Records from 2005 to 2022. Most recent: inspection, 29 July 2022.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 16
29 July 2022
Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7519663
8 June 2021
Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7221191
5 January 2021
Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7120154
25 November 2019
Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6862320
31 October 2019
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6846064
20 June 2018
COI Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6430325
7 August 2017
COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6233041
13 June 2016
Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5906523
20 October 2015
Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5747056
2 October 2015
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5735493
19 January 2012
Administrative Inspection · Plan Review "T" Boat · Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4227481
11 January 2012
Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4223095
16 November 2010
Examination of Repairs
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3892339
4 October 2010
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3859431
8 December 2009
Welding Related Inspections Qualification Testing · In-Service Inspection · Drydock Exam · Administrative Inspection · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3644336
2 May 2005
Re-Inspection · Initial Certification · Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2347438
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 31 October 2019
Resolved
Vessel is pass due for its required dry dock and ISE.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 June 2021
Resolution: Completed def check
10 - Safety of Navigation › N/A - No Subsystem › Life-saving signals
Issued 29 August 2018
Resolved
install one flare.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 September 2018
Resolved 3 October 2018
Resolution: Flare installed
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 August 2018
Resolved
Post emergency instruction list.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 September 2018
Resolved 3 October 2018
Resolution: Emergency list on board
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 29 August 2018
Resolved
Repair stern light
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 September 2018
Resolved 3 October 2018
Resolution: Stern light repaired.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 29 August 2018
Resolved
Print light list and Coast pilot.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 September 2018
Resolved 3 October 2018
Resolution: Light list and coast pilot printed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 August 2018
Resolved
Install new battery in float light.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 September 2018
Resolved 3 October 2018
Resolution: Battery replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Ropes and wires
Issued 29 August 2018
Resolved
Seize shackle pins on rigging.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 September 2018
Resolved 3 October 2018
Resolution: shackles siezed
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 29 August 2018
Resolved
Repair PS emergency fuel shut off.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 September 2018
Resolved 3 October 2018
Resolution: fuel shut off repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 29 August 2018
Resolved
Reomove unauthorized fuel sight guages on both fuel tanks.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 September 2018
Resolved 3 October 2018
Resolution: removed.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 29 August 2018
Resolved
Life raft has not been serviced and is not required as per COI. Told the owner that if he does not service the liferaft then it needs to be removed.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 September 2018
Resolved 3 October 2018
Resolution: Life raft removed.
Sail Rigging › Spars › Spreaders and Bases
Issued 13 June 2016
Resolved
Renewed rotted port spreader on the mizzen mast.
Action required: 705 - Other - as specified
Resolved 1 November 2019
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 2 October 2015
Resolved
Fire system needs to be inspected.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 November 2019
Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 2 October 2015
Resolved
Provide proof of drug consortium enrollment.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 October 2015
Resolution: Owner provided proof of enrolment.
Documentation › Manifests/Lists › Emergency Checkoff List
Issued 2 October 2015
Resolved
Provide emergency instructions list.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 November 2019
Sail Rigging › Running Rigging › Shackles
Issued 19 January 2012
Resolved
Replace bolt for boom on main mast.
Action required: 705 - Other - as specified
Resolved 30 September 2014
Resolution: Bolt replaced on main mast.
Documentation › Certificates/Documents › Stability Letter
Issued 11 January 2012
Resolved
IAW with the your stability intention worksheet-Submission of new stability calculations for review and weight ratio calculations, you are limited to carrying 36 total persons which 03 may be crew. You are further limited by the restrictions on your Certificate of Inspection.
Action required: 705 - Other - as specified
Resolved 30 September 2014
Resolution: New COI drafted with new passenger count. See vessel notes for passenger count.
Construction/Loadline › Structures › Superstructure
Issued 16 November 2010
Resolved
make proper repairs to the main deck starboard side IWO the cockpit.
Due 11 December 2011
Resolved 11 June 2014
Resolution: Repairs complete.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 4 October 2010
Resolved
Make structural repairs as necessary due to wastage in way of forward centerboard trunk, forward engine room bulkhead, and overhead/deck, starboard side forward of head. To be completed at next drydock period.
Action required: 705 - Other - as specified
Due 27 May 2011
Resolved 27 May 2011
Resolution: Main deck still needs to be repaired. Requirment extended until Dec 11, 2011
Documentation › Certificates/Documents › Certificate of Inspection
Issued 1 March 2010
Resolved
Vessel is permitted to transit from Jacksonville, FL, to her homeport in Connecticut with an overdue annual examination. Vessel is restricted from carrying passengers until completing an annual COI exam from Sector Long Island.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 June 2010
Resolved 17 June 2010
Resolution: Inspection Completed
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 8 December 2009
Resolved
Work list item #4: Repair cracked stanchions #3 and #7 STBD side, and #8 PORT side.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 June 2010
Resolution: Stanchions Repaired
Stability › Unintentional Flooding › General
Issued 2 May 2005
Resolved
Install port light covers at next hull exam.
Due 31 October 2009
Resolved 17 June 2010
Resolution: Port light covers installed