MAURY USCG vessel records Sign in
← All vessels

CONCEPTION

CONCEPTION is a 1976 offshore supply vessel. The Coast Guard has recorded 56 inspections since 1982, most recently in October 2004, along with 51 deficiencies.

Records from 1982 to 2004. Most recent: inspection, 5 October 2004.

Built
1976
Last inspected
5 October 2004
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7621815 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WCW5539
Flag
UNITED STATES
338405000 (licence lapsed)
Maury page id
psix-48885

Inspections, by type

…with no type recorded21
Years with a record 20 calendar years (1982–2004)
The 56 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 22 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it305 - Regulatory (Subpart C or D), Gross Ton
718 - Convention (Subpart B), Gross Ton
207 - Regulatory (Subpart C or D), Net Ton
215 - Convention (Subpart B), Net Ton
858 - Dead Weight, Ton
719 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WCW5539MMSI 338405000 · cancelled · compulsorily equipped · granted 16 September 1998, cancelled 13 March 2006
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 56

5 October 2004 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2214159
31 May 2001 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1065884
12 April 2001 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1061741
16 June 2000 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1054359
10 May 2000 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1424916
30 April 1999 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1127620
30 April 1999 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1130212
12 June 1998 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1473185
5 June 1998 Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 793192
28 April 1998 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 789857
28 January 1998 Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1408041
30 August 1997 Excursion Permit
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 785179
2 May 1997 COI Inspection · Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1457445
24 June 1996 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 760527
23 June 1996 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 203268
23 June 1996 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 226350
10 May 1996 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1414665
13 June 1995 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 876813
3 May 1995 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1450973
18 April 1995 Inclining Experiment
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1374255
8 June 1994 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1473263
21 September 1993 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1438099
20 May 1993 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 112985
20 May 1993 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 170955
20 May 1993 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 676768
3 April 1993 Examination of Repairs · Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1146144
1 April 1993 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 179758
11 January 1993 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1382514
23 July 1992 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1410743
10 June 1992 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 646668
8 June 1992 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 103296
21 November 1991 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 937187
4 September 1991 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 940408
28 January 1991 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1227476
28 August 1990 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 921296
1 August 1990 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1215929
25 June 1990 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1242106
13 January 1990 Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 916828
9 January 1990 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1233637
5 September 1989 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 892709
4 August 1988 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1344587
22 April 1988 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1195217
7 April 1988 Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1036711
16 October 1987 Re-Inspection · Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1018841
14 July 1987 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1017133
2 May 1987 Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1334000
23 April 1987 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1315392
12 February 1987 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1017011
5 August 1986 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1321528
23 October 1985 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1303490
19 December 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 977898
10 August 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 978999
3 May 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1280417
4 April 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1280240
20 March 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 972475
8 September 1982 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1275303

Deficiency record · 51

Fire Fighting
Issued 2 May 1997 Resolved
REPAIR/REPLACE #5 FIRE STATION HANDLE.
Condition: Unknown
Due 2 May 1997
Resolved 20 May 1997
Electrical
Issued 2 May 1997 Resolved
MAKE REPAIRS TO WIRING ON FWD MAST HEAD LIGHTING.
Condition: Unknown
Due 2 May 1997
Resolved 20 May 1997
Electrical
Issued 2 May 1997 Resolved
REPAIR BOAT DECK LIGHT.
Condition: Unknown
Due 13 May 1997
Resolved 20 May 1997
Fire Fighting
Issued 2 May 1997 Resolved
PROVE PROPER OPERATION OF FIRE MONITOR.
Condition: Unknown
Due 2 May 1997
Resolved 20 May 1997
Construction/Loadline
Issued 2 May 1997 Resolved
REPAIR LEAK AND LABEL MANIFOLD BILGE PUMP.
Condition: Unknown
Due 13 May 1997
Resolved 20 May 1997
Engineering
Issued 2 May 1997 Resolved
LABEL ALL FUEL CUTOFFS IN ENGINE ROOM AND RECONNECT OUTSIDE E/R.
Condition: Unknown
Due 13 May 1997
Resolved 20 May 1997
Engineering
Issued 2 May 1997 Resolved
REMOVE OR REPAIR OLD FUEL REACH ROD SHUTOFFS ON MAINDECK.
Condition: Unknown
Due 2 May 1997
Resolved 20 May 1997
Engineering
Issued 2 May 1997 Resolved
REPLACE/REPAIR PORT P/V RELIEF VALVE.
Condition: Unknown
Due 2 May 1997
Resolved 20 May 1997
Engineering
Issued 2 May 1997 Resolved
OPEN/CLEAN AND PROVIDE FOR INSPECTION OF BOTH AIR RECEIVERS.
Condition: Unknown
Due 13 May 1997
Resolved 20 May 1997
Construction/Loadline
Issued 2 May 1997 Resolved
PROPERLY INSTALL GASKET IN WATERTIGHT DOOR LEADING INTO ENGINE ROOM.
Condition: Unknown
Due 2 May 1997
Resolved 20 May 1997
Construction/Loadline
Issued 2 May 1997 Resolved
REPAINT FWD DRAFT MARKS.
Condition: Unknown
Due 2 May 1997
Resolved 20 May 1997
Fire Fighting
Issued 2 May 1997 Resolved
RE-CHARGE SCBA BOTTLE.
Condition: Unknown
Due 13 May 1997
Resolved 20 May 1997
Electrical
Issued 2 May 1997 Resolved
REMOVE DEAD END WIRES FROM ENGINEERING SPACES.
Condition: Unknown
Due 2 May 1997
Resolved 20 May 1997
Accommodation/Occupational Safety
Issued 2 May 1997 Resolved
SECURE LOOSE DECK BOARDS IN E/R PASSAGEWAY AND DECK PLATES IN ENGINEROOM.
Condition: Unknown
Due 13 May 1997
Resolved 20 May 1997
Accommodation/Occupational Safety
Issued 2 May 1997 Resolved
PERMANMENTLY INSTALL HOT WATER HEATER TANK, LOCATED IN ENGINE ROOM PASSAGEWAY.
Condition: Unknown
Due 2 May 1997
Resolved 20 May 1997
Engineering
Issued 2 May 1997 Resolved
INSTALL GUARDS ON SIGHT GLASSES FOR EXPANSION TANKS.
Condition: Unknown
Due 13 May 1997
Resolved 20 May 1997
Electrical
Issued 2 May 1997 Resolved
PROPERLY LABEL ALL INDICATORS ON ALARM PANELS.
Condition: Unknown
Due 20 May 1997
Resolved 20 May 1997
Electrical
Issued 2 May 1997 Resolved
INSTALL GROUND DETECTION LIGHTS ON #2 MAIN BUS SWITCH BOARD.
Condition: Unknown
Due 20 May 1997
Resolved 20 May 1997
Deck/Cargo
Issued 2 May 1997 Resolved
PROVE PROPER OPERATION PORT ANCHOR RELEASE AND WINDLESS.
Condition: Unknown
Due 13 May 1997
Resolved 20 May 1997
Engineering
Issued 2 May 1997 Resolved
REPAIR/REPLACE OR REMOVE S/S GENERATOR STOP CONTROLS FROM NAVIGATION BRIDGE.
Condition: Unknown
Due 2 May 1997
Resolved 20 May 1997
Engineering
Issued 2 May 1997 Resolved
DEMONSTRATE PROPER OPERATION OD MDE REMOTE SHUTDOWNS FROM NAVIGATION BRIDGE.
Condition: Unknown
Due 2 May 1997
Resolved 20 May 1997
Electrical
Issued 2 May 1997 Resolved
PROPERLY SECURE WIRING ON ALL INSTRUMENT PANELS.
Condition: Unknown
Due 2 May 1997
Resolved 20 May 1997
Engineering
Issued 2 May 1997 Resolved
DOUBLE NUT STBD SHAFT PACKING RING.
Condition: Unknown
Due 13 May 1997
Resolved 20 May 1997
Engineering
Issued 2 May 1997 Resolved
PROPERLY INSTALL BOTH MDE STARTER OIL FILLS.
Condition: Unknown
Due 13 May 1997
Resolved 20 May 1997
Electrical
Issued 2 May 1997 Resolved
ENSURE PROPER OPERATION/ILLUMINATION OF ALL EMERGENCY LIGHTING IN ENG ROOM.
Condition: Unknown
Due 20 May 1997
Resolved 20 May 1997
Electrical
Issued 10 May 1996 Resolved
PROVE PROPER OPERATION OF AFT GENERATOR OVERSPEED TRIPPING MECHANISM.
Condition: Unknown
Due 13 May 1996
Resolved 8 August 1996
Accommodation/Occupational Safety
Issued 10 May 1996 Resolved
PROVE PROPER OPERATION OF STARTING AIR RECIEVERS' (P&S) SAFETY PRESSURE RELIEF VALVES AND ASSOCIATED GUAGES.
Condition: Unknown
Due 13 May 1996
Resolved 8 August 1996
Documentation
Issued 3 May 1995 Resolved
A PERMANENT STABILITY LETTER IS TO BE PLACED ON BOARD BASED ON THE INCLINE CONDUCTED 18APR95.
Condition: Unknown
Due 3 May 1995
Resolved 3 May 1995
Deck/Cargo
Issued 3 May 1995 Resolved
PLANS APPROVED BY THE MSC ARE TO BE PROVIDED FOR THE ALTERATIONS COMPLETED TO THE LIQUID MUD TANKS IN APRIL 1995.
Condition: Unknown
Due 3 May 1995
Resolved 3 May 1995
Electrical
Issued 1 August 1990 Resolved
REPAIR AND REMOUNT DOOR TO AIR CONDITIONER COMPRESSOR MOTOR CONTROLLER LOCATED IN STARBOARD DECK STORES SPACE.
Condition: Unknown
Due 1 August 1990
Resolved 1 August 1990
Construction/Loadline
Issued 1 August 1990 Resolved
INSTALL SUITABLE GASKETS IN COVERS FOR ENGINEROOM POWERED EXHAUST VENTS.
Condition: Unknown
Due 1 August 1990
Resolved 1 August 1990
Engineering
Issued 1 August 1990 Resolved
PROVIDE MEANS OF OPERATIONALLY TESTING BOTH AIR RECEIVER RELIEF VALVES OR REPLACE WITH RELIEF VALVES SET AT LESS THAN MAXIMUM AIR COMPRESSOR DISCHARGE PRESSURE OF 200 PSI AND OPERATIONALLY TEST.
Condition: Unknown
Due 1 August 1990
Resolved 1 August 1990
Documentation
Issued 1 August 1990 Resolved
PROPERLY MARK LOAD LINE DECK REFERENCE MARK.
Condition: Unknown
Due 1 August 1990
Resolved 1 August 1990
Navigation
Issued 1 August 1990 Resolved
MAKE PERMANENT REPAIRS TO FRACTURED WELDS AT GUSSETS REINFORCING THE UPPER RUDDER POST GUIDES.
Condition: Unknown
Due 1 August 1990
Resolved 1 August 1990
Electrical
Issued 1 August 1990 Resolved
REMOVE DEADEND WIRES AT NUMEROUS LOCATIONS THROUGHOUT VESSEL.
Condition: Unknown
Due 1 August 1990
Resolved 1 August 1990
Navigation
Issued 5 September 1989 Resolved
CALIBRATE RUDDER ANGLE INDICATOR FOR FORWARD AND AFT WHEELHOUSE STEERING STATIONS.
Condition: Unknown
Due 5 September 1989
Resolved 5 September 1989
Navigation
Issued 5 September 1989 Resolved
PREPARE MAGNETIC STEERING COMPASS CORRECTION CARD.
Condition: Unknown
Due 5 September 1989
Resolved 5 September 1989
Construction/Loadline
Issued 5 September 1989 Resolved
MAKE PERMANENT REPAIRS TO FRACTURE IN WAY OF MAIN DECK AND SIDESHELL OF PORT BALLAST TANK (FR54) AT THE NEXT GAS FREEING BUT NOT LATER THAN 10 FEB 90.
Condition: Unknown
Due 5 September 1989
Resolved 5 September 1989
Electrical
Issued 5 September 1989 Resolved
RENEW DIRECTORY FOR ENGINE ROOM LIGHTING PANEL.
Condition: Unknown
Due 5 September 1989
Resolved 5 September 1989
Unknown
Issued 20 March 1984 Resolved
THE FOLLOWING DEFICIENCIES ARE FOR THE POINT CONCEPTION, DN576825.
Condition: Unknown
Due 20 March 1984
Resolved 20 March 1984
Construction/Loadline
Issued 20 March 1984 Resolved
ENSURE PROPER OPERATION OF ALL REACH RODS AND LABEL THEIR FUNCTION ALONG- SIDE.
Condition: Unknown
Due 20 March 1984
Resolved 20 March 1984
Navigation
Issued 20 March 1984 Resolved
MAKE PERMANENT REPAIRS TO EXISTING HYDRAULIC LINES STARBOARD SIDE, RUDDER COMPARTMENT.
Condition: Unknown
Due 20 March 1984
Resolved 20 March 1984
Electrical
Issued 20 March 1984 Resolved
RENEW SWITCH FOR BILGE PUMP.
Condition: Unknown
Due 20 March 1984
Resolved 20 March 1984
Construction/Loadline
Issued 20 March 1984 Resolved
INSTALL THE PROPER SIZE GASKET FOR THE WATERTIGHT DOORS TO THE ENGINE ROOM TO ENSURE WATRTIGHT INTEGRITY.
Condition: Unknown
Due 20 March 1984
Resolved 20 March 1984
Construction/Loadline
Issued 20 March 1984 Resolved
AT NEXT DRYDOCK EXAMINATION CROP AND RENEW THE THREE AFTERMOST SIDESHELL AND UNDERDECK LONGITUDIALS IN THE CHAIN LOCKER PORT SIDE.
Condition: Unknown
Due 20 March 1984
Resolved 20 March 1984
Documentation
Issued 20 March 1984 Resolved
RENEW THE VESSEL'S CERTIFICATE OF DOCUMENTION.
Condition: Unknown
Due 20 March 1984
Resolved 20 March 1984
Unknown
Issued 20 March 1984 Resolved
RENEW THE FLAME SCREENS FOR THE FUEL OIL TANK VENTS (USING 1 EACH 30 X 30 MESH OR 2 EACH 20 X 20 MESH).
Condition: Unknown
Due 31 March 1984
Resolved 20 March 1984
Navigation
Issued 20 March 1984 Resolved
MAKE PERMANENT REPAIRS IN WAY OF TEMPORARY REPAIR ON NON-FOLLOW UP STEERINGSYSTEM.
Condition: Unknown
Due 20 March 1984
Resolved 20 March 1984
Electrical
Issued 20 March 1984 Resolved
INSTALL PROTECTIVE GLOBES AND CAGES ON ALL LIGHTS WITHOUT THEM.
Condition: Unknown
Due 31 March 1984
Resolved 20 March 1984
Navigation
Issued 20 March 1984 Resolved
AT NEXT DRYDOCK EXAMINATION REWELD THE BRACES FOR THE STARBOARD RUDDER SUPPORT.
Condition: Unknown
Due 31 August 1984
Resolved 20 March 1984
Construction/Loadline
Issued 20 March 1984 Resolved
MAKE NECESSARY REPAIRS TO THE PORT AND STARBOARD ENGINE ROOM HATCHWAYS TO ENSURE THE WATERTIGHT INTEGRITY.
Condition: Unknown
Due 31 March 1984
Resolved 20 March 1984

Ownership record