Records from 2016 to 2022. Most recent: inspection, 29 July 2022.
Inspection history · 8
29 July 2022
Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7519663
8 June 2021
Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7221191
5 January 2021
Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7120154
25 November 2019
Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6862320
31 October 2019
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6846064
20 June 2018
COI Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6430325
7 August 2017
COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6233041
13 June 2016
Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5906523
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 31 October 2019
Resolved
Vessel is pass due for its required dry dock and ISE.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 June 2021
Resolution: Completed def check
10 - Safety of Navigation › N/A - No Subsystem › Life-saving signals
Issued 29 August 2018
Resolved
install one flare.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 September 2018
Resolved 3 October 2018
Resolution: Flare installed
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 August 2018
Resolved
Post emergency instruction list.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 September 2018
Resolved 3 October 2018
Resolution: Emergency list on board
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 29 August 2018
Resolved
Repair stern light
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 September 2018
Resolved 3 October 2018
Resolution: Stern light repaired.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 29 August 2018
Resolved
Print light list and Coast pilot.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 September 2018
Resolved 3 October 2018
Resolution: Light list and coast pilot printed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 August 2018
Resolved
Install new battery in float light.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 September 2018
Resolved 3 October 2018
Resolution: Battery replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Ropes and wires
Issued 29 August 2018
Resolved
Seize shackle pins on rigging.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 September 2018
Resolved 3 October 2018
Resolution: shackles siezed
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 29 August 2018
Resolved
Repair PS emergency fuel shut off.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 September 2018
Resolved 3 October 2018
Resolution: fuel shut off repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 29 August 2018
Resolved
Reomove unauthorized fuel sight guages on both fuel tanks.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 September 2018
Resolved 3 October 2018
Resolution: removed.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 29 August 2018
Resolved
Life raft has not been serviced and is not required as per COI. Told the owner that if he does not service the liferaft then it needs to be removed.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 September 2018
Resolved 3 October 2018
Resolution: Life raft removed.
Sail Rigging › Spars › Spreaders and Bases
Issued 13 June 2016
Resolved
Renewed rotted port spreader on the mizzen mast.
Action required: 705 - Other - as specified
Resolved 1 November 2019