← All vessels
SKIPPIN' SUE
SKIPPIN' SUE is a 1976 offshore supply vessel. The Coast Guard has recorded 54 inspections since 1981, most recently in May 2025, along with 35 deficiencies, 2 operational controls and 1 casualty investigation in 2007.
Records from 1981 to 2025. Most recent: inspection, 6 May 2025.
- Built
- 1976
- Last inspected
- 6 May 2025
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 35 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2007
Identity
576513
WDI3915
48875
Flag
UNITED STATES
367062040, 367693260 (licence lapsed)
Maury page id
psix-48875
Inspections, by type
…with no type recorded15
Years with a record
34 calendar years (1981–2025)
The 54 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.
Documentation record
Tonnage as PSIX records it99 - Regulatory (Subpart C or D), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
67 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
WDI3915MMSI 367693260 · expired · compulsorily equipped · granted 23 September 2015, cancelled 7 March 2026
WDC6842MMSI 367062040 · expired · compulsorily equipped · granted 13 August 2005, cancelled 17 October 2015
WYH7027MMSI not assigned · expired · voluntarily equipped · granted 29 August 1996, cancelled 9 December 2006
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 54
6 May 2025
Administrative Inspection · Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8129971
14 January 2022
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7385196
5 January 2022
Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7376259
5 January 2022
Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7376991
4 October 2017
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6281551
26 April 2017
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6132893
15 March 2016
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5833885
8 February 2016
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5811429
7 February 2011
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3940869
5 March 2010
Internal Structural Exam · Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3690433
30 March 2009
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3426355
4 May 2007
Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2922354
27 April 2007
Examination of Repairs · Damage Survey · In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2916914
21 April 2007
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2937218
15 March 2007
Annual Inspection · Examination of Repairs · Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2891254
22 February 2006
Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2589666
8 June 2005
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2397713
8 June 2005
In-Service Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2397847
22 March 2005
Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2304845
3 March 2004
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2017473
18 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1978070
7 April 2003
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1769484
12 March 2002
Hull Examination · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1493745
2 August 2001
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 213526
22 February 2001
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1445739
24 February 2000
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1381804
11 May 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 214968
25 February 1999
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1418479
13 October 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 766695
15 September 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 201291
6 April 1998
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1433338
24 February 1997
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1439846
26 March 1996
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1360462
17 February 1995
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1449800
12 April 1994
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1442128
30 October 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 121628
12 March 1993
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1379754
16 March 1992
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1011041
15 August 1991
Drydock Extension
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 935326
16 April 1991
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1217650
7 March 1991
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1238216
8 March 1990
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 918768
27 July 1989
Drydock Extension
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1345676
8 March 1989
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1204160
11 March 1988
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1337976
5 August 1987
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1030379
10 March 1987
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1015664
14 March 1986
COI Inspection · Credit Drydock
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1310846
9 July 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1299084
29 March 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 983536
30 March 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1280444
7 April 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 969613
8 April 1982
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1273524
16 April 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1276034
Deficiency record · 35
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 5 January 2022
Resolved
A COTP Order was issued to the vessel prohibiting movement until certain requirements were met. The Captain departed the dock with the vessel without meeting all of the requirements in violation of the COTP Order.
Lifesaving › Lifebuoys › Serviceable
Issued 8 February 2016
Resolved
Stbd ring bouy manufacture plug deteroriated and has water inside body. Needs retroreflective material on ring.
Communications › Radio Communications › EPIRB
Issued 8 February 2016
Resolved
Antenna has broken insulation and 1 inch of conductor showing through in two places.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 8 February 2016
Resolved
Stbd and "all around" masthead lights inop.
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 8 February 2016
Resolved
Fuel tank gooseneck vents (all four of four) have the flame screen sealed in with fire block type silicone. Vsl will attach flame screen with hose clamp and plan to submit pictures.
Fire Fighting › Fire Hoses › Condition
Issued 15 March 2007
Resolved
One length of hose was worn.
Documentation › Logs/Records › Logbook (official)
Issued 15 March 2007
Resolved
Fire fighting, manoverboard and abandon ship drills were not being recorded properly.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 22 February 2006
Resolved
REPLACE 20 LIFE JACKETS PRIOR TO SAILING.
Documentation › Certificates/Documents › Dedicated Clean Ballast Tanks Amending Letter
Issued 22 February 2006
Resolved
PROVIDE BALLAST WATER MANAGEMENT PLAN PRIOR TO 22MAR2006
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 8 June 2005
Resolved
Provide proper manning as required by COI prior to operation. Vsl running short one mate.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 8 June 2005
Resolved
Vsl found overloaded beyond max draft. Provided review of stability ltr with master.
Engineering › Bilge Water Management System › Valve
Issued 3 March 2004
Resolved
The #2 bilge pipe valve, at the manifold, needs repacking.
Electrical › Electrical Distribution System (service)
Issued 3 March 2004
Resolved
Renew/repair latch on distribution panel in the engine room. The panel door could not close properly. LEGACY COMPONENT DESC: Panel board
Electrical › Lighting (emergency)
Issued 3 March 2004
Resolved
Provide proper emergency light in aft accommodation space. LEGACY COMPONENT DESC: Lighting Fixture
Deck/Cargo › Vapor Control Systems
Issued 3 March 2004
Resolved
Provide proper flame screens in starboard side gooseneck fuel tank vent and port side lube oil vent. LEGACY COMPONENT DESC: Flame Screens
Accommodation/Occupational Safety › Medical/First Aid
Issued 3 March 2004
Resolved
Several first aid items were expired. LEGACY COMPONENT DESC: First Aid Kit
Fire Fighting › Means of Escape › Escape Route Signs
Issued 3 March 2004
Resolved
No label indicating emergency escape route on the pilot house side of escape hatch.
Engineering › Bilge Water Management System › Piping
Issued 3 March 2004
Resolved
Reach rod to forepeak bilge valve was not connected.
Construction/Loadline › Structures › Door
Issued 3 March 2004
Resolved
The watertight door to the mess deck would not secure properly.
Communications › Radio Communications › EPIRB
Issued 3 March 2004
Resolved
Hydrostatic release for the EPIRB was expired.
Lifesaving › Buoyant Apparatus
Issued 3 March 2004
Resolved
Provide water light lines of proper size and length for life floats and life ring buoys. LEGACY COMPONENT DESC: Water light Lines
Navigation › Piloting/Steering
Issued 3 March 2004
Resolved
Provide current Tide Tables, Current Tables, Coast Pilot, and Light List. LEGACY COMPONENT DESC: Navigational Publications (general)
Operations/Management › Drills/Instruction › Abandon Ship
Issued 3 March 2004
Resolved
No abandon ship or man overboard drills had been logged in approximately one year.
Stability › Watertight Integrity
Issued 7 April 2003
Resolved
Adjust for proper closure LEGACY COMPONENT DESC: Escape Hatch
Lifesaving › Buoyant Apparatus
Issued 7 April 2003
Resolved
1 of 2 life floats was no longer in servicable condition. LEGACY COMPONENT DESC: Non Serviciable
Communications › Internal Communications System
Issued 12 March 2002
Resolved
NO PUBLIC ADDRESS SYSTEM INSTALLED THROUGHOUT ACCOMODATION SPACES. LEGACY COMPONENT DESC: PUBLIC ADDRESS
Electrical › Electric Generation Source (service) › Switch
Issued 12 March 2002
Resolved
MISSING MAIN ENGINE STOPS AT PILOTHOUSE CONTROL STATION.
Stability › Watertight Integrity
Issued 12 March 2002
Resolved
WATERTIGHT DOORS NOT STENCILED. LEGACY COMPONENT DESC: DOORS
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 12 March 2002
Resolved
NO FIXED FIRE FIGHTING SYSTEM INSTALLED ON PAINT LOCKER. LEGACY COMPONENT DESC: PAINT LOCKER
Engineering › Shafting/Propeller Arrangements
Issued 12 March 2002
Resolved
MAIN ENGINES OUT OF ALIGNMENT. LEGACY COMPONENT DESC: ALIGNMENT
Electrical
Issued 22 February 2001
Resolved
PROVIDE EMERGENCY LIGHTING FOR ENGINE ROOM ESCAPE AS WELL AS FWD BERTHING COMPARTMENT EXIT.
Construction/Loadline
Issued 22 February 2001
Resolved
INSTALL HIGL LEVEL ALARM FOR RUDDER COMPARTMENT. ALSO PROVIDE VISUAL ALARM AT OPERATING STATION.
Unknown
Issued 25 February 1999
Resolved
INSTALL RESCUE PLATFORM IN ACCORDANCE WITH DISTRICT EIGHT POLICY DATED 12 NOVEMBER 1998.
Unknown
Issued 8 April 1982
Resolved
MAKE PERMANENT REPAIRS TO THE BOTTOM ANGLE AND BRACKET NEAR THE STARBOARD RUDDER STOCK COLUMN IN THE STERN LAZARETTE.
Unknown
Issued 8 April 1982
Resolved
REPLACE THE ANCHOR CABLE IN KIND.
Casualty record · 1
21 April 2007Routine · role: Involved in a Marine Casualty · activity 2937218
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.