Records from 2017 to 2022. Most recent: inspection, 23 July 2022.
Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
Professional
Detail on this page
15 inspections, each with its date, unit and type; 13 deficiencies with the resolution recorded against each; the documentation record, as PSIX holds it. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
Plans
Sign in
Maury does not score, rate or grade vessels, at any price.
Inspection history · 15
23 July 2022
PSC B
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7509342
11 April 2022
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7429116
22 December 2021
PSC B
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7369537
18 June 2021
PSC B
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7228751
2 June 2021
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7212883
24 March 2021
PSC B
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7158277
25 August 2020
PSC B
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7038617
13 March 2020
Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6931662
25 January 2020
PSC B
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6895886
11 April 2019
Deficiency Check · Administrative Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6660180
12 March 2019
PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6640593
13 September 2018
Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6539267
19 July 2018
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6481801
24 August 2017
PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6248996
10 February 2017
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6083743
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 24 June 2021
Resolved
all lifesaving appliances shall be in working order and ready for immediate use. took crew over ten minutes to start the rescue boat. starter line was faulty and has been repaired. an immediate start was demonstrated.
SOLAS 74 (14 CONS) CHAP III REG 20.2
Action required: 10 - Deficiency Rectified
Due 24 June 2021
Resolved 24 June 2021
Resolution: starter line was faulty and has been repaired. an immediate start was demonstrated.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 24 March 2021
Resolved
CABLES AND WIRING SHALL BE INSTALLED AND SUPPORTED IN SUCH A MANNER AS TO AVOID CHAFING AND OTHER DAMAGE. ELECTRICAL BOX AND WIRES FOR BOW THRUSTER LUBE OIL PUMP AND MOTOR FAN IS NOT SECURED OR MOUNTED TO PREVENT CHAFING AND DAMAGE.
SOLAS 74 (04 CONS) CH II-1 REG 45.5.5
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 24 June 2021
Resolution: REVIEWED CLASS SURVEY FROM VESSEL'S MAY 2021 DRY DOCK ATTESTING TO REPAIRS. ALSO VERIFIED REPAIRS DURING THE EXAM AND FOUND ALL SAT.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 24 March 2021
Resolved
"A" CLASS DIVISIONS ARE THOSE DIVISIONS FORMED BY BULKHEADS AND THAT SHALL BE CONSTRUCTED AS TO BE CAPABLE OF PREVENTING THE PASSAGE OF SMOKE AND FLAME TO THE END OF THE ONE-HOUR STANDARD FIRE TEST. GALLEY PASS THROUGH WINDOW DOES NOT FULLY SEAT WHEN SHUT ALLOWING PASSAGE OF SMOKE AND FLAME TO ESCAPE INTO CREW'S MESS.
SOLAS 74(97 CONS) CH II-2 REG 3.3.3
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 24 June 2021
Resolution: REVIEWED CLASS SURVEY FROM VESSEL'S MAY 2021 DRY DOCK ATTESTING TO REPAIRS. ALSO VERIFIED REPAIRS DURING THE EXAM AND FOUND ALL SAT.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 24 March 2021
Resolved
THE MAIN INLETS AND OUTLETS OF ALL VENTILATION SYSTEMS SHALL BE CAPABLE OF BEING CLOSED FROM OUTSIDE THE SPACES BEING
VENTILATED. THE WEATHERTIGHT HATCH AND LATCH ON TUNNEL FUNNEL IS WASTED AND MISSING ALL AROUND WEATHERTIGHT GASKET.
SOLAS 74 (97 CONS) CH II-2 REG 48, 16.9
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 24 June 2021
Resolution: REVIEWED CLASS SURVEY FROM VESSEL'S MAY 2021 DRY DOCK ATTESTING TO REPAIRS. ALSO VERIFIED REPAIRS DURING THE EXAM AND FOUND ALL SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 24 March 2021
Resolved
SPARES AND REPAIR EQUIPMENT SHALL BE PROVIDED FOR LIFE-SAVING APPLIANCES AND THEIR COMPONENTS WHICH ARE SUBJECT TO EXESSIVE WEAR AND NEED TO BE REPLACED REGULARLY. RESCUE BOAT LIFTING SHACKLES ARE WASTED AND THE PINS ARE SEIZED.\
SOLAS 74 (14 CONS)CH III REG 19.5
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 24 June 2021
Resolution: REVIEWED CLASS SURVEY FROM VESSEL'S MAY 2021 DRY DOCK ATTESTING TO REPAIRS. ALSO VERIFIED REPAIRS DURING THE EXAM AND FOUND ALL SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 24 March 2021
Resolved
AT ALL TIMES DURING THE VOYAGE, ALL LIFE-SAVING APPLIANCES SHALL BE IN WORKING ORDER AND READY FOR IMMEDIATE USE. RESCUE BOAT PORT OAR YOKE IS WASTED AND SEPARATING FROM TOP GUNWHALE. PORT INBOARD FORWARD BENCH IS DELAMINATED AND SEPARATING FROM HULL.
SOLAS 74 (14CONS) CH III REG 19.2
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 24 June 2021
Resolution: REVIEWED CLASS SURVEY FROM VESSEL'S MAY 2021 DRY DOCK ATTESTING TO REPAIRS. ALSO VERIFIED REPAIRS DURING THE EXAM AND FOUND ALL SAT.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 31 January 2020
Resolved
WHERE THE EMERGENCY SOURCE OF POWER IS A GENERATOR IT SHALL BE AUTOMATICALLY CONNECTED TO THE EMERGENCY SWITCHBOARD UPON LOSS OF POWER. THE EMERGENCY DIESEL GENERATORS CIRCUIT BREAKER IS UNABLE TO CLOSE AND SUPPLY POWER TO THE EMERGENCY SWITCHBOARD.
74SOLAS(97) II-1/43.3.1.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 2 February 2020
Resolution: Verified on board the proper operation to supply power.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 31 January 2020
Resolved
ARRANGEMENTS PROVIDED FROM ACCOMODATION SPACES AND SPACES IN WHICH THE CREW NORMALLY EMPLOYED. READY MEANS OF ESCAPE TO OPEN DECKS IS NOT POSSIBLE. THE DOORS ARE PADLOCKED FROM THE OUTSIDE AND PERSONNEL ARE UNABLE TO BE OPEN FROM THE INSIDE AND ESCAPEE IN CASE OF EMERGENCY.
74SOLAS(97)II-2/45.1
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 February 2020
Resolution: Verified all internal release bolts for the security locks on doors were maintain to allow egress of the ship.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 31 January 2020
Resolved
THE MEANS FOR SECURING AND MAINTAINING WEATHER TIGHTNESS SHALL BE MAINTAIEND IN ALL SEA CONDITIONS. THE MAIN DOOR FROM MAIN DECK TO THE ACCOMODATION SPACE IS NOT WEATHER TIGHT AND SEVERLY WASTED.
ICLL66 1/16(4)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 13 March 2020
Resolution: Received Class Report attesting to the correction.
09 - Working and Living Conditions › 092 - Working Conditions › Emergency cleaning devices
Issued 31 January 2020
Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATION TO ENSURE THE SHIP WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONNEL ON BOARD. EYE WASH STATIONS THROUGHOUT THE SHIP ARE BROKEN, RUSTED, AND NOT FUNCTIONING AS DESIGNED.
74SOLAS(14)I/11(9)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 13 March 2020
Resolution: Received Class Report attesting to the correction.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 12 March 2019
Resolved
Alkaline batteries in self ignighting lights on lifebuoys were found expired. Batteries must be replaced annually.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 12 March 2019
Resolved 12 March 2019
Resolution: Batteries were replaced and logged
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 12 March 2019
Resolved
Retro reflective tape found missing on bottom of rescue boat. Life boat and rescue boat are required to have retro reflective tape on bottom if not self righting.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 April 2019
Resolved 11 April 2019
Resolution: INSTALLED ADDITIONAL RETRO-REFLECTIVE TAPE
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 19 July 2018
Resolved
After survey of the ship no change shall be made in the equipment. Engine room watertight door leading forward leaks hydraulic fluid from the top ram seal when in operation.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 August 2018
Resolved 13 September 2018
Resolution: Class report cleared defs