MAURY USCG vessel records
← All vessels

HOOKED UP

HOOKED UP is a 1999 passenger vessel (inspected). The Coast Guard has recorded 28 inspections since 2016, most recently in March 2026, along with 38 deficiencies and 1 casualty investigation in 2007.

Records from 2007 to 2026. Most recent: inspection, 5 March 2026.

Built
1999
Last inspected
5 March 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 5 March 2026
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDP5522
489244
Flag
UNITED STATES
Maury page id
psix-489244

Documentation record

Registered dimensions (L × B × D)55.0 ft × 17.7 ft × 7.0 ft
Registered tonnagegross 45 / net 36
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGILLMAN MARINE, INC · PANAMA CITY, FL, UNITED STATES · built 1999
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portPANAMA CITY, FL
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 29 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it45 - Simplified, Gross Ton
36 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 28

5 March 2026 Vessel Attendance · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8320494
22 January 2026 Internal Structural Exam · Administrative Inspection · Drydock Exam · Vessel Attendance
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8296862
10 February 2025 Administrative Inspection · DAPI Audit · COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8077536
30 October 2024 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8027140
16 April 2024 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7896212
11 January 2024 Drydock Exam · Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7844248
11 December 2023 In-Service Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7837512
20 October 2023 Administrative Inspection · Special
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7811711
25 May 2023 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7696115
21 September 2022 In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7563633
5 April 2022 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7425148
13 January 2022 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7380407
18 October 2021 Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7334858
4 August 2021 In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7278060
29 March 2021 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7164868
14 January 2021 Type not recorded
No type recorded · USCGC BENJAMIN B. DAILEY (WPC 1123) · USCG Heartland District (CGD-H) · Activity 7142352
17 March 2020 DAPI Audit · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6919519
5 February 2020 Drydock Exam · Administrative Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6903975
20 November 2019 Type not recorded
No type recorded · USCGC BENJAMIN B. DAILEY (WPC 1123) · USCG Heartland District (CGD-H) · Activity 6859764
9 October 2019 Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6839079
18 March 2019 Administrative Inspection · DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6645107
14 November 2018 Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6580528
9 April 2018 DAPI Audit · Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6384099
8 January 2018 Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6333347
25 October 2017 Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6294018
13 March 2017 DAPI Audit · Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6100508
13 April 2016 DAPI Audit · Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5846945
13 March 2016 Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5976200

Deficiency record · 38

07 - Fire Safety › N/A - No Subsystem › Fire patrol
Issued 30 January 2024 Resolved
A night watchman system must be installed and functioning prior to carrying more than six (6) overnight passengers. The vessel is restricted to carrying not more than six (6) overnight passengers until a system is installed and tested for proper operation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 October 2024
Resolution: The watchman device is installed and operational.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 25 May 2023 Resolved
Vessel required to have interconnected fire detection system that meet specific requirements in 46CFR181.450. Vessel did not have onboard or installed interconnected fire detection system. Vessel limited to Limited Coastwise until fire detection system installed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 11 December 2023
Resolution: Interconnected fire detection provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 May 2023 Resolved
Vessel required to have visual and audible indication at operating station to indicate H/W. Vessels H/W light was inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 December 2023
Resolution: H/w light satisfactory.
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 25 May 2023 Resolved
Vessel requied to have marine radio with DSC capability installed. Vessel did not have radio with DSC function installed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 December 2023
Resolution: DSC function programmed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 March 2020 Resolved
Replace melted 110v wire on forward engine room bulkhead. Vessel is restricted from carrying passengers for hire until above deficiency is cleared by an attending CG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 April 2020
09 - Working and Living Conditions › 092 - Working Conditions › Holds and tanks safety
Issued 9 October 2019 Resolved
Repair Fuel oil stops and test emergency fuel shut offs.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 October 2019
Resolution: Fuel shutoffs repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Holds and tanks safety
Issued 9 October 2019 Resolved
Replace fuel fittings at cross connect and fuel supply to generator. Replace fuel hose in addition.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 October 2019
Resolution: Wasted valves and hose replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 9 October 2019 Resolved
Float free link for life float missing. Install for 30 man total. 02 Life floats 15 man ea.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 October 2019
Resolution: New weak link installed.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 9 October 2019 Resolved
Replace and add smoke alarm for passenger space & lounge.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 February 2020
Resolution: Smoke alarms replaced and properly installed.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 9 October 2019 Resolved
Install Egress light in passenger cabin and test.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 February 2020
Resolution: Emergency lighting properly installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 March 2019 Resolved
Bilge pumps inoperative in forward passage and steering space. Repair as needed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2019
Resolved 3 April 2019
Resolution: Corrected inoperative bilge pumps, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 18 March 2019 Resolved
Life float light inoperative. Replace life float light.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2019
Resolved 3 April 2019
Resolution: Replaced Life float light and battery, all sat,
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 18 March 2019 Resolved
Navigation side lights out. Replace port and starboard side lights.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2019
Resolved 3 April 2019
Resolution: Navigation side lights repaired and tested, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 March 2019 Resolved
Raw water cooler hoses worn, replace hoses on both engines between cooler and pump.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2019
Resolved 3 April 2019
Resolution: Replaced water cooler hose and clamps, all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 March 2019 Resolved
Replace broken breaker panel box in engine room.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2019
Resolved 3 April 2019
Resolution: Replaced and installed new junction box, all sat.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 9 April 2018 Resolved
Provide orginal COI.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 April 2018
Resolved 11 April 2018
Resolution: new COI provided to vessel
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 9 April 2018 Resolved
Provide servicing report for fix fire fighting system
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 April 2018
Resolved 11 April 2018
Resolution: provided to CG
Documentation › Certificates/Documents › FCC SSL
Issued 9 April 2018 Resolved
Provide FCC Ship Station Lic
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 April 2018
Resolved 11 April 2018
Resolution: provided to CG
Personnel › Certificates/Documents/Licenses › License, Operator
Issued 9 April 2018 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 April 2018
Resolved 11 April 2018
Resolution: provided to CG
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 9 April 2018 Resolved
Provide FCC Safety Radiotelephony certificate.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 April 2018
Resolved 11 April 2018
Resolution: Provided to CG.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 9 April 2018 Resolved
Conduct DAPI Audit.
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 April 2018
Resolved 11 April 2018
Resolution: Conducted DAPI audit; all SAT
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 8 January 2018 Resolved
Replace cutless bearings on port and STBD shafts.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 January 2018
Resolved 26 January 2018
Resolution: witnessed.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 8 January 2018 Resolved
Clean bilges of water and debri.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 January 2018
Resolved 26 January 2018
Electrical › Lighting (service) › Lighting Fixture
Issued 8 January 2018 Resolved
Renew light fixtures in steering compartment.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 January 2018
Resolved 26 January 2018
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 8 January 2018 Resolved
Refasten bracket for the wire control of the fuel shut off valves.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 January 2018
Resolved 26 January 2018
Resolution: witnessed.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 13 March 2017 Resolved
Provide alcohol test equipment
Action required: 705 - Other - as specified
Due 27 March 2017
Resolved 23 March 2017
Resolution: Vessel provided test equipment
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 13 March 2017 Resolved
Repair emergency lighting
Action required: 705 - Other - as specified
Due 27 March 2017
Resolved 23 March 2017
Resolution: Vessel provided new emergency light
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 13 March 2017 Resolved
Repair navigation lights
Action required: 705 - Other - as specified
Due 27 March 2017
Resolved 23 March 2017
Resolution: Vessel repaired nav light
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 13 March 2017 Resolved
Replace battery
Action required: 705 - Other - as specified
Due 27 March 2017
Resolved 23 March 2017
Resolution: Vessel replaced battery
Lifesaving › Lifefloat › Serviceable
Issued 13 March 2017 Resolved
Properly paint lifefloat.
Action required: 705 - Other - as specified
Due 27 March 2017
Resolved 23 March 2017
Resolution: Vessel painted lifefloat
Lifesaving › Lifefloat › Markings
Issued 13 April 2016 Resolved
Name stenciled on raft and oars,and cleaned.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2016
Resolved 18 April 2016
Resolution: Stenciled and cleaned.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 13 April 2016 Resolved
Provide FCC Safety Radio Telephony Certificate for vessel
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2016
Resolved 18 April 2016
Resolution: Certificate issued
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 13 April 2016 Resolved
Provide Alcohol test equipment to meet the 2hour test requirment.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2016
Resolved 18 April 2016
Resolution: provided
Electrical › Electric Supply System (service) › Battery Installation
Issued 13 April 2016 Resolved
Remove the wing nuts from batteries on vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2016
Resolved 18 April 2016
Resolution: Removed.
Lifesaving › Lifefloat › Serviceable
Issued 13 March 2016 Resolved
Life float needs name stenciled on raft, oars and clean
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 August 2016
Resolved 18 August 2016
Resolution: life float fixed
Communications › Radio Communications › VHF Radiotelephone
Issued 13 March 2016 Resolved
PROVIDE FCC SAFETY RADIOTELEPHONE CERTIFICATE FOR VESSEL
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 August 2016
Resolved 18 August 2016
Resolution: FCC WAS PROVIDED
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 13 March 2016 Resolved
PROVIDE ALCOHOL TEST EQUIPMENT FOR VESSEL
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 August 2016
Resolved 18 August 2016
Resolution: ALCOHOL TEST EQUIPMENT FOR VESSEL PROVIDED
Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 13 March 2016 Resolved
WING NUTSON BATTERIES REMOVED.
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 August 2016
Resolved 18 August 2016
Resolution: WING NUTS REMOVED

Casualty record · 1

17 September 2007Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 3060022
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

LADY J II (2007). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record