MAURY USCG vessel records Sign in
← All vessels

ANA ENID III

ANA ENID III is a 1974 passenger vessel (inspected). The Coast Guard has recorded 42 inspections since 1984, most recently in July 2003, along with 91 deficiencies.

Records from 1984 to 2003. Most recent: inspection, 9 July 2003.

Built
1974
Last inspected
9 July 2003
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WZB7076
Flag
UNITED STATES
—
Maury page id
psix-48842

Inspections, by type

…with no type recorded4
Years with a record 20 calendar years (1984–2003)
The 42 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 23 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it19 - Regulatory (Subpart C or D), Gross Ton
16 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WTR2694MMSI not assigned · expired · compulsorily equipped · granted 28 January 1997, cancelled 21 April 2007
WZB7076MMSI not assigned · expired · compulsorily equipped · granted 6 April 1994, cancelled 30 May 2004
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 42

9 July 2003 Administrative Inspection
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1852755
9 October 2002 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1688485
25 June 2002 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1639618
2 October 2001 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 664411
28 July 2001 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 28637
11 April 2001 Deficiency Check · Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1373429
16 February 2001 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1376469
7 July 2000 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 820774
23 February 2000 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1046475
8 December 1999 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 812547
2 September 1999 Examination of Repairs
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1391099
21 January 1999 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1378578
19 August 1998 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1445382
25 June 1998 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1409943
30 January 1997 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1460052
7 November 1996 Hull Examination · Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1460923
1 February 1996 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1363481
27 April 1995 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1446197
19 April 1995 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1165722
7 March 1995 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1463161
24 February 1994 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1459862
8 June 1993 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1376987
3 March 1993 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1438030
9 March 1992 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 954128
12 February 1992 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1316817
23 December 1991 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 962357
27 April 1991 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 998510
8 March 1991 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1220201
30 March 1990 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 927971
9 March 1990 COI Inspection · Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 908674
21 April 1989 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 889836
12 April 1989 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 897120
16 March 1989 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1207338
9 June 1988 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 889575
17 March 1988 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1044132
19 March 1987 Hull Examination · COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1017753
13 June 1986 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1305905
3 December 1985 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1294279
13 November 1985 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 999681
23 September 1985 Credit Drydock
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 999679
10 May 1985 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 980493
4 April 1984 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1322713

Deficiency record · 91

Documentation › Certificates/Documents
Issued 25 June 2002 Resolved
Provide and post stability letter.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 October 2002
Resolution: Verified by DC1
Documentation › Certificates/Documents
Issued 25 June 2002 Resolved
Post Certificate of Inspection.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 October 2002
Resolution: Verified by DC1
Documentation › Certificates/Documents
Issued 25 June 2002 Resolved
Post small Passenger Vessel Decal.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 October 2002
Resolution: Verified by DC1
Fire Fighting
Issued 25 June 2002 Resolved
Provide annual service of fixed fire extinguisher.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 October 2002
Resolution: Verified by DC1
Navigation › Collision/Grounding Avoidance
Issued 25 June 2002 Resolved
Secure navigation white lights on roof. LEGACY COMPONENT DESC: Navigation Lights
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 October 2002
Resolution: Verified by DC1
Electrical › Electrical Distribution System (service)
Issued 25 June 2002 Resolved
Remove all obsolete electrical wires. LEGACY COMPONENT DESC: Wiring
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 October 2002
Resolution: Verified by DC1
Electrical › Electrical Distribution System (service)
Issued 25 June 2002 Resolved
Secure all electrical wires with metal supports every 24 inches apart. LEGACY COMPONENT DESC: Wiring
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 October 2002
Resolution: Verified by DC1
Lifesaving › Lifejacket/PFD (Type II)
Issued 25 June 2002 Resolved
Provide lifejacket placard.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 October 2002
Resolution: Verified by DC1
Lifesaving › Hand Flares
Issued 25 June 2002 Resolved
Provide waterproof container for flares and label container with "distress signals". LEGACY COMPONENT DESC: Storage
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 October 2002
Resolution: Verified by DC1
Fire Fighting › Fire Hoses
Issued 25 June 2002 Resolved
Provide water house for fire pump. LEGACY COMPONENT DESC: Condition
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 October 2002
Resolution: Verified by DC1
Fire Fighting
Issued 25 June 2002 Resolved
Provide fire buckets attached to a line.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 July 2002
Resolution: Vessel is not required to have fire buckets as per 46CFR181.610.
Lifesaving › Lifebuoys
Issued 25 June 2002 Resolved
Provide corrosion resistante clip to waterlight. LEGACY COMPONENT DESC: Self-igniting Lights
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 October 2002
Resolution: Verified by DC1
Documentation › Logs/Records
Issued 25 June 2002 Resolved
Log crewmembers training. LEGACY COMPONENT DESC: Logbook (official)
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 October 2002
Resolution: Verified by DC1
Navigation › Piloting/Steering
Issued 25 June 2002 Resolved
Secure helm to pilot house.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 9 October 2002
Resolution: Verified by DC1
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 25 June 2002 Resolved
Seal engine compartment to deck and bulkhead aspart of the fixed fighting system.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 October 2002
Resolution: Verified by DC1
Electrical › Electrical Distribution System (service)
Issued 25 June 2002 Resolved
Label all fuses to indicate zones/areas protected. LEGACY COMPONENT DESC: Fuse
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 October 2002
Resolution: Verified by DC1
Electrical › Electrical Distribution System (service)
Issued 25 June 2002 Resolved
Install locking mechanism to fuses storage space to keep unathorized access. LEGACY COMPONENT DESC: Junction Box
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 October 2002
Resolution: Verified by DC1
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 25 June 2002 Resolved
Replace 1 B-1and 1 B-II portable fire extinguishers. LEGACY COMPONENT DESC: Condition
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 October 2002
Resolution: Verified by DC1
Electrical › Electrical Distribution System (service)
Issued 25 June 2002 Resolved
Provide electrical ground to fuel tanks to a common ground. LEGACY COMPONENT DESC: Grounding Conductor
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 October 2002
Resolution: Verified by DC1
Engineering
Issued 11 April 2001 Resolved
Vessel to properly replace engine water coolant line on starboard side engine. To be completed prior to next vessel operation.
Condition: Unknown
Due 23 April 2001
Resolved 3 May 2001
Electrical
Issued 16 February 2001 Resolved
Properly connect or remove all loose wires in the egine compartment.
Condition: Unknown
Due 16 February 2001
Resolved 16 February 2001
Engineering
Issued 16 February 2001 Resolved
Prperly install both air blowers in egine room.
Condition: Unknown
Due 16 February 2001
Resolved 16 February 2001
Construction/Loadline
Issued 16 February 2001 Resolved
Properly seal forward / aft bulkheads in engine compartment.
Condition: Unknown
Due 16 February 2001
Resolved 16 February 2001
Engineering
Issued 16 February 2001 Resolved
Properly connect starboard side emergency fuel shut off handle.
Condition: Unknown
Due 16 February 2001
Resolved 16 February 2001
Engineering
Issued 16 February 2001 Resolved
Properly install two loose hose clamps on the starboard side engine. (Raw water cooling system)
Condition: Unknown
Due 16 February 2001
Resolved 16 February 2001
Navigation
Issued 16 February 2001 Resolved
Replace broken ground cable located adjacent to starboard side rudder post at steering compartment.
Condition: Unknown
Due 16 February 2001
Resolved 16 February 2001
Construction/Loadline
Issued 23 February 2000 Resolved
SATISFACTORY DEMONSTRATE MEANS OF DEWATERING THE FOREPEAK
Condition: Unknown
Due 23 February 2000
Resolved 23 February 2000
Fire Fighting
Issued 23 February 2000 Resolved
POST WRITTEN PROCEDURES REGARDING USE OF RECENTLY INSTALLED FIXED FIRE SYSTEM.
Condition: Unknown
Due 23 February 2000
Resolved 23 February 2000
Navigation
Issued 21 January 1999 Resolved
REPLACE CORRODED STEERING ARM BOLT UNDER LOCATED UNDER STEERING WHEEL
Condition: Unknown
Due 21 January 1999
Resolved 21 January 1999
Navigation
Issued 21 January 1999 Resolved
RE-ATTACH GROUND CABLE IWO RUDDER POST
Condition: Unknown
Due 21 January 1999
Resolved 21 January 1999
Lifesaving
Issued 21 January 1999 Resolved
SECURE ALL HOSE CONNECTIONS WITH DOUBLE CLAMPS
Condition: Unknown
Due 21 January 1999
Resolved 21 January 1999
Navigation
Issued 21 January 1999 Resolved
SECURE STEERING PIPE
Condition: Unknown
Due 21 January 1999
Resolved 21 January 1999
Navigation
Issued 21 January 1999 Resolved
RE-SECURE BOTH RUDDER POSTS
Condition: Unknown
Due 21 January 1999
Resolved 21 January 1999
Electrical
Issued 25 June 1998 Resolved
MARK ELECTRICAL CIRCIUT PANEL DIRECTORY WITH AMPERAGE / FUSE RATINGS PRIOR TO CARRYING PASSENGERS BUT NO LATER THAN 27 JUN 98.
Condition: Unknown
Due 27 June 1998
Resolved 31 August 1998
Documentation
Issued 25 June 1998 Resolved
PROVIDE PROOF OF DRUG TESTING FOR NEW EMPLOYEE, MARCOS A. VELEZ PRIOR TO CARRYING PASSENGERS BUT NLT 27 JUN 98.
Condition: Unknown
Due 27 June 1998
Resolved 31 August 1998
Construction/Loadline
Issued 25 June 1998 Resolved
MAKE TEMPORARY REPAIRS TO SOFT WOOD IN WAY OF ENGINE COMPARTMENT, AFT STARBOARD SIDE HULL PRIOR TO CARRYING PASSENGERS BUT NO LATER THAN 27 JUN 98.
Condition: Unknown
Due 27 June 1998
Resolved 31 August 1998
Construction/Loadline
Issued 25 June 1998 Resolved
RENEW WASTED KEEL BOLTS IN ENGINE COMPARTMENT AND FORWARTD FUEL TANK COMPARTMENT PRIOR TO CARRYING PASSENGERS BUT NLT 27 JUN 98.
Condition: Unknown
Due 27 June 1998
Resolved 31 August 1998
Construction/Loadline
Issued 7 November 1996 Resolved
REPLACE ALL WASTED SACRIFICAL ANODES.
Condition: Unknown
Due 26 November 1996
Resolved 27 November 1996
Engineering
Issued 7 November 1996 Resolved
PROVIDE PROPER BREATHER CAP FOR STARBOARD MAIN ENGINE TRANSMISSION.
Condition: Unknown
Due 26 November 1996
Resolved 27 November 1996
Construction/Loadline
Issued 7 November 1996 Resolved
RENEW ALL ROTTED/WASTED MAIN DECK AREAS ON PORT & STARBOARD SIDES IN WAY OFMAIN COMPARTMENT ADJACENT TO TRANSVERSE FRAMES AND HULL.
Condition: Unknown
Due 26 November 1996
Resolved 27 November 1996
Engineering
Issued 7 November 1996 Resolved
REPOSITION PORT SIDE MAIN ENGINE HORIZONTAL EXHAUST HOSE, TO ALLOW AND NOT INTERFERE WITH PLACEMENT OF BATTERY BOX COVER.
Condition: Unknown
Due 26 November 1996
Resolved 27 November 1996
Electrical
Issued 7 November 1996 Resolved
LOCATE AND INSTALL COVER ON MAIN DIESEL ENGINE STARTING BATTERY BOX.
Condition: Unknown
Due 26 November 1996
Resolved 27 November 1996
Electrical
Issued 7 November 1996 Resolved
PROVIDE ADEQUATE SOLDERED BATTERY CABLE TERMINAL CONNECTIONS FOR MAIN ENGINE STARTING BATTERIES.
Condition: Unknown
Due 26 November 1996
Resolved 27 November 1996
Engineering
Issued 7 November 1996 Resolved
REPAIR FUEL TANK SHUT OFF VALVE HANDWHEELS AND MAKE PERMANMENT ATTACHMENT TO FUEL TANK SHUT OFF VALVE REACH RODS.
Condition: Unknown
Due 26 November 1996
Resolved 27 November 1996
Construction/Loadline
Issued 7 November 1996 Resolved
REPAIR CRACKED CENTERLINE KEEL FLOOR FRAME IN WAY OF MAIN COMPARTMENT (2ND FRAME AFT OF FORWARD BULKHEAD) .
Condition: Unknown
Due 26 November 1996
Resolved 27 November 1996
Accommodation/Occupational Safety
Issued 7 November 1996 Resolved
REPAIR TUBULAR METAL HAND RAIL WHERE DISCONNECTED FROM STANCHION ON STARBOARD SIDE, AFT AREA.
Condition: Unknown
Due 26 November 1996
Resolved 27 November 1996
Construction/Loadline
Issued 7 November 1996 Resolved
REPLACE ROTTED DECK BENEATH SEATS LOCATED AT CENTERLINE IN AFT SEATING AREA.
Condition: Unknown
Due 26 November 1996
Resolved 27 November 1996
Accommodation/Occupational Safety
Issued 7 November 1996 Resolved
REPLACE WASTED CANOPY SUPPORT BRACKETS ON 2ND PORT SIDE SUPPORT AND 1ST STARBOARD SIDE SUPPORT.
Condition: Unknown
Due 26 November 1996
Resolved 27 November 1996
Construction/Loadline
Issued 7 November 1996 Resolved
REPAIR PORT & STARBOARD SIDE MECHCANIAL BLOWERS IN WAY OF AFT ENGINE COMPARTMENT.
Condition: Unknown
Due 26 November 1996
Resolved 27 November 1996
Lifesaving
Issued 7 November 1996 Resolved
REFASTEN PORT SIDE INBOARD OVERHEAD PFD STOWAGE SUPPORT TO CANOPY FRAMING IN AFT AREA.
Condition: Unknown
Due 26 November 1996
Resolved 27 November 1996
Engineering
Issued 7 March 1995 Resolved
Install remote reach rods to operate fuel shutoff valves so that operation of same is accomplished from outside fuel tank compartment without gaining access into the compartment.
Condition: Unknown
Due 30 April 1995
Resolved 28 April 1995
Construction/Loadline
Issued 7 March 1995 Resolved
Double clamp all through hull fittings at sea valve connections and at engine engine connection.
Condition: Unknown
Due 8 March 1995
Resolved 8 March 1995
Construction/Loadline
Issued 7 March 1995 Resolved
1. Replace below deck beam at 1st frame in aft engine compartment._x001C_ 2. Replace below deck beam at forward most frame in engine compartment._x001C_ 3. Remove surface rot from bottom frame at 1st frame between stbd engine and stbd hull in engine compartment.
Condition: Unknown
Due 8 March 1995
Resolved 8 March 1995
Construction/Loadline
Issued 7 March 1995 Resolved
Clean strainers and present for inspection.
Condition: Unknown
Due 8 March 1995
Resolved 8 March 1995
Engineering
Issued 7 March 1995 Resolved
Relocate fuel shutoff valves so that they are connected at fuel tanks.
Condition: Unknown
Due 7 April 1995
Resolved 20 April 1995
Documentation
Issued 24 February 1994 Resolved
Provide preemployment and random chemical testing program in accordance with Title 46 C.F.R. Part 16.
Condition: Unknown
Due 24 February 1994
Resolved 24 February 1994
Lifesaving
Issued 24 February 1994 Resolved
Install proper retroreflective material as required on life jeckets prior to carriage of passengers
Condition: Unknown
Due 24 February 1994
Resolved 13 April 1994
Fire Fighting
Issued 24 February 1994 Resolved
Provide properly serviced BII portable fire extinguisher prior to the carriage of passengers.
Condition: Unknown
Due 24 February 1994
Resolved 13 April 1994
Electrical
Issued 24 February 1994 Resolved
Install cover over battery box in engine room.
Condition: Unknown
Due 4 March 1994
Resolved 13 April 1994
Accommodation/Occupational Safety
Issued 24 February 1994 Resolved
Replace wood beams below engine room hatch covers and center deck wood panel above engines, and by port engine room vent.
Condition: Unknown
Due 4 March 1994
Resolved 13 April 1994
Engineering
Issued 3 March 1993 Resolved
Replace flame screens on port and starboard fuel tank vents.
Condition: Unknown
Due 7 April 1993
Resolved 7 April 1993
Construction/Loadline
Issued 3 March 1993 Resolved
Replace inter costal frams for flush deck hatch in forward passenger area.
Condition: Unknown
Due 7 April 1993
Resolved 7 April 1993
Construction/Loadline
Issued 3 March 1993 Resolved
Open and inspect fiberglass on port bow as marked. Renew hull plating as required.
Condition: Unknown
Due 7 April 1993
Resolved 7 April 1993
Construction/Loadline
Issued 3 March 1993 Resolved
Open and inspect decking port aft passenger area. Renew framing and decking as required.
Condition: Unknown
Due 7 April 1993
Resolved 7 April 1993
Engineering
Issued 3 March 1993 Resolved
Properly install remote fuel cutoffs so they can be operated above deck andlabel "FUEL CUT-OFF".
Condition: Unknown
Due 7 April 1993
Resolved 7 April 1993
Engineering
Issued 3 March 1993 Resolved
Renew battery cables and replace battery terminal lugs with solder type connectors.
Condition: Unknown
Due 7 April 1993
Resolved 7 April 1993
Engineering
Issued 3 March 1993 Resolved
Prove proper operation of port engine water temperature gauge.
Condition: Unknown
Due 7 April 1993
Resolved 7 April 1993
Construction/Loadline
Issued 3 March 1993 Resolved
Repair approx. 8"x8" rotted section on port bow as marked.
Condition: Unknown
Due 7 April 1993
Resolved 7 April 1993
Engineering
Issued 12 February 1992 Resolved
PROVIDE SPRAY SHIELD FOR RECOR FUEL FILTER LOCATED IN ENGINEROOM.
Condition: Unknown
Due 12 May 1992
Resolved 12 May 1992
Construction/Loadline
Issued 12 February 1992 Resolved
MAKE PERMANENT REPAIRS TO ALL WASTED AREAS OF DECK LOCATED AT AFTER PASSENGER AREA. UNTIL THIS TIME NO PASSENGERS ARE ALLOWED IN AFT PASSENGER AREA, VESSEL MUST EMBARK AND DISEMBARK PASSENGERS OVER PORTSIDE AND A TOTALOF 44 PASSENGERS MAY BE CARRIED.
Condition: Unknown
Due 12 May 1992
Resolved 12 May 1992
Lifesaving
Issued 12 February 1992 Resolved
REPLACE ALL WASTED RETRO-REFLECTIVE TAPE ON LIFEJACKETS, AS NECESSARY.
Condition: Unknown
Due 12 May 1992
Resolved 12 May 1992
Construction/Loadline
Issued 12 February 1992 Resolved
PROVIDE ADDITIONAL DECK SUPPORT FOR AREA OF DECK LOCATED DIRECTLY BEHIND HATCH FOR PORT MAIN DIESEL ENGINE.
Condition: Unknown
Due 12 May 1992
Resolved 12 May 1992
Electrical
Issued 12 February 1992 Resolved
PROVIDE LIGHT, GLOBE, AND CAGE FOR LIGHT SOCKETS IN ENGINEROOM.
Condition: Unknown
Due 12 May 1992
Resolved 12 May 1992
Fire Fighting
Issued 12 February 1992 Resolved
PERMANENTLY MOUNT B-II FIRE EXTINGUISHER, LOCATED STARBOARD SIDE FORWARD, TO BULKHEAD.
Condition: Unknown
Due 12 May 1992
Resolved 12 May 1992
Electrical
Issued 12 February 1992 Resolved
MAKE PROPER WIRING CONNECTIONS THROUGHOUT VESSEL.
Condition: Unknown
Due 12 May 1992
Resolved 12 May 1992
Lifesaving
Issued 12 February 1992 Resolved
PROVIDE A 60' LINE FOR RING BUOY IN ACCORDANCE WITH 46 CODE OF FEDERAL REGULATIONS (CFR) 180.30-1(2A).
Condition: Unknown
Due 12 May 1992
Resolved 12 May 1992
Construction/Loadline
Issued 8 March 1991 Resolved
COMPLETE INSTALLATION OF COLLISION BULKHEAD AS REQIRED BY 46 CFR171.040_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 March 1991
Resolved 8 March 1991
Lifesaving
Issued 8 March 1991 Resolved
REPLACE RETRO FLECTIVE TAPE ON ALL LIFE JACKETS AS REQUIRED._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 March 1991
Resolved 8 March 1991
Fire Fighting
Issued 9 March 1990 Resolved
VESSEL IS REQUIRED INSTALLED POWER OPERATED FIRE PUMP. THE PUMP SHALL BE SELF PRIMING AND OF SUCH SIZE AS TO DISCHARGE AN EFFECTIVE STREAM. ONE (1) HOSE AND STATION REQUIRED. HOSE MUST BE AT LEAST 5/8 I.D. AND 25 FEET IN LENGTH. PASSENGERS REDUCED TO 49 UNTIL CORRECTED AND TESTED BY COAST GUARD.
Condition: Unknown
Due 9 March 1990
Resolved 9 March 1990
Construction/Loadline
Issued 16 March 1989 Resolved
VESSEL MUST BE DRYDOCKED AS REQUIRED NO LATER THAN 15 APRIL 1989.
Condition: Unknown
Due 16 March 1989
Resolved 16 March 1989
Navigation
Issued 17 March 1988 Resolved
NAVIGATION LIGHTS MUST BE MADE OPERATIONAL.UNTIL THIS REQUIREMENT IS CORRECTED THE VESSEL IS RESTRICTED TO DAYLIGHT OPERATIONS ONLY.
Condition: Unknown
Due 17 March 1988
Resolved 17 March 1988
Engineering
Issued 17 March 1988 Resolved
WATER LEAK IN MANIFOLD ON STARBOARD ENGINE.
Condition: Unknown
Due 17 March 1988
Resolved 17 March 1988
Electrical
Issued 17 March 1988 Resolved
ALL ELECTRICAL WIRING MUST BE APPROVED FOR MARINE USE AND ALL SPLICES NEED TO BE CONNECTED BY APPROVED CRIMP CONNECTORS.
Condition: Unknown
Due 17 March 1988
Resolved 17 March 1988
Engineering
Issued 19 March 1987 Resolved
LOCATE SOURCE OF VEBRATION ON STARBOARD PROPELLER SHAFT AND REPAIR SAME.
Condition: Unknown
Due 19 March 1987
Resolved 19 March 1987
Electrical
Issued 19 March 1987 Resolved
REPAIR PASSENGER ACCOMODATION SPACE LIGHTING.
Condition: Unknown
Due 19 March 1987
Resolved 19 March 1987
Electrical
Issued 19 March 1987 Resolved
RECHARGE BOTH 12V BATTERIES.
Condition: Unknown
Due 19 March 1987
Resolved 19 March 1987
Electrical
Issued 19 March 1987 Resolved
REPAIR ELECTRICAL SWITCHBOARD AT MAIN CONSOLE BY COVERING ALL EXPOSED WIRES AND REMOVING UNUSED EXCESS WIRING. PROVIDE WIRING DIAGRAM AND FORWARD TO U.S. COAST GUARD PONCE, PR FOR REVIEW.
Condition: Unknown
Due 19 March 1987
Resolved 19 March 1987
Lifesaving
Issued 19 March 1987 Resolved
REPAIR OR REPLACE 26 ADULT AND 4 CHILDREN LIFE JACKETS. VESSEL RESTRICTED TO CARRYING 39 TOTAL PERSONS ONLY THREE OF MAY BE CHILDREN UNTIL THIS ITEM IS CORRECTED.
Condition: Unknown
Due 19 March 1987
Resolved 19 March 1987
Engineering
Issued 13 November 1985 Resolved
PROVIDE EVIDENCE THAT THE PORT FUEL TANK FILL HOSE HAS A HIGH RESISTENCE TOOIL, HEAT, AND VIBRATION. 46CFR 182.10-30
Condition: Unknown
Due 13 November 1985
Resolved 13 November 1985
Engineering
Issued 13 November 1985 Resolved
INSTALL TWO CLAMPS ON THE ENDS OF ALL FUEL HOSES INCLUDING FILL, SUPPLY ANDRETURN LINES. 46CFR 182.20-30
Condition: Unknown
Due 13 November 1985
Resolved 13 November 1985
Fire Fighting
Issued 10 May 1985 Resolved
INSTALL A FIXED POWER FIRE PUMP WITH MAIN DECK FIRE STATION.
Condition: Unknown
Due 10 May 1985
Resolved 10 May 1985

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.