Records from 2009 to 2025. Most recent: inspection, 14 July 2025.
Everything above is free. The detail below — the inspection history, the deficiency record, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 12
14 July 2025
Annual Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 8182267
16 July 2024
Annual Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7959325
24 March 2023
COI Inspection · Hull Examination · Administrative Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7659301
24 June 2022
Internal Structural Exam · Deficiency Check · Annual Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7485916
25 May 2021
Deficiency Check · Annual Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7206023
25 June 2020
Simplified Stability Test
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6987444
25 June 2020
Annual Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6987458
24 February 2020
Liferaft Servicing
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6914727
11 June 2019
Deficiency Check · Annual Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6710915
19 April 2018
Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6398055
8 January 2018
Drydock Exam · Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6336444
13 April 2016
Internal Structural Exam · Hull Examination
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 5852841
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 June 2022
Resolved
Renew cooling hose on port engine and transmission fluid hose.
CITE: 46 CFR 182.425
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 14 August 2022
Resolution: Received photo of newly installed hoses
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 24 June 2022
Resolved
Change cracked battery terminal connection on port aft battery.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 14 August 2022
Resolution: Recieved photo of newly installed battery posts.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 June 2022
Resolved
Place guards on alternator port and starboard.
CITE: 46 CFR 182.200
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 14 August 2022
Resolution: Recieved photo of guards installed
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 24 June 2022
Resolved
Renew line on lazarette hatch.
CITE: 176.360(b)(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 14 August 2022
Resolution: Received photo of lanyard in place
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 24 June 2022
Resolved
Label out of service equipment including bilge manifold and forward distribution panel.
CITE: 46 CFR 182.100
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 14 August 2022
Resolution: Recieved photo of Out of Service components labeled.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 June 2022
Resolved
Provide approved fire extinguisher bracket at operating station.
CITE: 46 CFR 181.500
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 14 August 2022
Resolution: Owner stated they had removed a fire extinguisher from the vessel that did not have an approved bracket. Emailed owner to state that only 3 total are required, but that they must be kept at the specific locations of Op Sta, ER, and Accom.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 June 2022
Resolved
Vessel limited to NMT than 20 miles from harbor of safe refuge (No life jacket lights)
CITE: 46 CFR 180.71
Action required: 705 - Other - as specified
Resolved 21 August 2023
Resolution: Ammended the COI per the owners request, they will not be going more than 20 miles from a harbor of safe refuge.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 24 June 2022
Resolved
Log drills as required.
CITE: 46 CFR 185.520
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 14 August 2022
Resolution: Recieved photo of vessel's log with adequate details
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 June 2022
Resolved
All flammable liquids to be stowed in a approved container.
CITE 46 CFR 183.530
Action required: 10 - Deficiency Rectified
Resolved 28 June 2022
Resolution: Flammable items were removed from the vessel.
04 - Emergency Systems › N/A - No Subsystem › Means of communication between safety centre and other control stations
Issued 25 May 2021
Resolved
Public address system not functioning.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 June 2021
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 25 May 2021
Resolved
Battery found expired for EPIRB.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2021
Resolved 9 June 2021
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 25 May 2021
Resolved
Sea painter not attached for IBA.
Action required: 10 - Deficiency Rectified
Resolved 25 May 2021
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 25 May 2021
Resolved
Mesh cover for fuel vents to be cleaned.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2021
Resolved 9 June 2021
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 25 May 2021
Resolved
Port rudder post found leaking.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2021
Resolved 9 June 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 May 2021
Resolved
No portable hand bilge pump onboard as required.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2021
Resolved 25 June 2021
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 25 May 2021
Resolved
Wire cables not properly supported using metal supports every 24" as required. Vessel is given to next annual to clear deficiency.
Action required: 705 - Other - as specified
Due 25 May 2022
Resolved 22 August 2023
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 June 2020
Resolved
Fire hose- if garden hose is used, it shall be of good commercial grade constructed of an inner rubber tube, plies of braided cotton reinforcement and an outer rubber cover or of equivalent material and shall be fitted with a commercial garden hose nozzle of good grade bronze or equivalent metal.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 June 2021
Resolved 25 June 2021
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 25 June 2020
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up to date charts, coast pilot, light list, tide tables. Provide up to date publications. See NVIC 1-16 for details on electronic publications.
Action required: 705 - Other - as specified
Due 1 June 2021
Resolved 25 June 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 June 2020
Resolved
At least one ring life buoy must be fitted with a lifeline that is buoyant, 60' in length, non-kinking, dark or synthetic. Line was found frayed and need to be renewed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2021
Resolved 25 June 2021
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 25 June 2020
Resolved
All vessels must have navigation lights in compliance with the applicable sections of Navigation Rules. Vessel found to have mast head light not working. Vessel shall get all nav lights working properly.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 October 2020
Resolution: Received photo of properly functioning masthead light.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 June 2020
Resolved
Inspection of all machinery essential to the routine operation of the vessel including cooling systems. Raw water cooling line to main engine found dry rotted and in need of replacement. Vessel shall replace.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2021
Resolved 25 June 2021
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 11 June 2019
Resolved
Vessel is missing alcohol test strips.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 June 2019
Resolved 30 July 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 11 June 2019
Resolved
Provide a new rubber gasket for the forepeak hatch.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 June 2019
Resolved 30 July 2019
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 11 June 2019
Resolved
The fuel fill line has a small hole. Repair fuel fill as new.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 July 2019
Resolved 25 June 2021