← All vessels
ENDLESS
Freight Ship · Bulk Carrier class · Built 1990s · USCG Northwest District (CGD-NW) · Other hulls named ENDLESS
ENDLESS is a 1999 freight ship. The Coast Guard has recorded 23 inspections since 1999, most recently in February 2012, along with 18 deficiencies and 2 operational controls.
Records from 1999 to 2012. Most recent: inspection, 19 February 2012.
- Built
- 1999
- Last inspected
- 19 February 2012
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 18 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9169110 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
3FK08
488989
Flag
PANAMA
—
Maury page id
psix-488989
Inspections, by type
…with no type recorded12
Years with a record
9 calendar years (1999–2012)
The 23 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 14 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it24348 - Convention (Subpart B), Net Ton
73437 - Dead Weight, Ton
83993 - Displacement, Ton
38932 - Convention (Subpart B), Gross Ton
73437 - Dead Weight, Ton
83993 - Displacement, Ton
38932 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 23
19 February 2012
PI Safety Exam
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4248558
18 February 2012
Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4252217
17 February 2012
Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4246881
16 February 2012
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4239258
31 January 2011
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3932046
20 January 2010
MARPOL Annex I Examination · ISPS II Exam · Ballast Water Examination · MARPOL Annex VI Survey · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3662553
16 December 2008
MARPOL Annex V Examination · ISPS II Exam · PII Safety Exam · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3377754
30 October 2007
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3090156
23 October 2007
ISPS II Exam · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3085906
27 October 2006
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2809464
9 September 2006
ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2773906
8 September 2006
STCW 95 Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2773020
8 September 2006
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2773520
30 August 2006
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2765566
28 August 2006
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2762680
19 July 2006
ISPS II Exam · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2718102
27 January 2003
Ballast Water Examination · Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1736009
5 September 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 281841
30 August 2000
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 281455
18 August 2000
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 90071
13 March 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 275797
14 December 1999
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 39332
12 August 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 432378
Deficiency record · 18
Engineering › Diesel Engine (auxiliary) › Governor
Issued 31 January 2011
Resolved
1499 - Other (Prop. and Aux. Machinery) - The electrical power available shall be sufficient to supply all those services that are essential for safety in an emergency. During testing of the emergency generator it was discovered that the engine fluctuates approximately 100 rpms with no electrical load. - SOLAS 2004 cons. II-1/43
Electrical › Lighting (service) › Grounding Conductor
Issued 20 January 2010
Resolved
0950- Electric equipment in general- Parts washing machine in main space workshop was wired into the overhead light fixture. Have class attest to the safety of this electrical installation. 74 SOLAS 2004 Cons Ed. II-1/40
Engineering › Lubricating Oil Service System › Purifier
Issued 20 January 2010
Resolved
1499- Other (propulsion & aux. machinery)- Sludge from the auxiliary engine oil purifier has been routed to a temporary containment tank rather than directly to sludge tank. Remove crew alterations and return system to original design, have Class attest to proper functioning of system. 74 SOLAS 2004 Cons Ed. II-1/26
Engineering › Diesel Engine (auxiliary) › Turbocharger
Issued 20 January 2010
Resolved
1430- Auxiliary Engines- Crew had cut the intake side of a turbo charger, attached it to an electric motor and bolted it to the intake side of the generator turbo. There was no guard on the turbine and the fan had been hard wired with an extension cord. Remove fan, have class attest to the proper function of all auxiliary engines under load. 74 SOLAS 2004 Cons Ed II-1/26.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 20 January 2010
Resolved
1410- Propulsion main engine- Aft end of the MDE exhaust manifold was deteriorated and a light patch of soot on the overhead suggested a possible exhaust leak. Make repairs to aft end of exhaust manifold and have Class attest to proper function of exhaust system. 74 SOLAS 2004 Cons Ed II-1/26
Engineering › Lubricating Oil Service System › Purifier
Issued 20 January 2010
Resolved
1420- Cleanliness of engine room- Multiple fuel oil leaks noted throughout the purifier and engine rooms. Numerous catchment systems fashioned by the crew with standing oil and oil soaked lagging in the purifier room all contributed to unsafe environment. Class to attest to replacement of lagging, leaks being addressed and standing oil removed. 74 SOLAS 2004 ed. II-1/26, MSC Circ 647
Engineering › Steering Gear System › Pump
Issued 16 December 2008
Resolved
#1 and #2 steering gear pumps are leaking hydraulic oil from the pump seals during all modes of operation.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Pump, Positive Displacement
Issued 16 December 2008
Resolved
Fuel oil priming pump #3 auxiliary engine is leaking.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Block
Issued 16 December 2008
Resolved
#2 auxiliary engine is leaking water from the #1 cylinder head.
Electrical › Electrical Distribution System (emergency) › Non-conducting Deck Covering
Issued 23 October 2007
Resolved
Non-conductive matting was not provided for the emergency switchboard in the emergency generator room, posing undue risk to the crew and ship. SOLAS 2004 Ch II-1 Reg 45.2 17a
Fire Fighting › Miscellaneous Items › Insulation (Penetration of Oil/Oil Vapors)
Issued 23 October 2007
Resolved
Oil soaked lagging and oily rags were found throughout the FO/LO purifier room posing undue risk to crew and ship. SOLAS 1997 CH II-2 Reg 18.6 17a
Fire Fighting › Fire Hoses › Connections
Issued 23 October 2007
Resolved
Fire hose on port side main deck near superstructure is missing gasket necessary for proper seal rendering hose not ready for use posing undue risk to crew and ship. SOLAS 1997 CH II-2 Reg 4.7 17a
Construction/Loadline › Structures › Door
Issued 23 October 2007
Resolved
Door closure main deck starboard side superstructure is loose preventing door from opening posing undue risk to crew and ship. SOLAS 2004 CH I Reg 11 17a
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 8 September 2006
Resolved
Vessel is unable to demonstrate compliance with the safe minimum safe manning certificate as evidenced by crew unwilling to stand required/necessary duties. Vessel may not depart the Port nor move from its current location until vessel can prove compliance with safe manning certificate. The vessel may request a deadship tow through the Captain of the Port.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 19 July 2006
Resolved
fire door not performing "self closing"
Fire Fighting › Emergency Fire Pumps › Pressure
Issued 19 July 2006
Resolved
not capable of providing 2 jets of water at any substaintial pressure.
Personnel › Training › Diesel Engineering
Issued 19 July 2006
Resolved
crew not accurately recording tank sounding levels
Engineering
Issued 30 August 2000
Resolved
PROVE PROPER OPERATION OF OILY WATER SEPARATOR (OWS) 15 PPM ALARM AND AUTOMATIC STOPPING DEVICE. ALARM/AUTOMATIC STOP ARE NOT WORKING UNTIL INDICATOR READS OVER 30 PPM. OWS IS NOT TO BE USED IN U.S. WATERS UNTIL CORRECTED. MARPOL 73/78 ANNEX I/16
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.