel is not authorized to discharge untreated ballast into US waters. This deficiency will not be cleared until CG examiners receive documentation that the vessel has installed a BWTS, has decided to use only public water from the US public water system, or has updated its ballast water management plan to state that the vessel’s ballast water management method in US waters is no discharge. – 33 CFR 151.2035 – 15c
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 25 February 2021
Resolved
Where necessary, oil fuel and lubricating oil pipelines shall be screened or otherwise suitably protected to avoid as far as practicable oil spray or oil leakages on to hot surfaces on into machinery air intakes. The number of joints in such piping system shall be kept to a minimum and, where practicable, be collected and arrangements provided for on alarm to be given.
PSCOs observed excessive oil on steering gear, main engine, and bilge pockets.
74 SOLAS (97 Cons)II-2/15.5.1
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 25 February 2021
Resolved
Doors required to be self-closing shall not be fitted with hold-back hooks. However, hold-back arrangements fitted with release devices of the fail safe type may be utilized.
PSCOs observed hold-back on A-60 self-closing fire boundry door.
74 SOLAS (97 Cons)II-2/47.2
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 6 June 2019
Resolved
A food ration shall be kept in airtight packaging. PSCO observed 10 of the required 15 foor ration packages with air inside.
SOLAS 74(97 Cons) III / 13.1.4 LSA (2017) CH. IV 4.4.8.12
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 6 June 2019
Resolved
Oil fuel and lubricating oil pipelines shall be suitably protected to avoid as far as practicable oil spray or oil leaks onto hot surfaces.
PSCO observed accumulations of oil under main engine, reduction gear, and shaft, creating a fire hazard.
SOLAS 74 (97 CONS) II-2 / 15.5.1
10 - Safety of Navigation › N/A - No Subsystem › Bridge operation
Issued 3 August 2018
Resolved
THE DESIGN AND ARRANGEMENT OF NAVIGATIONAL SYSTEMS AND EQUIPMENT ON THE BRIDGE AND BRIDGE PROCEDURES SHALL BE TAKEN WITH AIM OF PREVENTING OR MINIMIZING ANY CONDITIONS OR DISTRACTIONS ON THE BRIDGE WITCH MAY CAUSE FATIGUE OR INTERFERE WITH THE VIGILANCE OF THE BRIDGE TEAM AND THE PILOT. PSCOS RECEIVED REPORT FROM GALVESTON PILOTS ONBOARD ABOUT EXPERIENCING EXCESSIVE HEAT CONDITIONS ON THE BRIDGE. UPON ATTENDING VESSEL, PSCOS WITNESSED TEMPERATURES EXCEEDING 30C ON THE BRIDGE AT 2300 LOCAL TIME. IN ADDITION PSCOS OBSERVED RECORDED TEMPERATURES ON BOARD EXCEEDING 35C ON THE BRIDGE AND EXCEEDING 41C IN THE BRIDGE TEAM'S REST AND ACCOMODATION SPACES. SOLAS 14 CH V/ 15.6
09 - Working and Living Conditions › 091 - Living Conditions › Ventilation (Accommodation)
Issued 3 August 2018
Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATION TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEDD TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ONBOARD. PSCOS FOUND THAT THE VESSELS AIR CONDITIONING UNIT HAS BEEN INOPERABLE FOR A PERIOD EXCEEDING ONE AND A HALF MONTHS. VESSEL MASTER AND CREW HAD RECORDED TEMPERATURES INSIDE THE NAVIGATION BRIDGE AND ACCOMODATION SPACES EXCEEDING 35C AND UP TO 41C, CREATING A POTENTIALLY UNSAFE ENVIRONMENT DUE TO EXCESSIVE HEAT. SOLAS 14 CH I/11(A)
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 26 March 2018
Resolved
1420 - The associated piping systems and fittings shall be of a design and construction adequate fot the service for which they are intended. Pipe located on starboard bottom level of engine room is leaking excessive oil to the extent that a bucket need ed to be placed to collect it. Bucket was half filled with oil. 74SOLAS(2004CONS) II-1/26.1
Operations/Management › Ballast Water Managment › Mandatory Practices
Issued 26 March 2018
Resolved
0940- In order to discharge ballast water in the waters of the United States, the vessel must use a ballast water management system (BWMS) type approved by the US Coast Guard, use an alternative management system (AMS) or use ballast with water from US public water system (PWS) according to the schedule in paragraph (b) of this section. The existing vessel keel laid in 16DEC97 with a ballast capacity of 2450m3, dry-docked in 11JAN18 has passed its compliance date and has not installed a BWMS or AMS, prior to discharging untreated ballast water in the waters of the United States, the vessel must comply with one of the approved ballast water management methods listed in 33CFR151.2035(a). 33CFR151.2035(a)
Lifesaving › Inflatable Liferafts › Markings
Issued 26 March 2018
Resolved
0699 - Posters or signs shall be provided on or in the vicinity of survival craft and their launching controls and shall illustrate the purpose of controls and the procedures for operating the appliance and give relevant instructions or warnings. Signs for liferaft launching procedures are worn and weathered to the point o being indecipherable and need to be replaced. 74SOLAS (1997CONS.)II-2/20.1
Fire Fighting › Structural - A Class Divisions › Doors
Issued 26 March 2018
Resolved
0915 - In all ships, general arrangements shall be permanently exhibited for the guidance of the ship's officers showing clearly the various fire sections enclosed by "A" and "B" class divisions and means of access to different compartments and decks. Ship's fire control plan does not properly show class "A" boundaries and self closing doors between various compartments and decks. Fire control plans next to gangway and outside galley do not match. 74SOLAS (1997CONS.) II-2/20.1
Operations/Management › Ballast Water Managment › Mandatory Practices
Issued 26 March 2018
Resolved
2550 - The company should establish procedures to ensure that the ship is maintained in conformity with the provisiion of the relevant rules and regulations. The vessel is past its compliance date (01JAN2018) and did not install a ballast water treatment system during drydock (11JAN2018-05FEB2018) 74SOLAS (2014CONS.) IX/3.1 ISM CODE 10.1
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 March 2018
Resolved
The motor vessel INDUSTRIAL AMA owner/operator provided false information in regard to untreated ballast water discharge both into the waters of the Port of Houston, TX. and the Exclusive Economic Zone of the United States.
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 17 November 2016
Resolved
A FIREMANS OUTFIT SHALL CONSISTS OF PROTECTIVE CLOTHING OF MATERIAL TO PROTECT THE SKIN FROM HEAT RADIATING FROM THE FIRE AND FROM BURNS AND SCALDING BY STEAM. ONE OF VESSELS FIREMANS OUTFITS DOES NOT CONTAIN A FACE HOOD OR SHIELD.74 SOLAS (1997 CONS.ED.)CH II-2 REG. 17.1.1.1
Lifesaving › Immersion Suits › Not on Board
Issued 17 November 2016
Resolved
IF A SHIP HAS ANY WATCH OR WORKSTATIONS WHICH ARE LOCATED REMOTELY FROM THE PLACE OR PLACES WHERE IMMERSIONS SUITS ARE NORMALLY STOWED,ADDITIONAL IMMERSIONS SUITS SHALL BE PROVIDED AT THESE LOCATIONS FOR THE NUMBER OF PERSONS NORMALLY ON WATCH OR WORKING AT THOSE LOCATIONS AT ANYTIME. VESSEL DOES NOT HAVE ANY IMMERSION SUITS ON THE BRIDGE OR ENGINE ROOM. 74 SOLAS (2014 CONS.ED.) CH. III,REG.32.3.3
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 17 November 2016
Resolved
ALL WASTE RECEPTACLES SHALL BE CONSTRUCTED OF NON-COMBUSTIBLE MATERIALS WITH NO OPENINGS IN THE SIDES OR BOTTOMS. ENGINE ROOM HAS MULTIPLE BAGS FILLED WITH OILY RAGS AND PLASTIC CONTAINERS FILLED WITH OILY WATER MIXTURE.74 SOLAS (1997 CONS. ED.)CH. II-2 REG.18.5
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 30 July 2012
Resolved
Efficient guardrails or bulwarks shall be fitted to all exposed parts of the freeboard and superstructure decks. Guard rail port side amidships, top rail wasted. ICLL 66 I/25(2)
Fire Fighting › Firemans Outfit › Lifeline
Issued 28 May 2008
Resolved
Fireman’s lifeline was not of the fire resistant type. Vessel is to replace life line with fire resistant type, have class submit a report attesting the life line is approved.
Electrical › Electric Generation Source (service) › Power Requirement
Issued 21 November 2007
Resolved
Classification Society to determine if vessel meets Solas Chap II-1 Reg 41. Generator sets are independant and appear not to meet 1.1.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 21 November 2007
Resolved
Bilge eduction system for aft steering is capable of discharging hydraulic fluid directly to sea via eductor and firemain, bypassing OWS.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 21 November 2007
Resolved
Disicator element on OWS is indicating "white" and is expired. There are no spares onboard.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 21 November 2007
Resolved
OWS was found to have two soft patches on associated suction piping.
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (hydraulic)
Issued 7 October 2007
Resolved
Prior to departure the vessel is required to submit documentation from the certificate issuing authority attesting to the cause of the loss of propulsion, corrective action and the ability of the vessel to safely transit through the Port of Houston.
Construction/Loadline › Hull › Hull Plating
Issued 7 October 2007
Resolved
Vessel is required to complete a damage survey and underwater hull assessment prior to shifting and conducting cargo operations.
Engineering › Fuel Oil Storage/Transfer System › Manifold
Issued 2 September 2005
Resolved
Fuel manifold behind Main Diesel Engine leaking
Fire Fighting › Means of Escape › Blocked
Issued 2 September 2005
Resolved
Emergency escape trunk from lower Engine Room obstructed by drain hose.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 2 September 2005
Resolved
Fire door in engine room not fully self-closing
Engineering › Steering Gear System
Issued 3 February 2004
Resolved
Steering compartment does not have nonslip surface or handrails. Provide with suitable arrangements to the satisfaction of the certificate issuing authority.
Navigation
Issued 4 January 2001
Resolved
ECHO DEPTH SOUNDER HAS NO RECORDER. SYSTEM IS DIGITAL WITH A TWENTY FOUR HOUR MEMORY THAT HAS TO BE MANNUALLY SET. THERE IS NO WAY TO RETRIEVE THE RECORDINGS WITHOUT A PRINTER THAT WAS NEVER INSTALLED. VESSEL MUST_x001C_ PROVIDE A PRINTER FOR THE SYSTEM PRIOR TO 04 FEB 01. POC [name withheld]
Navigation
Issued 4 January 2001
Resolved
EMERGENCY STEERING DIAGRAM AND INSTRUCTIONS WERE NOT POSTED ON THE BRIDGE. REQUIRED TO HAVE POSTED NEXT US PORT
Navigation
Issued 14 December 1999
Resolved
Required CFR's not onboard. Provide invoice IAW 33CFR164.33.
Navigation
Issued 14 December 1999
Resolved
Pre-arrival/departure test not logged. Correct IAW 33CFR164.25
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.