MAURY USCG vessel records Sign in
← All vessels

KIOWA SPIRIT

KIOWA SPIRIT is a 1999 tank ship. The Coast Guard has recorded 39 inspections since 1999, most recently in November 2010, along with 9 deficiencies and 19 operational controls, 1 with no removal date recorded.

Records from 1999 to 2010. Most recent: inspection, 4 November 2010.

Built
1999
Last inspected
4 November 2010
Documentation
Not in the documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

9171826 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
488987
Flag
LIBERIA
—
Maury page id
psix-488987

Inspections, by type

…with no type recorded19
Years with a record 10 calendar years (1999–2010)
The 39 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it33072 - Convention (Subpart B), Net Ton
113269 - Dead Weight, Ton
62619 - Simplified, Gross Ton
62619 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 39

4 November 2010 COE-Dockside
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3876595
8 September 2010 Damage Survey
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3845354
8 June 2008 ISPS II Exam · PII Safety Exam · COC-TVE Renew · Ballast Water Examination · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3230182
7 June 2008 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3231114
16 January 2008 Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 3131652
3 July 2007 MARPOL Annex V Examination · STCW 95 Exam · COC-TVE Annual · ISPS II Exam · Ballast Water Examination · ILO-147 Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2982057
27 June 2007 Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2975518
13 January 2007 Deficiency Check
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2856582
2 June 2006 COC-TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2673231
15 January 2006 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2578779
19 June 2005 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2423813
18 June 2005 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2396478
30 May 2005 COC-TVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2370857
3 December 2004 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2253101
3 December 2004 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2254078
2 December 2004 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2255591
29 May 2004 Certificate of Compliance · MTSA/ISPS Verification
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2081800
13 May 2004 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2066562
1 March 2004 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2015724
23 November 2003 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1952770
21 August 2003 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1882968
27 July 2003 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1859435
27 July 2003 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1862005
9 July 2003 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1841365
9 July 2003 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1845702
24 June 2003 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1825787
22 May 2003 Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1798808
21 May 2003 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1798253
3 April 2003 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1768757
5 January 2003 Ballast Water Examination · Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1725791
4 June 2002 Examination of Repairs
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1626425
22 May 2002 Tank Vessel Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1618969
20 May 2002 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1619684
28 February 2002 In-Service Inspection · Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1490189
8 May 2000 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 277673
11 February 2000 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 476253
1 July 1999 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 430247
6 May 1999 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 428166
6 May 1999 Tank Vessel Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 798100

Deficiency record · 9

Engineering › Steering Gear System › Motor
Issued 8 September 2010 Resolved
Vessel reported #2 steering gear pump motor coupling damaged. Vessel is required to maintain two identical power units for their steering gear.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 September 2010
Resolution: Vessel contacted manufacturer and carried out a manufacturer approved temporary repair. Vessel was attended by class surveyor who attested to the satisfactory temporary repair and imposed a timeline for the full repair.
Fire Fighting › Fixed Deck Foam System › Foam Applicators
Issued 8 June 2008 Resolved
Vessel's fire fighting foam certificate states foam is unacceptable. The concentrate test sample which was tested by UNITOR 13MAY08 is not acceptable. Vessel shall provide documentation certifying that the foam concentrate is satisfactory prior to conducting cargo operations in the United States and departure from port.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 June 2008
Resolution: Received report from UNITOR that 3000LTR was delivered to the Vessel and that the product is in compliance with the required standards.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 8 June 2008 Resolved
02 def. - The 220v switchboards insulation resistance meter is inoperable. In addition there are several grounds on this switchboard which need immediate attention. Vessel shall repair all issues to the satisfaction of the certificate issuing authority. Vessel shall submit certificate issuing authority report attesting to proper operation prior to departure.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 June 2008
Resolution: Received satisfactory class report attesting to repairs.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Manifold
Issued 30 May 2005 Resolved
Gratings over cargo containment area under cargo manifolds are completely wasted through. Prior to 30Jun2005, vessel must replace all gratings to the satisfaction of the certificate issuing authority. Vessel's certificate issuing authority was made aware of the gratings wastage in early January and still have not rectified the problem.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2005
Resolved 19 June 2005
Resolution: Gratings over the cargo containment and cranes: New gratings were found installed on both port and starboard side cargo manifold containments. Gratings on the cranew were found newly painted and free of rust on corrosion.
Stability › Watertight Integrity › General
Issued 30 May 2005 Resolved
Gaskets on numerous watertight doors hardened and painted over. Knife edges on bottom of doors covered in rust. Prior to 31Jun2005, master must provide this office a statement attesting to the replacement of main deck gaskets and rust-freeing of knife edges.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2005
Resolved 19 June 2005
Resolution: Watertight doors on deck: All watertight doors on the main deck were inspected and found in order. The rubber gaskets were found newly replaced and the steel doors with all corroded areas at the edge grit blasteed and painted.
Construction/Loadline › Markings
Issued 5 January 2003 Resolved
PLIMSOLL MARK NEEDS TO BE PERMANENTLY AFFIXED TO THE HULL OF THE VESSEL. AS REQUIRED BY ILLC 66. CORRECT DURING NEXT DRYDOCK, APRIL 2004. LEGACY COMPONENT DESC: Load Line Assigning Authority Mark
Action required: 705 - Other - as specified
Due 30 April 2004
Resolved 13 May 2004
Resolution: VESSEL HAS PLIMSOLL MARK PERMANENTLY AFFIXED TO THE HULL OF THE VESSEL
Navigation › Collision/Grounding Avoidance
Issued 4 June 2002 Resolved
Inoperable primary radar; 33 CFR 164.35(a); Provide repair tech report verifying repair and sat operation. LEGACY COMPONENT DESC: Radar
Action required: 17 - Rectify deficiencies prior to departure
Due 4 June 2002
Resolved 6 June 2002
Resolution: Received satisfactory technician''s report, deficiency cleared.
Navigation › Collision/Grounding Avoidance
Issued 4 June 2002 Resolved
Inoperable secondary radar; 33 CFR 164.37(a); Provide repair tech report verifying repair and sat operation. LEGACY COMPONENT DESC: Radar
Action required: 17 - Rectify deficiencies prior to departure
Due 4 June 2002
Resolved 6 June 2002
Resolution: Received satisfactory technician''''s report, deficiency cleared.
Navigation › Collision/Grounding Avoidance
Issued 28 February 2002 Resolved
Secondary marine radar inoperable, 33 CFR 164.37 (a). LEGACY COMPONENT DESC: Radar
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 28 February 2002
Resolved 5 March 2002
Resolution: Received satisfactory technician servicing report that secondary marine radar was repaired and working within specifications.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.