Records from 1984 to 1994. Most recent: inspection, 19 December 1994.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 76
19 December 1994
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1153747
20 July 1994
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 216966
28 June 1994
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 504128
9 June 1994
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1021620
27 December 1993
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 94
27 December 1993
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 100075
1 December 1993
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1425374
4 October 1993
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1157708
31 July 1993
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 155975
7 June 1993
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1138386
30 April 1993
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 828051
27 April 1993
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 186174
27 March 1993
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 178724
10 March 1993
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 838106
26 January 1993
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 829569
20 January 1993
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 643107
30 December 1992
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 224456
21 December 1992
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 827443
15 December 1992
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 155296
15 December 1992
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 826362
15 December 1992
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1139335
17 November 1992
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 829062
7 November 1992
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 827768
27 October 1992
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 60899
9 September 1992
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 3878
1 June 1992
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 952621
8 May 1992
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1265736
29 April 1992
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 350356
29 April 1992
Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 957541
17 April 1992
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1261579
8 March 1992
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1256705
9 February 1992
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 945737
26 November 1991
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1316132
21 November 1991
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 347521
20 October 1991
Examination of Repairs
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1248582
16 October 1991
Type not recorded
No type recorded · USCG Southeast District (dp) · USCG Southeast District (CGD-SE) · Activity 643108
6 September 1991
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 643106
26 July 1991
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 939128
10 July 1991
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1250042
1 June 1991
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1018627
25 May 1991
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 525044
31 January 1991
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 932474
10 January 1991
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1221033
23 October 1990
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1229189
23 October 1990
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1242721
22 October 1990
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 507536
7 October 1990
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1218208
19 May 1990
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 462727
15 December 1989
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1232665
15 November 1989
Hull Examination · COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 907044
22 June 1989
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1194801
7 June 1989
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1197757
1 November 1988
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1201311
4 October 1988
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 891695
17 May 1988
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 886676
12 May 1988
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 537360
11 April 1988
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1035110
4 March 1988
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1335773
8 December 1987
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1307995
24 November 1987
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1025476
28 October 1987
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1020190
21 September 1987
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1315755
25 June 1987
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 444894
9 June 1987
Administrative
Administrative · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1001595
8 April 1987
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1334133
5 April 1987
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1021227
9 December 1986
Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1023933
1 November 1986
Permit to Proceed
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1320753
9 September 1986
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 437662
22 August 1986
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1011055
18 October 1985
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1301782
5 October 1985
COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 993839
9 August 1985
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 445899
22 April 1985
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 475985
7 February 1985
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1285263
3 October 1984
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1282721
Fire Fighting
Issued 1 December 1993
Resolved
INSTALL SIGHTGLASS ON FOAM TANK. 46CFR 95.17
Condition: Unknown
Due 1 December 1993
Resolved 1 December 1993
Engineering
Issued 1 December 1993
Resolved
COMPLETE SATISFACTORY INTERNAL EXAM OF DC HEATER IAW 46 CFR 46.10._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 1 December 1994
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 1 December 1993
Resolved
PROVIDE TEST REPORT ON ANALYSIS OF FOAM. 46CFR 95.17
Condition: Unknown
Due 1 January 1994
Resolved 9 December 1993
Engineering
Issued 1 December 1993
Resolved
COMPLETE SATISFACTORY FIRESIDE & WATERSIDE EXAM ON PORT & STBD MAIN BOILERSAT NEXT VESSEL DRYDOCKING IAW 46 CFR 61.05.
Condition: Unknown
Due 1 December 1993
Resolved 1 December 1993
Navigation
Issued 7 November 1992
Resolved
PROVE PROPER OPERATION OF THE STEERING POWER FAILURE ALARMS IN ACCORDANCE WITH 46CFR113.43
Condition: Unknown
Due 31 January 1993
Resolved 22 March 1993
Fire Fighting
Issued 7 November 1992
Resolved
REPAIR/REPLACE LEAKING BALL VALUE AT THE FIRE HYDRANT PORT SIDE, FOC'SLE.
Condition: Unknown
Due 30 November 1992
Resolved 30 November 1992
Lifesaving
Issued 7 November 1992
Resolved
MAKE PROPER FRP REPAIRS TO THE PORT LIFEBOAT IN WAY OF THE KEEL.
Condition: Unknown
Due 30 November 1992
Resolved 30 November 1992
Navigation
Issued 7 November 1992
Resolved
REPLACE THE STBD RUNNING LIGHT LOWER ELEMENT.
Condition: Unknown
Due 30 November 1992
Resolved 30 November 1992
Deck/Cargo
Issued 7 November 1992
Resolved
MAKE PROPER REPAIRS TO THE #5 STBD CARGO TANK 18" EXPANSION TRUNK WHERE WASTED.
Condition: Unknown
Due 7 December 1992
Resolved 10 February 1993
Electrical
Issued 7 November 1992
Resolved
PROVE PROPER OPERATION OF THE SSDG HIGH JACKET WATER SHUTDOWN
Condition: Unknown
Due 27 April 1993
Resolved 27 April 1993
Accommodation/Occupational Safety
Issued 7 November 1992
Resolved
PROVIDE A RELIEF VALVE FOR THE DOMESTIC HOT WATER HEATER._x001C_ IN ACCORDANCE WITH SECTION IV ASME SET AT 210 DEGRESS F, 100 PSI(ONE PRESSURE AND ONE TEMPERATURE OR ONE COMBINATION PRESSURE/TEMPERATURE)
Condition: Unknown
Due 31 August 1993
Resolved 31 August 1993
Accommodation/Occupational Safety
Issued 7 November 1992
Resolved
PROVIDE A HANDRAIL WHERE MISSING IN THE ENGINE ROOM PORT SIDE ONE LEVEL DOWN.
Condition: Unknown
Due 30 November 1992
Resolved 30 November 1992
Engineering
Issued 7 November 1992
Resolved
CALIBRATE THE BOILER GAUGES IN ACCORDANCE WITH 46CFR 61.05-15(F)
Condition: Unknown
Due 7 December 1992
Resolved 23 December 1992
Lifesaving
Issued 8 May 1992
Resolved
END FOR END THE LIFEBOAT FALLS IAW SOLAS 74 CHAPTER III REG 19.4. LAST DONE10/89 STB AND 11/89 PORT.
Condition: Unknown
Due 15 June 1992
Resolved 11 June 1992
Deck/Cargo
Issued 17 April 1992
Resolved
PRIOR TO CARRYING CARGOES VESSEL MUST COMPLETE CARGO TANK AND INTERNAL STRUCTURAL EXAMINATIONS AS REQUIRED BY 46CFR 31.10-21 TO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 7 May 1992
Resolved 7 May 1992
Deck/Cargo
Issued 17 April 1992
Resolved
VESSEL IS ALLOWED TO PROCEED TO ST. CROIX VIRGIN ISLANDS OR ANY U.S. PORT TO COMPLETE EXAMINATIONS REQUIRED BY 46CFR 31.10-21.
Condition: Unknown
Due 7 May 1992
Resolved 7 May 1992
Lifesaving
Issued 26 November 1991
Resolved
PROVIDE ACCESS LADDER AND EMERGENCY LIGHTING FOR EGRESS AND EMBARKATION ANDRAIL ACCESS FOR THE FANTAIL TWO LIFERAFTS IAW 46CFR112.43 AND 46CFR33.20-3 (46CFR33.05-3(c)).
Condition: Unknown
Due 26 November 1991
Resolved 26 November 1991
Fire Fighting
Issued 26 November 1991
Resolved
PROVE PROPER OPERATION OF ALL FIRE DAMPERS (ESPECIALLY GALLEY AND 0-4 DECKS) IAW 46CFR32.56-60(b).
Condition: Unknown
Due 26 November 1991
Resolved 26 November 1991
Navigation
Issued 26 November 1991
Resolved
REWIRE THE RUDDER ARRESTING SYSTEM (RAS) SO AS TO PROVIDE AN EMERGENCY SOURCE OF POWER (WIRE OFF EMERGENCY SWITCHBOARD) IAW 46CFR111.93-7.
Condition: Unknown
Due 26 November 1991
Resolved 26 November 1991
Fire Fighting
Issued 26 November 1991
Resolved
HYDROSTATICALLY TEST 10 PERCENT OF CO2 FIXED AND SEMI-PORTABLE BOTTLE JUMPER HOSES IAW 46CFR31.10-18(e).
Condition: Unknown
Due 26 November 1991
Resolved 26 November 1991
Lifesaving
Issued 26 November 1991
Resolved
PROVIDE SOLAS "A" PACK FOR FORECASTLE LIFERAFT IAW 1983 AMENDMENTS TO SOLAS1974.
Condition: Unknown
Due 20 February 1992
Resolved 29 April 1992
Lifesaving
Issued 26 November 1991
Resolved
HYDROSTATICALLY TEST OR PROVIDE DOCUMENTATION OF SATISFACTORY TEST FOR ALL COMPOSITE BREATHING AIR BOTTLES FOR SCOTT AIR PACKS (3 YEAR HYDRO) IAW 49CFR147.04-1.
Condition: Unknown
Due 7 January 1992
Resolved 20 February 1992
Construction/Loadline
Issued 26 November 1991
Resolved
REPLACE PUMPROOM DOOR,WHICH IS WARPED,IAW VESSEL DRAWINGS.
Condition: Unknown
Due 26 November 1991
Resolved 26 November 1991
Lifesaving
Issued 26 November 1991
Resolved
PROVIDE TWO (2) PROXIMITY SUITS IAW 46CFR35.30-20 IN EMERGENCY GEAR LOCKER.
Condition: Unknown
Due 26 November 1991
Resolved 26 November 1991
Fire Fighting
Issued 10 July 1991
Resolved
RECHARGE AND PROVE PROPER OPERATION OF THE E-GENERATOR SPACE FIXED CO2 SYSTEM. LIVE FIRE WATCH TO BE USED WHENEVER E-GENERATOR OPERATED. FOUR ADDITIONAL CO2 15LB EXTINGUSHERS TO BE MOUNTED WITHIN SPACE.
Condition: Unknown
Due 10 July 1991
Resolved 10 July 1991
Documentation
Issued 10 January 1991
Resolved
PROVIDE MARPOL V PLACARD AND DISPOSAL OF WAST PLAN, IN ACCORDANCE WITH MARPOL V.
Condition: Unknown
Due 10 January 1991
Resolved 10 January 1991
Engineering
Issued 10 January 1991
Resolved
CALABRATE MAIN AND SUPERHEATER PRESS GUAGES FOR PORT AND STARBOARD BOILER IAW 46 CFR 61.05-15 (f).
Condition: Unknown
Due 10 January 1991
Resolved 10 January 1991
Deck/Cargo
Issued 10 January 1991
Resolved
REPAIR/REPLACE ACTUATOR FOR CROSS-CONNECT VALVE LOCATED BETWEEN NOS 1&2 PUMPS.
Condition: Unknown
Due 10 January 1991
Resolved 10 January 1991
Deck/Cargo
Issued 10 January 1991
Resolved
PROVIDE PROPER OPERATION OF THE ENGINE ROOM REMOTE VENTILATION TRIPS IAW 46CFR58.01-25
Condition: Unknown
Due 10 January 1991
Resolved 10 January 1991
Electrical
Issued 10 January 1991
Resolved
PROVE PROPER OPERATION OF SWITCHBOARD (MAIN) E-VENT SHUTDOWN IAW 46CFR58.01-25.
Condition: Unknown
Due 10 January 1991
Resolved 10 January 1991
Fire Fighting
Issued 10 January 1991
Resolved
REPLACE/PROVIDE GUARDS FOR THE EXPLOSION PROF LIGHTING FIXTURE IN THE CARGOROOM AND PAINT LOCKER AND FOCSLE (STBD) ENTERANCE.
Condition: Unknown
Due 10 January 1991
Resolved 10 January 1991
Engineering
Issued 10 January 1991
Resolved
PROVE PROPER OPERATION OF THE STBD BOILERS LOSS OF FAN TRIP IAW 46CFR62.35020(i).
Condition: Unknown
Due 10 January 1991
Resolved 10 January 1991
Electrical
Issued 15 November 1989
Resolved
MAKE PROPER REPAIRS TO LIGHTING PANEL L101 IN THE FOCSLE.
Condition: Unknown
Due 15 November 1989
Resolved 15 November 1989
Accommodation/Occupational Safety
Issued 15 November 1989
Resolved
MAKE PROPER REPAIRS TO MOUNTING BRACKETS AND SHROUD FOR THE EXHAUST FAN MOTOR FOR THE PILOT HOUSE.
Condition: Unknown
Due 15 November 1989
Resolved 15 November 1989
Accommodation/Occupational Safety
Issued 28 October 1987
Resolved
REPAIR ELEVATOR AND TEST SAFTIES AND INTERLOCKS. UNTIL SUCH TIME THE ELE-VATOR IS TO BE STOWED IN THE LOWER POSITION AND DE-ENERGIZED. THE CHIEF ENGINEER IS TO MAINTAIN CUSTODY OF THE KEY.
Condition: Unknown
Due 28 October 1987
Resolved 28 October 1987
Engineering
Issued 28 October 1987
Resolved
REPLACE FLAME SCREENS ON ALL FUEL OIL TANKS
Condition: Unknown
Due 28 October 1987
Resolved 28 October 1987
Construction/Loadline
Issued 28 October 1987
Resolved
MAKE PERMANENT REPAIRS TO BILGE/BALLAST PUMP NO.1 DISCHARGE LINE IN WAY OF SOFT PATCH.
Condition: Unknown
Due 28 October 1987
Resolved 28 October 1987
Engineering
Issued 28 October 1987
Resolved
REPAIR CROSSOVER CONNECTION TO FRESH WATER COOLER
Condition: Unknown
Due 28 October 1987
Resolved 28 October 1987
Navigation
Issued 28 October 1987
Resolved
REPAIR DRAIN PIPE ON FORECASTLE AIR RECEIVER
Condition: Unknown
Due 28 October 1987
Resolved 28 October 1987
Electrical
Issued 28 October 1987
Resolved
REPLACE FUEL OIL FILTERS ON BOTH DIESEL GENERATOR AND EMERGEMCY GENERATOR WITH APPROVED TYPE OR SHOW COMPLIANCE WITH 46CFR SUCHAPTER F FOR THOSE INSTALLED.
Condition: Unknown
Due 28 October 1987
Resolved 28 October 1987
Electrical
Issued 28 October 1987
Resolved
PROVIDE AN EXPLOSION PROOF CABLE FITTING FOR THE EXPLASION PROOF LIGHT FIXTURE AT THE BOTTOM OF THE LADDER TO THE PUMPROOM PRIOR TO LOADING CARGO
Condition: Unknown
Due 28 October 1987
Resolved 28 October 1987
Deck/Cargo
Issued 28 October 1987
Resolved
MAKE PERMANENT REPAIRS TO TO THE WASTED LINE LEADING TO THE NUMBER 6C CRUDEOIL WASH MACHINE PRIOR TO LOADING CRUDE OIL
Condition: Unknown
Due 28 October 1987
Resolved 28 October 1987
Lifesaving
Issued 28 October 1987
Resolved
PROVIDE ONE ADDITIONAL USCG APPROVED WATERLIGHT FOR THE RING BUOYS (15 TOTAL REQUIRED) AT ARRIVAL AT NEXT US PORT.
Condition: Unknown
Due 28 October 1987
Resolved 28 October 1987
Engineering
Issued 28 October 1987
Resolved
CONDUCT FIRE SIDE AND WATER SIDE EXAMINATION OF PORT BOILER AT THE NEXT US PORT
Condition: Unknown
Due 28 October 1987
Resolved 28 October 1987
Construction/Loadline
Issued 5 April 1987
Resolved
COMPLETE PERMANENT REPAIRS TO COLLISION DAMAGE, STARBOARD SIDE FOREPEAK, INCLUDING SHELLPLATE CRACKS AT FRAMES 9 & 10,TRIPPED FRAMES FROM 7 TO 23, BUCKLED "FLAT" PORTION OF COLLISION BULKHEAD. THIS REQUIREMENT MUST BE COMPLETED PRIOR TO LOADING CARGO & PRIOR TO DEPARTURE FROM NEXT PORT OF CALL.
Condition: Unknown
Due 5 April 1987
Resolved 5 April 1987
Construction/Loadline
Issued 9 December 1986
Resolved
MAKE NO.6 PORT WING CARGO TANK SUITABLE FOR A FOLLOW-UP INTERNAL EXAM IN WAY OF FRAME (STRUT BRACES)REPAIRS COMPLETED DURING DRYDOCKING OF DEC 86. PURPOSE: A. IT IS BELIEVED TO BE A CLASS PROBLEM. B.TO DETERMINE IF REPAIR ALTERATIONS COMPLETED ARE HOLDING UP.
Condition: Unknown
Due 9 December 1986
Resolved 9 December 1986
Construction/Loadline
Issued 5 October 1985
Resolved
REPAIR ALL DOUBLE BOTTOM VENT CLOSURES.
Condition: Unknown
Due 5 October 1985
Resolved 5 October 1985
Construction/Loadline
Issued 5 October 1985
Resolved
COMPLETE WELDING REPAIR ON ACCESS CUT INTO I.G.S. ROOM PORT SIDE.
Condition: Unknown
Due 5 October 1985
Resolved 5 October 1985
Lifesaving
Issued 5 October 1985
Resolved
PROVIDE ONE (1) ADDITIONAL SURVIVAL SUIT TO COMPLETE A TOTAL OF 37. TOTAL PERSONS ALLOWED IS LIMITED TO THIRTY (30) UNTIL COMLIED WITH.
Condition: Unknown
Due 5 October 1985
Resolved 5 October 1985
Construction/Loadline
Issued 5 October 1985
Resolved
CONDUCT SATISFACTORY OPERATIONAL TEST OF OVERSPEED TRIP FOR TURBINE BALLASTAND BILGE PUMP.
Condition: Unknown
Due 5 October 1985
Resolved 5 October 1985
Deck/Cargo
Issued 5 October 1985
Resolved
REPAIR/RENEW ALL WASTED AND HOLED ON DECK STEAM HEATING MANIFOLD LINES.
Condition: Unknown
Due 5 October 1985
Resolved 5 October 1985