SCOTT TURNER is a 1999 passenger vessel (inspected). The Coast Guard has recorded 38 inspections since 1998, most recently in November 2025, along with 60 deficiencies.

Records from 1998 to 2025. Most recent: inspection, 17 November 2025.

Built
1999
Last inspected
17 November 2025
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

488688
Flag
UNITED STATES
—
Maury page id
psix-488688

Inspections, by type

…with no type recorded4
Years with a record 26 calendar years (1998–2025)
The 38 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it4 - Regulatory (Subpart C or D), Net Ton
4 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 38

17 November 2025 Administrative Inspection · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8249658
21 November 2024 Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8020481
3 August 2023 Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7762139
25 July 2022 Deficiency Check · Administrative Inspection · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7516265
1 November 2021 COI Inspection · Deficiency Check · Administrative Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7343510
28 May 2020 Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6955494
13 February 2020 COI Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6898756
4 October 2018 DAPI Audit · Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6554718
1 May 2018 Hull Examination · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6385241
16 May 2017 Annual Inspection · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6128023
20 October 2016 Administrative Inspection · DAPI Audit · Annual Inspection · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6024861
16 July 2016 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6076911
24 November 2015 Annual Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5770118
23 October 2014 Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5012729
21 July 2012 Type not recorded
No type recorded · Station Crystal River · USCG Southeast District (CGD-SE) · Activity 4386589
15 July 2011 Drydock Exam · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4114290
16 December 2010 Administrative Inspection · COI Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3910391
23 March 2009 Hull Examination · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3439737
11 September 2008 Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3325147
14 March 2008 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3184364
18 September 2007 Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3060340
17 April 2007 Hull Examination · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2909485
24 October 2006 Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2807248
7 April 2006 Simplified Stability Test
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2639819
10 November 2005 COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2531750
22 April 2005 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2339707
29 November 2004 Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2281868
10 November 2003 Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1942585
19 May 2003 Hull Examination · Annual Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1779035
10 October 2002 Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1687123
26 February 2001 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1415554
7 February 2001 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1465009
10 May 2000 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1052101
15 June 1999 Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 815023
28 April 1999 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 792107
16 April 1999 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1446735
11 January 1999 Hull Examination · Plan Review "T" Boat · Initial Certification
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1404675
9 June 1998 Initial Construction-Excluding Oversight
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 794471

Deficiency record · 60

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 3 August 2023 Resolved
A vessel to which this subchapter applies may not be operated without having on board a valid U.S. Coast Guard Certificate of Inspection. Vessel was due for COI inspection on 23FEB23 and has yet to receive a COI inspection. Vessel shall not operate with passengers until new COI has been issued. 46 CFR 176.100
Action required: 17 - Rectify deficiencies prior to departure
Due 3 August 2023
Resolved 9 November 2023
Resolution: Vessel completed COI Inspection 09NOV23.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 8 August 2022 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. Approximately 5 inches of water was found in the STBD aft pontoon chamber. Vessel must remove the water from the chamber. 46CFR177.100
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 August 2022
Resolved 18 August 2022
Resolution: Vessel removed water from the pontoon.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 25 July 2022 Resolved
The owner or managing operator shall make a vessel available for drydock examinations, internal structural examinations, and underwater surveys (UWILD) required by this section. (1) A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Upon administrative inspection vessel was found to be overdue for the DryDock Inspection. Vessel shall not carry passengers until credit DryDock Inspection is completed. 46CFR176.600(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 July 2022
Resolved 8 August 2022
Resolution: Received Credit Dry Dock on this date.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 November 2021 Resolved
Overcurrent protection fuses must be cartridge type UL listed. Identified automotive blade fuses installed for branch circuit protection. 46 CFR 183.380(l)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 December 2021
Resolved 30 November 2021
Resolution: The vessel operator purchased (6) Class T UL Listed 15 amp fuses and a UL Listed class t fuse holder. The blade automotive fuses were removed from the vessel and the new class t fuses were placed into service.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 1 November 2021 Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel has lapsed on its annual inspection. 46 CFR 176.500(b)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 November 2021
Resolved 12 November 2021
Resolution: The operator completed a COI and was issued a Temporary COI for operations.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 February 2020 Resolved
Propulsion machinery must be suitable for propulsion requirements of the hull in which it is installed and capable of operating at a constant marine load. Repair Starboard engine prior to carrying passengers. 46 CFR 182.200(a)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 February 2020
Resolution: Shift linkage on the Starboard engine was replaced by [name withheld]. High quality video Video shows starboard outboard engine starts up and continues to run while testing ahead and astern power.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 October 2018 Resolved
EAP training has not been conducted for crewmembers in a saftey sensitive position. 46CFR16.401
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 October 2018
Resolved 22 October 2018
Resolution: Owner provided a copy of signed EAP training by employees.
01 - Certificates & Documentation › 012 - Crew Certificates › Evidence of Basic Training
Issued 17 October 2018 Resolved
Company drug testing policy read and signed by employees was missing. 46CFR16.401
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 October 2018
Resolved 22 October 2018
Resolution: Owner provided a drug testing policy signed by each employee.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 25 October 2016 Resolved
Repair cracks in boarding ladder. 46CFR176.800
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 October 2016
Resolution: Owner had new ladder buit and installed.
Electrical › Electric Generation Source (service) › Grounding Conductor
Issued 25 October 2016 Resolved
Replace groundwire on fuel tanks. 46CFR182.440
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 October 2016
Resolution: Owner replaced ground wires.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 25 October 2016 Resolved
Install fuel tank mounting strap on stbd fuel tank. 46CFR176.800
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 October 2016
Resolution: Owner fabricated new fuel tank mounting straps for both port and stbd fuel tanks.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 25 October 2016 Resolved
Repair port fuel tank mounting bracket. 46CFR176.800
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 October 2016
Resolution: Owner fabricated new fuel tank mounting straps for both port and stbd fuel tanks.
Engineering › Fuel Oil Service System › Hose
Issued 25 October 2016 Resolved
Replace zip ties on outboard engines with metal hose clamps. 46CFR182.455
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 October 2016
Resolution: Owner replace all zip ties on fuel lines with metel hose clamps.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 20 October 2016 Resolved
Vessel is three months past 90 day mark of anniversary date for its annual inspection. 46CFR176.500(b)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 October 2016
Resolution: Annual inspection commenced.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 24 November 2015 Resolved
Repair cracked welds on embarkation ladder IAW 46 CFR 177.900(b).
Action required: 705 - Other - as specified
Due 24 December 2015
Resolved 14 January 2016
Resolution: Repaired cracked welds.
Lifesaving › Lifeboat Equipment › First Aid Kit
Issued 24 November 2015 Resolved
Obtain ammonia inhalants for the first aid kit IAW 46 CFR 184.710
Action required: 705 - Other - as specified
Due 8 December 2015
Resolved 14 January 2016
Resolution: Obtained ammonia inhalants.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 23 October 2014 Resolved
Vessel does not have a company consortium for their employees. 46 CFR 16.201
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 October 2014
Resolution: Vessel provided consortium with proper employee
Fire Fighting › Fire Bucket › Availability
Issued 23 October 2014 Resolved
Vessel does not have proper fire buckets.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 October 2014
Resolution: Vessel representative bought 02 new fire buckets and clearly labeled them with correct lanyard. All sat.
Documentation › Markings/Placards › Warning Signs
Issued 23 October 2014 Resolved
Vessel does not have their fuel shutoff clearly labeled. 46 CFR 185.608
Action required: 705 - Other - as specified
Due 30 October 2014
Resolved 30 October 2014
Resolution: Labeled correct fuel shutoff
Engineering › Gasoline Engine (propulsion) › Fuel Intake (2 stroke)
Issued 16 December 2010 Resolved
Replace unserviceable fuel tank hoses (Port and STBD) from fuel tanks to filters. 46 CFR 182.720
Due 23 December 2010
Resolved 17 December 2010
Resolution: Hoses replaced with correct type.
Operations/Management › Drills/Instruction › Abandon Ship
Issued 16 December 2010 Resolved
Maintain vessel training log as per 46 CFR 182.720 (e)
Due 23 December 2010
Resolved 17 December 2010
Resolution: Log established.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 16 December 2010 Resolved
Maintain vessel training log as per 46 CFR 182.720
Due 23 December 2010
Resolved 17 December 2010
Resolution: Log established.
Operations/Management › Drills/Instruction › Fire
Issued 16 December 2010 Resolved
Maintain vessel training log as per 46 CFR 182.720
Due 23 December 2010
Resolved 17 December 2010
Resolution: Log established.
Navigation › Collision/Grounding Avoidance › Searchlight
Issued 16 December 2010 Resolved
Provide one additional portable light as per 46 DFR 183.340
Due 23 December 2010
Resolved 17 December 2010
Resolution: Portable light provided.
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 December 2010 Resolved
Replace wire nuts with pressure type connectors as per 46 CFR 183.340.
Due 23 December 2010
Resolved 17 December 2010
Resolution: Wire nuts replaced with pressure type connectors.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 24 October 2006 Resolved
Provide a proper line size and length for ring buoy float light. Line was 1/8 thick and not he proper 3/8" 3 - 6 feet long.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 November 2006
Resolved 27 October 2006
Resolution: The proper size line was renewed on ring buoy float light.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 24 October 2006 Resolved
Label amount of life jackets that are under each seat. They had labeled the size, but not the amount.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 November 2006
Resolved 27 October 2006
Resolution: The proper amount of life jackets were labeled properly under each storage area.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 24 October 2006 Resolved
Remove/cover up old name on life jackets and replace with vessel's name.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 November 2006
Resolved 27 October 2006
Resolution: Life jackets were properly labeled.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 24 October 2006 Resolved
Update first aid kit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 November 2006
Resolved 27 October 2006
Resolution: First aid kit was updated to comply w/ 46 CFR 160.041.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 24 October 2006 Resolved
Provide a work vest w/lanyard for crew member during person OVBD drills.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 November 2006
Resolved 27 October 2006
Resolution: Company provided work vest w/ lanyard.
Engineering › Fuel Oil Service System › Valve
Issued 24 October 2006 Resolved
Label emergency fuel shut off's.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 November 2006
Resolved 27 October 2006
Resolution: Labeled emergency fuel shut off''s.
Operations/Management › Drug and Alcohol Testing
Issued 10 November 2003 Resolved
PROVIDE PROPER DOCUMENTATION OF EMPLOYEE ENROLLMENT. LEGACY COMPONENT DESC: Employee Coverage
Due 24 November 2003
Resolved 24 November 2003
Operations/Management › Drug and Alcohol Testing
Issued 10 November 2003 Resolved
PROVIDE PROPER DOCUMENTATION FOR ANNUAL MIS SUBMISSION. LEGACY COMPONENT DESC: MIS Submission
Due 24 November 2003
Resolved 24 November 2003
Lifesaving › Visual Distress Signals (General)
Issued 10 November 2003 Resolved
MARK WATERTIGHT CONTAINER FOR EMERGENCY DISTRESS SIGNALS AND "DISTRESS SIGNALS" LEGACY COMPONENT DESC: Marking
Due 24 November 2003
Resolved 24 November 2003
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 10 November 2003 Resolved
PROVIDE 1- A-II PORTABLE FIRE EXTINQUISHER AS REQUIRED. LEGACY COMPONENT DESC: Number
Due 24 November 2003
Resolved 24 November 2003
Navigation › Collision/Grounding Avoidance
Issued 10 November 2003 Resolved
PROVIDE PROOF OF PROPERLY WATCHING ANCHOR LIGHT. LEGACY COMPONENT DESC: Navigation Lights
Due 24 November 2003
Resolved 24 November 2003
Engineering › Fuel Oil Storage/Transfer System
Issued 10 November 2003 Resolved
PROVIDE PROPER FITTING FUEL TANK CAP. LEGACY COMPONENT DESC: Tank
Due 24 November 2003
Resolved 24 November 2003
Lifesaving › Lifebuoys
Issued 10 November 2003 Resolved
MARK LIFEBUOY AS REQUIRED WITH VESSEL NAME. LEGACY COMPONENT DESC: Markings (ship name/port)
Due 24 November 2003
Resolved 24 November 2003
Operations/Management › Drug and Alcohol Testing
Issued 19 May 2003 Resolved
Provide current enrollment information for consortium. LEGACY COMPONENT DESC: Employee Coverage
Due 26 May 2003
Resolved 21 May 2003
Operations/Management › Drug and Alcohol Testing
Issued 19 May 2003 Resolved
Provide copy of most recent MIS submission. LEGACY COMPONENT DESC: MIS Submission
Due 26 May 2003
Resolved 28 July 2003
Documentation › Logs/Records › MIS Form
Issued 10 October 2002 Resolved
For DAPI program provide a copy of the latest MIS report/ letter stating it was submitted.
Due 17 October 2002
Resolved 18 October 2002
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 10 October 2002 Resolved
Provide evidence there is an active EAP in effect.
Due 17 October 2002
Resolved 18 October 2002
Documentation › Logs/Records › Logbook (official)
Issued 10 October 2002 Resolved
Provide a current training log book.
Due 17 October 2002
Resolved 18 October 2002
Documentation › Logs/Records › Logbook (official)
Issued 10 October 2002 Resolved
Provide a current lifesaving equioment maintenance log.
Due 17 October 2002
Resolved 18 October 2002
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 10 October 2002 Resolved
Provide a card or pamphlet for a public announcement describing passenger safety orientation.
Due 17 October 2002
Resolved 18 October 2002
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 10 October 2002 Resolved
Provide annual service of portable fire extinguishers.
Due 17 October 2002
Resolved 18 October 2002
Operations/Management › Drills/Instruction › Abandon Ship
Issued 10 October 2002 Resolved
Conduct fire and man overboard drills.
Due 17 October 2002
Resolved 18 October 2002
Unknown
Issued 7 February 2001 Resolved
PRIOR TO OPERATION WITH PASSENGERS, MAKE VESSEL AVAILABLE FOR INSPECTION BYCOGNIZANT OCMI.
Condition: Unknown
Due 7 February 2001
Resolved 7 February 2001
Documentation
Issued 11 January 1999 Resolved
PRIOR TO OPERATING/CARRYING PASSENGERS FOR HIRE, PROVIDE PROOF OF VALID STATE REGISTRATION FOR THIS VESSEL.
Condition: Unknown
Due 11 January 1999
Resolved 11 January 1999
Engineering
Issued 11 January 1999 Resolved
PROVIDE PROOF FROM FUEL TANK MANUFACTURER THAT THE FLAME ARRESTOR INSTALLEDIN THE FUEL VENTS IS 30X30 WIRE MESH. 46CFR182.450
Condition: Unknown
Due 11 January 1999
Resolved 11 January 1999
Unknown
Issued 11 January 1999 Resolved
PRIOR TO OPERATING IN MIAMI AREA OF RESPONSIBILITY, CONTACT MARINE SAFETY OFFICE MIAMI FOR ADDITION OF APPLICABLE ROUTES IN THAT ZONE TO VESSEL'S CERTIFICATE OF INSPECTION.
Condition: Unknown
Due 11 January 1999
Resolved 11 January 1999
Documentation
Issued 11 January 1999 Resolved
PROVIDE VALID FCC RADIO OPERATOR'S AND SHIP'S LICENSE._x001C_ _x001C_ 46CFR184.502
Condition: Unknown
Due 11 January 1999
Resolved 11 January 1999
Lifesaving
Issued 11 January 1999 Resolved
PROVIDE AND POST IN READILY VISIBLE LOCATION THE EMERGENCY BROADCAST PLACARD._x001C_ _x001C_ 46CFR184.506_x001C_
Condition: Unknown
Due 11 January 1999
Resolved 11 January 1999
Navigation
Issued 11 January 1999 Resolved
PROVIDE ADEQUATE CHARTS AND NAVIGATION PUBLICATIONS FOR THE AREA VESSEL IS TO OPERATE. 46CFR184.420_x001C_
Condition: Unknown
Due 11 January 1999
Resolved 11 January 1999
Unknown
Issued 11 January 1999 Resolved
PROVIDE APPROVED CREW TRAINING PROGRAM. 46CFR185.420
Condition: Unknown
Due 11 January 1999
Resolved 11 January 1999
Documentation
Issued 11 January 1999 Resolved
PROVIDE AND POST THE OIL POLLUTION PREVENTION PLACARD. 46CFR184.702
Condition: Unknown
Due 11 January 1999
Resolved 11 January 1999
Documentation
Issued 11 January 1999 Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, PROVIDE EVIDENCE OF VALID OPERATOR'S/MASTER'S LICENSE PER REQUIRED MANNING TO CG MARINE INSPECTOR._x001C_ 46CFR185.402
Condition: Unknown
Due 11 January 1999
Resolved 11 January 1999
Unknown
Issued 11 January 1999 Resolved
POST IN VICINITY OF OPERATING STATION THE EMERGENCY INSTRUCTIONS._x001C_ 46CFR185.510_x001C_
Condition: Unknown
Due 11 January 1999
Resolved 11 January 1999
Lifesaving
Issued 11 January 1999 Resolved
CONDUCT FIRE DRILL AND MAN OVERBOARD DRILLS IN PRESENCE OF A COAST GUARD MARINE INSPECTOR._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 January 1999
Resolved 11 January 1999
Unknown
Issued 11 January 1999 Resolved
PROVIDE APPROVED DRUG TESTING COMPLIANCE INFORMATION. 46CFR16
Condition: Unknown
Due 11 January 1999
Resolved 11 January 1999

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.