Records from 2016 to 2018. Most recent: inspection, 25 January 2018.
Inspection history · 7
25 January 2018
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6341623
30 May 2017
Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6160033
25 May 2017
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6155488
12 January 2017
Administrative Inspection · COE-Dockside
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6070049
4 November 2016
PII Safety Exam · Deficiency Check · Ballast Water Examination · ISPS III Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6031956
8 April 2016
PII Safety Exam · ISPS III Exam · Deficiency Check · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5848562
16 February 2016
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5816037
Electrical › Lighting (emergency) › Lighting Fixture
Issued 25 January 2018
Resolved
0680-Embarkation Arrangement Surv. Craft - Muster and embarkation stations shall be adequately illuminated by lighting supplied from the emergency source of electrical power required by regulation II-1/43. Vessel's emergency lighting for lifeboat muster station was found inoperable. SOLAS 74 (1997 Cons) III/11.4 - 10 c.
Action required: 705 - Other - as specified
Resolved 25 January 2018
Resolution: Vessel cleared the short in the curcuit, replaced the lighting fixture and tested satisfactorily.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 25 January 2018
Resolved
0650-Lifebuoys - Not less than one half of the total number of lifebuoys shall be provided with lifebuoy self-igniting lights. Various self-igniting lights on main deck were found inoperable. SOLAS 74 (1997 Cons) III/7.1.3 - 10 c.
Action required: 705 - Other - as specified
Resolved 25 January 2018
Resolution: Vessel had spares onboard, lights were replaced.
Accommodation/Occupational Safety › Medical/First Aid › Hospital Space
Issued 25 May 2017
Resolved
0370- Water closet accommodation shall be provided for the exclusive use of the occupants of the hospital accommodation. Vessel had swapped a cabin with hospital space without an exclusive water closet. ILO-147 p38/30 PWSA 33 USC 1223(b)1
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 30 May 2017
Resolution: Vessel sent pictures of the corrections made to the hospital room. Hospital is no longer being used as accommodation.
Engineering › Fuel Oil Service System › Piping
Issued 8 April 2016
Resolved
SOLAS (97) II-2/15.2 While conducting an examination of the engine room the PSCO found a steady fuel leak before the #3 cylinder fuel pump on the main engine.
Action required: 703 - Prior to bunkering operations
Resolved 9 April 2016
Resolution: Recieved classifcation report attesting to repairs.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 8 April 2016
Resolved
SOLAS (97)II-2/15.3 PSCO found approximately 05 gallons of lubricating oil on the deck in the emergency generator room cause by an unknown source.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 April 2016
Resolution: Recieved classifaction report attesting to repairs.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 8 April 2016
Resolved
SOLAS (04) II-1/45.2 PSCO observed that a large portion of the back panel to the main switchboard has been removed, exposing live electrical components.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 4 November 2016
Resolution: Vessel's crew has installed proper covers on back panel of main switchboard.