MAURY USCG vessel records Sign in
← All vessels

SURF'S UP

SURF'S UP is a 1976 passenger vessel (inspected). The Coast Guard has recorded 53 inspections since 1999, most recently in July 2026, along with 131 deficiencies and 2 casualty investigations between 2014 and 2017.

Records from 1999 to 2026. Most recent: inspection, 20 July 2026.

Built
1976
Last inspected
20 July 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDF3829
489095
Flag
UNITED STATES
367444530
Maury page id
psix-489095

Inspections, by type

…with no type recorded3
Years with a record 26 calendar years (1999–2026)
The 53 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)50.0 ft × 14.2 ft × 6.3 ft
Registered tonnagegross 29 / net 23
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderUNIFLITE INC · BELLINGHAM, WA, UNITED STATES · built 1976
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portMAGNOLIA SPRINGS, AL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 3 August 2026 · expires 31 August 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it23 - Simplified, Net Ton
29 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDM9495MMSI 367444530 · active · compulsorily equipped · granted 28 April 2022, expires 28 April 2032 · licensed under a name not among this hull’s recorded names (not shown)
WDF3829MMSI 367444530 · expired · compulsorily equipped · granted 25 March 2010, cancelled 30 May 2020
WCZ7213MMSI not assigned · cancelled · compulsorily equipped · granted 23 March 2000, cancelled 22 March 2010 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 53

20 July 2026 Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8430610
22 July 2025 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8183313
13 November 2024 Drydock Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8034101
11 July 2024 Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7956074
24 July 2023 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7751180
30 November 2022 Administrative Inspection · Drydock Exam · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7602710
1 August 2022 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7525024
12 April 2022 COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7429314
16 July 2021 In-Service Inspection · Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7258299
18 February 2021 Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7143068
18 November 2020 Administrative Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7097971
15 July 2020 Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7006820
11 July 2019 Deficiency Check · Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6746548
30 October 2018 Drydock Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6571425
9 July 2018 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6472965
20 July 2017 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6215503
18 July 2017 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6214311
5 June 2017 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6167964
3 April 2017 Administrative Inspection · DAPI Audit · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6116565
30 January 2017 Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6079964
25 October 2016 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6029560
7 September 2016 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5994830
26 July 2016 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5953510
5 November 2015 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5758264
1 September 2015 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5232584
20 July 2015 Deficiency Check · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5190338
26 June 2014 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4914484
8 May 2012 Deficiency Check · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4277115
23 December 2011 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4213223
24 August 2011 Deficiency Check · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4125856
27 July 2009 Deficiency Check · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3547374
22 April 2009 Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3458535
11 August 2008 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3289719
16 June 2008 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3227279
27 June 2007 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2975491
15 May 2007 COI Inspection · Deficiency Check · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2927988
2 May 2007 Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2913534
19 March 2007 Drydock Extension
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2890795
28 March 2006 Annual Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2610918
23 May 2005 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2363542
24 February 2005 Deficiency Check · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2298362
26 March 2004 Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2032068
13 May 2003 Deficiency Check · Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1791664
14 January 2003 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1726967
1 August 2002 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1670528
6 June 2002 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1626019
8 November 2001 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1076407
12 October 2001 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1425218
24 January 2001 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 825438
1 May 2000 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 818008
28 June 1999 Excursion Permit
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1083300
8 June 1999 Initial Certification · Hull Examination · Plan Review "T" Boat
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1469908
26 May 1999 Inclining Experiment
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1461165

Deficiency record · 131

01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 20 July 2026 Resolved
Any vessel of at least five net tons which engages in coastwise trade must have a Certificate of Documentation bearing a valid endorsement appropriate for the activity in which engaged. Marine Inspector found the CoD onboard to be expired.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2026
Resolved 3 August 2026
Resolution: Verified COD is current.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 July 2025 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Grab line on ring life buoy was excessively dry rotted. Replace grab line. 46 CFR 176.808(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2025
Resolved 5 August 2025
Resolution: Received evidence of grab line replaced
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 22 July 2025 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Compartment protected by Fireboy was not vapor tight due to wire installations. Make compartment vapor tight. 46 CFR 176.830(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2025
Resolved 5 August 2025
Resolution: Received evidence of engine compartment made vapor tight with fire foam
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 14 November 2024 Resolved
The owner or managing operator shall make a vessel available for dry-dock examinations. A vessel worklist was generated at drydock exam pertaining to damage to hull and keel. O/O did not respond/was unable to be contacted. Shipyard visit 26NOV2024, MI noticed vessel not present/drydocked. Vessel is restricted from sailing and carrying passengers until drydock is completed to the satisfaction of the Coast Guard.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 March 2025
Resolution: Repair photographs received. drydock credit granted for November 2024.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 26 April 2022 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2022
Resolved 29 April 2022
Resolution: Owner recieved FCC radio station inspection and cert
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 26 April 2022 Resolved
All navigation lights must be operational. Anchor light is not working. Replace or repair anchor light. COLREG rule 20
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2022
Resolved 29 April 2022
Resolution: Owner replaced anchor light
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 26 April 2022 Resolved
Vessel must be equipped with at least two operable portable battery lights. Portable lights were not on board. Put two portable lights on vessel. 46 CFR 183.430
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2022
Resolved 29 April 2022
Resolution: Owner put two portable lights on board
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 26 April 2022 Resolved
Vessel must have appropriate charts for the intended voyage and must be up to date. Charts were out of date.Update charts. 46 CFR 184.420(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2022
Resolved 29 April 2022
Resolution: Owner updated charts
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 26 April 2022 Resolved
Vessels operating solely within 20 nautical miles of land must be equipped with a VHF-DSC radiotelephone. VHF radio screen was not working. Vessel route restricted, vessel may not operate more than 1,000 feet from shore until new radio with MMSI number is inputed and cleared by the Coast Guard. 47 CFR 80.905
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 May 2022
Resolved 29 April 2022
Resolution: Owner replaced radio and recieved his FCC inspection and Radio Station Cert
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 August 2021 Resolved
Life ring needs vessel name labeled on it, line is in need of replacing, and retro tape is on the verge of being non compliant. Advised owner it may be cheaper to procure a new one vs using current one. 46CFR185.604
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 August 2021
Resolved 21 October 2021
Resolution: Received photo evidence of repaired life ring lettering.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 12 August 2021 Resolved
Each vessel must be marked as required by part 67, subpart I, of this chapter. Vessel hailing port must be labeled on the stern of the vessel. 46CFR185.602(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 September 2021
Resolved 21 October 2021
Resolution: Received photo evidence of hailing port on stern.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 20 November 2020 Resolved
Found worn FRP section on stern of vessel. Submit repair proposal to bring back to original strength.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 December 2020
Resolved 7 December 2020
Resolution: Recieved pictures of full repair of new glass over the buffed area. all satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 July 2019 Resolved
05 life jackets had worn retroflective tape. Replace retroflective tape or provide new, approved life jackets. Vessel is restricted to 45 adult passengers and 02 crew.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 August 2019
Resolved 23 July 2019
Resolution: Owner provided photograph of life jackets with renewed retroflective tape
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 22 July 2019 Resolved
Radio at main deck operating station was not fully functional. Radio at operating station in tuna tower was just replaced as previous was non operation. Neither had fully functional DSC capabilities. Provide 02 fully functional radios with DSC capabilities. Renew FCC Radio Safety Certificate to correlate with new radio installations. Vessel is restricted to operation not to exceed 1000 feet from shore.
Condition: Invalid
Action required: 705 - Other - as specified
Due 5 August 2019
Resolved 17 September 2019
Resolution: Owner provided new radio safety certificate for the installation of the 2 VHF radios.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 22 July 2019 Resolved
Main Engine raw water intake through hull valve handle was not secured to valve. Ensure handle is permanently attached to valve for operation.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2019
Resolved 5 September 2019
Resolution: Raw water intake valve handle was replaced
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 July 2019 Resolved
Ring life buoy floating water light was expired. Renew with in date battery approved for use in the water light.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2019
Resolved 17 September 2019
Resolution: Owner renewed floating water light battery
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 22 July 2019 Resolved
Eye wash, aspiring, and disinfecting wipes in first aid kit were expired. Provide new in date replacements.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2019
Resolved 5 September 2019
Resolution: All expired first aid items were replaced
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 22 July 2019 Resolved
02 new cables were run through hold in fwd engine room bulkhead, compromising vapor tight foam. Ensure hole is resealed for vapor tight boundary.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2019
Resolved 5 September 2019
Resolution: Cables had been appropriately sealed to ensure vapor tightness
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 July 2019 Resolved
Main engine shaft seal was dripping excessively when shaft was turning. Tighten or repack shaft seal so water entry is a controlled drip.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 5 August 2019
Resolved 22 July 2019
Resolution: Master tightened shaft packing seal so that water entry was a controlled drip
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 July 2019 Resolved
Life ring buoy labeling was worn and unreadable. Relabel ring life buoy with vessel name.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2019
Resolved 22 July 2019
Resolution: Master re-labelled life ring with vessel name.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 July 2019 Resolved
Retroflective tape on ring life buoy was peeling and worn. Replace retroflective tape on ring life buoy.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2019
Resolved 5 September 2019
Resolution: Retroflective Tape was renewed
Documentation › Certificates/Documents › FCC SSL
Issued 2 May 2017 Resolved
Obtain marine radio operator permit for master and crew members who operate the radio.
Action required: 705 - Other - as specified
Due 2 June 2017
Resolved 5 June 2017
Resolution: Operators permit provided.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 2 May 2017 Resolved
Provide current copy of Nav Rules
Action required: 705 - Other - as specified
Due 2 June 2017
Resolved 5 June 2017
Resolution: New nav rules on board.
Documentation › Logs/Records › Logbook (official)
Issued 2 May 2017 Resolved
Conduct and log radio checks.
Action required: 705 - Other - as specified
Due 2 June 2017
Resolved 5 June 2017
Resolution: Radio log provided.
Documentation › Logs/Records › Logbook (official)
Issued 2 May 2017 Resolved
Properly document drills.
Action required: 705 - Other - as specified
Due 2 June 2017
Resolved 5 June 2017
Resolution: Drills conducted and logged.
Documentation › Logs/Records › Logbook (official)
Issued 2 May 2017 Resolved
Properly document crew training.
Action required: 705 - Other - as specified
Due 2 June 2017
Resolved 5 June 2017
Resolution: Crew training provided.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 2 May 2017 Resolved
Provide alcohol test strips IAW
Action required: 705 - Other - as specified
Due 2 June 2017
Resolved 5 June 2017
Resolution: Owner stated his route provides enough time for the test to be conducted with in the two hours.
Lifesaving › Lifebuoys › Serviceable
Issued 2 May 2017 Resolved
Replace life ring buoy lanyard and retroreflective tape.
Action required: 705 - Other - as specified
Due 2 June 2017
Resolved 5 June 2017
Resolution: Life ring completed.
Communications › Alarms/Indicators › High Water Alarm
Issued 2 May 2017 Resolved
Label forward bilge pump at operating station.
Action required: 705 - Other - as specified
Due 2 June 2017
Resolved 5 June 2017
Resolution: Labeled bilge pump at operating station.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 2 May 2017 Resolved
Clean port and starboard bilge areas on main deck forward.
Action required: 705 - Other - as specified
Due 2 June 2017
Resolved 5 June 2017
Resolution: Area was cleaned.
Deck/Cargo › Mooring/Anchoring › Anchor Rope
Issued 2 May 2017 Resolved
Replace anchor line and fittings.
Action required: 705 - Other - as specified
Due 2 June 2017
Resolved 5 June 2017
Resolution: Fittings were replaced.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 2 May 2017 Resolved
Provide tool to open stern hatch and clean up to ensure proper operation.
Action required: 705 - Other - as specified
Due 2 June 2017
Resolved 5 June 2017
Resolution: Tool provided and on board.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 2 May 2017 Resolved
Provide anchor light that is in compliance with 46 CFR 183.420
Action required: 705 - Other - as specified
Due 2 June 2017
Resolved 5 June 2017
Resolution: Anchor light on board approved.
Engineering › Steering Gear System › Rudder
Issued 2 May 2017 Resolved
Repair water leaks on both rudder shafts.
Action required: 705 - Other - as specified
Due 2 June 2017
Resolved 20 July 2017
Resolution: Work completed and tested satisfactory.
Engineering › Steering Gear System › Rudder
Issued 2 May 2017 Resolved
Tiller handle needs to lock on tiller’s arm.
Action required: 705 - Other - as specified
Due 2 June 2017
Resolved 20 July 2017
Resolution: Pin was mounted on tiller arm for locking purpose.
Communications › Alarms/Indicators › High Water Alarm
Issued 2 May 2017 Resolved
Repair highwater visual bilge alarm.
Action required: 705 - Other - as specified
Due 2 June 2017
Resolved 5 June 2017
Resolution: High water alarmed worked.
Communications › Radio Communications › VHF Radiotelephone
Issued 2 May 2017 Resolved
Link GPS with VHF for proper use of DSC.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 June 2017
Resolved 5 June 2017
Resolution: GPS to VHF and MMSI installed and working.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 1 August 2016 Resolved
Life buoy retro tape worn. Replace with new retro tape.
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 August 2016
Resolved 7 September 2016
Resolution: Retro tape replaced
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 1 August 2016 Resolved
Life buoy clip seized. Replace or repair float light clip.
Condition: Invalid
Action required: 705 - Other - as specified
Due 22 September 2016
Resolved 25 October 2016
Resolution: Replaced Life Buoy float light Clip
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 1 August 2016 Resolved
Life jacket stowage location not properly labeled. Label stowage.
Condition: Invalid
Action required: 705 - Other - as specified
Due 22 September 2016
Resolved 25 October 2016
Resolution: Life jacket stowage has been labeled correctly
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 1 August 2016 Resolved
Exhaust lagging is deteriorated. Replace with new lagging.
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 August 2016
Resolved 7 September 2016
Resolution: Lagging replaced.
Engineering › Fuel Oil Service System › Filter
Issued 1 August 2016 Resolved
Fuel filter is dressed with a valve. Plug fuel filter.
Condition: Invalid
Action required: 705 - Other - as specified
Due 22 September 2016
Resolved 25 October 2016
Resolution: Brass pipe plug has been installed under the valve.
Engineering › Bilge Water Management System › Manifold
Issued 1 August 2016 Resolved
Bilge panel not labeled. Label panel to indicate location of bilge pumps.
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 August 2016
Resolved 7 September 2016
Resolution: Panel labeled.
Construction/Loadline › Structures › Machinery Space Opening
Issued 1 August 2016 Resolved
Forward bulkhead in engine room not vapor tight. Make vapor tight.
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 August 2016
Resolved 7 September 2016
Resolution: Bulkhead made vapor tight.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 1 August 2016 Resolved
Marine radio operator permit or safety certificate not on board. Provide documents.
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 August 2016
Resolved 7 September 2016
Resolution: Marine radio operator permit provided.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 1 August 2016 Resolved
Current copy or inland navigation rules not on board. Provide updated copy.
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 August 2016
Resolved 7 September 2016
Resolution: New copy of Nav Rules provided.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 1 August 2016 Resolved
Anchor lighting location where it is obstructed reducing visibility. Relocate anchor light in an area that provides proper visibility.
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 August 2016
Resolved 7 September 2016
Resolution: New anchor light installed where visible from 360 degrees.
Electrical › Electric Generation Source (service) › Grounding Conductor
Issued 1 August 2016 Resolved
Ground wire for fuel fill missing. Install ground wire.
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 August 2016
Resolved 7 September 2016
Resolution: Ground wire installed.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 4 August 2015 Resolved
Life jacket stowage needs to be labeled, IAW 46CFR180.78
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 August 2015
Resolved 19 August 2015
Resolution: Deficiency corrected to the satisfaction of the marine inspector.
Operations/Management › Navigation Safety › Proper Use of Navigation/Anchor Lights
Issued 4 August 2015 Resolved
Anchor light switch is not working properly. Repair IAW 46CFR183.540
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 August 2015
Resolved 19 August 2015
Resolution: Deficiency corrected to the satisfaction of the marine inspector.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 4 August 2015 Resolved
Log required steering , machinery and FCC radio daily checks before getting u/w. IAW 46CFR185.320
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 August 2015
Resolved 19 August 2015
Resolution: Deficiency corrected to the satisfaction of the marine inspector.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 4 August 2015 Resolved
COD expired July 31st 2015, need to renew. IAW 46CFR67.7 Owner called NVDC and had them inform me that paper work was in and that NVDC was working on it.
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 August 2015
Resolved 19 August 2015
Resolution: Deficiency corrected to marine inspectors satisfaction.
Engineering › Steering Gear System › Rudder Stock
Issued 20 July 2015 Resolved
Rudder was leaking at a steady flow at mooring and more while u/w. Repair as needed IAW 46CFR179.360
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 August 2015
Resolved 4 August 2015
Resolution: Tighten rudder shaft packing and leak was stopped.
Engineering › Bilge Water Management System › Piping
Issued 20 July 2015 Resolved
Pipe system was found for old bilge pumps that was not needed or in service, needs to cap or remove. IAW 46CFR176.610
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 September 2015
Resolved 5 November 2015
Resolution: Piping is filled with sealant and capped on both sides.
Documentation › Certificates/Documents › FCC SSL
Issued 20 July 2015 Resolved
Station license was not on board during inspection. IAW 47CFR80.13 Owner stated he has it at home.
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 August 2015
Resolved 1 September 2015
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Fire Fighting › Remote Fuel Shutoff › General
Issued 20 July 2015 Resolved
F/O shut off valve not labeled, IAW 46CFR185.608
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 August 2015
Resolved 19 August 2015
Resolution: Deficiency corrected to marine inspectors satisfaction.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Approval
Issued 8 May 2012 Resolved
Prove fire extinguishers have been serviced within the last 12 month as per 46 CFR 176.810
Action required: 705 - Other - as specified
Due 8 June 2012
Resolved 18 June 2012
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 8 May 2012 Resolved
Provide original C.O.D. upon request from attending CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Due 8 June 2012
Resolved 18 June 2012
Communications › Radio Communications › Cellular Telephone Capability
Issued 8 May 2012 Resolved
Complete vessel specific information on on Marine Distress Communication placard as per 46 CFR 184.506.
Action required: 705 - Other - as specified
Due 8 June 2012
Resolved 18 June 2012
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 8 May 2012 Resolved
Provide and maintain lifesaving equipment maintenance log book as per 46 CFR 185.702.
Action required: 705 - Other - as specified
Due 8 June 2012
Resolved 18 June 2012
Documentation › Markings/Placards › Lifejacket Placard
Issued 8 May 2012 Resolved
Provide lifejacket donning placard for type of lifejackets onboard vessel as per 46 CFR 185.516.
Action required: 705 - Other - as specified
Due 8 June 2012
Resolved 18 June 2012
Engineering › Fuel Oil Service System › Valve, Control
Issued 8 May 2012 Resolved
Prove proper operation of fuel shut off valve serving both port and stbd fuel tanks as per 46 CFR 182.455.
Action required: 705 - Other - as specified
Due 8 June 2012
Resolved 18 June 2012
Operations/Management › Drills/Instruction › Abandon Ship
Issued 8 May 2012 Resolved
Update posted emergency instructions to include abandon ship as per 46 CFR 185.510 and .512.
Action required: 705 - Other - as specified
Due 8 June 2012
Resolved 18 June 2012
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 8 May 2012 Resolved
Repair cracked rescue platform where wood is splitting at base of platform at chain connection point.
Action required: 705 - Other - as specified
Due 8 June 2012
Resolved 18 June 2012
Resolution: Repair completed
Fire Fighting › Portable CO2 Fire Extinguisher › Condition
Issued 24 August 2011 Resolved
02 B-II found heavily corroded, replace in kind.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2012
Resolution: Replaced in kind.
Engineering › Fuel Oil Service System › Valve
Issued 24 August 2011 Resolved
Shut-off valve for STBD fuel tank missing, provide individual and operational system for each Tank.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2012
Resolution: Installed positive shut-off valve at tank.
Lifesaving › Lifejacket/PFD (Type II) › Retroreflective Material
Issued 24 August 2011 Resolved
Retroreflective Material found deteriorated on child life-jackets, replace in kind.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2012
Resolution: Replaced in kind.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 24 August 2011 Resolved
COD not onboard, renew, obtain and provide
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2012
Resolution: Proof of new COI faxed to COTP.
Fire Fighting › Fire Bucket › Capacity
Issued 24 August 2011 Resolved
Fire bucket found fractured and poorly stenciled, renew and replace in kind.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2012
Resolution: Replaced in kind.
Engineering › Diesel Engine (propulsion-reduction gear) › Turbocharger
Issued 24 August 2011 Resolved
Engine exhaust pipe found fractured in way of turbocharger, renew replace in kind and prove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2012
Resolution: Replaced in kind.
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 24 August 2011 Resolved
FCC Safety Radiotelephony Certificate not available, renew obtain or provide accordingly.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 September 2011
Resolved 8 May 2012
Resolution: Renewed certificate.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 24 August 2011 Resolved
Anchor light found not operational, make repair IAW NAVRULES.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 September 2011
Resolved 8 May 2012
Resolution: Replaced in kind.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 24 August 2011 Resolved
Ring bouy found improperly marked, restencil accordingly.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2011
Resolved 8 May 2012
Resolution: bouy found marked to the satisfaction of attending CG Marine Inspector.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 24 August 2011 Resolved
Waterlight braket found defective, repair.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2011
Resolved 8 May 2012
Resolution: Replaced in kind.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 24 August 2011 Resolved
User fees past due, renew with FINCEN
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2012
Resolution: Fees paid.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 17 August 2009 Resolved
Prove proper operation of the pre-engineered fixed extinguishing system in the engine room prior to carrying passenger.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 August 2009
Resolved 17 August 2009
Resolution: The audible alarm panel was replaced and tested with satisfactory results.
Documentation › Certificates/Documents › FCC SSL
Issued 16 June 2008 Resolved
Provide current radio telephony safety certificate issued by the FCC.
Action required: 705 - Other - as specified
Due 16 July 2008
Resolved 15 July 2008
Resolution: Certificate faxed to office.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 16 June 2008 Resolved
Provide original copy of Certificate of Documentation.
Action required: 705 - Other - as specified
Due 16 July 2008
Resolved 11 August 2008
Resolution: Original copy onboard vessel.
Engineering › Fuel Oil Service System › Filter
Issued 16 June 2008 Resolved
Install flame bowl on the Racor fuel filter.
Action required: 705 - Other - as specified
Due 16 July 2008
Resolved 11 August 2008
Resolution: Flame bowl added.
Engineering › Steering Gear System › Fastener
Issued 16 June 2008 Resolved
Install double-nuts or Nylock nuts on all connecting bolts in the steering system.
Action required: 705 - Other - as specified
Due 16 July 2008
Resolved 11 August 2008
Resolution: Nylock nuts added.
Documentation › Certificates/Documents › FCC SSL
Issued 15 May 2007 Resolved
Provide a FCC marine radio operator permit to the satisfaction of the attending Coast Guard Marine Inspector as required by 47 CFR
Due 15 June 2007
Resolved 6 June 2007
Resolution: Provided proof that the master had completed the required training to obtain the FCC marine radio operator permit. Master had not received the permit yet.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 15 May 2007 Resolved
Provide proof that 50% of the crew has Red Cross 1st Aid/CPR training to the satisfaction of the attending Coast Guard Marine Inspector as required by NVIC 1-91
Due 15 June 2007
Resolved 6 June 2007
Resolution: Provided proof that both the master and deckhand had Red Cross 1st Aid/CPR training
Navigation › Piloting/Steering › Coast Guard Light List
Issued 15 May 2007 Resolved
Provide current CG Light List and Tidal Current Tables to the satisfaction of the attending Coast Guard Marine Inspector as required by 46 CFR 184.420
Due 15 June 2007
Resolved 6 June 2007
Resolution: Provided current CG Light List and Tidal Current Tables
Navigation › Piloting/Steering › Gyro Compass
Issued 15 May 2007 Resolved
Provide light for compass to the satisfaction of the attending Coast Guard Marine Inspector as required by 46 CFR 184.402
Due 15 June 2007
Resolved 15 May 2007
Resolution: Provide a written request to change route to day light operations only.
Lifesaving › Hand Flares › Storage
Issued 15 May 2007 Resolved
Provide a watertight container for stowage of signaling devices to the satisfaction of the attending Coast Guard Marine Inspector as required by 46 CFR 180.68
Due 15 June 2007
Resolved 6 June 2007
Resolution: Provided a watertight container for stowage of signaling devices
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 15 May 2007 Resolved
Properly mark 33 adult and 9 children lifejackets with retro-reflective tape to the satisfaction of the attending Coast Guard Marine Inspector as required by 46 CFR 185.604
Due 15 June 2007
Resolved 17 May 2007
Resolution: Properly marked 33 adult and 9 children lifejackets with retro-reflective tape.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 15 May 2007 Resolved
Properly mark 2 adult and 2 children lifejackets with the vessel name to the satisfaction of the attending Coast Guard Marine Inspector as required by 46 CFR 185.604
Due 15 June 2007
Resolved 17 May 2007
Resolution: Properly marked 2 adult and 2 children lifejackets with the vessel name.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 15 May 2007 Resolved
Properly clean all lifejackets and stowage areas to the satisfaction of the attending Coast Guard Marine Inspector as required by 46 CFR 176.800
Due 15 June 2007
Resolved 6 June 2007
Resolution: Properly cleaned all lifejackets and stowage areas
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 15 May 2007 Resolved
Provide an approved battery for the waterlight on the ring lifebuoy to the satisfaction of the attending Coast Guard Marine Inspector as required by 46 CFR 180.70
Due 15 June 2007
Resolved 6 June 2007
Resolution: Provided an approved battery for the waterlight on the ring lifebuoy
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 15 May 2007 Resolved
Replace the grab line, lifeline, and float line to the waterlight for the ring lifebuoy to the satisfaction of the attending Coast Guard Marine Inspector as required by 46 CFR 180.70
Due 15 June 2007
Resolved 6 June 2007
Resolution: Replaced the grab line, lifeline, and float line to the waterlight for the ring lifebuoy
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 15 May 2007 Resolved
Properly mark the ring lifebuoy with retro reflective tape to the satisfaction of the attending Coast Guard Marine Inspector as required by 46 CFR 185.604
Due 15 June 2007
Resolved 6 June 2007
Resolution: Properly marked the ring lifebuoy with retro reflective tape
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 15 May 2007 Resolved
Provide one BII portable fire extinguisher to the satisfaction of the attending Coast Guard Marine Inspector as required by 46 CFR 181.500
Due 15 June 2007
Resolved 15 May 2007
Resolution: Provided one BII portable fire extinguisher
Engineering › Bilge Water Management System › Valve
Issued 15 May 2007 Resolved
Provide a positive shutoff valve at the hull penetration for both the port and starboard overboard discharge piping for the independent bilge pumps to the satisfaction of the attending Coast Guard Marine Inspector as required by 46 CFR 182.520
Due 15 June 2007
Resolved 6 June 2007
Resolution: Provided a positive shutoff valve at the hull penetration for both the port and starboard overboard discharge piping for the independent bilge pumps
Documentation › Markings/Placards › Garbage Placard
Issued 15 May 2007 Resolved
Properly post the oil pollution and MARPOL V placards to the satisfaction of the attending Coast Guard Marine Inspector as required by 33 CFR 155.450 and 151.59
Due 15 June 2007
Resolved 6 June 2007
Resolution: Properly posted the oil pollution and MARPOL V placards
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 15 May 2007 Resolved
Provide portable lighting at each operating station and one at the entrance to machinery space to the satisfaction of the attending Coast Guard Marine Inspector as required by 46 CFR 183.430
Due 15 June 2007
Resolved 6 June 2007
Resolution: Provided a portable lighting at each operating station and one at the entrance to machinery space
Operations/Management › Pollution › Ballast Water Management
Issued 15 May 2007 Resolved
Clean bilges and make ready for inspection to the satisfaction of the attending Coast Guard Marine Inspector as required by 46 CFR 176.830
Due 15 June 2007
Resolved 6 June 2007
Resolution: Cleaned bilges and made ready for inspection
Operations/Management › Pollution › Control of Discharge of Sewage
Issued 15 May 2007 Resolved
Properly cap off old sewage in take valve to the satisfaction of the attending Coast Guard Marine Inspector as required by 46 CFR 176.800
Due 15 June 2007
Resolved 6 June 2007
Resolution: Properly capped off old sewage in take valve
Engineering › Steering Gear System › Pin
Issued 15 May 2007 Resolved
Prove proper operation of the auxiliary steering in a reasonable amount of time to the satisfaction of the attending Coast Guard Marine Inspector as required by 46 CFR 182.620
Due 15 June 2007
Resolved 6 June 2007
Resolution: Proved proper operation of the auxiliary steering in a reasonable amount of time
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 15 May 2007 Resolved
Prove the ability to recover an unconscious person for the water to the satisfaction of the attending Coast Guard Marine Inspector as required by 46 CFR 180.210
Due 15 June 2007
Resolved 27 June 2007
Resolution: Proved the ability to recover an unconcious person from the water to the staisfaction of the attending Coast Guard Marine Inspector as required by 46 CFR 180.210.
Documentation › Markings/Placards › Capacity Marking
Issued 15 May 2007 Resolved
Properly mark the upper deck with "crew only" signs to the satisfaction of the attending Coast Guard Marine Inspector as required by 46 CFR 185.602
Due 15 June 2007
Resolved 6 June 2007
Resolution: Properly marked the upper deck with "crew only" signs
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 15 May 2007 Resolved
Revise the emergency instructions to reflect actual operations to the satisfaction of the attending Coast Guard Marine Inspector as required by 46 CFR 185.510
Action required: 705 - Other - as specified
Due 15 June 2007
Resolved 27 June 2007
Resolution: Revised the emergency instructions to reflect the actual operations to the satisfaction of the attending Coast Guard Marine Inspector as required by 46 CFR 185.510.
Construction/Loadline › Hull › Side Shell
Issued 2 May 2007 Resolved
Properly grind out two blisters on the starboard side and three blisters on the port side of the hull as per NVIC 8-87.
Action required: 705 - Other - as specified
Due 2 June 2007
Resolved 3 May 2007
Resolution: Properly grinded out two blisters on the starboard side and three blisters on the port side of the hull as per NVIC 8-87.
Construction/Loadline › Penetrations › Gasket
Issued 2 May 2007 Resolved
Prove watertight integrity of the engine room hatch in way of the gasket as per 46 CFR 179.360.
Action required: 705 - Other - as specified
Due 2 June 2007
Resolved 15 May 2007
Resolution: Replaced the gasket on the engine room hatch
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 2 May 2007 Resolved
Replace the aft cutlass bearing on the shaft as per 46 CFR 176.802.
Action required: 705 - Other - as specified
Due 2 June 2007
Resolved 3 May 2007
Resolution: Replaced the aft cutlass bearing on the shaft as per 46 CFR 176.802.
Personnel › Training › First Aid/CPR
Issued 28 March 2006 Resolved
Provide current CPR/First aid cards as required by NVIC 1-91
Action required: 705 - Other - as specified
Due 28 April 2006
Resolved 18 July 2006
Resolution: Provided current CPR/First aid cards as required by NVIC 1-91
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 28 March 2006 Resolved
Provide proof of new COD by 31 MAR 06.
Action required: 705 - Other - as specified
Due 31 March 2006
Resolved 5 April 2006
Resolution: Provided proof of current COD
Documentation › Logs/Records › Logbook (official)
Issued 28 March 2006 Resolved
Provide professional log books for: training, life saving maintenance, and bridge log.
Action required: 705 - Other - as specified
Due 28 April 2006
Resolved 21 July 2006
Resolution: Provided professional log books for: training, life saving maintenance, and bridge log.
Personnel › Training › Visual Communications
Issued 28 March 2006 Resolved
Properly post the emergency instructions list as required by 46 CFR 185.510
Action required: 705 - Other - as specified
Due 28 April 2006
Resolved 18 July 2006
Resolution: Properly posted the emergency instructions list as required by 46 CFR 185.510
Documentation › Markings/Placards › Lifejacket Placard
Issued 28 March 2006 Resolved
Properly post the lifejacket donning placard as required by 46 CFR 185.516
Action required: 705 - Other - as specified
Due 28 April 2006
Resolved 18 July 2006
Resolution: Properly posted the lifejacket donning placard as required by 46 CFR 185.516
Navigation › Piloting/Steering › US Coast Pilot
Issued 28 March 2006 Resolved
Provide a current US Coast Pilot as required by 46CFR184.420
Action required: 705 - Other - as specified
Due 28 April 2006
Resolved 18 July 2006
Resolution: Provided a current US Coast Pilot as required by 46CFR184.420
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 28 March 2006 Resolved
Stow all first aid material together and in an approved container as required by 46 CFR184.710
Action required: 705 - Other - as specified
Due 28 April 2006
Resolved 21 July 2006
Resolution: Stowed all first aid material together and in an approved container as required by 46 CFR184.710
Lifesaving › Work Vest › General
Issued 28 March 2006 Resolved
Provide a harness for the deckhand to use in case of a man overboard.
Action required: 705 - Other - as specified
Due 28 April 2006
Resolved 18 July 2006
Resolution: Provided a harness for the deckhand to use in case of a man overboard.
Lifesaving › Embarkation Appliances/Stations › Steps
Issued 28 March 2006 Resolved
Provide a means to bring someone aboard from the water.
Action required: 705 - Other - as specified
Due 28 April 2006
Resolved 21 July 2006
Resolution: Provided a means to bring someone aboard from the water.
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 28 March 2006 Resolved
Reduce the shaft packing leakage to a slow drip as required by 46CFR176.800
Action required: 705 - Other - as specified
Due 28 April 2006
Resolved 18 July 2006
Resolution: Reduced the shaft packing leakage to a slow drip as required by 46CFR176.800
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 28 March 2006 Resolved
Provide a B-II fire extinguisher outside the machinery space as required by 46 CFR181.500
Action required: 705 - Other - as specified
Due 28 April 2006
Resolved 28 March 2006
Resolution: Provided and installed a B-II portable fire extinguisher.
Navigation › Piloting/Steering › Magnetic Compass
Issued 28 March 2006 Resolved
Provide a light for the magnetic compass as required by 46 CFR184.402, prior to night time operations.
Action required: 705 - Other - as specified
Due 28 April 2006
Resolved 18 July 2006
Resolution: Changed route to reflect daylight operations only
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 28 March 2006 Resolved
Provide new retro tape and name on 10 adult lifejackets and new retro tape on 2 children lifejackets as required by 46 CFR 180.71
Action required: 705 - Other - as specified
Due 28 April 2006
Resolved 21 July 2006
Resolution: Provided new retro tape and name on 10 adult lifejackets and new retro tape on 2 children lifejackets as required by 46 CFR 180.71
Documentation › Certificates/Documents › FCC SSL
Issued 4 May 2004 Resolved
Provide FCC Safety Certificate.
Action required: 705 - Other - as specified
Due 4 June 2004
Resolved 24 February 2005
Resolution: FCC Safety Certificate was provided.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 4 May 2004 Resolved
Provide Coast Guard Light List IAW 46 CFR 184.420.
Action required: 705 - Other - as specified
Due 4 June 2004
Resolved 24 February 2005
Resolution: CG light list was provided.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 4 May 2004 Resolved
Repair inoperable anchor light IAW 46 CFR 183.420.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 June 2004
Resolved 4 May 2004
Resolution: Anchor light repaired IAW 46 CFR 183.420.
Engineering › Steering Gear System
Issued 14 January 2003 Resolved
Repair cracked rudder where marked as per 46 CFR 176.610 LEGACY COMPONENT DESC: Rudder
Due 16 January 2003
Resolved 16 January 2003
Resolution: Welding repairs made and found satisfactory.
Engineering › Shafting/Propeller Arrangements
Issued 14 January 2003 Resolved
Replace forward and aft cutlass bearings as per 46 CFR 176.630. LEGACY COMPONENT DESC: Bearing
Due 16 January 2003
Resolved 16 January 2003
Resolution: Bearing replaced.
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 14 January 2003 Resolved
Have fixed firefighting system serviced as per 46 CFR 176.810(b)(2). LEGACY COMPONENT DESC: Tanks
Due 28 January 2003
Resolved 23 January 2003
Resolution: System serviced, report on file.
Engineering › Fuel Oil Storage/Transfer System
Issued 14 January 2003 Resolved
Repair broken fuel tank strap on port fuel tank as per 46 CFR 182. 440. LEGACY COMPONENT DESC: Tank
Due 23 February 2003
Resolved 13 May 2003
Resolution: Repaired buy using one new strap and tie down rope. Tank was held in place by othe strapping and was secure.
Accommodation/Occupational Safety › Occupational Safety
Issued 14 January 2003 Resolved
Tighten loose rail courses as per 46 CFR 177.900. LEGACY COMPONENT DESC: Deck Rail
Due 23 February 2003
Resolved 13 May 2003
Resolution: Rail courses were tightened.
Engineering › Bilge Water Management System
Issued 14 January 2003 Resolved
Remove trash from forward bilge, make ready for inspection as per 46 CFR 176.830. LEGACY COMPONENT DESC: Bilge
Due 23 February 2003
Resolved 13 May 2003
Resolution: All trash and debree removed from bilge.
Engineering › Bilge Water Management System
Issued 14 January 2003 Resolved
Repair port bilge switch located in head space as per 46 CFR 176.804. LEGACY COMPONENT DESC: Pump
Due 23 February 2003
Resolved 13 May 2003
Resolution: Bilge switch repaired.
Documentation › Certificates/Documents
Issued 6 June 2002 Resolved
Provide FCC safety Radio telephone certificate. LEGACY COMPONENT DESC: FCC Safety Telephone Certificate
Due 6 July 2002
Resolved 1 August 2002
Resolution: Certificate provided.
Lifesaving › Lifebuoys
Issued 6 June 2002 Resolved
Provide retro for ring buoy. LEGACY COMPONENT DESC: Markings (ship name/port)
Due 6 June 2002
Resolved 6 June 2002
Documentation
Issued 12 October 2001 Resolved
PROVIDE VALID FCC RADIO OPERATOR PERMIT IN ACCORDANCE WITH FCC REGULATIONS AS PER 46 CFR 184.502 NO LATER THAN NOVEMBER 12, 2001 TO THE SATISFACTION OF THE ATTENDING U.S. COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 12 October 2001
Resolved 12 October 2001
Documentation
Issued 1 May 2000 Resolved
PROVIDE PROPER FCC SAFETY CERTIFICATE AS REQUIRED BY 47 CFR 80.903.
Condition: Unknown
Due 30 May 2000
Resolved 25 May 2000

Casualty record · 2

26 June 2014Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4914484
18 July 2017Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6214311
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.