MAURY USCG vessel records Sign in
← All vessels

ISLAND QUEEN

ISLAND QUEEN is a 1998 passenger vessel (inspected). The Coast Guard has recorded 26 inspections since 1998, most recently in February 2020, along with 18 deficiencies and 1 operational control.

Records from 1998 to 2020. Most recent: inspection, 5 February 2020.

Built
1998
Last inspected
5 February 2020
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

488512
Flag
UNITED STATES
—
Maury page id
psix-488512

Inspections, by type

…with no type recorded1
Years with a record 19 calendar years (1998–2020)
The 26 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it2 - Regulatory (Subpart C or D), Net Ton
2 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 26

5 February 2020 Annual Inspection · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6901725
14 January 2019 Drydock Exam · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6609748
16 October 2018 Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6561291
28 September 2018 Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6469294
21 June 2018 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6452753
7 January 2017 Drydock Exam · DAPI Audit · Administrative Inspection · COI Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6067449
12 April 2016 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5852922
10 January 2012 COI Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4222133
3 January 2011 Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3919373
16 February 2010 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3681284
6 January 2009 Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3388651
7 January 2008 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3114512
29 January 2007 Simplified Stability Test
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2865272
16 March 2006 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2603738
5 January 2006 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2560658
9 December 2004 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2256183
4 February 2004 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2000632
7 January 2004 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1975831
3 January 2003 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1725460
3 January 2002 COI Inspection · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1474906
9 April 2001 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1422041
16 January 2001 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1366138
2 February 2000 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1403049
5 January 1999 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1469903
24 December 1998 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 807590
22 December 1998 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1404771

Deficiency record · 18

Documentation › Logs/Records › Operational Procedures for Engines or Equipment
Issued 7 January 2017 Resolved
Provide documentation on new engines and fuel tank for plan review. 46CFR176.20-1
Action required: 705 - Other - as specified
Due 25 January 2017
Resolved 19 January 2017
Resolution: Recieved proper documentation from owner.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 12 April 2016 Resolved
Procure first aid equipment in accordance with 46CFR160.041.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 26 April 2016
Resolved 21 April 2016
Resolution: Recieved pictures and reciept of proper kit.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 13 January 2012 Resolved
Provide the required items for first aid kit; Ammonia inhalants and tourniquet.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 February 2012
Resolved 9 February 2012
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 13 January 2012 Resolved
Replace expired battery in the waterlight
Action required: 705 - Other - as specified
Due 1 February 2012
Resolved 9 February 2012
Resolution: Replaced battery
Fire Fighting › Fire Bucket › Lanyard
Issued 13 January 2012 Resolved
Install the required line on the fire buckets onboard
Action required: 705 - Other - as specified
Due 1 February 2012
Resolved 9 February 2012
Resolution: Line was properly installed.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 16 February 2010 Resolved
Properly mark both port & starboard sides of the vessel with vessel's name and hailing port on the stern IAW 46 CFR 67.123.
Condition: Unknown
Action required: 705 - Other - as specified
Due 16 March 2010
Resolved 29 March 2010
Resolution: Owner properly marked both port & starboard sides of the vessel with vessel''s name and the vessel''s hailing port on the stern.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 16 February 2010 Resolved
Provide onboard an up to date first aid kit. (CG Approved)
Action required: 705 - Other - as specified
Due 16 March 2010
Resolved 29 March 2010
Resolution: Owner purchased a new Coast Guard approved first aid kit and had it placed on vessel.
Navigation › Piloting/Steering › US Coast Pilot
Issued 16 February 2010 Resolved
Provide onboard updated an Coast Pilot and CG Light List.
Action required: 705 - Other - as specified
Due 16 March 2010
Resolved 29 March 2010
Resolution: Reviewed picture of updated extract of CG light list and Coast Pilot and found satisfactory.
Electrical › Lighting (service) › Switch
Issued 16 February 2010 Resolved
Replace wire and switch for stern light with marine grade 14 AWG or larger wire and provide an in-line fuse protection for positive conductor IAW 46 CFR 183.340
Action required: 705 - Other - as specified
Due 16 March 2010
Resolved 29 March 2010
Resolution: Owner removed the wire and switch for stern light and hard wired a new in line fuse connection under the navigation bridge console.
Engineering › Fuel Oil Service System › Valve
Issued 16 February 2010 Resolved
Provide fuel shut-off valves or quick disconnects for both fuel tanks.
Action required: 705 - Other - as specified
Due 16 March 2010
Resolved 29 March 2010
Resolution: Observed two new in line fuel shut off valves installed as seen in the pictures.
Fire Fighting › Fire Bucket › Quantity
Issued 16 February 2010 Resolved
Provide onboard three 2 1/2gallon fire buckets with attached lanyard and labeled with "Fire Bucket'.
Action required: 705 - Other - as specified
Due 16 March 2010
Resolved 29 March 2010
Resolution: Three new 2 1/2 gallon fire buckets were bought and properly labeled with attached lanyard as seen from picture.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 16 February 2010 Resolved
Properly label adult and child life jackets stowage areas and number counts.
Action required: 705 - Other - as specified
Due 16 March 2010
Resolved 29 March 2010
Resolution: Two pictures showed that the adult and child lifejackets had the proper counts and labeling.
Engineering › Fuel Oil Service System
Issued 7 January 2004 Resolved
Properly install fuel filter on the stbd outboard engine. LEGACY COMPONENT DESC: Filter
Action required: 705 - Other - as specified
Due 7 February 2004
Resolved 5 February 2004
Lifesaving › Lifebuoys
Issued 7 January 2004 Resolved
Prove proper periodic testing of ring lifebuoy light. LEGACY COMPONENT DESC: Self-igniting Lights
Action required: 705 - Other - as specified
Due 7 February 2004
Resolved 5 February 2004
Construction/Loadline › Markings
Issued 7 January 2004 Resolved
Renew vessel name on vsl stern. LEGACY COMPONENT DESC: Vessel Name/Home Port
Action required: 705 - Other - as specified
Due 7 February 2004
Resolved 5 February 2004
Lifesaving › Lifejacket/PFD (Type I)
Issued 3 January 2002 Resolved
POST LIFEJACKET DONNING PLACARDS I.A.W. 46 CFR 185.516 LEGACY COMPONENT DESC: Marking
Due 3 February 2002
Resolved 31 January 2002
Accommodation/Occupational Safety › Heating
Issued 3 January 2002 Resolved
PRIOR TO USE, PROVIDE PROOF THAT GAS HEATER CONFORMS WITH 46 CFR 184.200. LEGACY COMPONENT DESC: Burners
Due 3 February 2002
Resolved 31 January 2002
Resolution: Owner/Operator removed heater from vessel.
Lifesaving › Lifebuoys
Issued 3 January 2002 Resolved
LABEL RING LIFE BUOY AND 3 LIFE JACKETS WITH VESSEL NAME. LEGACY COMPONENT DESC: Markings (ship name/port)
Due 3 February 2002
Resolved 31 January 2002

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.