Inspection record

Last inspected 20 July 2026
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDF3829
489095
Flag
UNITED STATES
Maury page id
psix-489095

Documentation record

Registered dimensions (L × B × D)50.0 ft × 14.2 ft × 6.3 ft
Registered tonnagegross 29 / net 23
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderUNIFLITE INC · BELLINGHAM, WA, UNITED STATES · built 1976
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portMAGNOLIA SPRINGS, AL
Endorsements, as the file codes themcw_un
DocumentationValid · issued 3 August 2026 · expires 31 August 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it23 - Simplified, Net Ton
29 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 23 inspections, each with its date, unit and type; 48 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 23

20 July 2026 Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8430610
22 July 2025 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8183313
13 November 2024 Drydock Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8034101
11 July 2024 Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7956074
24 July 2023 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7751180
30 November 2022 Administrative Inspection · Drydock Exam · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7602710
1 August 2022 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7525024
12 April 2022 COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7429314
16 July 2021 In-Service Inspection · Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7258299
18 February 2021 Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7143068
18 November 2020 Administrative Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7097971
15 July 2020 Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7006820
11 July 2019 Deficiency Check · Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6746548
30 October 2018 Drydock Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6571425
9 July 2018 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6472965
20 July 2017 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6215503
18 July 2017 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6214311
5 June 2017 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6167964
3 April 2017 Administrative Inspection · DAPI Audit · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6116565
30 January 2017 Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6079964
25 October 2016 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6029560
7 September 2016 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5994830
26 July 2016 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5953510

Deficiency record · 48

01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 20 July 2026 Resolved
Any vessel of at least five net tons which engages in coastwise trade must have a Certificate of Documentation bearing a valid endorsement appropriate for the activity in which engaged. Marine Inspector found the CoD onboard to be expired.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2026
Resolved 3 August 2026
Resolution: Verified COD is current.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 July 2025 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Grab line on ring life buoy was excessively dry rotted. Replace grab line. 46 CFR 176.808(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2025
Resolved 5 August 2025
Resolution: Received evidence of grab line replaced
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 22 July 2025 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Compartment protected by Fireboy was not vapor tight due to wire installations. Make compartment vapor tight. 46 CFR 176.830(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2025
Resolved 5 August 2025
Resolution: Received evidence of engine compartment made vapor tight with fire foam
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 14 November 2024 Resolved
The owner or managing operator shall make a vessel available for dry-dock examinations. A vessel worklist was generated at drydock exam pertaining to damage to hull and keel. O/O did not respond/was unable to be contacted. Shipyard visit 26NOV2024, MI noticed vessel not present/drydocked. Vessel is restricted from sailing and carrying passengers until drydock is completed to the satisfaction of the Coast Guard.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 March 2025
Resolution: Repair photographs received. drydock credit granted for November 2024.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 26 April 2022 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2022
Resolved 29 April 2022
Resolution: Owner recieved FCC radio station inspection and cert
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 26 April 2022 Resolved
All navigation lights must be operational. Anchor light is not working. Replace or repair anchor light. COLREG rule 20
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2022
Resolved 29 April 2022
Resolution: Owner replaced anchor light
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 26 April 2022 Resolved
Vessel must be equipped with at least two operable portable battery lights. Portable lights were not on board. Put two portable lights on vessel. 46 CFR 183.430
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2022
Resolved 29 April 2022
Resolution: Owner put two portable lights on board
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 26 April 2022 Resolved
Vessel must have appropriate charts for the intended voyage and must be up to date. Charts were out of date.Update charts. 46 CFR 184.420(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2022
Resolved 29 April 2022
Resolution: Owner updated charts
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 26 April 2022 Resolved
Vessels operating solely within 20 nautical miles of land must be equipped with a VHF-DSC radiotelephone. VHF radio screen was not working. Vessel route restricted, vessel may not operate more than 1,000 feet from shore until new radio with MMSI number is inputed and cleared by the Coast Guard. 47 CFR 80.905
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 May 2022
Resolved 29 April 2022
Resolution: Owner replaced radio and recieved his FCC inspection and Radio Station Cert
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 August 2021 Resolved
Life ring needs vessel name labeled on it, line is in need of replacing, and retro tape is on the verge of being non compliant. Advised owner it may be cheaper to procure a new one vs using current one. 46CFR185.604
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 August 2021
Resolved 21 October 2021
Resolution: Received photo evidence of repaired life ring lettering.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 12 August 2021 Resolved
Each vessel must be marked as required by part 67, subpart I, of this chapter. Vessel hailing port must be labeled on the stern of the vessel. 46CFR185.602(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 September 2021
Resolved 21 October 2021
Resolution: Received photo evidence of hailing port on stern.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 20 November 2020 Resolved
Found worn FRP section on stern of vessel. Submit repair proposal to bring back to original strength.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 December 2020
Resolved 7 December 2020
Resolution: Recieved pictures of full repair of new glass over the buffed area. all satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 July 2019 Resolved
05 life jackets had worn retroflective tape. Replace retroflective tape or provide new, approved life jackets. Vessel is restricted to 45 adult passengers and 02 crew.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 August 2019
Resolved 23 July 2019
Resolution: Owner provided photograph of life jackets with renewed retroflective tape
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 22 July 2019 Resolved
Radio at main deck operating station was not fully functional. Radio at operating station in tuna tower was just replaced as previous was non operation. Neither had fully functional DSC capabilities. Provide 02 fully functional radios with DSC capabilities. Renew FCC Radio Safety Certificate to correlate with new radio installations. Vessel is restricted to operation not to exceed 1000 feet from shore.
Condition: Invalid
Action required: 705 - Other - as specified
Due 5 August 2019
Resolved 17 September 2019
Resolution: Owner provided new radio safety certificate for the installation of the 2 VHF radios.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 22 July 2019 Resolved
Main Engine raw water intake through hull valve handle was not secured to valve. Ensure handle is permanently attached to valve for operation.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2019
Resolved 5 September 2019
Resolution: Raw water intake valve handle was replaced
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 July 2019 Resolved
Ring life buoy floating water light was expired. Renew with in date battery approved for use in the water light.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2019
Resolved 17 September 2019
Resolution: Owner renewed floating water light battery
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 22 July 2019 Resolved
Eye wash, aspiring, and disinfecting wipes in first aid kit were expired. Provide new in date replacements.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2019
Resolved 5 September 2019
Resolution: All expired first aid items were replaced
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 22 July 2019 Resolved
02 new cables were run through hold in fwd engine room bulkhead, compromising vapor tight foam. Ensure hole is resealed for vapor tight boundary.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2019
Resolved 5 September 2019
Resolution: Cables had been appropriately sealed to ensure vapor tightness
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 July 2019 Resolved
Main engine shaft seal was dripping excessively when shaft was turning. Tighten or repack shaft seal so water entry is a controlled drip.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 5 August 2019
Resolved 22 July 2019
Resolution: Master tightened shaft packing seal so that water entry was a controlled drip
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 July 2019 Resolved
Life ring buoy labeling was worn and unreadable. Relabel ring life buoy with vessel name.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2019
Resolved 22 July 2019
Resolution: Master re-labelled life ring with vessel name.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 July 2019 Resolved
Retroflective tape on ring life buoy was peeling and worn. Replace retroflective tape on ring life buoy.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2019
Resolved 5 September 2019
Resolution: Retroflective Tape was renewed
Documentation › Certificates/Documents › FCC SSL
Issued 2 May 2017 Resolved
Obtain marine radio operator permit for master and crew members who operate the radio.
Action required: 705 - Other - as specified
Due 2 June 2017
Resolved 5 June 2017
Resolution: Operators permit provided.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 2 May 2017 Resolved
Provide current copy of Nav Rules
Action required: 705 - Other - as specified
Due 2 June 2017
Resolved 5 June 2017
Resolution: New nav rules on board.
Documentation › Logs/Records › Logbook (official)
Issued 2 May 2017 Resolved
Conduct and log radio checks.
Action required: 705 - Other - as specified
Due 2 June 2017
Resolved 5 June 2017
Resolution: Radio log provided.
Documentation › Logs/Records › Logbook (official)
Issued 2 May 2017 Resolved
Properly document drills.
Action required: 705 - Other - as specified
Due 2 June 2017
Resolved 5 June 2017
Resolution: Drills conducted and logged.
Documentation › Logs/Records › Logbook (official)
Issued 2 May 2017 Resolved
Properly document crew training.
Action required: 705 - Other - as specified
Due 2 June 2017
Resolved 5 June 2017
Resolution: Crew training provided.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 2 May 2017 Resolved
Provide alcohol test strips IAW
Action required: 705 - Other - as specified
Due 2 June 2017
Resolved 5 June 2017
Resolution: Owner stated his route provides enough time for the test to be conducted with in the two hours.
Lifesaving › Lifebuoys › Serviceable
Issued 2 May 2017 Resolved
Replace life ring buoy lanyard and retroreflective tape.
Action required: 705 - Other - as specified
Due 2 June 2017
Resolved 5 June 2017
Resolution: Life ring completed.
Communications › Alarms/Indicators › High Water Alarm
Issued 2 May 2017 Resolved
Label forward bilge pump at operating station.
Action required: 705 - Other - as specified
Due 2 June 2017
Resolved 5 June 2017
Resolution: Labeled bilge pump at operating station.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 2 May 2017 Resolved
Clean port and starboard bilge areas on main deck forward.
Action required: 705 - Other - as specified
Due 2 June 2017
Resolved 5 June 2017
Resolution: Area was cleaned.
Deck/Cargo › Mooring/Anchoring › Anchor Rope
Issued 2 May 2017 Resolved
Replace anchor line and fittings.
Action required: 705 - Other - as specified
Due 2 June 2017
Resolved 5 June 2017
Resolution: Fittings were replaced.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 2 May 2017 Resolved
Provide tool to open stern hatch and clean up to ensure proper operation.
Action required: 705 - Other - as specified
Due 2 June 2017
Resolved 5 June 2017
Resolution: Tool provided and on board.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 2 May 2017 Resolved
Provide anchor light that is in compliance with 46 CFR 183.420
Action required: 705 - Other - as specified
Due 2 June 2017
Resolved 5 June 2017
Resolution: Anchor light on board approved.
Engineering › Steering Gear System › Rudder
Issued 2 May 2017 Resolved
Repair water leaks on both rudder shafts.
Action required: 705 - Other - as specified
Due 2 June 2017
Resolved 20 July 2017
Resolution: Work completed and tested satisfactory.
Engineering › Steering Gear System › Rudder
Issued 2 May 2017 Resolved
Tiller handle needs to lock on tiller’s arm.
Action required: 705 - Other - as specified
Due 2 June 2017
Resolved 20 July 2017
Resolution: Pin was mounted on tiller arm for locking purpose.
Communications › Alarms/Indicators › High Water Alarm
Issued 2 May 2017 Resolved
Repair highwater visual bilge alarm.
Action required: 705 - Other - as specified
Due 2 June 2017
Resolved 5 June 2017
Resolution: High water alarmed worked.
Communications › Radio Communications › VHF Radiotelephone
Issued 2 May 2017 Resolved
Link GPS with VHF for proper use of DSC.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 June 2017
Resolved 5 June 2017
Resolution: GPS to VHF and MMSI installed and working.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 1 August 2016 Resolved
Life buoy retro tape worn. Replace with new retro tape.
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 August 2016
Resolved 7 September 2016
Resolution: Retro tape replaced
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 1 August 2016 Resolved
Life buoy clip seized. Replace or repair float light clip.
Condition: Invalid
Action required: 705 - Other - as specified
Due 22 September 2016
Resolved 25 October 2016
Resolution: Replaced Life Buoy float light Clip
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 1 August 2016 Resolved
Life jacket stowage location not properly labeled. Label stowage.
Condition: Invalid
Action required: 705 - Other - as specified
Due 22 September 2016
Resolved 25 October 2016
Resolution: Life jacket stowage has been labeled correctly
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 1 August 2016 Resolved
Exhaust lagging is deteriorated. Replace with new lagging.
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 August 2016
Resolved 7 September 2016
Resolution: Lagging replaced.
Engineering › Fuel Oil Service System › Filter
Issued 1 August 2016 Resolved
Fuel filter is dressed with a valve. Plug fuel filter.
Condition: Invalid
Action required: 705 - Other - as specified
Due 22 September 2016
Resolved 25 October 2016
Resolution: Brass pipe plug has been installed under the valve.
Engineering › Bilge Water Management System › Manifold
Issued 1 August 2016 Resolved
Bilge panel not labeled. Label panel to indicate location of bilge pumps.
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 August 2016
Resolved 7 September 2016
Resolution: Panel labeled.
Construction/Loadline › Structures › Machinery Space Opening
Issued 1 August 2016 Resolved
Forward bulkhead in engine room not vapor tight. Make vapor tight.
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 August 2016
Resolved 7 September 2016
Resolution: Bulkhead made vapor tight.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 1 August 2016 Resolved
Marine radio operator permit or safety certificate not on board. Provide documents.
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 August 2016
Resolved 7 September 2016
Resolution: Marine radio operator permit provided.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 1 August 2016 Resolved
Current copy or inland navigation rules not on board. Provide updated copy.
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 August 2016
Resolved 7 September 2016
Resolution: New copy of Nav Rules provided.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 1 August 2016 Resolved
Anchor lighting location where it is obstructed reducing visibility. Relocate anchor light in an area that provides proper visibility.
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 August 2016
Resolved 7 September 2016
Resolution: New anchor light installed where visible from 360 degrees.
Electrical › Electric Generation Source (service) › Grounding Conductor
Issued 1 August 2016 Resolved
Ground wire for fuel fill missing. Install ground wire.
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 August 2016
Resolved 7 September 2016
Resolution: Ground wire installed.

Ownership record