Records from 2016 to 2025. Most recent: inspection, 17 November 2025.
Inspection history · 12
17 November 2025
Administrative Inspection · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8249658
21 November 2024
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8020481
3 August 2023
Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7762139
25 July 2022
Deficiency Check · Administrative Inspection · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7516265
1 November 2021
COI Inspection · Deficiency Check · Administrative Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7343510
28 May 2020
Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6955494
13 February 2020
COI Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6898756
4 October 2018
DAPI Audit · Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6554718
1 May 2018
Hull Examination · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6385241
16 May 2017
Annual Inspection · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6128023
20 October 2016
Administrative Inspection · DAPI Audit · Annual Inspection · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6024861
16 July 2016
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6076911
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 3 August 2023
Resolved
A vessel to which this subchapter applies may not be operated without having on board a valid U.S. Coast Guard Certificate of Inspection.
Vessel was due for COI inspection on 23FEB23 and has yet to receive a COI inspection.
Vessel shall not operate with passengers until new COI has been issued.
46 CFR 176.100
Action required: 17 - Rectify deficiencies prior to departure
Due 3 August 2023
Resolved 9 November 2023
Resolution: Vessel completed COI Inspection 09NOV23.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 8 August 2022
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull.
Approximately 5 inches of water was found in the STBD aft pontoon chamber. Vessel must remove the water from the chamber.
46CFR177.100
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 August 2022
Resolved 18 August 2022
Resolution: Vessel removed water from the pontoon.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 25 July 2022
Resolved
The owner or managing operator shall make a vessel
available for drydock examinations, internal structural
examinations, and underwater surveys (UWILD)
required by this section.
(1) A vessel that is exposed to salt water more than
three months in any 12 month period since the last
examination must undergo a drydock examination and
an internal structural at least once every two years.
Upon administrative inspection vessel was found to be
overdue for the DryDock Inspection.
Vessel shall not carry passengers until credit DryDock Inspection is completed.
46CFR176.600(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 July 2022
Resolved 8 August 2022
Resolution: Received Credit Dry Dock on this date.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 November 2021
Resolved
Overcurrent protection fuses must be cartridge type UL listed.
Identified automotive blade fuses installed for branch circuit protection.
46 CFR 183.380(l)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 December 2021
Resolved 30 November 2021
Resolution: The vessel operator purchased (6) Class T UL Listed 15 amp fuses and a UL Listed class t fuse holder. The blade automotive fuses were removed from the vessel and the new class t fuses were placed into service.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 1 November 2021
Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date.
Vessel has lapsed on its annual inspection.
46 CFR 176.500(b)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 November 2021
Resolved 12 November 2021
Resolution: The operator completed a COI and was issued a Temporary COI for operations.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 February 2020
Resolved
Propulsion machinery must be suitable for propulsion requirements of the hull in which it is installed and capable of operating at a constant marine load.
Repair Starboard engine prior to carrying passengers.
46 CFR 182.200(a)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 February 2020
Resolution: Shift linkage on the Starboard engine was replaced by [name withheld]. High quality video Video shows starboard outboard engine starts up and continues to run while testing ahead and astern power.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 October 2018
Resolved
EAP training has not been conducted for crewmembers in a saftey sensitive position. 46CFR16.401
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 October 2018
Resolved 22 October 2018
Resolution: Owner provided a copy of signed EAP training by employees.
01 - Certificates & Documentation › 012 - Crew Certificates › Evidence of Basic Training
Issued 17 October 2018
Resolved
Company drug testing policy read and signed by employees was missing. 46CFR16.401
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 October 2018
Resolved 22 October 2018
Resolution: Owner provided a drug testing policy signed by each employee.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 25 October 2016
Resolved
Repair cracks in boarding ladder. 46CFR176.800
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 October 2016
Resolution: Owner had new ladder buit and installed.
Electrical › Electric Generation Source (service) › Grounding Conductor
Issued 25 October 2016
Resolved
Replace groundwire on fuel tanks. 46CFR182.440
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 October 2016
Resolution: Owner replaced ground wires.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 25 October 2016
Resolved
Install fuel tank mounting strap on stbd fuel tank. 46CFR176.800
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 October 2016
Resolution: Owner fabricated new fuel tank mounting straps for both port and stbd fuel tanks.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 25 October 2016
Resolved
Repair port fuel tank mounting bracket. 46CFR176.800
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 October 2016
Resolution: Owner fabricated new fuel tank mounting straps for both port and stbd fuel tanks.
Engineering › Fuel Oil Service System › Hose
Issued 25 October 2016
Resolved
Replace zip ties on outboard engines with metal hose clamps. 46CFR182.455
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 October 2016
Resolution: Owner replace all zip ties on fuel lines with metel hose clamps.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 20 October 2016
Resolved
Vessel is three months past 90 day mark of anniversary date for its annual inspection. 46CFR176.500(b)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 October 2016
Resolution: Annual inspection commenced.