Inspection history · 21
30 September 2025
Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8226791
20 March 2025
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8093920
25 October 2024
Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8016185
11 October 2023
Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7802472
26 April 2023
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7676127
1 November 2022
Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7587603
12 May 2022
Deficiency Check · Examination of Repairs
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7466253
23 August 2021
Internal Structural Exam · DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7294435
29 March 2021
Hull Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7153443
18 August 2020
Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7035343
7 November 2019
Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6851104
6 February 2019
Deficiency Check · Hull Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6621189
2 November 2018
Type not recorded
No type recorded · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6573399
26 July 2018
Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6491001
11 January 2018
Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6336148
5 December 2017
Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6318789
28 August 2017
Examination of Repairs
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6253954
7 July 2017
Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6201084
25 April 2017
Hull Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6132812
6 October 2016
COI Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6016850
10 May 2016
Examination of Repairs · Plan Review "T" Boat
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 5876385
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 30 September 2025
No resolution recorded
Complete annual service of FF equipment prior to passenger service in spring 2026.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 May 2026 — due date passed with no resolution recorded
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 30 September 2025
No resolution recorded
Complete drills prior to passenger operations in spring 2026.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 May 2026 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 11 October 2023
Resolved
A dual voltage generator installed on a vessel shall be of the grounded type, where: (1) The neutral of a dual voltage system must be solidly connected at the switchboard's neutral bus; and (2) The neutral bus shall be connected to ground. (b) The neutral of a dual voltage system must be accessible for checking the insulation resistance of the generator to ground before the generator is connected to the bus. (c) Ground detection must be provided that: (1) For an alternating current system, meets § 111.05–27 in subchapter J of this chapter.
Vessel did not have ground detection during the time of inspection.
46 CFR 183.324
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 November 2023
Resolved 1 May 2024
Resolution: Vessel had marine electrician rectify the deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 October 2023
Resolved
An adult life jacket must be provided for each person carried on board a vessel.
During the time of inspection 20 Life jackets had been found to show signs of aging and/or damage and shall be replaced.
46 CFR 180.71
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 November 2023
Resolved 19 October 2023
Resolution: Vessel POC submitted pictures rectifying the deficiency.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 29 March 2021
Resolved
Prove operation of starboad cabin door.
Action required: 705 - Other - as specified
Due 30 April 2021
Resolved 12 May 2022
Resolution: Door repaired, test sat.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 29 March 2021
Resolved
Repair/Replace latch on port fwd embarkation door.
Action required: 705 - Other - as specified
Due 30 April 2021
Resolved 12 May 2022
Resolution: New latch installed on door.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 29 March 2021
Resolved
Address corroison around thru-hull fittings to raw water gear discharge, P/S sides.
Action required: 705 - Other - as specified
Due 30 April 2021
Resolved 12 May 2022
Resolution: Monitor of hull plate IWO thru hull fittings.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 29 March 2021
Resolved
Lubricate/Exercise bilge overboard valves.
Action required: 705 - Other - as specified
Due 30 April 2021
Resolved 12 May 2022
Resolution: Operation test sat of bilge system prior to passenger service.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 March 2021
Resolved
Clean up aluminum oxide deposits on aluminum exhaust elbow, port engine room aft bulkhead.
Action required: 705 - Other - as specified
Due 30 April 2021
Resolved 12 May 2022
Resolution: Oxide deposits removed IWO area in engine room.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 29 March 2021
Resolved
Install lanyard on stbd jet room hatch.
Action required: 705 - Other - as specified
Due 30 April 2021
Resolved 12 May 2022
Resolution: Lanyard installed on hatch.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 1 November 2018
Resolved
Provide proof of EPIRB service (expired battery). Vessel restricted to 3 miles until corrected.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 December 2018
Resolved 29 January 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 November 2018
Resolved
Repair or replace two ring buoys. (grab lines have UV degredation).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 December 2018
Resolved 29 January 2019
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 1 November 2018
Resolved
Repair/Replace Black Water Tank. (Repair proposal Required).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 December 2018
Resolved 26 March 2019
Resolution: Tank being eplaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 November 2018
Resolved
Adjust hose clamp on starboard main exhaust (collapsing bellows).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 December 2018
Resolved 26 March 2019
Resolution: New bellows being installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 November 2018
Resolved
Replace standard outlets with covered GFCI outlets in jet rooms.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 December 2018
Resolved 29 January 2019
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 13 December 2017
Resolved
Provide updated Eldridge/tide tables.
Action required: 705 - Other - as specified
Due 13 January 2018
Resolved 11 January 2018
Resolution: Latest copy of Eldrige provided.
Communications › Alarms/Indicators › Fire Alarm
Issued 13 December 2017
Resolved
Repair heat sensor in port engine room.
Action required: 705 - Other - as specified
Due 1 February 2018
Resolved 8 February 2018
Fire Fighting › Fire Pumps › Pressure
Issued 13 December 2017
Resolved
Replace gage on fire pump.
Action required: 705 - Other - as specified
Due 13 December 2017
Resolved 11 January 2018
Resolution: New gage is installed.
Lifesaving › Lifebuoys › Serviceable
Issued 13 December 2017
Resolved
Replace ring buoy waterlight and install new battery.
Due 13 January 2018
Resolved 11 January 2018
Resolution: New waterlight/battery installed.
Electrical › Electric Generation Source (service) › Conductor
Issued 13 December 2017
Resolved
Tighten postive lead to battery on starboard bank.
Action required: 705 - Other - as specified
Due 13 January 2018
Resolved 11 January 2018
Resolution: All battery leads checked and tightened.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 13 December 2017
Resolved
Prove operation of vent covers (means of securing).
Action required: 705 - Other - as specified
Due 13 December 2017
Resolved 11 January 2018
Resolution: Wing nuts provided on all vent cover studs.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 13 December 2017
Resolved
Complete repair of port and starboard loading gates on main deck.
Action required: 705 - Other - as specified
Due 1 February 2018
Resolved 8 February 2018
Fire Fighting › Fixed CO2 Fire Extinguishing System › Remote Pulls
Issued 6 October 2016
Resolved
Provide striker for jet room CO2 pull box.
Due 6 November 2016
Resolved 18 October 2016
Resolution: Striker now installed.
Electrical › Lighting (service) › Lighting Fixture
Issued 6 October 2016
Resolved
Replace broken light fixture in main salon.
Due 6 November 2016
Resolved 6 October 2016
Resolution: Master has replaced the cover.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 6 October 2016
Resolved
Repair broken seats on upper deck.
Due 1 May 2017
Resolved 7 July 2017
Resolution: New seats installed.