MAURY USCG vessel records
← All vessels

TENACIOUS

TENACIOUS is a 1976 passenger vessel (inspected). The Coast Guard has recorded 19 inspections since 2016, most recently in May 2026, along with 8 deficiencies — 1 with no resolution recorded —.

Records from 2016 to 2026. Most recent: inspection, 14 May 2026.

Built
1976
Last inspected
14 May 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 14 May 2026
…with no type recorded2
…past their stated due date1
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDP5897
Flag
UNITED STATES
Maury page id
psix-48854

Documentation record

Registered dimensions (L × B × D)48.3 ft × 15.7 ft × 6.7 ft
Registered tonnagegross 37 / net 25
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDELTA MARINE INDUSTRIES INC · SEATTLE, WA, UNITED STATES · built 1976
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSEWARD, AK
Trade endorsementsCoastwise, unrestricted, Fishery, Registry
DocumentationValid · issued 3 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it37 - Regulatory (Subpart C or D), Gross Ton
25 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 19

14 May 2026 Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 8373080
22 April 2026 Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8330504
3 June 2025 Administrative Inspection · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8152419
3 May 2024 Administrative Inspection · COI Inspection · Drydock Exam
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7905800
28 July 2023 Type not recorded
No type recorded · USCGC LIBERTY (WPB 1334) · USCG Arctic District (CGD-A) · Activity 7765037
25 May 2023 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7696598
28 April 2022 Annual Inspection · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7442761
20 April 2022 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7438050
24 July 2021 Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 7302294
24 May 2021 Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7206394
9 July 2020 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7002159
25 April 2020 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6977851
10 October 2019 Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6832512
9 May 2019 Administrative Inspection · COI Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 6680297
12 May 2018 Annual Inspection · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6412690
6 April 2018 Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6390678
2 May 2017 Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6137224
18 May 2016 Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5914520
26 April 2016 Administrative Inspection · Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5845501

Deficiency record · 8

07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 4 June 2025 No resolution recorded
07199 - Fuel filter and strainer bowls must be highly resistant to shattering due to mechanical impact and resistant to failure due to thermal shock. Fuel filters fitted with bowls of other than steel construction must be approved by the Commandant and be protected from mechanical damage. Approval of bowls of other than steel construction will specify if a flame shield is required. Vessel is using a fuel filter with a clear engineering plastic for the diesel generator installed on board, which is not suitable for use with diesel installations or within enclosed spaces according to manufacturer. 46 CFR 182.455(b)(6)
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2025 — due date passed with no resolution recorded
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 27 June 2023 Resolved
All radiotelephones must contain the MMSI and integral GPS capabilities or must be connected to an electronic position-fixing device. VHF radios must have the MMSI programmed and linked to GPS.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 July 2023
Resolved 21 May 2024
Resolution: MMSI programed on all radios
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 27 June 2023 Resolved
The vessel must comply with the all applicable FCC Radio requirements. The MMSI and Call Signs are different on every certificate and license.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 July 2023
Resolved 21 May 2024
Resolution: Vsl has updated MMSI and is listed on all radios
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 May 2019 Resolved
Missing fire buckets or proper fire hose nozzle. 46CFR181.32
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2019
Resolved 28 May 2019
Resolution: Provided 3 fire buckets.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 16 May 2018 Resolved
Suitable guards shall be installed in way of all exposed and hazardous places. Guards must be installed on rotating machinery on the engines.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2018
Resolved 22 May 2018
Resolution: Verified installation of machine guards. All sat.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 19 May 2016 Resolved
Install captive device to engine room hatch cover (46CFR179.360)(b)(1).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 June 2016
Resolved 8 June 2016
Resolution: Captive device installed.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 19 May 2016 Resolved
Provide copy of FCC Safety certificate (47CFR80).
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 June 2016
Resolved 7 July 2016
Resolution: Rcvd email picture of valid certificate.
Engineering › Diesel Engine (auxiliary) › Emergency shutdown
Issued 19 May 2016 Resolved
Install generator automatic shutdown.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 18 June 2016
Resolved 8 June 2016
Resolution: Witnessed generator shutdown upon simulated actuation of pre-engineered fixed fire extinguishing system.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.