MAURY USCG vessel records Sign in
← All vessels

SKIPPIN' SUE

SKIPPIN' SUE is a 1976 offshore supply vessel. The Coast Guard has recorded 54 inspections since 1981, most recently in May 2025, along with 35 deficiencies, 2 operational controls and 1 casualty investigation in 2007.

Records from 1981 to 2025. Most recent: inspection, 6 May 2025.

Built
1976
Last inspected
6 May 2025
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDI3915
Flag
UNITED STATES
367062040, 367693260 (licence lapsed)
Maury page id
psix-48875

Inspections, by type

…with no type recorded15
Years with a record 34 calendar years (1981–2025)
The 54 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it99 - Regulatory (Subpart C or D), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDI3915MMSI 367693260 · expired · compulsorily equipped · granted 23 September 2015, cancelled 7 March 2026
WDC6842MMSI 367062040 · expired · compulsorily equipped · granted 13 August 2005, cancelled 17 October 2015
WYH7027MMSI not assigned · expired · voluntarily equipped · granted 29 August 1996, cancelled 9 December 2006
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 54

6 May 2025 Administrative Inspection · Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8129971
14 January 2022 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7385196
5 January 2022 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7376259
5 January 2022 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7376991
4 October 2017 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6281551
26 April 2017 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6132893
15 March 2016 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5833885
8 February 2016 Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5811429
7 February 2011 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3940869
5 March 2010 Internal Structural Exam · Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3690433
30 March 2009 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3426355
4 May 2007 Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2922354
27 April 2007 Examination of Repairs · Damage Survey · In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2916914
21 April 2007 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2937218
15 March 2007 Annual Inspection · Examination of Repairs · Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2891254
22 February 2006 Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2589666
8 June 2005 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2397713
8 June 2005 In-Service Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2397847
22 March 2005 Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2304845
3 March 2004 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2017473
18 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1978070
7 April 2003 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1769484
12 March 2002 Hull Examination · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1493745
2 August 2001 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 213526
22 February 2001 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1445739
24 February 2000 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1381804
11 May 1999 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 214968
25 February 1999 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1418479
13 October 1998 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 766695
15 September 1998 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 201291
6 April 1998 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1433338
24 February 1997 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1439846
26 March 1996 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1360462
17 February 1995 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1449800
12 April 1994 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1442128
30 October 1993 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 121628
12 March 1993 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1379754
16 March 1992 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1011041
15 August 1991 Drydock Extension
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 935326
16 April 1991 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1217650
7 March 1991 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1238216
8 March 1990 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 918768
27 July 1989 Drydock Extension
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1345676
8 March 1989 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1204160
11 March 1988 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1337976
5 August 1987 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1030379
10 March 1987 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1015664
14 March 1986 COI Inspection · Credit Drydock
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1310846
9 July 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1299084
29 March 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 983536
30 March 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1280444
7 April 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 969613
8 April 1982 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1273524
16 April 1981 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1276034

Deficiency record · 35

10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 5 January 2022 Resolved
A COTP Order was issued to the vessel prohibiting movement until certain requirements were met. The Captain departed the dock with the vessel without meeting all of the requirements in violation of the COTP Order.
Condition: Placed in Improper Service
Action required: 60 - Rectify deficiencies prior to movement
Resolved 13 January 2022
Resolution: Issued a LOW to the Captain for the alleged violation of the COTP Order.
Lifesaving › Lifebuoys › Serviceable
Issued 8 February 2016 Resolved
Stbd ring bouy manufacture plug deteroriated and has water inside body. Needs retroreflective material on ring.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 February 2016
Resolved 8 February 2016
Resolution: Life ring replaced during inspection.
Communications › Radio Communications › EPIRB
Issued 8 February 2016 Resolved
Antenna has broken insulation and 1 inch of conductor showing through in two places.
Condition: Improper/Lack of Maintenance
Due 8 February 2016
Resolved 8 February 2016
Resolution: New antenna installed during inspection.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 8 February 2016 Resolved
Stbd and "all around" masthead lights inop.
Due 8 February 2016
Resolved 8 February 2016
Resolution: New bulbs fitted, running lights sat.
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 8 February 2016 Resolved
Fuel tank gooseneck vents (all four of four) have the flame screen sealed in with fire block type silicone. Vsl will attach flame screen with hose clamp and plan to submit pictures.
Condition: Improper Installation
Due 19 February 2016
Resolved 18 February 2016
Resolution: Vsl rep submitted correction and photos in 18 FEB email to lead inspector. "Attached is pictures of fuel vents and fire (flame) screen installed on vsl."
Fire Fighting › Fire Hoses › Condition
Issued 15 March 2007 Resolved
One length of hose was worn.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 April 2007
Resolution: Corrected on the spot.
Documentation › Logs/Records › Logbook (official)
Issued 15 March 2007 Resolved
Fire fighting, manoverboard and abandon ship drills were not being recorded properly.
Action required: 705 - Other - as specified
Resolved 4 April 2007
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 22 February 2006 Resolved
REPLACE 20 LIFE JACKETS PRIOR TO SAILING.
Action required: 17 - Rectify deficiencies prior to departure
Due 22 March 2006
Resolved 28 February 2006
Resolution: PROVIDED PROPER NUMBER AND TYPE OF LIFE JACKETS.
Documentation › Certificates/Documents › Dedicated Clean Ballast Tanks Amending Letter
Issued 22 February 2006 Resolved
PROVIDE BALLAST WATER MANAGEMENT PLAN PRIOR TO 22MAR2006
Action required: 705 - Other - as specified
Due 22 March 2006
Resolved 28 February 2006
Resolution: PROVIDED APPROVED PLAN
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 8 June 2005 Resolved
Provide proper manning as required by COI prior to operation. Vsl running short one mate.
Condition: Placed in Improper Service
Due 8 June 2005
Resolved 8 June 2005
Resolution: Provided
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 8 June 2005 Resolved
Vsl found overloaded beyond max draft. Provided review of stability ltr with master.
Condition: Placed in Improper Service
Due 8 June 2005
Resolved 8 June 2005
Resolution: Master offloaded rig water to meet max draft requirements per stability ltr.
Engineering › Bilge Water Management System › Valve
Issued 3 March 2004 Resolved
The #2 bilge pipe valve, at the manifold, needs repacking.
Action required: 705 - Other - as specified
Due 3 April 2004
Resolved 3 March 2004
Resolution: Repacked valve.
Electrical › Electrical Distribution System (service)
Issued 3 March 2004 Resolved
Renew/repair latch on distribution panel in the engine room. The panel door could not close properly. LEGACY COMPONENT DESC: Panel board
Action required: 705 - Other - as specified
Due 3 April 2004
Resolved 3 March 2004
Resolution: Latch repaired.
Electrical › Lighting (emergency)
Issued 3 March 2004 Resolved
Provide proper emergency light in aft accommodation space. LEGACY COMPONENT DESC: Lighting Fixture
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 March 2004
Resolution: Emergency light installed.
Deck/Cargo › Vapor Control Systems
Issued 3 March 2004 Resolved
Provide proper flame screens in starboard side gooseneck fuel tank vent and port side lube oil vent. LEGACY COMPONENT DESC: Flame Screens
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 March 2004
Resolution: Proper flame screens installed.
Accommodation/Occupational Safety › Medical/First Aid
Issued 3 March 2004 Resolved
Several first aid items were expired. LEGACY COMPONENT DESC: First Aid Kit
Action required: 705 - Other - as specified
Due 3 April 2004
Resolved 3 March 2004
Resolution: New first aid kit provided.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 3 March 2004 Resolved
No label indicating emergency escape route on the pilot house side of escape hatch.
Action required: 705 - Other - as specified
Due 3 April 2004
Resolved 3 March 2004
Resolution: Proper labelling stencilled on deck.
Engineering › Bilge Water Management System › Piping
Issued 3 March 2004 Resolved
Reach rod to forepeak bilge valve was not connected.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 March 2004
Resolution: Reach rod repaired.
Construction/Loadline › Structures › Door
Issued 3 March 2004 Resolved
The watertight door to the mess deck would not secure properly.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 March 2004
Resolution: Dogs adjusted allowing the door to secure properly.
Communications › Radio Communications › EPIRB
Issued 3 March 2004 Resolved
Hydrostatic release for the EPIRB was expired.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 March 2004
Resolution: New hydrostatic release provided.
Lifesaving › Buoyant Apparatus
Issued 3 March 2004 Resolved
Provide water light lines of proper size and length for life floats and life ring buoys. LEGACY COMPONENT DESC: Water light Lines
Action required: 705 - Other - as specified
Due 3 April 2004
Resolved 3 March 2004
Resolution: Proper waterlight lines installed.
Navigation › Piloting/Steering
Issued 3 March 2004 Resolved
Provide current Tide Tables, Current Tables, Coast Pilot, and Light List. LEGACY COMPONENT DESC: Navigational Publications (general)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 March 2004
Resolution: Up-to-date navigational publications provided.
Operations/Management › Drills/Instruction › Abandon Ship
Issued 3 March 2004 Resolved
No abandon ship or man overboard drills had been logged in approximately one year.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 March 2005
Resolved 22 March 2005
Resolution: Drills have been logged.
Stability › Watertight Integrity
Issued 7 April 2003 Resolved
Adjust for proper closure LEGACY COMPONENT DESC: Escape Hatch
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 April 2003
Resolution: E/R escape hatch was adjusted prior to completion of inspection.
Lifesaving › Buoyant Apparatus
Issued 7 April 2003 Resolved
1 of 2 life floats was no longer in servicable condition. LEGACY COMPONENT DESC: Non Serviciable
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 April 2003
Resolution: Life float was replaced from owners on hand stock.
Communications › Internal Communications System
Issued 12 March 2002 Resolved
NO PUBLIC ADDRESS SYSTEM INSTALLED THROUGHOUT ACCOMODATION SPACES. LEGACY COMPONENT DESC: PUBLIC ADDRESS
Due 12 March 2002
Resolved 12 March 2002
Electrical › Electric Generation Source (service) › Switch
Issued 12 March 2002 Resolved
MISSING MAIN ENGINE STOPS AT PILOTHOUSE CONTROL STATION.
Due 12 March 2002
Resolved 12 March 2002
Stability › Watertight Integrity
Issued 12 March 2002 Resolved
WATERTIGHT DOORS NOT STENCILED. LEGACY COMPONENT DESC: DOORS
Due 12 March 2002
Resolved 12 March 2002
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 12 March 2002 Resolved
NO FIXED FIRE FIGHTING SYSTEM INSTALLED ON PAINT LOCKER. LEGACY COMPONENT DESC: PAINT LOCKER
Due 12 March 2002
Resolved 12 March 2002
Engineering › Shafting/Propeller Arrangements
Issued 12 March 2002 Resolved
MAIN ENGINES OUT OF ALIGNMENT. LEGACY COMPONENT DESC: ALIGNMENT
Action required: 17 - Rectify deficiencies prior to departure
Due 12 March 2002
Resolved 12 March 2002
Electrical
Issued 22 February 2001 Resolved
PROVIDE EMERGENCY LIGHTING FOR ENGINE ROOM ESCAPE AS WELL AS FWD BERTHING COMPARTMENT EXIT.
Condition: Unknown
Due 22 February 2001
Resolved 22 February 2001
Construction/Loadline
Issued 22 February 2001 Resolved
INSTALL HIGL LEVEL ALARM FOR RUDDER COMPARTMENT. ALSO PROVIDE VISUAL ALARM AT OPERATING STATION.
Condition: Unknown
Due 22 February 2001
Resolved 22 February 2001
Unknown
Issued 25 February 1999 Resolved
INSTALL RESCUE PLATFORM IN ACCORDANCE WITH DISTRICT EIGHT POLICY DATED 12 NOVEMBER 1998.
Condition: Unknown
Due 16 March 1999
Resolved 16 March 1999
Unknown
Issued 8 April 1982 Resolved
MAKE PERMANENT REPAIRS TO THE BOTTOM ANGLE AND BRACKET NEAR THE STARBOARD RUDDER STOCK COLUMN IN THE STERN LAZARETTE.
Condition: Unknown
Due 8 April 1982
Resolved 8 April 1982
Unknown
Issued 8 April 1982 Resolved
REPLACE THE ANCHOR CABLE IN KIND.
Condition: Unknown
Due 8 April 1982
Resolved 8 April 1982

Casualty record · 1

21 April 2007Routine · role: Involved in a Marine Casualty · activity 2937218
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.