Records from 1998 to 2016. Most recent: inspection, 22 July 2016.
Inspection history · 15
22 July 2016
Initial Certification
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5949405
11 July 2016
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5940857
7 April 2008
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3179113
23 June 2005
Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2399988
7 June 2005
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2369181
6 June 2005
Simplified Stability Test
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2374493
22 April 2005
Examination of Repairs · Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2326875
1 March 2005
Administrative Inspection
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2301481
12 August 2004
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2163337
4 September 2003
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1881692
14 August 2002
Hull Examination · Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1660119
21 May 2001
Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1065688
4 May 2001
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1366324
12 July 2000
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1410357
25 June 1998
Initial Certification · Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1372665
Documentation › Certificates/Documents › Certificate of Inspection
Issued 7 April 2008
No resolution recorded
Expired COI
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 May 2008 — due date passed with no resolution recorded
Documentation › Logs/Records › Drug Test Records
Issued 7 June 2005
Resolved
Provide company drug and alcohol policy.
Due 21 June 2005
Resolved 8 June 2005
Resolution: Provided D&A policy.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 7 June 2005
Resolved
Provide means to leave passenger count landside.
Due 21 June 2005
Resolved 8 June 2005
Resolution: Constructed watertight PVC pipe mounted at mooring.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 7 June 2005
Resolved
Provide asprin for first aid kit.
Due 21 June 2005
Resolved 8 June 2005
Resolution: Provided.
Navigation › Piloting/Steering › Marine Charts
Issued 7 June 2005
Resolved
Provide charts of vessel's operating area.
Due 21 June 2005
Resolved 8 June 2005
Resolution: Provided.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 7 June 2005
Resolved
Provide tide/current tables for operating area.
Due 21 June 2005
Resolved 8 June 2005
Resolution: Provided.
Electrical › Electric Generation Source (service) › Conductor
Issued 7 June 2005
Resolved
Remove wing nuts or provide locking washer for battery terminal.
Due 21 June 2005
Resolved 8 June 2005
Resolution: Provided locking washers.
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 June 2005
Resolved
Make proper repairs to non-compression type electrical connections.
Due 21 June 2005
Resolved 8 June 2005
Resolution: Used compression type connections.
Documentation › Markings/Placards › Garbage Placard
Issued 7 June 2005
Resolved
Provide waste management placard.
Due 21 June 2005
Resolved 8 June 2005
Resolution: Provided.
Stability › Freeing Ports › General
Issued 7 June 2005
Resolved
Provide adequate freeing ports for water drainage. Vessel route is limilted to points north of a line drawn between Fields Point and Squantum Point.
Due 22 June 2005
Resolved 22 June 2005
Resolution: Vessel installed freeing ports in deck.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 12 August 2004
Resolved
Repair or replace the existing deteriorating floor
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 May 2005
Resolution: Floor was not deteriorated. Angel hair was found on the underside of the deck, but was not a substantial compared to the total thickness of the deck.
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 August 2004
Resolved
Replace the existing solid type wire with the properly sized stranded type wire
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 May 2005
Resolution: Replace household wire with standed marine-grade wire.
Stability › Watertight Integrity › General
Issued 12 August 2004
Resolved
Address the improper repair on the STBD side pontoon all the way aft.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 May 2005
Resolution: Replace end cap of starboard pontoon in-kind.
Stability › Watertight Integrity › General
Issued 12 August 2004
Resolved
Address the excessive water in the Port pontoon. Approx. 2 gallons of water came out during inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 May 2005
Resolution: Conducted leak-test on pontoon. No leaks were identified.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 12 August 2004
Resolved
Address the fastenings holding the deck to the frame, all of the nuts are rusted and deteriorated beyound a usable condition.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 May 2005
Resolution: Approximately 50% of the fastenings holding the deck to the frame were replaced. Remaining fasteners were found in acceptable condition.
Accommodation/Occupational Safety › Occupational Safety
Issued 22 September 2003
Resolved
Post "No Smoking Gasoline" sign aft starboard in way of portable fuel tanks. LEGACY COMPONENT DESC: Smoking
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 October 2003
Resolution: Placard attached to aft portion of vessel in way of gasoline storage.
Lifesaving › Hand Flares
Issued 4 September 2003
Resolved
Provide 3 day 3 night distress signal kit. Vessel signal kit expired July 2003 LEGACY COMPONENT DESC: Condition
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 October 2003
Resolution: Signal kit restocked with valid flares.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 14 August 2002
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Due 28 August 2002
Resolved 30 August 2002
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 14 August 2002
Resolved
REFASTEN POLES ON FWD STANCHION
Due 28 August 2002
Resolved 30 August 2002
Fire Fighting › Miscellaneous Items
Issued 14 August 2002
Resolved
PROVIDE 2 FIRE BUCKETS
Due 28 August 2002
Resolved 30 August 2002
Navigation › Collision/Grounding Avoidance
Issued 14 August 2002
Resolved
MAKE NAVIGATION LIGHTS CONNECTIONS PERMANENT LEGACY COMPONENT DESC: Navigation Lights
Due 28 August 2002
Resolved 18 September 2002
Documentation › Markings/Placards
Issued 14 August 2002
Resolved
PLACE REGISTRATION STICKER ALONGSIDE STATE REGISTRATION NUMBERS ON HULL LEGACY COMPONENT DESC: Certificate of Number (state)
Due 28 August 2002
Resolved 18 September 2002
Electrical › Electrical Distribution System (service)
Issued 14 August 2002
Resolved
PROVIDE BOX AND PROTECTIVE COVERING FOR BATTERY
Due 28 August 2002
Resolved 30 August 2002
Deck/Cargo › Emergency Steering
Issued 14 August 2002
Resolved
PROVIDE 6' CHAIN FOR ANCHOR
Due 28 August 2002
Resolved 30 August 2002
Unknown
Issued 4 May 2001
Resolved
PROVIDE LIFEJACKET DONNING PLACARD.
Condition: Unknown
Due 18 May 2001
Resolved 25 May 2001
Unknown
Issued 4 May 2001
Resolved
PROVIDE MISSING ADULT LIFEJACKET TO MEET REQUIRED 17.
Condition: Unknown
Due 18 May 2001
Resolved 25 May 2001
Unknown
Issued 4 May 2001
Resolved
PROVIDE 3 FT LINE WITH SNAP HOOK FOR WATER LIGHT.
Condition: Unknown
Due 18 May 2001
Resolved 25 May 2001
Unknown
Issued 4 May 2001
Resolved
PROVIDE ORIGINAL OF OPERATORS LICENSE.
Condition: Unknown
Due 18 May 2001
Resolved 25 May 2001
Unknown
Issued 4 May 2001
Resolved
PROVIDE OIL POLLUTION PLACARD
Condition: Unknown
Due 18 May 2001
Resolved 25 May 2001